{"product_id":"planet-igs-4215-16t2s-u-ip30-industrial-l2l4-16-port-101001000t-2-port-1001000","title":"Planet IGS-4215-16T2S-U IP30 Industrial L2\/L4 16-Port 10\/100\/1000T + 2-Port 100\/1000","description":"\u003cp\u003e\u003cstrong\u003eCost-effective Full Solution Ideal for Hardened Environment\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eDesigned to be installed in heavy industrial demanding environments, the IGS-4215-16T2S \/ IGS-4215-16T2S-U is the new member of PLANET Industrial-grade, DIN-rail type\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eL2\/L4 Managed Gigabit Switch\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efamily to improve the availability of critical business applications. It provides IPv6\/IPv4 dual stack management and built-in L2\/L4 Gigabit switching engine along with\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e16 10\/100\/1000BASE-T\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eports, and\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e2 extra 100\/1000BASE-X SFP fiber slots\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor data and video uplink. The IGS-4215-16T2S \/ IGS-4215-16T2S-U is able to operate reliably, stably and quietly in any hardened environment without affecting its performance. It comes with operating temperature ranging from -40 to 75 degrees C in a rugged IP30 metal housing.\u003c\/p\u003e\n\u003cp\u003e\u003cimg class=\"img-fluid\" height=\"400\" width=\"1000\" alt=\"\" src=\"https:\/\/planet.com.tw\/storage\/products\/49305\/edm_IGS-4215-16T2S.jpg\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cimg class=\"img-fluid\" height=\"427\" width=\"700\" src=\"https:\/\/planet.com.tw\/storage\/products\/49305\/IGS-4215-16T2S_Front-Panel-Introduction.png\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e  \u003cbr\u003e \u003cbr\u003e\u003cimg class=\"img-fluid\" height=\"524\" width=\"692\" alt=\"\" src=\"https:\/\/planet.com.tw\/storage\/products\/49305\/IGS-4215-16T2S-U_Front-Panel-Introducton.png\"\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eEnvironmentally Hardened Design\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWith the IP30 industrial case, the IGS-4215-16T2S \/ IGS-4215-16T2S-U provides a high level of immunity against electromagnetic interference and heavy electrical surges which are usually found on plant floors or in curb-side traffic control cabinets without air conditioner. Being able to operate under the temperature range from -40 to 75 degrees C, the IGS-4215-16T2S \/ IGS-4215-16T2S-U can be placed in almost any difficult environment.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRobust Protection\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe IGS-4215-16T2S \/ IGS-4215-16T2S-U provides contact discharge of ±6KV DC and air discharge of ±8KV DC for Ethernet ESD protection. It also supports ±4KV surge immunity to improve product stability and protects users’ networks from devastating ESD attacks, making sure the flow of operation does not fluctuate.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRedundant Ring, Fast Recovery for Critical Network Applications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe IGS-4215-16T2S \/ IGS-4215-16T2S-U supports redundant ring technology and features strong, rapid self-recovery capability to prevent interruptions and external intrusions. It incorporates advanced\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eITU-T G.8032 ERPS (Ethernet Ring Protection Switching)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003etechnology, Spanning Tree Protocol (802.1s MSTP) into customer’s network to enhance system reliability and uptime in various environments.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRobust Layer 2 Features\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe IGS-4215-16T2S \/ IGS-4215-16T2S-U can be programmed for advanced switch management functions such as dynamic port link aggregation, 802.1Q VLAN,\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eQ-in-Q VLAN, Multiple Spanning Tree Protocol (MSTP)\u003c\/strong\u003e,\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eloop\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBPDU guard, IGMP snooping\u003c\/strong\u003e, and\u003cstrong\u003e\u003cspan\u003e \u003c\/span\u003eMLD snooping\u003c\/strong\u003e. Via the link aggregation, the IGS-4215-16T2S \/ IGS-4215-16T2S-U allows the operation of a high-speed trunk to combine with multiple ports such as an 8Gbps fat pipe, and supports fail-over as well.  