{"product_id":"planet-wgs-6325-8up2x-ip30-industrial-l3-4-port-25g-8023bt-poe-4-port-101001","title":"Planet WGS-6325-8UP2X IP30 Industrial L3 4-Port 2.5G 802.3bt PoE + 4-Port 10\/100\/1","description":"\u003cp\u003e\u003cstrong\u003eWall-mounted PoE++ Managed Switch with Advanced L3 Switching and Security\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003ePLANET WGS-6325-8UP2X is an Industrial Wall-mount PoE++ Managed Switch featuring PLANET intelligent PoE functions to improve the availability of industrial applications. It provides IPv6\/IPv4 dual stack management and offers a versatile mix of ports, including four 10\/100\/1000\/2500BASE-T and four 10\/100\/1000BASE-T ports. What sets it apart is the 95-watt PoE capability on these ports delivers ample power to various PoE applications. For connecting to a wider network infrastructure, this switch features two additional 1G\/2.5G\/10GBASE-X SFP+ ports, ensuring high-speed data transmission and seamless connectivity. With a total power budget of up to 480 watts for different kinds of PoE applications, and featuring fast performance and operating temperature ranging from -40 to 75 degrees C in a compact but rugged IP30 metal housing, the WGS-6325-8UP2X is an ideal solution to meet the demand for the following network applications:\u003c\/p\u003e\n\u003cp\u003e\u003cimg class=\"img-fluid\" height=\"400\" width=\"1000\" alt=\"\" src=\"https:\/\/planet.com.tw\/storage\/products\/49677\/edm_WGS-6325-8UP2X.jpg\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e802.3bt PoE++ – 90~95-watt Power over 4-pair UTP Solution\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eAs the WGS-6325-8UP2X adopts the IEEE 802.bt PoE++ standard, it is capable to source up to 95 watts of power by using all the four pairs of standard Cat5e\/6 Ethernet cabling to deliver power and full-speed data to each remote PoE compliant powered device (PD). It possesses triple amount of power capability than the conventional 802.3at PoE+ and is an ideal solution to satisfy the growing demand for higher power consuming network PDs, such as:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ePoE PTZ speed dome cameras\u003c\/li\u003e\n\u003cli\u003eAny network device that needs higher PoE power to work normally\u003c\/li\u003e\n\u003cli\u003eThin clients\u003c\/li\u003e\n\u003cli\u003eAIO (all-in-one) touch PCs, point of sale (POS) and information kiosks\u003c\/li\u003e\n\u003cli\u003eRemote digital signage displays\u003c\/li\u003e\n\u003cli\u003ePoE lightings\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eInnovative Wall-mount Installation\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe WGS-6325-8UP2X is specially designed to be installed in a narrow environment, such as wall enclosure or electric box. The compact, flat and wall-mounted design fits easily in any space-limited location. The WGS-6325-8UP2X can be installed by fixed wall mounting, thereby making its usability more flexible.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cimg class=\"img-fluid\" height=\"340\" width=\"358\" alt=\"\" src=\"https:\/\/planet.com.tw\/storage\/products\/49677\/Flat-type_ring.png\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRedundant Ring, Fast Recovery for Critical Network Applications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe WGS-6325-8UP2X supports redundant ring technology and features strong, rapid self-recovery capability to prevent interruptions and external intrusions. It incorporates advanced ITU-T G.8032 ERPS (Ethernet Ring Protection Switching) technology, Spanning Tree Protocol (802.1s MSTP), and dual power input system into customer’s industrial automation network to enhance system reliability and uptime in harsh factory environments. In a certain simple ring network, the recovery time of data link can be as fast as 10ms. \u003c\/p\u003e\n\u003cp\u003e\u003cimg class=\"img-fluid\" height=\"510\" width=\"700\" alt=\"\" src=\"https:\/\/planet.com.tw\/storage\/products\/49677\/Common_PoE-switch-ERPS_Redundant-Connection.png\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBuilt-in Unique PoE Functions for Powered Devices Management\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eAs it is the managed PoE switch for surveillance, wireless and VoIP networks, the WGS-6325-8UP2X features the following special PoE management functions:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ePD alive check\u003c\/li\u003e\n\u003cli\u003eScheduled power recycling \u003c\/li\u003e\n\u003cli\u003ePoE schedule\u003c\/li\u003e\n\u003cli\u003ePoE usage monitoring\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eIntelligent Powered Device Alive Check\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe WGS-6325-8UP2X can be configured to monitor connected PD status in real time via ping action. Once the PD stops working and responding, the WGS-6325-8UP2X will resume the PoE port power and bring the PD back to work. It will greatly enhance the network reliability through the PoE port resetting the PD’s power source and reducing administrator management burden.