{"product_id":"juniper-ex9204-red3b-dc-chassis","title":"Juniper EX9204-RED3B-DC Chassis","description":"\u003cdiv class=\"short-hide\"\u003e[shortdesc]\n\u003cul\u003e\n\u003cli\u003eBase EX9204 system configuration\u003c\/li\u003e\n\u003cli\u003e4-slot chassis with passive midplane\u003c\/li\u003e\n\u003cli\u003e2 x EX9200-RE2 routing engine\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e2 x Switch fabric-2 module\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e4 x 2520W DC Power Supply\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e1 x fan tray\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eall necessary blank panels\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n[\/shortdesc]\u003c\/div\u003e\n\u003cp\u003e[properties]\u003c\/p\u003e\n\u003ctable width=\"560\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd width=\"218\"\u003eProperties\u003c\/td\u003e\n\u003ctd width=\"342\"\u003eJuniper EX9204-RED3B-DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"218\"\u003eDescription\u003c\/td\u003e\n\u003ctd width=\"342\"\u003eRedundant EX9204 system configuration: 4-slot chassis with passive midplane and 1x fan tray, 2x EX9200-RE2 Routing Engines, 2x Switch Fabric-2 modules, 4x 2,520W DC PSUs, and all necessary blank panels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"218\"\u003eProduct Family\u003c\/td\u003e\n\u003ctd\u003eEX9200 Series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"218\"\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eEthernet Switch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"218\"\u003eTotal number of slots\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"218\"\u003eSlots available for line cards\u003c\/td\u003e\n\u003ctd\u003e2 with fabric redundancy (3 without)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"218\"\u003eRouting Engine\u003c\/td\u003e\n\u003ctd\u003e2x EX9200-RE2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"218\"\u003eSwitch Fabric Module\u003c\/td\u003e\n\u003ctd\u003e2x EX9200-SF2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"560\" colspan=\"2\"\u003eMaximum GbE Port Density (wire speed)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"218\"\u003e1GbE\u003c\/td\u003e\n\u003ctd\u003e120\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"218\"\u003e10GbE\u003c\/td\u003e\n\u003ctd\u003e144 (96)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e25GbE\u003c\/td\u003e\n\u003ctd\u003e120\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"218\"\u003e40GbE\u003c\/td\u003e\n\u003ctd\u003e30\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"218\"\u003e100GbE\u003c\/td\u003e\n\u003ctd\u003e30\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"218\"\u003eFabric\u003c\/td\u003e\n\u003ctd width=\"342\"\u003e• Up to 3 Tbps backplane capacity\u003cbr\u003e• Up to 1.5 Tbps (full duplex) per slot fabric capacity\u003cbr\u003e• 1+1 fabric redundancy\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"218\"\u003eRouting Engine\u003c\/td\u003e\n\u003ctd width=\"342\"\u003e• Master and backup Routing Engines (1+1 redundancy)\u003cbr\u003e• Up to 64 gigabytes DRAM\u003cbr\u003e• Dual front pluggable solid-state drive (SSD) (Up to 64 GB each)\u003cbr\u003e• Console, auxiliary serial, and Ethernet management ports\u003cbr\u003e• USB storage interface\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"218\"\u003eOperating system\u003c\/td\u003e\n\u003ctd width=\"342\"\u003eJuniper Networks Junos operating system\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"218\"\u003ePower\u003c\/td\u003e\n\u003ctd width=\"342\"\u003eHolds up to four power