Also, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eLink Layer\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eDiscovery Protocol (LLDP)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis the Layer 2 protocol included to help discover basic information about neighboring devices on the local broadcast domain.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cimg class=\"img-fluid\" height=\"217\" width=\"700\" alt=\"\" src=\"https:\/\/planet.com.tw\/storage\/products\/49305\/Common_Robust-Layer-2-Features.png\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIPv6\/IPv4 Dual Stack Management\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eSupporting both IPv6 and IPv4 protocols, the IGS-4215-16T2S \/ IGS-4215-16T2S-U helps the SMBs to step in the IPv6 era with the lowest investment as its network facilities need not be replaced or overhauled if the IPv6 FTTx edge network is set up.\u003c\/p\u003e\n\u003cp\u003e\u003cimg class=\"img-fluid\" height=\"388\" width=\"701\" alt=\"\" src=\"https:\/\/planet.com.tw\/storage\/products\/49305\/Common_IPv6_IPv4-Dual-Stack-Management.png\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eEfficient Traffic Control\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe IGS-4215-16T2S \/ IGS-4215-16T2S-U is loaded with robust QoS features and powerful traffic management to enhance services to business-class data, voice, and video solutions. The functionality includes broadcast\/multicast\/unicast\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003estorm control\u003c\/strong\u003e, per port\u003cstrong\u003e\u003cspan\u003e \u003c\/span\u003ebandwidth control\u003c\/strong\u003e, 802.1p\/CoS\/IP DSCP QoS priority and remarking. It guarantees the best performance in VoIP and video stream transmission, and empowers the enterprises to take full advantage of the limited network resources.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eUser-friendly and Secure Management \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe IGS-4215-16T2S \/ IGS-4215-16T2S-U comes with enhanced cybersecurity to fend off cyberthreats and cyberattacks. It supports\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSSHv2\u003c\/strong\u003e,\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eTLSv1.2\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSNMPv3\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eprotocols to provide strong protection against advanced threats. Served as a key point to transmit data, the cybersecurity feature of the IGS-4215-16T2S \/ IGS-4215-16T2S-U protects the switch management and enhances the security of the mission-critical network without any extra deployment cost and effort.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cimg class=\"img-fluid\" height=\"137\" width=\"700\" alt=\"\" src=\"https:\/\/planet.com.tw\/storage\/products\/49305\/Common_Secure-Management.png\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePowerful Security\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003ePLANET IGS-4215-16T2S \/ IGS-4215-16T2S-U offers comprehensive\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIPv4\/IPv6\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eLayer 2 to Layer 4\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAccess Control List (ACL)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor enforcing security to the edge. It can be used to restrict network access by denying packets based on source and destination IP address, TCP\/UDP ports or defined typical network applications. Its protection mechanism also comprises\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e802.1X port-based\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003euser and device authentication, which can be deployed with RADIUS to ensure the port level security and block illegal users. With the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eProtected