{"product_id":"tecpen-map-oxygen-0-5-and-co2-0-100-analyzer","title":"Tecpen MAP Oxygen (0-5%) and CO2 (0-100%) Analyzer","description":"\u003cp\u003eThe \u003cspan style=\"color: rgb(17, 94, 103);\"\u003e\u003cstrong\u003eTecpen MAP Oxygen and Carbon Dioxide Analyzer\u003c\/strong\u003e\u003c\/span\u003e ensures accurate oxygen and carbon dioxide gas level measurements in pierceable, shrink-wrapped packaging.\u003c\/p\u003e\n\u003cp\u003eBy using the \u003cstrong\u003eTS-202\u003c\/strong\u003e individuals are able to gain precise O2 and CO2 measurements in just \u003cem\u003e\u003cstrong\u003eseconds\u003c\/strong\u003e\u003c\/em\u003e while safely monitoring perishables, ensuring food protection, and mitigating the risk of potential food-borne illnesses. \u003c\/p\u003e\n\u003cp\u003e\u003cmeta charset=\"utf-8\"\u003eNot sure which analyzer is right for you? \u003ca title=\"Portable Gas Analyzer Decision Guide - co2meter\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/Decision_Guide_-_co2meter_portable_gas_analyzers.pdf?v=1775587603\"\u003eView our guide to help you decide.\u003c\/a\u003e\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e0-5% O2\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eLong-life NDIR CO2 sensor 0-100%\u003c\/li\u003e\n\u003cli\u003eMeasurements in 3 seconds for oxygen, 10 seconds for CO2\u003c\/li\u003e\n\u003cli\u003eData can be logged and downloaded via USB\u003c\/li\u003e\n\u003cli\u003eIndustry-standard .CSV data files\u003c\/li\u003e\n\u003cli\u003eRechargeable battery up to 300 measurements per charge\u003c\/li\u003e\n\u003cli\u003eCertificate of calibration from the factory\u003c\/li\u003e\n\u003cli\u003eNot cross-sensitivity to carbon monoxide, hydrocarbons\u003c\/li\u003e\n\u003cli\u003eNo cross-sensitivity to H2S, ionic strength, flow\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eModified atmospheric packaging (MAP) for Quality Control\u003c\/li\u003e\n\u003cli\u003ePharmaceuticals and biotechnology\u003c\/li\u003e\n\u003cli\u003eHygiene detection (pathogenic), microorganism growth\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eBiochemical and molecular biology research\u003c\/li\u003e\n\u003cli\u003eCell culture vessels, Infusion containers\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eMicro-bioreactors\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eModels\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.co2meter.com\/products\/modified-atmosphere-packaging-oxygen-analyzer\" title=\"TecPen MAP Oxygen Analyzer\"\u003e\u003cstrong\u003eTS-200: \u003c\/strong\u003eTecpen MAP Oxygen Analyzer\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.co2meter.com\/collections\/tecsense\/products\/map-o2-co2-analyzer\" title=\"Tecpen MAP Oxygen and Carbon Dioxide Analyzer\"\u003e\u003cstrong\u003eTS-202: \u003c\/strong\u003eTecpen MAP Oxygen and Carbon Dioxide Analyzer\u003c\/a\u003e\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"specifications\"\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eOxygen Sensor\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eMeasurement Range: 0-5% O2\u003c\/li\u003e\n\u003cli\u003eAccuracy @ 0-0.5%: ± 2%Mev**\u003c\/li\u003e\n\u003cli\u003eAccuracy @ 0.5-2.5%: ±3% Mv*\u003c\/li\u003e\n\u003cli\u003eAccuracy @ 2.5-5%: ±5% Mv*\u003c\/li\u003e\n\u003cli\u003eResolution: 1ppm\u003c\/li\u003e\n\u003cli\u003eResponse time at 25°C\/ 77°F: \u0026lt;150ms\u003c\/li\u003e\n\u003cli\u003ePump flow: 400mL\/min.\u003c\/li\u003e\n\u003cli\u003eTemp. range Min.