supplies:\u003cbr\u003e• -40 to -72 V DC (1+1 redundancy)\u003cbr\u003eMaximum power draw: 2,199 W (DC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"218\"\u003eCooling\u003c\/td\u003e\n\u003ctd width=\"342\"\u003e• Front-to-back airflow\u003cbr\u003e• Hot-swappable fan tray with 1+1 redundancy\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"218\"\u003eDimensions (W x H x D)\u003c\/td\u003e\n\u003ctd width=\"342\"\u003e17.5 x 8.7 x 27.75 in\u003cbr\u003e(44.5 x 22.1 x 70.5 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"218\"\u003eWeight (fully loaded)\u003c\/td\u003e\n\u003ctd width=\"342\"\u003e128.0 lbs (58.1 Kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"218\"\u003eRack units\u003c\/td\u003e\n\u003ctd\u003e5 U\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003ePower Consumption\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"218\"\u003eEX9204 Redundant Typical Power\u003c\/td\u003e\n\u003ctd\u003e690 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"218\"\u003eEX9204 Redundant Reserved Power\u003c\/td\u003e\n\u003ctd\u003e690 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"218\"\u003eAdditional Units\u003c\/td\u003e\n\u003ctd width=\"342\"\u003eTypical Power\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"218\"\u003eEX9200 Routing Engine-2\u003c\/td\u003e\n\u003ctd\u003e90 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"218\"\u003eEX9200 Switch Fabric-2\u003c\/td\u003e\n\u003ctd\u003e155 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"218\"\u003eAdditional Units\u003c\/td\u003e\n\u003ctd width=\"342\"\u003eMaximum Power\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"218\"\u003eEX9200 Routing Engine-2\u003c\/td\u003e\n\u003ctd\u003e90 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"218\"\u003eEX9200 Switch Fabric-2\u003c\/td\u003e\n\u003ctd\u003e155 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"560\" colspan=\"2\"\u003ePower Supply Capacity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"218\"\u003e100-120V AC Input\u003c\/td\u003e\n\u003ctd width=\"342\"\u003e1,167 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"218\"\u003e200-240 V AC Input\u003c\/td\u003e\n\u003ctd width=\"342\"\u003e2,050 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"218\"\u003e-40 to -72 V DC Input\u003c\/td\u003e\n\u003ctd width=\"342\"\u003e2,400 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"560\" colspan=\"2\"\u003eMaximum number of line cards in a chassis\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"218\"\u003eEX9200-40XS\u003c\/td\u003e\n\u003ctd width=\"342\"\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"218\"\u003eEX9200-15C\u003c\/td\u003e\n\u003ctd width=\"342\"\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"218\"\u003eEX9200-12QS\u003c\/td\u003e\n\u003ctd width=\"342\"\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"218\"\u003eEX9200-32XS\u003c\/td\u003e\n\u003ctd width=\"342\"\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"218\"\u003eEX9200-6QS\u003c\/td\u003e\n\u003ctd width=\"342\"\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"218\"\u003eEX9200-2C-8XS\u003c\/td\u003e\n\u003ctd width=\"342\"\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"218\"\u003eEX9200-40T\u003c\/td\u003e\n\u003ctd width=\"342\"\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"218\"\u003eEX9200-40F\u003c\/td\u003e\n\u003ctd width=\"342\"\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"218\"\u003eEX9200-MPC\u003c\/td\u003e\n\u003ctd width=\"342\"\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e[\/properties]\u003cbr\u003e\u003cbr\u003e[specifications]\u003c\/p\u003e\n\u003ctable