{"product_id":"070-8-0001-tsense-touch-screen-co2-rht-transmitter","title":"070-8-0001 tSense Touch Screen CO2 + RH\/T Transmitter","description":"\u003cp\u003eThe\u003cspan style=\"color: #115e67;\"\u003e \u003cstrong\u003e070-8-0001 tSense Touch Screen CO2 + RH\/T Transmitter\u003c\/strong\u003e\u003c\/span\u003e \u003cstrong\u003e\u003c\/strong\u003e(\u003cem\u003eformerly known as the SE-0034) and the \u003cspan style=\"color: #115e67;\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e070-8-0002 tSense No Display CO2 + RH\/T Transmitter\u003c\/strong\u003e\u003c\/span\u003e (Formerly known as the SE-0035) \u003c\/em\u003eis an attractive, wall-mounted carbon dioxide concentration, temperature, and relative humidity transmitter. It is available with (\u003cmeta charset=\"utf-8\"\u003e070-8-0001) or without (\u003cmeta charset=\"utf-8\"\u003e070-8-0002) an LCD color touch screen display.\u003c\/p\u003e\n\u003ch3\u003eFeatures:\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eCO2, Temperature, and % Relative Humidity\u003c\/li\u003e\n\u003cli\u003eEasy Configuration via LCD Touch Screen\u003c\/li\u003e\n\u003cli\u003eData Logging Capabilities\u003c\/li\u003e\n\u003cli\u003eAll Industry-Standard Outputs\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eABOUT CO2 STORAGE SAFETY CODES\u003c\/h3\u003e\n\u003cp\u003eThis device will \u003cspan style=\"text-decoration: underline; color: #f11111;\"\u003e\u003cstrong\u003eNOT\u003c\/strong\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003emeet requirements for CO2 monitoring in the NBIC, NFPA, or IFC regulations. Refer to our\u003cspan\u003e \u003c\/span\u003e\u003ca title=\"CO2 Safety Products Page\" href=\"\/pt\/collections\/safety-products\"\u003eCO2 Safety Products\u003c\/a\u003e\u003cspan\u003e \u003c\/span\u003epage for devices that meet your needs.\u003c\/p\u003e\n\u003cp\u003eCall us at (877) 678-4259 toll-free or\u003cspan\u003e \u003c\/span\u003e\u003ca href=\"\/pt\/pages\/contact\"\u003eemail us\u003c\/a\u003e to speak with our technical sales team about purchasing the correct device. \u003c\/p\u003e\n\u003cdiv class=\"specifications\"\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas Sensing Method: \u003c\/strong\u003eNon-dispersive Infrared\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGases Measured: \u003c\/strong\u003eCarbon Dioxide, Temperature, and Humidity\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong data-mce-fragment=\"1\"\u003eGas Measurement Range: \u003c\/strong\u003e0-2,000 ppm CO2, 0-50°C, ±5% RH\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccuracy (CO2):\u003c\/strong\u003e ±30ppm ±3% of reading\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions:\u003c\/strong\u003e 125mm x 85mm x 22mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions (display):\u003c\/strong\u003e 49mm x 37mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLife expectancy:\u003c\/strong\u003e \u0026gt;15 years\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperation Temperature:\u003c\/strong\u003e 0 - 50°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSensor Life Expectancy:\u003c\/strong\u003e 15 years\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eABC (Automatic Background Calibration) is enabled but can be used programmed\/disabled\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOutputs\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eOUT1 CO2 0-10VDC, 0-2000ppm\u003c\/li\u003e\n\u003cli\u003eOUT2 Temperature 0-10VDC, 0-50°C\u003c\/li\u003e\n\u003cli\u003eOUT3 Relative Humidity 0-10VDC, 0-100%RH\u003c\/li\u003e\n\u003cli\u003eModbus over RS485\u003c\/li\u003e\n\u003cli\u003eProgrammable Relay\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eElectrical Requirements\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e12VDC \/ 24 \u003cspan class=\"caps\"\u003eVAC\u003c\/span\u003e\/\u003cspan class=\"caps\"\u003eVDC\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWarranty\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e5 years - See \u003ca title=\"View CO2Meter Terms and Conditions\" href=\"https:\/\/www.co2meter.com\/pages\/terms-conditions\"\u003e\u003cspan style=\"text-decoration: underline;\"\u003e\u003cstrong\u003eCO2Meter Terms and Conditions\u003c\/strong\u003e\u003c\/span\u003e\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"accessories\"\u003e\n\u003ch3\u003eAccessories\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/www.co2meter.com\/pages\/contact\" title=\"Call Sales Directly for Cable Purchasing\" target=\"_blank\"\u003eContact Us\u003c\/a\u003e for Cable: CBL-0022\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"documents\"\u003e\n\u003ch3\u003eDocuments\u003c\/h3\u003e\n\u003cp\u003e\u003ca title=\"tSense_Touch_Screen_CO2-RH-T_Transmitter_SE-0034SE-0035_Data_Sheet\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/tSense_Touch_Screen_CO2-RH-T_Transmitter_SE-0034SE-0035_Data_Sheet.pdf?v=1752675919\"\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1094\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\"\u003e Data Sheet (pdf)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/rmtplusstoragesenseair.blob.core.windows.net\/docs\/publicerat\/UMA176.pdf\"\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1094\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\"\u003e Manual (pdf)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/rmtplusstoragesenseair.blob.core.windows.net\/docs\/publicerat\/IMA286.pdf\"\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1094\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\"\u003e Installation Procedure (pdf)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/AN_SE_0034_Modbus_Protocol_Revised8.pdf?v=1653504058\"\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1094\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\"\u003e Modbus Protocol (pdf)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/AN_SE_0034_BACnet_Protocol_Revised8.pdf?v=1653504088\"\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1094\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\"\u003e BACnet Protocol (pdf)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"software\"\u003e\n\u003ch3\u003eSoftware\u003c\/h3\u003e\n\u003ca href=\"https:\/\/senseair.com\/support\/download\/software\/\" target=\"_blank\"\u003eClick here to download UIP software\u003c\/a\u003e\n\u003c\/div\u003e","brand":"Senseair","offers":[{"title":"070-8-0001: tSense CO2 Transmitter w. Display","offer_id":49030528401664,"sku":"070-8-0001","price":790.35,"currency_code":"USD","in_stock":true},{"title":"070-8-0002: tSense CO2 Transmitter no Display","offer_id":49030528434432,"sku":"070-8-0002","price":724.35,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0388\/5331\/2557\/files\/070-8-0001-SALE.jpg?v=1784471427","url":"https:\/\/alotechparts.com\/pt\/products\/070-8-0001-tsense-touch-screen-co2-rht-transmitter","provider":"Alo Tech Solutions","version":"1.0","type":"link"}