{"product_id":"planet-gs-4210-8up2s-ipv6ipv4-8-port-101001000t-8023bt-95w-poe-2-port-100","title":"Planet GS-4210-8UP2S IPv6\/IPv4, 8-Port 10\/100\/1000T 802.3bt 95W PoE + 2-Port 100\/","description":"\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eIEEE 802.3bt PoE++ Managed Switch with Advanced L2\/L4 Switching and Security\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003ePLANET GS-4210-8UP2S is an architecture-optimized 1U Gigabit IEEE 802.3bt PoE++ Managed Switch featuring PLANET intelligent PoE functions to improve the availability of critical business applications. It provides IPv6\/IPv4 dual stack management and built-in L2\/L4 Gigabit switching engine along with 8 10\/100\/1000BASE-T ports featuring 95-watt 802.3bt PoE++ and 2 100\/1000BASE-X SFP ports. With a total power budget of up to 180 watts for different kinds of PoE applications, the GS-4210-8UP2S provides a quick, safe and architecture-optimized  802.3bt PoE++ network solution for small businesses and enterprises.\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cimg class=\"img-fluid\" height=\"400\" width=\"1000\" alt=\"\" src=\"https:\/\/planet.com.tw\/storage\/products\/49676\/edm_GS-4210-8UP2S.jpg\" data-mce-src=\"https:\/\/planet.com.tw\/storage\/products\/49676\/edm_GS-4210-8UP2S.jpg\" data-mce-fragment=\"1\"\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cimg class=\"img-fluid\" height=\"303\" width=\"700\" alt=\"\" src=\"https:\/\/planet.com.tw\/storage\/products\/49676\/GS-4210-8UP2S_Front-Panel-Introduction.png\" data-mce-src=\"https:\/\/planet.com.tw\/storage\/products\/49676\/GS-4210-8UP2S_Front-Panel-Introduction.png\" data-mce-fragment=\"1\"\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eCybersecurity Network Solution to Minimize Security Risks\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003eThe cybersecurity feature included to protect the switch management in a mission-critical network virtually needs no effort and cost to install. Both SSHv2 and TLSv1.2 protocols are utilized to provide strong protection against advanced threats. The network administrator can now construct highly-secure corporate networks with considerably less time and effort than before.\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cimg class=\"img-fluid\" height=\"281\" width=\"700\" alt=\"\" src=\"https:\/\/planet.com.tw\/storage\/products\/49676\/GS-4210-8UP2S-1.png\" data-mce-src=\"https:\/\/planet.com.tw\/storage\/products\/49676\/GS-4210-8UP2S-1.png\" data-mce-fragment=\"1\"\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eRedundant Ring, Fast Recovery for Critical Network Applications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003eThe GS-4210-8UP2S supports redundant ring technology and features strong, rapid self-recovery capability to prevent interruptions and external intrusions. It incorporates advanced\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003cstrong data-mce-fragment=\"1\"\u003eITU-T G.8032 ERPS (Ethernet Ring Protection Switching)\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003etechnology, Spanning Tree Protocol (802.1s MSTP) into customer’s network to enhance system reliability and uptime in various environments.\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cimg class=\"img-fluid\" height=\"547\" width=\"700\" src=\"https:\/\/planet.com.tw\/storage\/products\/49676\/Common_PoE-switch-ERPS_Redundant-Connection1.png\" data-mce-src=\"https:\/\/planet.com.tw\/storage\/products\/49676\/Common_PoE-switch-ERPS_Redundant-Connection1.png\" data-mce-fragment=\"1\"\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eIEEE 802.3bt PoE++ Solutions\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003eThe GS-4210-8UP2S supports the 802.3bt standard, supplying up to 95 watts per 802.3bt port for increased requirements of devices. It can offer more PoE applications, such as:\u003c\/p\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003ePoE PTZ speed dome cameras\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eAny network device that needs higher PoE power to work normally\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eThin-client\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eAIO (All-in-One) touch PC\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eRemote digital signage display\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cimg class=\"img-fluid\" height=\"437\" width=\"700\" alt=\"\" src=\"https:\/\/planet.com.tw\/storage\/products\/49676\/POE-171A-95-2.png\" data-mce-src=\"https:\/\/planet.com.tw\/storage\/products\/49676\/POE-171A-95-2.png\" data-mce-fragment=\"1\"\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eBuilt-in Unique PoE Functions for Powered Devices Management\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003eBeing the managed PoE switches for surveillance, wireless and VoIP networks, the GS-4210-8UP2S features the following special PoE management functions:\u003c\/p\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003ePD alive check\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eScheduled power recycling \u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003ePoE schedule\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003ePoE usage monitoring\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003ePoE extension\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eIntelligent Powered Device Alive Check\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003eThe GS-4210-8UP2S can be configured to monitor connected PD (Powered Device) status in real time via ping action. Once the PD stops working and responding, the GS-4210-8UP2S will resume the PoE port power and bring the PD back to work. It will greatly enhance the network reliability through the PoE port resetting the PD’s power source and reducing administrator management burden.