width=\"636\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd width=\"257\"\u003eSpecifications\u003c\/td\u003e\n\u003ctd width=\"379\"\u003eEX9204-RED3B-DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"257\"\u003eBackplane capacity\u003c\/td\u003e\n\u003ctd width=\"379\"\u003eUp to 3 Tbps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"257\"\u003eMaximum fabric bandwidth\/slot\u003c\/td\u003e\n\u003ctd width=\"379\"\u003e1.5 Tbps\/slot\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"257\"\u003eSwitch fabric throughput per slot\u003c\/td\u003e\n\u003ctd width=\"379\"\u003e480 Gbps (EX9200-SF2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRE DRAM\u003c\/td\u003e\n\u003ctd\u003e64 GB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRE CPU\u003c\/td\u003e\n\u003ctd\u003e2 GHz, six-core\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRE Storage\u003c\/td\u003e\n\u003ctd\u003e64 GB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" width=\"636\"\u003eSoftware Features\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"257\"\u003eHigh availability\u003c\/td\u003e\n\u003ctd width=\"379\"\u003eHardware designed for continuous operation:\u003cbr\u003e• Secure, modular architecture that isolates faults\u003cbr\u003e• Separate control and forwarding planes that enhance scalability and resiliency\u003cbr\u003e• Transparent failover and network recovery\u003cbr\u003e• Graceful Routing Engine switchover (GRES)\u003cbr\u003e• Nonstop active routing (NSR)\u003cbr\u003e• Nonstop bridging (NSB)\u003cbr\u003e• Unified in-service software upgrade (unified ISSU)*\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"257\"\u003eLayer 2 Features\u003c\/td\u003e\n\u003ctd width=\"379\"\u003eUp to 1 million media access control (MAC) addresses\u003cbr\u003eUp to 512,000 Address Resolution Protocol (ARP) entries with ML license (256,000 entries without ML license)\u003cbr\u003eUp to 512,000 Forwarding Information Block (FIB) entries with ML license (256,000 entries without ML license)\u003cbr\u003eJumbo frames (9,192 bytes maximum)\u003cbr\u003e32,000 VLANs\u003cbr\u003eVLAN Registration Protocol\u003cbr\u003e3ad – Link Aggregation Control Protocol (LACP)\u003cbr\u003e1D – Spanning Tree Protocol (STP)\u003cbr\u003e1w – Rapid Spanning Tree Protocol (RSTP)\u003cbr\u003e1s – Multiple Spanning Tree Protocol (MSTP)\u003cbr\u003eVLAN Spanning Tree Protocol (VSTP)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"257\"\u003eLayer 3 Features\u003c\/td\u003e\n\u003ctd width=\"379\"\u003e1 million IPv4 routing information base (RIB)\u003cbr\u003e1 million IPv6 RIB\u003cbr\u003eStatic routing\u003cbr\u003eRIP v1\/v2\u003cbr\u003eOSPF v1\/v2\u003cbr\u003eOSPF v3\u003cbr\u003eFilter-based forwarding\u003cbr\u003eVirtual Router Redundancy Protocol (VRRP)*\u003cbr\u003eIPv6\u003cbr\u003eBidirectional Forwarding Detection (BFD)\u003cbr\u003eVirtual routers\u003cbr\u003eBGP (Advanced Feature license)\u003cbr\u003eIS-IS (Advanced Feature license)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"257\"\u003eHardware tunneling\u003c\/td\u003e\n\u003ctd width=\"379\"\u003eGRE tunnels\u003cbr\u003eMPLS capabilities (Advanced Feature License)\u003cbr\u003eVPLS\u003cbr\u003eBGP\/MPLS VPNs\u003cbr\u003eEthernet VPNs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"257\"\u003eMulticast\u003c\/td\u003e\n\u003ctd width=\"379\"\u003eUp to 256,000 IPv4 multicast routes\u003cbr\u003eUp to 256,000 IPv6 multicast routes\u003cbr\u003eInternet Group Management Protocol (IGMP) v1\/v2\/v3\u003cbr\u003eIGMP snooping\u003cbr\u003eMLD