Port\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efunction, communication between edge ports can be prevented to guarantee user privacy. Furthermore,\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ePort Security\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efunction allows limiting the number of network devices on a given port. \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAdvanced Network Security \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe IGS-4215-16T2S \/ IGS-4215-16T2S-U also provides\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eDHCP Snooping\u003c\/strong\u003e,\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIP Source Guard\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eDynamic ARP Inspection\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efunctions to prevent IP snooping from attack and discard ARP packets with invalid MAC address. The network administrators can now construct highly-secure corporate networks with considerably less time and effort than before.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRemote Management Solution\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003ePLANET's\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eUniversal Network Management System\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(UNI-NMS) and\u003cstrong\u003e\u003cspan\u003e \u003c\/span\u003eCloudViewer app\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003esupport IT staff by remotely managing all network devices and monitoring PDs' operational statuses. Thus, they're designed for both the enterprises and industries where deployments of PDs can be as remote as possible, without having to go to the actual location once a bug or faulty condition is found. With the UNI-NMS or CloudViewer app, all kinds of businesses can now be speedily and efficiently managed from one platform.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cimg class=\"img-fluid\" height=\"376\" width=\"700\" alt=\"\" src=\"https:\/\/planet.com.tw\/storage\/products\/49305\/XGS-6320-8X8TR_XGS-6320-12X4TR-4.png\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFlexibility and Long-distance Extension Solution\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe two additional SFP slots built in the IGS-4215-16T2S \/ IGS-4215-16T2S-U support 100BASE-FX \/1000BASE-SX\/LX SFP (Small Form-factor Pluggable) fiber transceivers to uplink to backbone switch in long distance. The distance can be extended from 550 meters to 2 kilometers (multi-mode fiber) and up to 120 kilometers (single-mode fiber or WDM fiber). They are well suited for applications within the enterprise data centers and distributions.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cimg class=\"img-fluid\" height=\"229\" width=\"700\" alt=\"\" src=\"https:\/\/planet.com.tw\/storage\/products\/49305\/IGS-4215-16T2S-7.png\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIntelligent SFP Diagnosis Mechanism\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe IGS-4215-16T2S \/ IGS-4215-16T2S-U\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003esupports SFP-DDM (Digital Diagnostic Monitor)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efunction that can easily monitor real-time parameters of the SFP for the network administrator, such as optical output power, optical input power, temperature, laser bias current, and transceiver supply voltage.\u003c\/p\u003e\n\u003cp\u003e\u003cimg class=\"img-fluid\" height=\"350\" width=\"700\" alt=\"\" src=\"https:\/\/planet.com.tw\/storage\/products\/49305\/Common_Intelligent-SFP_SFP+-Diagnosis-Mechanism.png\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePhysical Port\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e16-port 10\/100\/1000BASE-T RJ45 with auto MDI\/MDI-X function \u003c\/li\u003e\n\u003cli\u003e2 SFP interfaces, supporting 100\/1000BASE-X SFP transceiver type auto detection \u003c\/li\u003e\n\u003cli\u003e1-port RJ45 console for basic management and setup (IGS-4215-16T2S only)\u003c\/li\u003e\n\u003cli\u003e1-port USB console for basic management and setup (IGS-4215-16T2S-U only)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eIndustrial Case and