\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cimg class=\"img-fluid\" height=\"336\" width=\"700\" alt=\"\" src=\"https:\/\/planet.com.tw\/storage\/products\/49676\/Common_PD-Alive-Check.png\" data-mce-src=\"https:\/\/planet.com.tw\/storage\/products\/49676\/Common_PD-Alive-Check.png\" data-mce-fragment=\"1\"\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eScheduled Power Recycling\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003eThe GS-4210-8UP2S allows each of the connected PoE IP cameras or PoE wireless access points to reboot at a specified time each week. Therefore, it will reduce the chance of IP camera or AP crash resulting from buffer overflow. \u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cimg class=\"img-fluid\" height=\"337\" width=\"700\" alt=\"\" src=\"https:\/\/planet.com.tw\/storage\/products\/49676\/Common_Scheduled-Power-Recycling.png\" data-mce-src=\"https:\/\/planet.com.tw\/storage\/products\/49676\/Common_Scheduled-Power-Recycling.png\" data-mce-fragment=\"1\"\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003ePoE Schedule for Energy Savings\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003eUnder the trend of energy savings worldwide and contributing to environmental protection, the GS-4210-8UP2S can effectively control the power supply besides its capability of giving high watts power. The “PoE schedule” function helps you to enable or disable PoE power feeding for each PoE port during specified time intervals and it is a powerful function to help SMBs or Enterprises save power and money. It also increases security by powering off PDs that should not be in use during non-business hours.\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cimg class=\"img-fluid\" height=\"253\" width=\"700\" alt=\"\" src=\"https:\/\/planet.com.tw\/storage\/products\/49676\/Common_PoE-Schedule-for-Energy-Saving.png\" data-mce-src=\"https:\/\/planet.com.tw\/storage\/products\/49676\/Common_PoE-Schedule-for-Energy-Saving.png\" data-mce-fragment=\"1\"\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003ePoE Usage Monitoring\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003eVia the power usage chart in the web management interface, the GS-4210-8UP2S enables the administrator to monitor the status of the power usage of the connected PDs in real time. Thus, it greatly enhances the management efficiency of the facilities.\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003ePoE+ Power and Ethernet Data Transmission Distance Extension\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003eIn the “\u003cstrong data-mce-fragment=\"1\"\u003eExtend\u003c\/strong\u003e” operation mode, the GS-4210-8UP2S operates on a per-port basis at 10Mbps duplex operation but can support 50-watt PoE power output correspondingly over a distance of up to 250 meters overcoming the 100m limit on Ethernet UTP cable. With this brand-new feature, the GS-4210-8UP2S provides an additional solution for 802.3at\/bt PoE distance extension, thus saving the cost of Ethernet cable installation. \u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cimg class=\"img-fluid\" height=\"242\" width=\"700\" alt=\"\" src=\"https:\/\/planet.com.tw\/storage\/products\/49676\/Common_PoE-switch_Extend-Mode.png\" data-mce-src=\"https:\/\/planet.com.tw\/storage\/products\/49676\/Common_PoE-switch_Extend-Mode.png\" data-mce-fragment=\"1\"\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eIPv6\/IPv4 Dual Stack Management\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003eSupporting both IPv6 and IPv4 protocols, the GS-4210-8UP2S helps the SMBs to step in the IPv6 era with the lowest investment as its network facilities need not be replaced or overhauled if the IPv6 FTTx edge network is set up. \u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cimg class=\"img-fluid\" height=\"388\" width=\"701\" alt=\"\" src=\"https:\/\/planet.com.tw\/storage\/products\/49676\/Common_IPv6_IPv4-Dual-Stack-Management.png\" data-mce-src=\"https:\/\/planet.com.tw\/storage\/products\/49676\/Common_IPv6_IPv4-Dual-Stack-Management.png\" data-mce-fragment=\"1\"\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eRobust Layer 2 Features\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003eThe GS-4210-8UP2S can be programmed for advanced switch management functions such as dynamic port link aggregation, 802.1Q VLAN and Q-in-Q VLAN, Multiple Spanning Tree Protocol (MSTP), loop and BPDU guard, IGMP snooping, and MLD snooping. Via the link aggregation, the GS-4210-8UP2S allows the operation of a high-speed trunk to combine with multiple ports, and supports fail-over as well.  Also, the Link Layer Discovery Protocol (LLDP) is the Layer 2 protocol included to help discover basic information about neighboring devices on the local broadcast domain.