snooping\u003cbr\u003eProtocol Independent Multicast PIM-SM, PIM-SSM, PIM-DM\u003cbr\u003eMulticast Source Discovery Protocol (MSDP)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"257\"\u003eFirewall filters\u003c\/td\u003e\n\u003ctd width=\"379\"\u003ePort ACLs\u003cbr\u003eVLAN ACLs\u003cbr\u003eRouter ACLs\u003cbr\u003eControl plane denial-of-service (DoS) protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"257\"\u003eQuality of service (QoS)\u003c\/td\u003e\n\u003ctd width=\"379\"\u003e16,000 policers per chassis\u003cbr\u003e8 egress queues per port\u003cbr\u003eWeighted random early detection (WRED) scheduling\u003cbr\u003eWeighted round-robin (WRR) queuing\u003cbr\u003eStrict priority queuing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"257\"\u003eVirtualization\u003c\/td\u003e\n\u003ctd width=\"379\"\u003eIntegration with Juniper Networks Contrail\u003cbr\u003eIntegration with VMware NSX SDN controllers\u003cbr\u003eNetwork virtualization protocols such as Virtual eXtensible LAN (VXLAN) and Open vSwitch Database (OVSDB)\u003cbr\u003eVXLAN Layer 2 and Layer 3 Gateway\u003cbr\u003eEVPN\u003cbr\u003eEVPN Multihoming (EVPN Switch Interface – Link aggregation)\u003cbr\u003eEVPN VXLAN L2 and L3 gateway\u003cbr\u003eVirtual Private LAN Service (VPLS) for Data Center Interconnect\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"257\"\u003eManagement\u003c\/td\u003e\n\u003ctd width=\"379\"\u003eJunos OS command-line interface (CLI)\u003cbr\u003eJunos XML management protocol\u003cbr\u003eSNMP v1\/v2\/v3\u003cbr\u003eRADIUS\u003cbr\u003eTACACS+\u003cbr\u003eExtensive MIB support\u003cbr\u003eFirewall-based port mirroring\u003cbr\u003eLink Layer Discovery Protocol (LLDP)\u003cbr\u003eAdvanced Insight Solutions (AIS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating temperature\u003c\/td\u003e\n\u003ctd\u003e32° to 104° F (0° to 40° C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage temperature\u003c\/td\u003e\n\u003ctd\u003e-40° to 158° F (-40° to 70° C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating altitude\u003c\/td\u003e\n\u003ctd\u003eUp to 10,000 ft (3,048 m)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeismic\u003c\/td\u003e\n\u003ctd\u003eDesigned to meet GR-63, Zone 4 earthquake requirements\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative humidity operating\u003c\/td\u003e\n\u003ctd\u003e5% to 90% (noncondensing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative humidity non-operating\u003c\/td\u003e\n\u003ctd\u003e5 to 95% (noncondensing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"257\"\u003eIEEE Compliance\u003c\/td\u003e\n\u003ctd width=\"379\"\u003eIEEE 802.1AB: Link Layer Discovery Protocol (LLDP)\u003cbr\u003eIEEE 802.1D-2004: Spanning Tree Protocol (STP)\u003cbr\u003eIEEE 802.1p: Class-of-service (CoS) prioritization\u003cbr\u003eIEEE 802.1Q: Virtual Bridged Local Area Networks\u003cbr\u003eIEEE 802.1s: Multiple Spanning Tree Protocol (MSTP)\u003cbr\u003eIEEE 802.1w: Rapid Spanning Tree Protocol (RSTP)\u003cbr\u003eIEEE 802.3: 10BASE-T\u003cbr\u003eIEEE 802.3u: 100BASE-T\u003cbr\u003eIEEE 802.3ab: 1000BASE-T\u003cbr\u003eIEEE 802.3z: 1000BASE-X\u003cbr\u003eIEEE 802.3ae: 10-Gigabit Ethernet\u003cbr\u003eIEEE 802.3ba: 40-Gigabit\/100-Gigabit Ethernet\u003cbr\u003eIEEE 802.3ah: Operation, Administration, and Maintenance (OAM)\u003cbr\u003eIEEE 802.3ad: Link Aggregation Control Protocol (LACP)\u003cbr\u003eIEEE 802.1ae: Media Access Control Security\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"257\"\u003eRFC Compliance\u003c\/td\u003e\n\u003ctd width=\"379\"\u003eRFC 768: UDP\u003cbr\u003eRFC 