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cimg class=\"img-fluid\" height=\"336\" width=\"700\" alt=\"\" src=\"https:\/\/planet.com.tw\/storage\/products\/49677\/Common_PD-Alive-Check.png\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eScheduled Power Recycling\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe WGS-6325-8UP2X allows each of the connected PoE IP cameras or PoE wireless access points to reboot at a specific time each week. Therefore, it will reduce the chance of IP camera or AP crash resulting from buffer overflow. \u003c\/p\u003e\n\u003cp\u003e\u003cimg class=\"img-fluid\" height=\"253\" width=\"700\" alt=\"\" src=\"https:\/\/planet.com.tw\/storage\/products\/49677\/Common_PoE-Schedule-for-Energy-Saving.png\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePoE Schedule for Energy Savings\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eUnder the trend of energy savings worldwide and contributing to environmental protection, the WGS-6325-8UP2X can effectively control the power supply besides its capability of giving high watts power. The “PoE schedule” function helps you to enable or disable PoE power feeding for each PoE port during specified time intervals and it is a powerful function to help SMBs or enterprises save power and budget. It also increases security by powering off PDs that should not be in use during non-business hours. \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConvenient and Smart ONVIF Devices with Detection Feature\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003ePLANET has newly developed an awesome feature -- ONVIF Support -- which is specifically designed for co-operating with video IP surveillances. From the WGS-6325-8UP2X’s GUI, you just need one click to search and show all of the ONVIF devices via network application. In addition, you can upload floor images to the switch and can remotely monitor or inspect an assembly line. Moreover, you can get real-time surveillance information and online\/offline status; the PoE reboot can be controlled from the GUI. \u003c\/p\u003e\n\u003cp\u003e\u003cimg class=\"img-fluid\" height=\"371\" width=\"700\" alt=\"\" src=\"https:\/\/planet.com.tw\/storage\/products\/49677\/WGS-6325-8UP2X-1.png\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSMTP\/SNMP Trap Event Alert\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe WGS-6325-8UP2X provides event alert function to help to diagnose the abnormal device owing to whether or not there is a break of the network connection, or the rebooting response.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cimg class=\"img-fluid\" height=\"427\" width=\"701\" alt=\"\" src=\"https:\/\/planet.com.tw\/storage\/products\/49677\/Common_SMTP_SNMP-Trap-Event-Alert_2.png\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eLayer 3 IPv4 and IPv6 Software VLAN Routing for Secure and Flexible Management\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eTo help customers stay on top of their businesses, the WGS-6325-8UP2X not only provides ultra high transmission performance and excellent Layer 2 technologies, but also IPv4\/IPv6 software VLAN routing feature which allows to cross over different VLANs and different IP addresses for the purpose of having a highly-secure, flexible management and simpler networking application.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRobust Layer 2 Features\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe WGS-6325-8UP2X can be programmed for advanced switch management functions such as dynamic port link aggregation, Q-in-Q VLAN, private VLAN, Rapid Spanning Tree Protocol, Layer 2 to Layer 4 QoS, bandwidth control and IGMP snooping. The WGS-6325-8UP2X provides 802.1Q tagged VLAN, and the VLAN groups allowed will be maximally up to 2K. Via aggregation of supporting ports, the WGS-6325-8UP2X allows the operation of a high-speed trunk combining multiple ports. It enables a maximum of up to 2 trunk groups with 2 ports per trunk group, and supports fail-over as well. \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNetwork with Cybersecurity Helps Minimize Security Risks\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe WGS-6325-8UP2X comes with enhanced cybersecurity to fend off cyberthreats and cyberattacks. It supports SSHv2 and TLSv1.2 protocols to provide strong protection against advanced threats. Served as a key point to transmit data to customer's critical equipment in a business network, the cybersecurity feature of the WGS-6325-8UP2X protects the switch management and enhances the security of the mission-critical network without any extra deployment cost and effort.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eEfficient Management\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eFor efficient management, the WGS-6325-8UP2X is equipped with Command line, Web and SNMP management interfaces.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eWith the built-in\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eWeb-based\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003emanagement interface, the WGS-6325-8UP2X offers an easy-to-use, platform-independent management and configuration facility.\u003c\/li\u003e\n\u003cli\u003eFor\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003etext-based\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003emanagement, it can be accessed via Telnet and SSHv2 protocol.\u003c\/li\u003e\n\u003cli\u003eFor standard-based monitor and management software, it offers SNMPv3 connection which encrypts the packet content at each session for secure remote management.