Installation\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eDual power input, redundant power with reverse polarity protection\n\u003cul\u003e\n\u003cli\u003eDC 12 to 48V input or AC 24V input (IGS-4215-16T2S only)\u003c\/li\u003e\n\u003cli\u003eDC 9 to 48V input or AC 24V input (IGS-4215-16T2S-U only)\u003c\/li\u003e\n\u003cli\u003eActive-active redundant power failure protection\u003c\/li\u003e\n\u003cli\u003eBackup of catastrophic power failure on one supply\u003c\/li\u003e\n\u003cli\u003eFault tolerance and resilience\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eIP30 metal case\u003c\/li\u003e\n\u003cli\u003eDIN-rail and wall-mount designs\u003c\/li\u003e\n\u003cli\u003eSupports ESD 6KV DC Ethernet protection \u003c\/li\u003e\n\u003cli\u003eSupports -40 to 75 degrees C operating temperature\u003c\/li\u003e\n\u003cli\u003eFree fall, shock-proof and vibration-proof for industries\u003c\/li\u003e\n\u003cli\u003eFanless design\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eSwitching\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eFeatures Store-and-Forward mode with wire-speed filtering and forwarding rates\u003c\/li\u003e\n\u003cli\u003eIEEE 802.3x flow control for full duplex operation and back pressure for half duplex operation\u003c\/li\u003e\n\u003cli\u003e8K MAC address table size\u003c\/li\u003e\n\u003cli\u003e10K jumbo frame\u003c\/li\u003e\n\u003cli\u003eAutomatic address learning and address aging\u003c\/li\u003e\n\u003cli\u003eSupports CSMA\/CD protocol\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eLayer 2 Features\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSupports\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eVLAN\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eIEEE 802.1Q tagged VLAN\u003c\/li\u003e\n\u003cli\u003eUp to 256 VLAN groups, out of 4096 VLAN IDs\u003c\/li\u003e\n\u003cli\u003eProvider bridging (VLAN Q-in-Q, IEEE 802.1ad) support\u003c\/li\u003e\n\u003cli\u003ePrivate VLAN (Protected port)\u003c\/li\u003e\n\u003cli\u003eProtocol-based VLAN\u003c\/li\u003e\n\u003cli\u003eVoice VLAN\u003c\/li\u003e\n\u003cli\u003eGVRP\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eSupports\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSpanning Tree Protocol\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eIEEE 802.1D Spanning Tree Protocol (STP)\u003c\/li\u003e\n\u003cli\u003eIEEE 802.1w Rapid Spanning Tree Protocol (RSTP)\u003c\/li\u003e\n\u003cli\u003eIEEE 802.1s Multiple Spanning Tree Protocol (MSTP), spanning tree by VLAN\u003c\/li\u003e\n\u003cli\u003eBPDU Guard\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eSupports\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eLink Aggregation\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eIEEE 802.3ad Link Aggregation Control Protocol (LACP)\u003c\/li\u003e\n\u003cli\u003eCisco ether-channel (static trunk)\u003c\/li\u003e\n\u003cli\u003eUp to 8 trunk groups\u003c\/li\u003e\n\u003cli\u003eUp to 8 ports per trunk group with 16Gbps bandwidth\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eProvides port mirror (many-to-1)\u003c\/li\u003e\n\u003cli\u003eIPv6 MAC\/VLAN\/Multicast Address Table\u003c\/li\u003e\n\u003cli\u003eLoop protection to avoid broadcast loops\u003c\/li\u003e\n\u003cli\u003eSupports ERPS (Ethernet Ring Protection Switching)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eQuality of Service\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eIngress\/Egress Rate Limit per port bandwidth control\u003c\/li\u003e\n\u003cli\u003eSupport 8 priority queues on all switch ports\u003c\/li\u003e\n\u003cli\u003eTraffic classification\n\u003cul\u003e\n\u003cli\u003eIEEE 802.1p CoS\u003c\/li\u003e\n\u003cli\u003eIP TOS\/DSCP\/IP precedence of IPv4\/IPv6 packets\u003c\/li\u003e\n\u003cli\u003eIP TCP\/UDP port number\u003c\/li\u003e\n\u003cli\u003eTypical network application\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eDSCP remarking\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eMulticast\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSupports IPv4 IGMP snooping v1, v2, v3\u003c\/li\u003e\n\u003cli\u003eSupports IPv6 MLD snooping v1, v2\u003c\/li\u003e\n\u003cli\u003eQuerier mode support\u003c\/li\u003e\n\u003cli\u003eIGMP snooping