\/Max: -10°C\/ +60°C (14°F\/140°F)\u003c\/li\u003e\n\u003cli\u003eTemperature compensation: 10-30°C (50-86 °F)\u003c\/li\u003e\n\u003cli\u003eZero-point adjustment interval: adjusted to air at power on\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCO2 Sensor\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eMeasurement Range: 0-100%\u003c\/li\u003e\n\u003cli\u003eAccuracy @ 1%: ±70 ppm +\/- 5% of measuring value\u003c\/li\u003e\n\u003cli\u003eAccuracy @ 100%: ±300 ppm +\/-5% of measuring value\u003c\/li\u003e\n\u003cli\u003eResolution 1ppm\u003c\/li\u003e\n\u003cli\u003ePump flow: 400mL\/min.\u003c\/li\u003e\n\u003cli\u003eResponse time at 25°C\/ 77°F: 10s\u003c\/li\u003e\n\u003cli\u003eTemp. range Min.\/Max: -25°C\/55°C (-13°F\/ 131°F)\u003c\/li\u003e\n\u003cli\u003eTemperature compensation: 10-30°C (50-86 °F)\u003c\/li\u003e\n\u003cli\u003eRecommended zero-point adjustment interval by customer: 6 months\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eDevice\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ePump flow max.: 67 mL\u003c\/li\u003e\n\u003cli\u003eMedium: Gas\u003c\/li\u003e\n\u003cli\u003ePower supply: 5V USB and LiPo battery\u003c\/li\u003e\n\u003cli\u003eRechargeable battery lifetime: \u0026gt; 3 hours per charge\u003c\/li\u003e\n\u003cli\u003eData Interface: USB\u003c\/li\u003e\n\u003cli\u003eDisplay: OLED\u003c\/li\u003e\n\u003cli\u003eCleaning housing: no organic solvents. 40% EtOH\u003c\/li\u003e\n\u003cli\u003eParts touching sample: St.1.4404\/ PTFE\/ Glas\u003c\/li\u003e\n\u003cli\u003eCase: Anodized aluminum\u003c\/li\u003e\n\u003cli\u003eProtection Class: IP65\u003c\/li\u003e\n\u003cli\u003eFull-service interval by Manufacturer (includes necessary retrofitting): 3 years\u003c\/li\u003e\n\u003cli\u003eLife time of O2 sensor (protective atmosphere; 0- 40°C): 2 years\u003c\/li\u003e\n\u003cli\u003eSensor cap replacement interval: 2 years\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eCase with Device Weight: 2.45 lbs.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eCase Dimensions: 12 x 11 x 3.25 inches\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eDevice Weight: 0.50 lbs.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eDevice Dimensions: 7 x 2 x 1 inch\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e**Mev = measured end value\u003cbr\u003e*Mv = measured values\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan style=\"color: rgb(0, 0, 0);\"\u003ePlease note: TecSense sensors are CE, FCC, IC, KC, and MIC marked, meet the requirements of ASTM F2714-08, and the European and Canadian standards for food safety. The company is DIN ISO 9001\/2015 certified.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eWarranty\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 year - \u003cstrong\u003e\u003ca title=\"CO2Meter Terms and Conditions\" href=\"https:\/\/www.co2meter.com\/pages\/terms-conditions\"\u003ePlease see CO2Meter Terms and Conditions\u003c\/a\u003e\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"documents\"\u003e\n\u003ch2\u003eDocuments\u003c\/h2\u003e\n\u003cp\u003e\u003ca title=\"Gaslab Fixed Gas Detector Datasheet\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/DS-MSC2-Fixed_Multi_Gas_Detector_-CO2Meter.pdf?v=1724771962\" target=\"_blank\"\u003e\u003cimg alt=\"Fixed Industrial Gas Detector DataSheet\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1093\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/Data_Sheet_TS-202_Tecpen_MAP_Oxygen_and_Carbon_Dioxide_Analyzer_co2meter.pdf?v=1778855674\" title=\"Data Sheet_TS-202_Tecpen MAP Oxygen and Carbon Dioxide Analyzer_co2meter\"\u003e\u003cspan style=\"text-decoration: underline;\"\u003e \u003c\/span\u003e\u003cstrong\u003e\u003cspan