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cimg class=\"img-fluid\" height=\"137\" width=\"700\" alt=\"\" src=\"https:\/\/planet.com.tw\/storage\/products\/49677\/Common_Secure-Management.png\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePowerful Security from Layer 2 to Layer 4\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe WGS-6325-8UP2X offers comprehensive Layer 2 to Layer 4\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAccess Control List (ACL)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor enforcing security to the edge. It can be used to restrict network access by denying packets based on source and destination IP address, TCP\/UDP ports or defined typical network applications. Its protection mechanism also comprises\u003cstrong\u003e\u003cspan\u003e \u003c\/span\u003e802.1X Port-based\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eMAC-based\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003euser and device authentication. With the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eprivate VLAN\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efunction, communication between edge ports can be prevented to ensure user privacy.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAdvanced IP Network Protection\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe WGS-6325-8UP2X also provides\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eDHCP Snooping\u003c\/strong\u003e,\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIP Source Guard\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eDynamic ARP Inspection\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efunctions to prevent IP snooping from attack and discard ARP packets with invalid MAC address. The network administrators can now construct highly-secure corporate networks with considerably less time and effort than before.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eModbus TCP provides Flexible Network Connectivity for Factory Automation\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWith the supported\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eModbus TCP\/IP\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eprotocol, the WGS-6325-8UP2X can easily integrate with\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSCADA\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003esystems,\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eHMI\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003esystems and other data acquisition systems in factory floors. It enables administrators to remotely monitor the industrial Ethernet switch’s\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eoperating information\u003c\/strong\u003e,\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eport information\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ecommunication status\u003c\/strong\u003e, thus easily achieving enhanced monitoring and maintenance of the entire factory.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFlexibility and Extension Solution\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe additional two SFP slots built in the WGS-6325-8UP2X support multi-speed,\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1GBASE-SX\/LX, 2.5GBASE-X and 10GBASE-X SFP+\u003c\/strong\u003e (Small Form-factor Pluggable) fiber-optic modules, meaning the administrator now can flexibly choose the suitable SFP transceiver according to not only the transmission distance but also the transmission speed required. The distance can be extended from 550 meters (multi-mode fiber) to 20\/40\/80\/120 kilometers (single-mode fiber or WDM fiber). They are well suited for applications within the enterprise data centers and distributions. \u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cimg class=\"img-fluid\" height=\"396\" width=\"700\" alt=\"\" src=\"https:\/\/planet.com.tw\/storage\/products\/49677\/WGS-6325-8UP2X-2.png\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIntelligent SFP Diagnosis Mechanism\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe WGS-6325-8UP2X supports SFP-\u003cstrong\u003eDDM\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(Digital Diagnostic Monitor) function that greatly helps network administrator to easily monitor real-time parameters of the SFP, such as optical output power, optical input power, temperature, laser bias current, and transceiver supply voltage.\u003c\/p\u003e\n\u003cp\u003e\u003cimg class=\"img-fluid\" height=\"350\" width=\"700\" alt=\"\" src=\"https:\/\/planet.com.tw\/storage\/products\/49677\/Common_Intelligent-SFP_SFP+-Diagnosis-Mechanism.png\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e1588 Time Protocol for Industrial Computing Networks\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe WGS-6325-8UP2X is ideal for telecom and Carrier Ethernet applications, supporting MEF service delivery and timing over packet solutions for IEEE 1588 and synchronous Ethernet.\u003c\/p\u003e\n\u003cp\u003e\u003cimg class=\"img-fluid\" height=\"451\" width=\"700\" alt=\"\" src=\"https:\/\/planet.com.tw\/storage\/products\/49677\/Common_Time-Synchronization-in-Network_2.png\"\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePhysical Port\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e4 10\/100\/1000\/2500BASE-T\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e4 10\/100\/1000BASE-T\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eGigabit Ethernet RJ45 ports with\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIEEE 802.3bt PoE++\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eInjector function\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e2 1G\/2.5G\/10GBASE-X SFP+\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eslots for SFP type auto detection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIndustrial Case and Installation\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eIP30 aluminum case \u003c\/li\u003e\n\u003cli\u003eSupports -40 to 75 degrees C