783: Trivial File Transfer Protocol (TFTP)\u003cbr\u003eRFC 791: IP\u003cbr\u003eRFC 792: Internet Control Message Protocol (ICMP)\u003cbr\u003eRFC 793: TCP\u003cbr\u003eRFC 826: ARP\u003cbr\u003eRFC 854: Telnet client and server\u003cbr\u003eRFC 894: IP over Ethernet\u003cbr\u003eRFC 903: Reverse Address Resolution Protocol (RARP)\u003cbr\u003eRFC 906: TFTP Bootstrap\u003cbr\u003eRFC 951, 1542: BootP\u003cbr\u003eRFC 1027: Proxy ARP\u003cbr\u003eRFC 1058: RIP v1\u003cbr\u003eRFC 1112: IGMP v1\u003cbr\u003eRFC 1122: Host Requirements\u003cbr\u003eRFC 1195: Use of Open Systems Interconnection (OSI) IS-IS for Routing in TCP\/IP and Dual Environments (TCP\/IP transport only)\u003cbr\u003eRFC 1256: IPv4 ICMP Router Discovery Protocol (IRDP)\u003cbr\u003eRFC 1492: TACACS+\u003cbr\u003eRFC 1519: Classless Interdomain Routing (CIDR)\u003cbr\u003eRFC 1587: OSPF NSSA Option\u003cbr\u003eRFC 1591: Domain Name System (DNS)\u003cbr\u003eRFC 1745: BGP4\/IDRP for IP-OSPF Interaction\u003cbr\u003eRFC 1765: OSPF Database Overflow\u003cbr\u003eRFC 1771: Border Gateway Protocol 4\u003cbr\u003eRFC 1772: Application of the Border Gateway Protocol in the Internet\u003cbr\u003eRFC 1812: Requirements for IP Version 4 Routers\u003cbr\u003eRFC 1965: Autonomous System Confederations for BGP\u003cbr\u003eRFC 1981: Path maximum transmission unit (MTU) Discovery for IPv6\u003cbr\u003eRFC 1997: BGP Communities Attribute\u003cbr\u003eRFC 2030: Simple Network Time Protocol (SNTP)\u003cbr\u003eRFC 2068: HTTP server\u003cbr\u003eRFC 2080: RIPng for IPv6\u003cbr\u003eRFC 2081: RIPng Protocol Applicability Statement\u003cbr\u003eRFC 2131: BOOTP\/Dynamic Host Configuration Protocol (DHCP) relay agent* and DHCP server*\u003cbr\u003eRFC 2138: RADIUS Authentication\u003cbr\u003eRFC 2139: RADIUS Accounting\u003cbr\u003eRFC 2154: OSPF with Digital Signatures (password, Message Digest 5)\u003cbr\u003eRFC 2236: IGMP v2\u003cbr\u003eRFC 2267: Network Ingress Filtering\u003cbr\u003eRFC 2270: BGP-4 Dedicated autonomous system (AS) for Sites\/Single Provider\u003cbr\u003eRFC 2283: Multiprotocol Extensions for BGP-4\u003cbr\u003eRFC 2328: OSPF v2 (Edge mode)\u003cbr\u003eRFC 2338: VRRP*\u003cbr\u003eRFC 2362: PIM-SM (Edge mode)\u003cbr\u003eRFC 2370: OSPF Opaque LSA Option\u003cbr\u003eRFC 2373: IPv6 Addressing Architecture\u003cbr\u003eRFC 2375: IPv6 Multicast Address Assignments\u003cbr\u003eRFC 2385: TCP MD5 Authentication for BGPv4\u003cbr\u003eRFC 2439: BGP Route Flap Damping\u003cbr\u003eRFC 2453: RIP v2\u003cbr\u003eRFC 2460: Internet Protocol, v6 (IPv6) specification\u003cbr\u003eRFC 2461: Neighbor Discovery for IP Version 6 (IPv6)\u003cbr\u003eRFC 2462: IPv6 Stateless Address Autoconfiguration\u003cbr\u003eRFC 2463: ICMPv6\u003cbr\u003eRFC 2464: Transmission of IPv6 Packets over Ethernet Networks\u003cbr\u003eRFC 2474: DiffServ Precedence, including 8 queues\/port\u003cbr\u003eRFC 2475: DiffServ Core and Edge Router Functions\u003cbr\u003eRFC 2526: Reserved IPv6 Subnet Anycast Addresses\u003cbr\u003eRFC 2545: Use of BGP-4 Multiprotocol Extensions for IPv6 Interdomain Routing\u003cbr\u003eRFC 2547: BGP\/MPLS VPNs\u003cbr\u003eRFC 2597: DiffServ Assured Forwarding (AF)\u003cbr\u003eRFC 2598: DiffServ Expedited Forwarding (EF)\u003cbr\u003eRFC 2710: Multicast Listener Discovery (MLD) for IPv6\u003cbr\u003eRFC 2711: IPv6 Router Alert Option\u003cbr\u003eRFC 2740: OSPF for IPv6\u003cbr\u003eRFC 2796: BGP Route Reflection (supersedes RFC 1966)\u003cbr\u003eRFC 2796: Route Reflection\u003cbr\u003eRFC 2858: Multiprotocol Extensions for BGP-4\u003cbr\u003eRFC 2893: Transition Mechanisms for IPv6 Hosts and Routers\u003cbr\u003eRFC 