{"product_id":"h2s-a1-alphasense-1-hydrogen-sulfide-sensor","title":"H2S-A1 Alphasense 1% Hydrogen Sulfide Sensor","description":"\u003cp\u003eThe \u003cstrong\u003eH2S-A1 AlphaSense Hydrogen Sulfide Sensor \u003c\/strong\u003e(\u003cem\u003eformerly known as the AP-0006)\u003c\/em\u003e is designed to detect low levels of hydrogen sulfide in ambient air using well-known fuel cell technology.\u003c\/p\u003e\n\u003cp\u003eThis 20mm diameter sensor is the industry standard size for portable gas detectors and also is compatible with the EC board.\u003c\/p\u003e\n\u003cp\u003e\u003cspan data-teams=\"true\"\u003e\u003ci\u003e\u003cstrong\u003eNote: Once an electrochemical (EC) sensor is purchased from CO2Meter.com and the sealed packaging is opened or the sensor module is installed, it is no longer eligible for return due to the limited operational lifespan that begins upon activation.\u003c\/strong\u003e\u003c\/i\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cspan data-teams=\"true\"\u003e\u003ci\u003e\u003cstrong\u003e\u003cspan style=\"color: rgb(239, 6, 6);\"\u003e*\u003cem\u003e*Please Note: MOQ 10pcs - 2-4 week lead time**\u003c\/em\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/i\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cmeta charset=\"utf-8\"\u003e\u003cstrong\u003eFor Sensor Tube Caps, please look under the \"Accessories\" Tab\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWith very high sensitivity and low zero, accurate and stable readings are possible when measuring current concentration ranges at the parts per million level.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e0 to 100ppm H2S sensor\u003c\/li\u003e\n\u003cli\u003eDoes not require calibration\u003c\/li\u003e\n\u003cli\u003eUp to 2 year lifespan\u003c\/li\u003e\n\u003cli\u003eSmall, compact and maintenance free\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"specifications\"\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMeasuring Gas: Hydrogen Sulfide\u003c\/li\u003e\n\u003cli\u003eSensing Method: Fuel cell\u003c\/li\u003e\n\u003cli\u003eSensivity (nA\/ppm in 20ppm H2S): 550 to 875ppm\u003c\/li\u003e\n\u003cli\u003eResponse time (t90 from zero to 20ppm H2S): \u0026lt; 35 sec.\u003c\/li\u003e\n\u003cli\u003eZero Current (ppm equivalent in zero air) \u0026lt; ± 0.4ppm\u003c\/li\u003e\n\u003cli\u003eResolution (RMS noise ppm equivalent): \u0026lt; 0.05ppm\u003c\/li\u003e\n\u003cli\u003eRange (H2S limit of performance warranty): 100ppm\u003c\/li\u003e\n\u003cli\u003eLinearity (ppm error at full scale): 0 to -4ppm\u003c\/li\u003e\n\u003cli\u003eOvergas limit (maximum ppm for stable response): 500ppm\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWarranty\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e90 Days. See CO2Meter Terms and Conditions\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eReplacement Sensor Cross Reference Chart\u003c\/h3\u003e\n\u003ctable width=\"448\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd width=\"122\"\u003e\u003c\/td\u003e\n\u003ctd width=\"158\"\u003eModel\u003c\/td\u003e\n\u003ctd width=\"168\"\u003ePart Number\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensor Type\u003c\/td\u003e\n\u003ctd\u003e4R H2S\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSemeatech\u003c\/td\u003e\n\u003ctd\u003e4H2S-100\u003c\/td\u003e\n\u003ctd\u003e052-0000-000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRAE\u003c\/td\u003e\n\u003ctd\u003e4H2S-100\u003c\/td\u003e\n\u003ctd\u003e032-0102-000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSolidsense\u003c\/td\u003e\n\u003ctd\u003e4H2S-100\u003c\/td\u003e\n\u003ctd\u003eCLE-0112-402\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCity\u003c\/td\u003e\n\u003ctd\u003e4H