port filtering\u003c\/li\u003e\n\u003cli\u003eMLD snooping port filtering\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eSecurity\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eStorm Control support\n\u003cul\u003e\n\u003cli\u003eBroadcast\/Multicast\/Unicast\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eAuthentication\n\u003cul\u003e\n\u003cli\u003eIEEE 802.1X port-based network access authentication\u003c\/li\u003e\n\u003cli\u003eBuilt-in RADIUS client to cooperate with the RADIUS servers\u003c\/li\u003e\n\u003cli\u003eDHCP Relay and DHCP Option 82\u003c\/li\u003e\n\u003cli\u003eRADIUS\/TACACS+ users access authentication\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eAccess Control List\n\u003cul\u003e\n\u003cli\u003eIPv4\/IPv6 IP-based ACL\u003c\/li\u003e\n\u003cli\u003eIPv4\/IPv6 IP-based ACE\u003c\/li\u003e\n\u003cli\u003eMAC-based ACL\u003c\/li\u003e\n\u003cli\u003eMAC-based ACE\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eMAC Security\n\u003cul\u003e\n\u003cli\u003eStatic MAC\u003c\/li\u003e\n\u003cli\u003eMAC filtering\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003ePort security for source MAC address entries filtering\u003c\/li\u003e\n\u003cli\u003eDHCP snooping to filter distrusted DHCP messages\u003c\/li\u003e\n\u003cli\u003eDynamic ARP inspection discards ARP packets with invalid MAC address to IP address binding\u003c\/li\u003e\n\u003cli\u003eIP source guard prevents IP spoofing attacks\u003c\/li\u003e\n\u003cli\u003eIP address access management to prevent unauthorized intruder\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eManagement\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eIPv4 and IPv6 dual stack management\u003c\/li\u003e\n\u003cli\u003eSwitch Management Interface\n\u003cul\u003e\n\u003cli\u003eIPv4\/IPv6 Web switch management \u003c\/li\u003e\n\u003cli\u003eConsole and telnet Command Line Interface\u003c\/li\u003e\n\u003cli\u003eSNMP v1 and v2c switch management\u003c\/li\u003e\n\u003cli\u003eSSHv2, TLSv1.2 and SNMP v3 secure access\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eIPv6 IP address\/NTP\/DNS management\u003c\/li\u003e\n\u003cli\u003eBuilt-in Trivial File Transfer Protocol (TFTP) client\u003c\/li\u003e\n\u003cli\u003eStatic and DHCP for IP address assignment\u003c\/li\u003e\n\u003cli\u003eSystem Maintenance\n\u003cul\u003e\n\u003cli\u003eFirmware upload\/download via HTTP\/TFTP\u003c\/li\u003e\n\u003cli\u003eHardware reset button for system reboot or reset to factory default \u003c\/li\u003e\n\u003cli\u003eDual images\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eUser Privilege levels control\u003c\/li\u003e\n\u003cli\u003eNetwork Time Protocol (NTP)\u003c\/li\u003e\n\u003cli\u003eLink Layer Discovery Protocol (LLDP) and LLDP-MED\u003c\/li\u003e\n\u003cli\u003eSyslog remote alarm\u003c\/li\u003e\n\u003cli\u003eSNMP Management\n\u003cul\u003e\n\u003cli\u003eSNMP trap for interface link up and link down notification\u003c\/li\u003e\n\u003cli\u003eFour RMON groups (history, statistics, alarms and events)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003ePLANET Smart Discovery Utility for deployment management\u003c\/li\u003e\n\u003cli\u003ePLANET NMS system and CloudViewer for deployment management\u003c\/li\u003e\n\u003cli\u003eNetwork diagnostic\n\u003cul\u003e\n\u003cli\u003eSFP-DDM (Digital Diagnostic Monitor)\u003c\/li\u003e\n\u003cli\u003eCable diagnostic technology provides the mechanism to detect and report potential cabling issues\u003c\/li\u003e\n\u003cli\u003eICMPv6 \/ ICMPv4 remote ping\u003c\/li\u003e\n\u003cli\u003eLive remote checking is designed to make sure the devices are still connected\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ctable class=\"table table-sm table-bordered-bone table-striped-blue table-header-theme-blue table-header-no-border\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\"\u003eHardware Specifications\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eCopper Ports\u003c\/td\u003e\n\u003ctd\u003e16 10\/100\/1000BASE-T RJ45 auto-MDI\/MDI-X ports\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eGigabit SFP Slots\u003c\/td\u003e\n\u003ctd\u003e2 100\/1000BASE-SX\/LX\/BX SFP