2918: Route Refresh Capability for BGP-4\u003cbr\u003eRFC 3031: Multiprotocol Label Switching Architecture\u003cbr\u003eRFC 3032: MPLS Label Stack Encoding\u003cbr\u003eRFC 3036: LDP Specification\u003cbr\u003eRFC 3065: Autonomous System Confederations for BGP\u003cbr\u003eRFC 3176 sFlow\u003cbr\u003eRFC 3215: LDP State Machine\u003cbr\u003eRFC 3306: Unicast-Prefix-based IPv6 Multicast Addresses\u003cbr\u003eRFC 3376: IGMP v3\u003cbr\u003eRFC 3392: Capabilities Advertisement with BGP-4\u003cbr\u003eRFC 3446: Anycast Rendevous Point (RP) Mechanism using PIM and MSDP\u003cbr\u003eRFC 3478: Graceful Restart for Label Distribution Protocol\u003cbr\u003eRFC 3484: Default Address Selection for IPv6\u003cbr\u003eRFC 3513: Internet Protocol Version 6 (IPv6) Addressing\u003cbr\u003eRFC 3569: PIM-SSM PIM Source Specific Multicast\u003cbr\u003eRFC 3587: IPv6 Global Unicast Address Format\u003cbr\u003eRFC 3618: Multicast Source Discovery Protocol (MSDP)\u003cbr\u003eRFC 3623: OSPF Graceful Restart\u003cbr\u003eRFC 3768: Virtual Router Redundancy Protocol (VRRP)*\u003cbr\u003eRFC 3810: Multicast Listener Discovery Version 2 (MLDv2) for IP\u003cbr\u003eRFC 3973: PIM-Dense Mode\u003cbr\u003eRFC 4213: Basic Transition Mechanisms for IPv6 Hosts and Routers\u003cbr\u003eRFC 4291: IPv6 Addressing Architecture\u003cbr\u003eRFC 4360: BGP Extended Communities Attribute\u003cbr\u003eRFC 4364: BGP\/MPLS IP Virtual Private Networks (VPNs)\u003cbr\u003eRFC 4443: ICMPv6 for the IPv6 specification\u003cbr\u003eRFC 4486: Sub codes for BGP Cease Notification message\u003cbr\u003eRFC 4552: Authentication\/Confidentiality for OSPFv3\u003cbr\u003eRFC 4604: Using Internet Group Management Protocol Version 3 (IGMPv3)\u003cbr\u003eRFC 4724: Graceful Restart Mechanism for BGP\u003cbr\u003eRFC 4761: Virtual Private LAN Service (VPLS) using BGP for auto-discovery and signaling\u003cbr\u003eRFC 4798: Connecting IPv6 Islands over IPv4 MPLS Using IPv6 Provider Edge Routers (6PE)\u003cbr\u003eRFC 4861: Neighbor Discovery for IPv6\u003cbr\u003eRFC 4862: IPv6 Stateless Address Autoconfiguration\u003cbr\u003eRFC 5095: Deprecation of Type 0 Routing Headers in IPv6\u003cbr\u003eRFC 5286, Basic Specification for IP Fast Reroute: Loop-Free Alternates\u003cbr\u003eRFC 5306: Restart Signaling for IS-IS\u003cbr\u003eRFC 5308: Routing IPv6 with IS-IS\u003cbr\u003eRFC 5340: OSPF for IPv6\u003cbr\u003eDraft-ietf-bfd-base-09.txt: Bidirectional Forwarding Detection\u003cbr\u003eDraft-ietf-l2vpn-evpn-00.txt: BGP MPLS-based Ethernet VPN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"257\"\u003eServices and Manageability\u003c\/td\u003e\n\u003ctd width=\"379\"\u003eVirtual eXtensible Local Area Network (VXLAN)\u003cbr\u003eREST API\u003cbr\u003eNETCONF sessions over outbound HTTPS\u003cbr\u003eJuniper Extension Toolkit (JET)\u003cbr\u003eOpenFlow v1.3\u003cbr\u003eJunos OS CLI\u003cbr\u003eOut-of-band management: Serial; 10\/100\/1000BASE-T Ethernet\u003cbr\u003eASCII configuration file\u003cbr\u003eRescue configuration\u003cbr\u003eConfiguration rollback\u003cbr\u003eImage rollback\u003cbr\u003eSNMP: v1, v2c, v3\u003cbr\u003eRMON (RFC 2819): Groups 1, 2, 3, 9\u003cbr\u003eNetwork Time Protocol (NTP)\u003cbr\u003eDHCP server\u003cbr\u003eDHCP relay with Option 82\u003cbr\u003eRADIUS\u003cbr\u003eTACACS+\u003cbr\u003eSSHv2\u003cbr\u003eSecure copy\u003cbr\u003eDNS resolver\u003cbr\u003eSyslog logging\u003cbr\u003eEnvironment monitoring\u003cbr\u003eTemperature sensor\u003cbr\u003eConfiguration backup via FTP\/secure copy\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNetwork Management—MIB Support\u003c\/td\u003e\n\u003ctd