color=\"#ff0000\" style=\"color: #ff0000;\"\u003eData Sheet (pdf)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/DS-MSC2-Fixed_Multi_Gas_Detector_-CO2Meter.pdf?v=1724771962\" title=\"Gaslab Fixed Gas Detector Datasheet\" target=\"_blank\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1093\" alt=\"Fixed Industrial Gas Detector DataSheet\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/Manual-TecPen-TS-202-Oxygen-CO2-Analyzer-CO2Meter.pdf?v=1709043553\"\u003e \u003cstrong\u003e\u003cspan color=\"#ff0000\" style=\"color: #ff0000;\"\u003eManual (pdf)\u003c\/span\u003e\u003c\/strong\u003e \u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca title=\"Gaslab Fixed Gas Detector Datasheet\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/DS-MSC2-Fixed_Multi_Gas_Detector_-CO2Meter.pdf?v=1724771962\" target=\"_blank\"\u003e\u003cimg alt=\"Fixed Industrial Gas Detector DataSheet\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1093\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/TecPen-Declaration-of-Conformity-CO2Meter-30.pdf?v=1679586360https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/TecPen-Declaration-of-Conformity-CO2Meter-30.pdf?v=1679586360\" title=\"TecSense Declaration of Conformity\"\u003e \u003cstrong\u003e\u003cspan color=\"#ff0000\" style=\"color: #ff0000;\"\u003eDeclaration of Conformity (pdf)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1093\"\u003e \u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/www.youtube.com\/watch?v=37X1RGg5Szk\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0406\/7681\/t\/8\/assets\/youtube.gif?\" alt=\"calibration\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\"\u003e Factory Reset and Calibration Video\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"accessories\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003ch3\u003eAccessories\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePRT-SEPTUMS \u003c\/strong\u003e- septum's (pack of 18) - \u003ca title=\"Contact CO2Meter to learn more\" href=\"https:\/\/www.co2meter.com\/pages\/contact\"\u003e\u003cspan style=\"text-decoration: underline;\"\u003econtact us \u003c\/span\u003e\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePRT-NEEDLES  \u003c\/strong\u003e- 25\/0.8 needles (pack of 10) - \u003ca title=\"contact us for more info\" href=\"https:\/\/www.co2meter.com\/pages\/contact\"\u003e\u003cspan style=\"text-decoration: underline;\"\u003econtact us\u003c\/span\u003e\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCM-0118 \u003c\/strong\u003e- hydrophobic filter qty. 10 - \u003ca title=\"contact us for more info\" href=\"https:\/\/www.co2meter.com\/pages\/contact\"\u003e\u003cspan style=\"text-decoration: underline;\"\u003econtact us\u003c\/span\u003e\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTS R1 HH 007 \u003c\/strong\u003e- flexible extension - \u003ca title=\"contact us for more info\" href=\"https:\/\/www.co2meter.com\/pages\/contact\"\u003e\u003cspan style=\"text-decoration: underline;\"\u003econtact us\u003c\/span\u003e\u003c\/a\u003e\u003cspan style=\"text-decoration: underline;\"\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"TecSense","offers":[{"title":"TS-202 Tecpen MAP Oxygen + CO2 Analyzer","offer_id":49030515261696,"sku":"TS-202","price":9735.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0388\/5331\/2557\/files\/tecpen-map-oxygen-and-carbon-dioxide-analyzer-317150.jpg?v=1784471194","url":"https:\/\/alotechparts.com\/pt\/products\/tecpen-map-oxygen-0-5-and-co2-0-100-analyzer","provider":"Alo Tech Solutions","version":"1.0","type":"link"}