operating temperature \u003c\/li\u003e\n\u003cli\u003eSupports ESD 6KV DC Ethernet protection \u003c\/li\u003e\n\u003cli\u003eDual power input design\n\u003cul\u003e\n\u003cli\u003e48V~54V DC wide power input with reverse polarity protection \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eCompact size with fixed wall-mounted design\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003ePower over Ethernet \u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eComplies with IEEE 802.3bt Power over Ethernet Plus Plus PSE\u003c\/li\u003e\n\u003cli\u003eBackward compatible with 802.3at PoE+ end-span or mid-span PSE\u003c\/li\u003e\n\u003cli\u003eUp to 8 IEEE 802.3af\/802.3at\/802.3bt devices powered\u003c\/li\u003e\n\u003cli\u003eSupports PoE power up to 95 watts for each PoE port\u003c\/li\u003e\n\u003cli\u003eAuto detects powered device (PD)\u003c\/li\u003e\n\u003cli\u003eCircuit protection prevents power interference between ports\u003c\/li\u003e\n\u003cli\u003eRemote power feeding up to 100m\u003c\/li\u003e\n\u003cli\u003ePoE management features\n\u003cul\u003e\n\u003cli\u003eTotal PoE power budget control\u003c\/li\u003e\n\u003cli\u003ePer port PoE function enable\/disable\u003c\/li\u003e\n\u003cli\u003ePoE admin-mode control \u003c\/li\u003e\n\u003cli\u003ePoE port power feeding priority\u003c\/li\u003e\n\u003cli\u003ePer PoE port power limit\u003c\/li\u003e\n\u003cli\u003ePD classification detection\u003c\/li\u003e\n\u003cli\u003eSequence port PoE\u003c\/li\u003e\n\u003cli\u003ePoE extend mode control to support power feeding up to a distance of up to 160 meters\u003c\/li\u003e\n\u003cli\u003eAuto maximum PoE budget control by power input detection \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eIntelligent PoE features\n\u003cul\u003e\n\u003cli\u003ePoE usage threshold control\u003c\/li\u003e\n\u003cli\u003ePD alive check\u003c\/li\u003e\n\u003cli\u003ePoE schedule\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eIndustrial Protocol\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eModbus TCP for real-time monitoring in SCADA system\u003c\/li\u003e\n\u003cli\u003eIEEE 1588v2 PTP (Precision Time Protocol) transparent clock mode\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eLayer 3 IP Routing Features\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eIPv4 dynamic routing protocol supports RIPv2 and OSPFv2. \u003c\/li\u003e\n\u003cli\u003eIPv6 dynamic routing protocol supports OSPFv3.\u003c\/li\u003e\n\u003cli\u003eIPv4\/IPv6 hardware static routing\u003c\/li\u003e\n\u003cli\u003eSupports maximum 32 static routes and route summarization\u003c\/li\u003e\n\u003cli\u003eRouting interface provides per VLAN routing mode\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eLayer 2 Features\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eStorm Control support\n\u003cul\u003e\n\u003cli\u003eBroadcast\/Multicast\/Unicast\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eSupports\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eVLAN\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eIEEE 802.1Q tagged VLAN\u003c\/li\u003e\n\u003cli\u003eProvider Bridging (VLAN Q-in-Q) support (IEEE 802.1ad) \u003c\/li\u003e\n\u003cli\u003ePrivate VLAN Edge (PVE)\u003c\/li\u003e\n\u003cli\u003eProtocol-based VLAN\u003c\/li\u003e\n\u003cli\u003eMAC-based VLAN\u003c\/li\u003e\n\u003cli\u003eVoice VLAN\u003c\/li\u003e\n\u003cli\u003eGVRP (GARP VLAN Registration Protocol)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eSupports\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSpanning Tree Protocol\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eIEEE 802.1D Spanning Tree Protocol (STP)\u003c\/li\u003e\n\u003cli\u003eIEEE 802.1w Rapid Spanning Tree Protocol (RSTP)\u003c\/li\u003e\n\u003cli\u003eIEEE 802.1s Multiple Spanning Tree Protocol (MSTP), spanning tree by VLAN\u003c\/li\u003e\n\u003cli\u003eBPDU Guard\/BPDU Filtering\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eSupports\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eLink Aggregation\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003e802.3ad Link Aggregation Control Protocol (LACP)\u003c\/li\u003e\n\u003cli\u003eCisco ether-channel (static trunk)\u003c\/li\u003e\n\u003cli\u003eMaximum 5 trunk groups with 10 ports per trunk group \u003c\/li\u003e\n\u003cli\u003eUp to 10Gbps bandwidth (duplex mode) \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eProvides port mirror (many-to-1)\u003c\/li\u003e\n\u003cli\u003ePort mirroring to monitor the incoming or outgoing traffic on a particular port \u003c\/li\u003e\n\u003cli\u003eLoop protection to avoid broadcast loops\u003c\/li\u003e\n\u003cli\u003eSupports ERPS (Ethernet Ring Protection Switching)\u003c\/li\u003e\n\u003cli\u003eCompatible with Cisco\u003cstrong\u003e\u003cspan\u003e \u003c\/span\u003eUni-directional link detection\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(UDLD) that monitors a link between two switches and blocks the ports on both ends of the link if the link fails at any point between the two devices\u003c\/li\u003e\n\u003cli\u003eLink Layer Discovery Protocol (LLDP) \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eQuality of Service\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eIngress Shaper and Egress Rate Limit per port bandwidth control\u003c\/li\u003e\n\u003cli\u003e8 priority queues on all switch ports\u003c\/li\u003e\n\u003cli\u003eTraffic classification\n\u003cul\u003e\n\u003cli\u003eIEEE 802.1p CoS\u003c\/li\u003e\n\u003cli\u003eIP TOS\/DSCP\/IP precedence\u003c\/li\u003e\n\u003cli\u003eIP