width=\"379\"\u003eJ-Flow\u003cbr\u003eRFC 1155: Structure of Management Information (SMI)\u003cbr\u003eRFC 1157: SNMPv1\u003cbr\u003eRFC 1212, RFC 1213, RFC 1215: MIB-II, Ethernet-like MIB, and traps\u003cbr\u003eRFC 1657: BGP-4 MIB\u003cbr\u003eRFC 1724: RIPv2 MIB\u003cbr\u003eRFC 1850: OSPFv2 MIB\u003cbr\u003eRFC 1901: Introduction to Community-based SNMPv2\u003cbr\u003eRFC 1902: Structure of Management Information for Version 2 of the Simple Network Management Protocol (SNMPv2)\u003cbr\u003eRFC 1905, RFC 1907: SNMP v2c, SMIv2, and Revised MIB-II\u003cbr\u003eRFC 2011: SNMPv2 for IP using SMIv2\u003cbr\u003eRFC 2012: SNMPv2 for transmission control protocol using SMIv2\u003cbr\u003eRFC 2013: SNMPv2 for user datagram protocol using SMIv2\u003cbr\u003eRFC 2096: IPv4 Forwarding Table MIB\u003cbr\u003eRFC 2287: System Application Packages MIB\u003cbr\u003eRFC 2465: Management Information Base for IP Version 6\u003cbr\u003eRFC 2570–2575: SNMPv3, user-based security, encryption, and authentication\u003cbr\u003eRFC 2576: Coexistence between SNMP Version 1, Version 2, and Version 3\u003cbr\u003eRFC 2578: SNMP Structure of Management Information MIB\u003cbr\u003eRFC 2579: SNMP Textual Conventions for SMIv2\u003cbr\u003eRFC 2665: Ethernet-like interface MIB\u003cbr\u003eRFC 2787: VRRP MIB\u003cbr\u003eRFC 2819: RMON MIB\u003cbr\u003eRFC 2863: Interface Group MIB\u003cbr\u003eRFC 2863: Interface MIB\u003cbr\u003eRFC 2922: LLDP MIB\u003cbr\u003eRFC 2925: Ping\/Traceroute MIB\u003cbr\u003eRFC 2932: IPv4 Multicast MIB\u003cbr\u003eRFC 3413: SNMP Application MIB\u003cbr\u003eRFC 3826: The Advanced Encryption Standard (AES) Cipher Algorithm in the SNMP\u003cbr\u003eRFC 4188: STP and Extensions MIB\u003cbr\u003eRFC 4363: Definitions of Managed Objects for Bridges with traffic classes, multicast filtering, and VLAN extensions\u003cbr\u003eDraft-ietf-idr-bgp4-mibv2-02.txt: Enhanced BGP-4 MIB\u003cbr\u003eDraft-ietf-isis-wg-mib-07\u003cbr\u003eDraft-reeder-snmpv3-usm-3desede-00\u003cbr\u003eDraft-ietf-idmr-igmp-mib-13\u003cbr\u003eDraft-ietf-idmr-pim-mib-09\u003cbr\u003eDraft-ietf-bfd-mib-02.txt\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"257\"\u003eSafety\u003c\/td\u003e\n\u003ctd width=\"379\"\u003eCAN\/CSA-22.2 No. 60950-00\/UL 1950 Third Edition, Safety of Information Technology Equipment\u003cbr\u003eEN 60825-1 Safety of Laser Products—Part 1: Equipment Classification, Requirements, and User’s Guide\u003cbr\u003eEN 60950 Safety of Information Technology Equipment\u003cbr\u003eIEC 60950-1 (2001) Safety of Information Technology Equipment (with country deviations)\u003cbr\u003eEN 60825-1 +A1+A2 (1994) Safety of Laser Products—Part 1: Equipment Classification\u003cbr\u003eEN 60825-2 (2000) Safety of Laser Products—Part 2: Safety of Optical Fiber Comm. Systems\u003cbr\u003eC-UL to CAN\/CSA 22.2 No.60950-1 (Second Edition)\u003cbr\u003eTUV\/GS to EN 60950-1, Amendment A1-A4, A11\u003cbr\u003eCE-IEC60950-1, all country deviations\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"257\"\u003eEMC\u003c\/td\u003e\n\u003ctd width=\"379\"\u003eAS\/NZS CISPR22:2009\u003cbr\u003eEN 55022 2006+A1:2007 European Radiated Emissions\u003cbr\u003eFCC 47CFR , Part 15 Class A (2009) USA Radiated Emissions\u003cbr\u003eVCCI-V-3\/2009.04 and V-4\/2009.04 Japanese Radiated Emissions\u003cbr\u003eBSMI CNS 13438 and NCC C6357 Taiwan Radiated Emissions\u003cbr\u003eEN 300 386 V1.5.1 Telecom Network Equipment - EMC requirements\u003cbr\u003eICES-003 Issue 4, Feb 2004 Canada Radiated Emissions\u003cbr\u003eCISPR 24:1997\/A1:2001\/A2:2002 IT Equipment Immunity