interfaces\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eConsole\u003c\/td\u003e\n\u003ctd\u003e\n\u003cb\u003eIGS-4215-16T2S：\u003c\/b\u003e1 RJ45 serial port (115200,8, N, 1)\u003cbr\u003e\u003cb\u003eIGS-4215-16T2S-U：\u003c\/b\u003e1 Micro-USB female port (115200,8, N, 1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eRAM\u003c\/td\u003e\n\u003ctd\u003e128Mbytes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eFlash Memory\u003c\/td\u003e\n\u003ctd\u003e16Mbytes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eReset Button\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 5 sec: System reboot\u003cbr\u003e\u0026gt; 5 sec: Factory default\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eConnector\u003c\/td\u003e\n\u003ctd\u003eRemovable 6-pin terminal block for power input\u003cbr\u003e　Pin 1\/2 for Power 1\u003cbr\u003e　Pin 3\/4 for fault alarm\u003cbr\u003e　Pin 5\/6 for Power 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eAlarm\u003c\/td\u003e\n\u003ctd\u003eOne relay output for power failure.\u003cbr\u003eAlarm relay current carry ability: 1A @ 24V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003ePower Requirements\u003c\/td\u003e\n\u003ctd\u003e\n\u003cb\u003eIGS-4215-16T2S：\u003c\/b\u003e\u003cbr\u003eDual 12~48V DC\u003cbr\u003e24V AC\u003cbr\u003e\u003cb\u003eIGS-4215-16T2S-U：\u003c\/b\u003e\u003cbr\u003eDual 9~48V DC\u003cbr\u003e24V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e\n\u003cb\u003eIGS-4215-16T2S：\u003c\/b\u003e\u003cbr\u003eDC input:\u003cbr\u003eMax. 3.4 watts\/11.6BTU (System on)\u003cbr\u003eMax. 12.5 watts\/42.7BTU (Full loading)\u003cbr\u003e\u003cbr\u003eAC input:\u003cbr\u003eMax. 6 watts\/20.5BTU (System on)\u003cbr\u003eMax. 15 watts\/51.2BTU (Full loading)\u003cbr\u003e\u003cbr\u003e\u003cb\u003eIGS-4215-16T2S-U：\u003c\/b\u003e\u003cbr\u003eDC input:\u003cbr\u003eMax. 3.31 watts\/11.3BTU (System on)\u003cbr\u003eMax.10.41 watts\/35.5BTU (Full loading)\u003cbr\u003e\u003cbr\u003eAC input:\u003cbr\u003eMax. 3 watts\/10.2BTU (System on)\u003cbr\u003eMax. 10 watts\/34.1BTU (Full loading)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eDimensions (W x D x H)\u003c\/td\u003e\n\u003ctd\u003e66 x 107 x 152 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e\n\u003cb\u003eIGS-4215-16T2S：\u003c\/b\u003e813g\u003cbr\u003e\u003cb\u003eIGS-4215-16T2S-U：\u003c\/b\u003e829g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eEnclosure\u003c\/td\u003e\n\u003ctd\u003eIP30 metal case\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eInstallation\u003c\/td\u003e\n\u003ctd\u003eDIN-rail kit and wall-mount ear\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eESD Protection\u003c\/td\u003e\n\u003ctd\u003e6KV DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eLED\u003c\/td\u003e\n\u003ctd\u003e\n\u003cb\u003eSystem\u003c\/b\u003e\u003cbr\u003e　\u003cspan style=\"color: green;\"\u003e\u003cb\u003eGreen\u003c\/b\u003e\u003c\/span\u003e: Power 1\u003cbr\u003e　\u003cspan style=\"color: green;\"\u003e\u003cb\u003eGreen\u003c\/b\u003e\u003c\/span\u003e: Power 2\u003cbr\u003e　\u003cspan style=\"color: red;\"\u003e\u003cb\u003eRed\u003c\/b\u003e\u003c\/span\u003e: Power Fault\u003cbr\u003e\u003cb\u003ePer 10\/100\/1000T RJ45 Ports\u003c\/b\u003e\u003cbr\u003e　\u003cspan style=\"color: green;\"\u003e\u003cb\u003eGreen\u003c\/b\u003e\u003c\/span\u003e: 1000 LNK\/ACT\u003cbr\u003e　\u003cspan style=\"color: orange;\"\u003e\u003cb\u003eOrange\u003c\/b\u003e\u003c\/span\u003e: 10\/100 LNK\/ACT\u003cbr\u003e\u003cb\u003ePer SFP Interface\u003c\/b\u003e\u003cbr\u003e　\u003cspan style=\"color: green;\"\u003e\u003cb\u003eGreen\u003c\/b\u003e\u003c\/span\u003e: 1000 LNK\/ACT\u003cbr\u003e　\u003cspan style=\"color: orange;\"\u003e\u003cb\u003eOrange\u003c\/b\u003e\u003c\/span\u003e: 100 LNK\/ACT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\"\u003eSwitching Specifications\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eSwitch Architecture\u003c\/td\u003e\n\u003ctd\u003eStore-and-Forward\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eSwitch Fabric\u003c\/td\u003e\n\u003ctd\u003e36Gbps (non-blocking)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eSwitch Throughput@64 bytes\u003c\/td\u003e\n\u003ctd\u003e26.79Mpps@ 64 