CiTiceL\u003c\/td\u003e\n\u003ctd\u003eAC200-800\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensoric\u003c\/td\u003e\n\u003ctd\u003eH2S 3E 100S\u003c\/td\u003e\n\u003ctd\u003e0145-134-30049\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlphasense\u003c\/td\u003e\n\u003ctd\u003e(0-500)\u003c\/td\u003e\n\u003ctd\u003eH2S-A1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMembrapor\u003c\/td\u003e\n\u003ctd\u003en\/a\u003c\/td\u003e\n\u003ctd\u003eH2S\/M-100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDDS\u003c\/td\u003e\n\u003ctd\u003e(0-100)\u003c\/td\u003e\n\u003ctd\u003eGS+4H2S\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"documents\"\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/www.alphasense.com\/wp-content\/uploads\/2022\/09\/Alphasense_H2S-A1_datasheet.pdf\"\u003e\u003cimg alt=\"AlphaSense H2S Sensor Datasheet\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\"\u003e Data Sheet (pdf)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"accessories\"\u003e\n\u003cspan\u003eTube cap adapters easily convert 20mm standard gas sensors from diffusion to sampling sensors. Molded polymer grips sensor for easy fit and removal while maintaining a good seal.\u003c\/span\u003e\u003cbr\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"\/pt\/products\/sensor-tube-cap-adapter?variant=31044017619059\" title=\"Tube cap adapter\"\u003e\u003cstrong\u003eTC-1\u003c\/strong\u003e - 3 mm side mounted ports\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/pt\/products\/sensor-tube-cap-adapter?variant=31044017651827\" title=\"tube cap adapter\"\u003e\u003cstrong\u003eTC-2\u003c\/strong\u003e - 3 mm top mounted ports\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/pt\/products\/sensor-tube-cap-adapter?variant=31044017684595\" title=\"tube cap adapter\"\u003e\u003cstrong\u003eTC-3\u003c\/strong\u003e - 4.5 mm top mounted ports\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003ca href=\"\/pt\/products\/gas-sensor-micro-pump\" title=\"micro-pump kit\"\u003eMicro-Pump Kit\u003c\/a\u003e\u003c\/strong\u003e includes all the tools you need to utilize the tube-cap adapters as part of a sampling sensor system.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003ca href=\"\/pt\/products\/nafion-gas-sample-drying-tubing\" title=\"nafion tubing\"\u003eNafion tubing\u003c\/a\u003e i\u003c\/strong\u003es a highly selective, semi-permeable membrane to water vapor. If gases inside Nafion tubing are wetter than gases surrounding the tubing, drying will occur. If the surrounding gases are wetter, humidification will occur.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003ca href=\"\/pt\/products\/gas-sampling-pump\" title=\"gas sampling pump\"\u003eMicro gas sampling pumps\u003c\/a\u003e\u003c\/strong\u003e provide a constant flow of air across the sensor with a tube cap - perfect for bench-top testing of sensors for closed-loop sampling applications.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSensor Pin Sockets\u003c\/strong\u003e - Manufacturers do not recommend soldering to the pins. Pin sockets can be purchased from Andon distributors. \u003ca title=\"pin socket for sensor\" href=\"http:\/\/www.andonelect.com\/prod\/Gas-Sensor-Sockets_64.aspx\"\u003eClick here to search for your sensor's socket\u003c\/a\u003e. Select the brand PDF, find your sensor, then search for the Andon part number for your sensor's socket.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"AlphaSense","offers":[{"title":"H2S-A1 Alphasense Hydrogen Sulfide Sensor","offer_id":49030519619840,"sku":"H2S-A1","price":257.4,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0388\/5331\/2557\/files\/H2S-A1Shopify800x800.jpg?v=1784471301","url":"https:\/\/alotechparts.com\/pt\/products\/h2s-a1-alphasense-1-hydrogen-sulfide-sensor","provider":"Alo Tech Solutions","version":"1.0","type":"link"}