TCP\/UDP port number\u003c\/li\u003e\n\u003cli\u003eTypical network application\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eStrict priority and Weighted Round Robin (WRR) CoS policies\u003c\/li\u003e\n\u003cli\u003eSupports QoS and In\/Out bandwidth control on each port\u003c\/li\u003e\n\u003cli\u003eTraffic-policing on the switch port\u003c\/li\u003e\n\u003cli\u003eDSCP remarking\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eMulticast\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSupports IPv4 IGMP Snooping v1, v2 and v3\u003c\/li\u003e\n\u003cli\u003eSupports IPv6 MLD Snooping v1 and v2\u003c\/li\u003e\n\u003cli\u003eQuerier mode support\u003c\/li\u003e\n\u003cli\u003eIPv4 IGMP Snooping port filtering\u003c\/li\u003e\n\u003cli\u003eIPv6 MLD Snooping port filtering\u003c\/li\u003e\n\u003cli\u003eMVR (Multicast VLAN Registration)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eSecurity\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eAuthentication\n\u003cul\u003e\n\u003cli\u003eIEEE 802.1x Port-based \/ MAC-based network access authentication\u003c\/li\u003e\n\u003cli\u003eBuilt-in RADIUS client to cooperate with the RADIUS servers\u003c\/li\u003e\n\u003cli\u003eTACACS+ login users access authentication\u003c\/li\u003e\n\u003cli\u003eRADIUS\/TACACS+ users access authentication\u003c\/li\u003e\n\u003cli\u003eGuest VLAN assigns clients to a restricted VLAN with limited services\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eAccess Control List\n\u003cul\u003e\n\u003cli\u003eIP-based Access Control List (ACL)\u003c\/li\u003e\n\u003cli\u003eMAC-based Access Control List\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eSource MAC \/ IP address binding\u003c\/li\u003e\n\u003cli\u003eDHCP Snooping to filter un-trusted DHCP messages\u003c\/li\u003e\n\u003cli\u003eDynamic ARP Inspection discards ARP packets with invalid MAC address to IP address binding\u003c\/li\u003e\n\u003cli\u003eIP Source Guard prevents IP spoofing attacks\u003c\/li\u003e\n\u003cli\u003eAuto DoS rule to defend DoS attack\u003c\/li\u003e\n\u003cli\u003eIP address access management to prevent unauthorized intruder\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eManagement\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eIPv4 and IPv6 dual stack management\u003c\/li\u003e\n\u003cli\u003eSwitch Management Interfaces\n\u003cul\u003e\n\u003cli\u003eTelnet Command Line Interface \u003c\/li\u003e\n\u003cli\u003eWeb switch management\u003c\/li\u003e\n\u003cli\u003eSNMP v1, v2c, and v3 switch management\u003c\/li\u003e\n\u003cli\u003eSSHv2 and TLSv1.2 secure access\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eSNMP Management\n\u003cul\u003e\n\u003cli\u003eFour RMON groups (history, statistics, alarms, and events) \u003c\/li\u003e\n\u003cli\u003eSNMP trap for interface Link Up and Link Down notification\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIPv6\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIP address\/NTP\/DNS management\u003c\/li\u003e\n\u003cli\u003eBuilt-in Trivial File Transfer Protocol (TFTP) client\u003c\/li\u003e\n\u003cli\u003eBOOTP and DHCP for IP address assignment\u003c\/li\u003e\n\u003cli\u003eSystem Maintenance\n\u003cul\u003e\n\u003cli\u003eFirmware upload\/download via HTTP\/TFTP\u003c\/li\u003e\n\u003cli\u003eReset button for system reboot or reset to factory default\u003c\/li\u003e\n\u003cli\u003eDual Images\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eDHCP Relay and DHCP Option 82\u003c\/li\u003e\n\u003cli\u003eDHCP Server \u003c\/li\u003e\n\u003cli\u003eUser Privilege levels control\u003c\/li\u003e\n\u003cli\u003eNetwork Time Protocol (NTP)\u003c\/li\u003e\n\u003cli\u003eNetwork Diagnositc\n\u003cul\u003e\n\u003cli\u003eICMPv6\/ICMPv4 Remote Ping\u003c\/li\u003e\n\u003cli\u003eCable diagnostic technology provides the mechanism to detect and report potential cabling issues\u003c\/li\u003e\n\u003cli\u003eSFP-DDM (Digital Diagnostic Monitor)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eSMTP, Syslog and SNMP trap remote alarm\u003c\/li\u003e\n\u003cli\u003eSystem Log\u003c\/li\u003e\n\u003cli\u003ePLANET UNI-NMS (Universal Network Management) and Smart Discovery Utility for deployment management\u003c\/li\u003e\n\u003cli\u003eProvides ONVIF for co-operating with PLANET video IP surveillances\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ctable class=\"table table-sm table-bordered-bone table-striped-blue table-header-theme-blue table-header-no-border\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\"\u003eHardware Specifications\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eCopper Ports\u003c\/td\u003e\n\u003ctd\u003e4 10\/100\/1000\/2500BASE-T RJ45 auto-MDI\/MDI-X ports (Ports 1 to 4)\u003cbr\u003e4 10\/100\/1000BASE-T RJ45 auto-MDI\/MDI-X ports (Ports 5 to 8)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eSFP+ Slots\u003c\/td\u003e\n\u003ctd\u003e2 1G\/2.5G\/10GBASE-X SFP+ interfaces\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003ePoE Injector Port\u003c\/td\u003e\n\u003ctd\u003e8 ports with 802.3bt PoE++ injector function (Ports1 to 8)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eRAM\u003c\/td\u003e\n\u003ctd\u003e512MBytes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eFlash Memory\u003c\/td\u003e\n\u003ctd\u003e64MBytes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eReset Button\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 5 sec: System reboot\u003cbr\u003e\u0026gt; 5 sec: Factory Default\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eConnector\u003c\/td\u003e\n\u003ctd\u003e4-pin