bytes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eMAC Address Table\u003c\/td\u003e\n\u003ctd\u003e8K entries\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eShared Data Buffer\u003c\/td\u003e\n\u003ctd\u003e4.1Mbits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eFlow Control\u003c\/td\u003e\n\u003ctd\u003eIEEE 802.3x pause frame for full duplex\u003cbr\u003eBack pressure for half duplex\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eJumbo Frame\u003c\/td\u003e\n\u003ctd\u003e10 Kbytes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\"\u003eLayer 2 Functions\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003ePort Mirroring\u003c\/td\u003e\n\u003ctd\u003eTX\/RX\/Both\u003cbr\u003eMany-to-1 monitor\u003cbr\u003eUp to 4 sessions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eVLAN\u003c\/td\u003e\n\u003ctd\u003e802.1Q tagged-based VLAN\u003cbr\u003eUp to 256 VLAN groups, out of 4094 VLAN IDs\u003cbr\u003e802.1ad Q-in-Q tunneling (VLAN stacking)\u003cbr\u003eVoice VLAN\u003cbr\u003eProtocol VLAN\u003cbr\u003ePrivate VLAN (Protected port)\u003cbr\u003eGVRP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eLink Aggregation\u003c\/td\u003e\n\u003ctd\u003eIEEE 802.3ad LACP and static trunk\u003cbr\u003eCisco ether-channel (Static Trunk)\u003cbr\u003eUp to 8 trunk groups\u003cbr\u003eUp to 8 ports per trunk group with 16Gbps bandwidth\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eSpanning Tree Protocol\u003c\/td\u003e\n\u003ctd\u003eIEEE 802.1D Spanning Tree Protocol (STP)\u003cbr\u003eIEEE 802.1w Rapid Spanning Tree Protocol (RSTP)\u003cbr\u003eIEEE 802.1s Multiple Spanning Tree Protocol (MSTP)\u003cbr\u003eSTP BPDU Guard, BPDU Filtering and BPDU Forwarding\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eIGMP Snooping\u003c\/td\u003e\n\u003ctd\u003eIPv4 IGMP snooping v1, v2, v3\u003cbr\u003eIGMP querier\u003cbr\u003eUp to 256 multicast groups\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eMLD Snooping\u003c\/td\u003e\n\u003ctd\u003eIPv6 MLD snooping v1, v2, up to 256 multicast groups\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eQoS\u003c\/td\u003e\n\u003ctd\u003eIngress\/Egress Rate Limit per port bandwidth control\u003cbr\u003e8-level priority for switching\u003cbr\u003e　Port number\u003cbr\u003e　802.1p priority\u003cbr\u003e　DSCP\/IP precedence of IPv4\/IPv6 packets\u003cbr\u003e　Typical network application\u003cbr\u003eDSCP remarking\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eRing\u003c\/td\u003e\n\u003ctd\u003eSupports ERPS, and complies with ITU-T G.8032\u003cbr\u003eRecovery time \u0026lt; 450ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\"\u003eSecurity Functions\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eAccess Control List\u003c\/td\u003e\n\u003ctd\u003eIPv4\/IPv6 IP-based ACL\/MAC-based ACL\u003cbr\u003eIPv4\/IPv6 IP-based ACE\/MAC-based ACE\u003cbr\u003eMax. 256 ACL entries\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003ePort Security\u003c\/td\u003e\n\u003ctd\u003eIEEE 802.1X – Port-based authentication\u003cbr\u003eBuilt-in RADIUS client to co-operate with RADIUS server\u003cbr\u003eRADIUS\/TACACS+ user access authentication\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eMAC Security\u003c\/td\u003e\n\u003ctd\u003eIP-MAC port binding\u003cbr\u003eMAC filter\u003cbr\u003eStatic MAC address, max. 256 static MAC entries\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eEnhanced Security\u003c\/td\u003e\n\u003ctd\u003eDHCP Snooping and DHCP Option82\u003cbr\u003eSTP BPDU guard, BPDU filtering and BPDU forwarding\u003cbr\u003eDoS attack prevention\u003cbr\u003eARP inspection\u003cbr\u003eIP source guard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\"\u003eManagement Functions\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eBasic Management Interfaces\u003c\/td\u003e\n\u003ctd\u003eConsole; Telnet; Web browser; SNMP v1, v2c\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eSecure Management Interfaces\u003c\/td\u003e\n\u003ctd\u003eSSHv2, TLS v1.2, SNMP v3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eSystem Management\u003c\/td\u003e\n\u003ctd\u003eFirmware upgrade by HTTP protocol through Ethernet network\u003cbr\u003eConfiguration upload\/download