Characteristics\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"257\"\u003eImmunity\u003c\/td\u003e\n\u003ctd width=\"379\"\u003eEN 55024:1998\/A1:2001\/A2:2003 Information Technology Equipment Immunity Characteristics\u003cbr\u003eEN-61000-3-2 (2006) Power Line Harmonics\u003cbr\u003eEN-61000-3-3 +A1 +A2 +A3 (1995) Power Line Voltage Fluctuations\u003cbr\u003eEN-61000-4-2 +A1 +A2 (1995) Electrostatic Discharge\u003cbr\u003eEN-61000-4-3 +A1+A2 (2002) Radiated Immunity\u003cbr\u003eEN-61000-4-4 (2004) Electrical Fast Transients\u003cbr\u003eEN-61000-4-5 (2006) Surge\u003cbr\u003eEN-61000-4-6 (2007) Immunity to Conducted Disturbances\u003cbr\u003eEN-61000-4-11 (2004) Voltage Dips and Sags\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"257\"\u003eNetwork Equipment Building System (NEBS)\u003c\/td\u003e\n\u003ctd width=\"379\"\u003eSR-3580 NEBS Criteria Levels (Level 3 Compliance)\u003cbr\u003eGR-63-Core: NEBS, Physical Protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"257\"\u003eEnvironmental\u003c\/td\u003e\n\u003ctd width=\"379\"\u003eReduction of Hazardous Substances (ROHS) 5\/6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"257\"\u003eTelco\u003c\/td\u003e\n\u003ctd width=\"379\"\u003eCommon Language Equipment Identifier (CLEI) code\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e[\/specifications]\u003cbr\u003e\u003cbr\u003e[accesories]\u003c\/p\u003e\n\u003ctable width=\"434\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" width=\"434\"\u003eLine Cards\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"154\"\u003eEX9200-15C\u003c\/td\u003e\n\u003ctd width=\"280\"\u003e15x 100GbE\/40GbE line card with MACsec AES-256 for EX9200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"154\"\u003eEX9200-40XS\u003c\/td\u003e\n\u003ctd width=\"280\"\u003e40-port 10GbE SFP+ line card supporting MACsec AES-256 (requires SFL software license for activation); requires SFP+ optics sold separately\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"154\"\u003eEX9200-12QS\u003c\/td\u003e\n\u003ctd width=\"280\"\u003e12-port 40GbE QSFP+ or 4-port 100GbE QSFP28 combo line card; requires optics sold separately\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"154\"\u003eEX9200-MPC\u003c\/td\u003e\n\u003ctd width=\"280\"\u003eEX9200 Modular Port Concentrator (MPC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"154\"\u003eEX9200-20F-MIC\u003c\/td\u003e\n\u003ctd width=\"280\"\u003eEX9200 20-port GBASE-X (half-slot) Modular Interface Card (MIC) supporting MACsec AES-128 (requires SFL software license for activation); requires EX9200-MPC (ordered separately)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"154\"\u003eEX9200-10XS-MIC\u003c\/td\u003e\n\u003ctd width=\"280\"\u003eEX9200 10-port 10GBASE-X (half-slot) Modular Interface Card (MIC); requires EX9200-MPC (ordered separately)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e[\/accesories]\u003c\/p\u003e\n\u003ch2\u003eJuniper EX9204-RED3B-DC Chassis\u003c\/h2\u003e\n\u003cp\u003eRedundant Juniper EX9204 base chassis configuration with 4-slot passive-midplane system, dual EX9200-RE2 Routing Engines, dual Switch Fabric-2 modules, four 2520W DC power supplies, one fan tray, and all required blank panels.\u003c\/p\u003e","brand":"Juniper","offers":[{"title":"Default Title","offer_id":48958333124864,"sku":"EX9204-RED3B-DC-NEW","price":64665.44,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0388\/5331\/2557\/files\/ex9204_f040f096-9e65-4cbb-962c-1c733ac306f5.jpg?v=1783446557","url":"https:\/\/alotechparts.com\/pt\/products\/juniper-ex9204-red3b-dc-chassis","provider":"Alo Tech Solutions","version":"1.0","type":"link"}