terminal block for power input\u003cbr\u003e　Pin 1\/2 for Power 1 (Pin 1: V+ \/ Pin 2: V-)\u003cbr\u003e　Pin 3\/4 for Power 2 (Pin 3: V+ \/ Pin 4: V-)\u003cbr\u003e2-pin terminal block for event alarm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eAlarm\u003c\/td\u003e\n\u003ctd\u003eOne relay output for power failure. Alarm Relay current carry ability: 1A @ 24V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eEnclosure\u003c\/td\u003e\n\u003ctd\u003eIP30 aluminum case\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eInstallation\u003c\/td\u003e\n\u003ctd\u003eWall-mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eDimensions (W x D x H)\u003c\/td\u003e\n\u003ctd\u003e245 x 36 x 140 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1,230g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003ePower Requirements\u003c\/td\u003e\n\u003ctd\u003e48~54V DC\u003cbr\u003e(\u0026gt;52V DC for PoE++ and PoE+ output recommended)\u003cbr\u003eDual power input is required for maximum power loading\u003cbr\u003eMaximum current 11A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e\n\u003cb\u003eSystem on:\u003c\/b\u003e\u003cbr\u003e　Max. 13.22 watts\/45.08 BTU @54V DC input (240-watt PoE Budget)\u003cbr\u003e　Max. 16.97 watts\/57.87 BTU @54V DC input (480-watt PoE Budget)\u003cbr\u003e\u003cb\u003eFull loading with 802.3bt PoE++ function:\u003c\/b\u003e\u003cbr\u003e　Max. 256.2 watts\/874.19 BTU @Single 54V DC input (240-watt PoE Budget)\u003cbr\u003e　Max. 496.9 watts\/1694.43 BTU @Dual 54V DC input (480-watt PoE Budget)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eESD Protection\u003c\/td\u003e\n\u003ctd\u003e6KV DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eLED Indicator\u003c\/td\u003e\n\u003ctd\u003e\n\u003cb\u003eSystem:\u003c\/b\u003e\u003cbr\u003e　PWR 1(\u003cspan style=\"color: green;\"\u003e\u003cb\u003eGreen\u003c\/b\u003e\u003c\/span\u003e)\u003cbr\u003e　PWR 2 (\u003cspan style=\"color: green;\"\u003e\u003cb\u003eGreen\u003c\/b\u003e\u003c\/span\u003e)\u003cbr\u003e　Ring (\u003cspan style=\"color: green;\"\u003e\u003cb\u003eGreen\u003c\/b\u003e\u003c\/span\u003e)\u003cbr\u003e　Ring Owner (\u003cspan style=\"color: green;\"\u003e\u003cb\u003eGreen\u003c\/b\u003e\u003c\/span\u003e)\u003cbr\u003e\u003cb\u003ePer 10\/100\/1000\/2500T RJ45 PoE++ Ports:\u003c\/b\u003e\u003cbr\u003e　1000\/2500 LNK\/ACT (\u003cspan style=\"color: green;\"\u003e\u003cb\u003eGreen\u003c\/b\u003e\u003c\/span\u003e)\u003cbr\u003e　10\/100 LNK\/ACT (\u003cspan style=\"color: orange;\"\u003e\u003cb\u003eAmber\u003c\/b\u003e\u003c\/span\u003e)\u003cbr\u003e　802.3bt PoE-in-Use (\u003cspan style=\"color: green;\"\u003e\u003cb\u003eGreen\u003c\/b\u003e\u003c\/span\u003e)\u003cbr\u003e　802.3af\/at PoE-in-Use (\u003cspan style=\"color: orange;\"\u003e\u003cb\u003eAmber\u003c\/b\u003e\u003c\/span\u003e)\u003cbr\u003e\u003cb\u003ePer SFP+ Interface:\u003c\/b\u003e\u003cbr\u003e　1G\/2.5G LNK\/ACT (\u003cspan style=\"color: green;\"\u003e\u003cb\u003eGreen\u003c\/b\u003e\u003c\/span\u003e)\u003cbr\u003e　10G LNK\/ACT (\u003cspan style=\"color: orange;\"\u003e\u003cb\u003eAmber\u003c\/b\u003e\u003c\/span\u003e)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\"\u003eSwitching Specifications\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eSwitch Architecture\u003c\/td\u003e\n\u003ctd\u003eStore-and-Forward\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eSwitch Fabric\u003c\/td\u003e\n\u003ctd\u003e68Gbps\/non-blocking\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eThroughput (packet per second)\u003c\/td\u003e\n\u003ctd\u003e50.592Mbps@ 64 bytes packet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eAddress Table\u003c\/td\u003e\n\u003ctd\u003e8K entries, automatic source address learning and aging\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eShared Data Buffer\u003c\/td\u003e\n\u003ctd\u003e4.1Mbits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eFlow Control\u003c\/td\u003e\n\u003ctd\u003eIEEE 802.3x pause frame for full duplex\u003cbr\u003eBack pressure for half duplex\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eJumbo Frame\u003c\/td\u003e\n\u003ctd\u003e10Kbytes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eReset Button\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 5 sec: System reboot\u003cbr\u003e\u0026gt; 5 sec: Factory default\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\"\u003ePower Over Ethernet\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003ePoE Standard\u003c\/td\u003e\n\u003ctd\u003eIEEE 802.3bt PoE++ Type-4 PSE\u003cbr\u003eBackward compatible with 802.3at PoE+ PSE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003ePoE Power Supply Type\u003c\/td\u003e\n\u003ctd\u003e802.3bt\u003cbr\u003eEnd-span\u003cbr\u003eMid-span\u003cbr\u003eForce\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003ePoE Power Output\u003c\/td\u003e\n\u003ctd\u003ePer port 54V DC\u003cbr\u003e　802.3bt Type-4 mode: maximum 95 watts\u003cbr\u003e　End-span mode: maximum 36 watts\u003cbr\u003e　Mid-span mode: maximum 36 watts\u003cbr\u003e　Force mode: maximum 95 watts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003ePower Pin Assignment\u003c\/td\u003e\n\u003ctd\u003e802.3bt: 1\/2(-), 3\/6(+),4\/5(+), 7\/8(-)\u003cbr\u003eEnd-span: 1\/2(-), 3\/6(+)\u003cbr\u003eMid-span: 4\/5(+), 7\/8(-)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003ePoE Power Budget\u003c\/td\u003e\n\u003ctd\u003eSingle power input: 240W maximum (depending on power input)\u003cbr\u003eDual power input: 480W maximum (depending on power input)\u003cbr\u003e※Dual power input must be the same as DC voltage, like dual 54V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eMax. Number of Class 3 PDs\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eMax. Number of Class 4 PDs\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eMax. Number of Class 8 PDs\u003c\/td\u003e\n\u003ctd\u003e5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\"\u003ePoE Management Functions\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eActive PoE Device Detection\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003ePoE Power Recycling\u003c\/td\u003e\n\u003ctd\u003eYes, daily or predefined schedule\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003ePoE Schedule\u003c\/td\u003e\n\u003ctd\u003e4 schedule profiles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003ePoE Extend Mode\u003c\/td\u003e\n\u003ctd\u003eYes, max. 160 meters\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003ePoE System Management\u003c\/td\u003e\n\u003ctd\u003eSystem PoE Admin control\u003cbr\u003eTotal PoE power budget control\u003cbr\u003eAuto power input and PoE budget control\u003cbr\u003ePoE Legacy mode\u003cbr\u003eOver-temperature threshold alarm\u003cbr\u003ePoE usage threshold alarm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003ePoE Port Management\u003c\/td\u003e\n\u003ctd\u003ePort Enable\/Disable\/Schedule\u003cbr\u003ePoE mode control\u003cbr\u003e　802.3bt\u003cbr\u003e　802.3at End-span\u003cbr\u003e　802.3at Mid-span\u003cbr\u003e　Force mode\u003cbr\u003ePort Priority\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\"\u003eLayer 3 Functions\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eIP Interfaces\u003c\/td\u003e\n\u003ctd\u003eMax. 32 VLAN interfaces\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eRouting Table\u003c\/td\u003e\n\u003ctd\u003eMax. 32 static routing entries\u003cbr\u003eMax. 1K dynamic routing entries\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eRouting Protocols\u003c\/td\u003e\n\u003ctd\u003eIPv4 RIPv2\u003cbr\u003eIPv4 OSPFv2 dynamic routing\u003cbr\u003eIPv6 OSPFv3 dynamic routing\u003cbr\u003eIPv4 hardware static routing\u003cbr\u003eIPv6 hardware static routing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\"\u003eLayer 2 Function\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003ePort Configuration\u003c\/td\u003e\n\u003ctd\u003ePort disable\/enable\u003cbr\u003eAuto-negotiation 10\/100\/1000\/2500\/10000Mbps full and half duplex mode selection\u003cbr\u003eFlow control disable\/enable\u003cbr\u003ePort link capability control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003ePort Status\u003c\/td\u003e\n\u003ctd\u003eDisplay each port’s speed duplex mode, link status, flow control status,\u003cbr\u003eauto negotiation status, trunk status\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003ePort Mirroring\u003c\/td\u003e\n\u003ctd\u003eTX\/RX\/both\u003cbr\u003eMany-to-1 monitor\u003cbr\u003eRMirror – Remote Switched Port Analyzer (Cisco RSPAN)\u003cbr\u003eSupports up to 5 sessions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eVLAN\u003c\/td\u003e\n\u003ctd\u003eIEEE 802.1Q tag-based VLAN\u003cbr\u003eIEEE 802.1ad Q-in-Q tunneling\u003cbr\u003ePrivate VLAN Edge (PVE)\u003cbr\u003eMAC-based VLAN\u003cbr\u003eProtocol-based VLAN\u003cbr\u003eVoice VLAN\u003cbr\u003eMVR (Multicast VLAN Registration)\u003cbr\u003eGVRP\u003cbr\u003eUp to 4K VLAN groups, out of 4096 VLAN IDs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eLink Aggregation\u003c\/td\u003e\n\u003ctd\u003eIEEE 802.3ad LACP\/static trunk\u003cbr\u003eSupports\u003cbr\u003e　Static Port Trucking, (10 ports\/5 groups max.)\u003cbr\u003e　Dynamic LACP-(10 ports\/5 groups max.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eSpanning Tree Protocol\u003c\/td\u003e\n\u003ctd\u003eIEEE 802.1D Spanning Tree Protocol\u003cbr\u003eIEEE 802.1w Rapid Spanning Tree Protocol\u003cbr\u003eIEEE 802.1s Multiple Spanning Tree Protocol\u003cbr\u003eBPDU Guard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eIGMP Snooping\u003c\/td\u003e\n\u003ctd\u003eIpv4 IGMP (v1\/v2 \/v3) Snooping\u003cbr\u003eIpv4 IGMP Querier mode support\u003cbr\u003eIPv4 IGMP Snooping port filtering\u003cbr\u003eUp to 255 multicast Groups\u003cbr\u003eMulticast VLAN Registration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eMLD Snooping\u003c\/td\u003e\n\u003ctd\u003eIpv6 MLD (v1\/v2) Snooping\u003cbr\u003eIpv6 MLD Querier mode support\u003cbr\u003eUp to 255 multicast Groups\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eBandwidth Control\u003c\/td\u003e\n\u003ctd\u003ePer port bandwidth control\u003cbr\u003eIngress: 500Kb~1000Mbps\u003cbr\u003eEgress: 500Kb~1000Mbps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eRING\u003c\/td\u003e\n\u003ctd\u003eSupport ERPS, complies with ITU-T G.8032v1 and v2\u003cbr\u003eRecovery time \u0026lt; 10ms @ 3 nodes\u003cbr\u003eRecovery time \u0026lt; 50ms @ 16 nodes\u003cbr\u003eSupports Major ring and sub-ring\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eSynchronization\u003c\/td\u003e\n\u003ctd\u003eIEEE 1588v2 PTP(Precision Time Protocol)\u003cbr\u003e　Peer-to-peer transparent clock\u003cbr\u003e　End-to-end transparent clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eQoS\u003c\/td\u003e\n\u003ctd\u003eTraffic classification based, strict priority and WRR\u003cbr\u003e8-level priority for switching\u003cbr\u003e　Port number\u003cbr\u003e　802.1p priority\u003cbr\u003e　802.1Q VLAN tag\u003cbr\u003e　DSCP\/TOS field in IP