through HTTP\u003cbr\u003eRemote Syslog\u003cbr\u003eSystem log\u003cbr\u003eLLDP protocol\u003cbr\u003eSNTP\u003cbr\u003ePLANET Smart Discovery Utility\u003cbr\u003ePLANET NMS System\/CloudViewer app\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eEvent Management\u003c\/td\u003e\n\u003ctd\u003eRemote\/Local Syslog\u003cbr\u003eSystem log\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eSNMP MIBs\u003c\/td\u003e\n\u003ctd\u003eRFC 1213 MIB-II\u003cbr\u003eRFC 1493 Bridge MIB\u003cbr\u003eRFC 1643 Ethernet MIB\u003cbr\u003eRFC 2863 Interface MIB\u003cbr\u003eRFC 2665 Ether-Like MIB\u003cbr\u003eRFC 2819 RMON MIB (Groups 1, 2, 3 and 9)\u003cbr\u003eRFC 2737 Entity MIB\u003cbr\u003eRFC 2618 RADIUS Client MIB\u003cbr\u003eRFC 2863 IF-MIB\u003cbr\u003eRFC 2933 IGMP-STD-MIB\u003cbr\u003eRFC 3411 SNMP-Frameworks-MIB\u003cbr\u003eRFC 4292 IP Forward MIB\u003cbr\u003eRFC 4293 IP MIB\u003cbr\u003eRFC 4836 MAU-MIB\u003cbr\u003eIEEE 802.1X PAE\u003cbr\u003eLLDP\u003cbr\u003eMAU-MIB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\"\u003eStandards Conformance\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eRegulatory Compliance\u003c\/td\u003e\n\u003ctd\u003eFCC Part 15 Class A\u003cbr\u003eEN 55032\u003cbr\u003eEN 55035\u003cbr\u003eICES-003 issue 7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eCertification\u003c\/td\u003e\n\u003ctd\u003eEN50121-4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eStability Testing\u003c\/td\u003e\n\u003ctd\u003eIEC 60068-2-32 (free fall)\u003cbr\u003eIEC 60068-2-27 (shock)\u003cbr\u003eIEC 60068-2-6 (vibration)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eStandards Compliance\u003c\/td\u003e\n\u003ctd\u003eIEEE 802.3 10BASE-T\u003cbr\u003eIEEE 802.3u 100BASE-TX\/100BASE-FX\u003cbr\u003eIEEE 802.3z Gigabit SX\/LX\u003cbr\u003eIEEE 802.3ab Gigabit 1000T\u003cbr\u003eIEEE 802.3x flow control and back pressure\u003cbr\u003eIEEE 802.3ad port trunk with LACP\u003cbr\u003eIEEE 802.1D Spanning Tree Protocol\u003cbr\u003eIEEE 802.1w Rapid Spanning Tree Protocol\u003cbr\u003eIEEE 802.1s Multiple Spanning Tree Protocol\u003cbr\u003eIEEE 802.1p Class of Service\u003cbr\u003eIEEE 802.1Q VLAN tagging\u003cbr\u003eIEEE 802.1x Port Authentication Network Control IEEE 802.1ab LLDP\u003cbr\u003eIEEE 802.3az for Energy-Efficient Ethernet\u003cbr\u003eRFC 768 UDP\u003cbr\u003eRFC 783 TFTP\u003cbr\u003eRFC 791 IP\u003cbr\u003eRFC 792 ICMP\u003cbr\u003eRFC 2068 HTTP\u003cbr\u003eRFC 1112 IGMP v1\u003cbr\u003eRFC 2236 IGMP v2\u003cbr\u003eRFC 3376 IGMP v3\u003cbr\u003eRFC 2710 MLD v1\u003cbr\u003eFRC 3810 MLD v2\u003cbr\u003eITU G.8032 ERPS Ring\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\"\u003eEnvironment\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-40 ~ 75 degrees C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-40 ~ 85 degrees C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eHumidity\u003c\/td\u003e\n\u003ctd\u003e5 ~ 95% (non-condensing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOrdering Information\u003c\/strong\u003e\u003cbr\u003eIGS-4215-16T2S\u003cbr\u003eIndustrial L2\/L4 16-Port 10\/100\/1000T + 2-Port 100\/1000X SFP Managed Switch (-40~75 degrees C)\u003cbr\u003eIGS-4215-16T2S-U\u003cbr\u003eIndustrial L2\/L4 16-Port 10\/100\/1000T + 2-Port 100\/1000X SFP Managed Switch with USB Console (-40~75 degrees C)\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAccessories\u003c\/strong\u003e\u003cbr\u003ePWR-40-24\u003cbr\u003e40W 24V DC Single Output Industrial DIN-rail Power Supply (-20 ~ 70 degrees C)\u003cbr\u003ePWR-60-24\u003cbr\u003e60W 24V DC Single Output Industrial DIN-rail Power Supply (-20 ~ 70 degrees C)\u003cbr\u003ePWR-75-24\u003cbr\u003e75W 24V DC Single Output Industrial DIN-rail Power Supply (-20 ~ 70 degrees C)\u003c\/p\u003e","brand":"Planet","offers":[{"title":"Default Title","offer_id":48892941598976,"sku":"IGS-4215-16T2S-U","price":683.9,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0388\/5331\/2557\/files\/box_IGS-4215-16T2S_d88c4087-bdd9-4406-bbd3-7f1bf65b943d.jpg?v=1782490930","url":"https:\/\/alotechparts.com\/pt-mx\/products\/planet-igs-4215-16t2s-u-ip30-industrial-l2l4-16-port-101001000t-2-port-1001000","provider":"Alo Tech Solutions","version":"1.0","type":"link"}