packet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\"\u003eSecurity Functions\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eAccess Control List\u003c\/td\u003e\n\u003ctd\u003eIP-based ACL\/MAC-based ACL\u003cbr\u003eACL based on:\u003cbr\u003e　MAC Address\u003cbr\u003e　IP Address\u003cbr\u003e　Ethertype\u003cbr\u003e　Protocol Type\u003cbr\u003e　VLAN ID\u003cbr\u003e　DSCP\u003cbr\u003e　802.1p Priority\u003cbr\u003eUp to 512 entries\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eSecurity\u003c\/td\u003e\n\u003ctd\u003ePort security\u003cbr\u003eIP source guard, up to 512 entries\u003cbr\u003eDynamic ARP inspection, up to 1K entries\u003cbr\u003eCommand line authority control based on user level\u003cbr\u003eStatic MAC address, up to 64 entries\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eAAA\u003c\/td\u003e\n\u003ctd\u003eRADIUS client\u003cbr\u003eTACACS+ client\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eNetwork Access Control\u003c\/td\u003e\n\u003ctd\u003eIEEE 802.1x port-based network access control\u003cbr\u003eMAC-based authentication\u003cbr\u003eLocal\/RADIUS authentication\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\"\u003eManagement Functions\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eBasic Management Interfaces\u003c\/td\u003e\n\u003ctd\u003eTelnet; Web browser; SNMP v1, v2c\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eSecure Management Interfaces\u003c\/td\u003e\n\u003ctd\u003eSSHv2, TLS v1.2, SNMPv3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eSystem Management\u003c\/td\u003e\n\u003ctd\u003eFirmware upgrade by HTTP protocol through Ethernet network\u003cbr\u003eConfiguration upload\/download through HTTP\u003cbr\u003eLLDP protocol\u003cbr\u003eNTP\u003cbr\u003ePLANET Smart Discovery Utility\u003cbr\u003ePLANET CloudViewerPro app\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eEvent Management\u003c\/td\u003e\n\u003ctd\u003eRemote Syslog\u003cbr\u003eSystem log\u003cbr\u003eSMTP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eONVIF\u003c\/td\u003e\n\u003ctd\u003eONVIF device discovery\u003cbr\u003eONVIF device monitoring\u003cbr\u003eFloor Map\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eSNMP MIBs\u003c\/td\u003e\n\u003ctd\u003eRFC 1213 MIB-II\u003cbr\u003eIF-MIB\u003cbr\u003eRFC 1493 Bridge MIB\u003cbr\u003eRFC 1643 Ethernet MIB\u003cbr\u003eRFC 2863 Interface MIB\u003cbr\u003eRFC 2665 Ether-Like MIB\u003cbr\u003eRFC 2819 RMON MIB (Groups 1, 2, 3 and 9)\u003cbr\u003eRFC 2737 Entity MIB\u003cbr\u003eRFC 2618 RADIUS Client MIB\u003cbr\u003eRFC 2933 IGMP-STD-MIB\u003cbr\u003eRFC 3411 SNMP-Frameworks-MIB\u003cbr\u003eIEEE 802.1X PAE\u003cbr\u003eLLDP\u003cbr\u003eMAU-MIB\u003cbr\u003ePower over Ethernet MIB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\"\u003eStandards Conformance\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eRegulatory Compliance\u003c\/td\u003e\n\u003ctd\u003eFCC Part 15 Class A, CE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eStability Testing\u003c\/td\u003e\n\u003ctd\u003eIEC60068-2-32 (free fall)\u003cbr\u003eIEC60068-2-27 (shock)\u003cbr\u003eIEC60068-2-6 (vibration)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eStandards Compliance\u003c\/td\u003e\n\u003ctd\u003eIEEE 802.3 10BASE-T\u003cbr\u003eIEEE 802.3u 100BASE-TX\/100BASE-FX\u003cbr\u003eIEEE 802.3z Gigabit SX\/LX\u003cbr\u003eIEEE 802.3ab Gigabit 1000T\u003cbr\u003eIEEE 802.3bz 2.5GBASE-T\u003cbr\u003eIEEE 802.3ae 10Gb\/s Ethernet\u003cbr\u003eIEEE 802.3x flow control and back pressure\u003cbr\u003eIEEE 802.3ad port trunk with LACP\u003cbr\u003eIEEE 802.1D Spanning Tree Protocol\u003cbr\u003eIEEE 802.1w Rapid Spanning Tree Protocol\u003cbr\u003eIEEE 802.1s Multiple Spanning Tree Protocol\u003cbr\u003eIEEE 802.1p Class of Service\u003cbr\u003eIEEE 802.1Q VLAN tagging\u003cbr\u003eIEEE 802.1ad Q-in-Q VLAN stacking\u003cbr\u003eIEEE 802.1X Port Authentication Network Control\u003cbr\u003eIEEE 802.1ab LLDP\u003cbr\u003eIEEE 802.3af Power over Ethernet\u003cbr\u003eIEEE 802.3at Power over Ethernet Plus\u003cbr\u003eIEEE 802.3bt Power over Ethernet Plus Plus\u003cbr\u003eIEEE 802.3ah OAM\u003cbr\u003eIEEE 802.1ag Connectivity Fault Management (CFM)\u003cbr\u003eIEEE 802.3az Energy Efficient Ethernet (EEE)\u003cbr\u003eIEEE 1588 PTPv2\u003cbr\u003eRFC 768 UDP\u003cbr\u003eRFC 793 TFTP\u003cbr\u003eRFC 791 IP\u003cbr\u003eRFC 792 ICMP\u003cbr\u003eRFC 2068 HTTP\u003cbr\u003eRFC 1112 IGMP v1\u003cbr\u003eRFC 2236 IGMP v2\u003cbr\u003eRFC 3376 IGMP v3\u003cbr\u003eRFC 2710 MLD version 1\u003cbr\u003eRFC 3810 MLD version 2\u003cbr\u003eITU-T G.8032 Ethernet Ring Protection Switching\u003cbr\u003eITU-T Y.1731 Performance Monitoring\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\"\u003eEnvironment\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eOperating\u003c\/td\u003e\n\u003ctd\u003eTemperature: -40 ~ 75 degrees C\u003cbr\u003eRelative Humidity: 5 ~ 95% (non-condensing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eStorage\u003c\/td\u003e\n\u003ctd\u003eTemperature: -40 ~ 85 degrees C\u003cbr\u003eRelative Humidity: 5 ~ 95% (non-condensing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Planet","offers":[{"title":"Default Title","offer_id":48892930949376,"sku":"WGS-6325-8UP2X","price":1188.88,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0388\/5331\/2557\/files\/box_WGS-6325-8UP2X.jpg?v=1782490898","url":"https:\/\/alotechparts.com\/pt-br\/products\/planet-wgs-6325-8up2x-ip30-industrial-l3-4-port-25g-8023bt-poe-4-port-101001","provider":"Alo Tech Solutions","version":"1.0","type":"link"}