\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cimg class=\"img-fluid\" height=\"217\" width=\"700\" alt=\"\" src=\"https:\/\/planet.com.tw\/storage\/products\/49676\/Common_Robust-Layer-2-Features1.png\" data-mce-src=\"https:\/\/planet.com.tw\/storage\/products\/49676\/Common_Robust-Layer-2-Features1.png\" data-mce-fragment=\"1\"\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eEfficient Traffic Control\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003eThe GS-4210-8UP2S is loaded with robust QoS features and powerful traffic management to enhance services to business-class data, voice and video solutions. The functionality includes broadcast\/multicast\u003cstrong data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003estorm control\u003c\/strong\u003e, per port\u003cstrong data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003ebandwidth control\u003c\/strong\u003e, IP DSCP QoS priority and remarking. It guarantees the best performance for VoIP and video stream transmission, and empowers the enterprises to take full advantage of the limited network resources.\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003ePowerful Security\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003eThe GS-4210-8UP2S offers comprehensive Layer 2 to Layer 4 Access Control List (ACL) for enforcing security to the edge. It can be used to restrict network access by denying packets based on source and destination IP address, TCP\/UDP ports or defined typical network applications. Its protection mechanism also comprises 802.1x Port-based user authentication. With the private VLAN function, communication between edge ports can be prevented to ensure user privacy.\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eAdvanced IP Network Protection\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003eThe GS-4210-8UP2S also provides\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003cstrong data-mce-fragment=\"1\"\u003eDHCP Snooping\u003c\/strong\u003e,\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003cstrong data-mce-fragment=\"1\"\u003eIP Source Guard\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eand\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003cstrong data-mce-fragment=\"1\"\u003eDynamic ARP Inspection\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003efunctions to prevent IP snooping from attack and discard ARP packets with invalid MAC address. The network administrator can now build highly-secure corporate networks with considerably less time and effort than before.\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eEfficient Management \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003eFor efficient management, the GS-4210-8UP2S is equipped with Command line, Web and SNMP management interfaces.\u003c\/p\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003eWith the built-in\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003cstrong data-mce-fragment=\"1\"\u003eWeb-based\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003emanagement interface, the GS-4210-8UP2S offers an easy-to-use, platform-independent management and configuration facility.\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eFor\u003cstrong data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003etext-based\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003emanagement, it can be accessed via Telnet and the console port.\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eBy supporting the standard SNMP protocol, the switch can be managed via any SNMP-based management software.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cimg class=\"img-fluid\" height=\"137\" width=\"700\" alt=\"\" src=\"https:\/\/planet.com.tw\/storage\/products\/49676\/Common_Secure-Management.png\" data-mce-src=\"https:\/\/planet.com.tw\/storage\/products\/49676\/Common_Secure-Management.png\" data-mce-fragment=\"1\"\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eRemote Management Solution\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003ePLANET's Universal Network Management System (UNI-NMS) and CloudViewer\/CloudViewerPro app support IT staff by remotely managing all network devices and monitoring PDs' operational statuses. Thus, they're designed for both the enterprises and industries where deployments of PDs can be as remote as possible, without having to go to the actual location once a bug or faulty condition is found. With the UNI-NMS or CloudViewer\/CloudViewerPro app, all kinds of businesses can now be speedily and efficiently managed from one platform.\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cimg class=\"img-fluid\" height=\"376\" width=\"700\" src=\"https:\/\/planet.com.tw\/storage\/products\/49676\/Common_CloudViewerPro-App.png\" data-mce-src=\"https:\/\/planet.com.tw\/storage\/products\/49676\/Common_CloudViewerPro-App.png\" data-mce-fragment=\"1\"\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eFlexibility and Extension Solution\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003eThe two mini-GBIC slots built in the GS-4210-8UP2S support SFP auto-detection and dual speed as it features\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003cstrong data-mce-fragment=\"1\"\u003e100BASE-FX\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eand\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003cstrong data-mce-fragment=\"1\"\u003e1000BASE-SX\/LX SFP\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e(Small Form-factor Pluggable) fiber transceivers to uplink to backbone switch and monitoring center in long distance. The distance can be extended from 550 meters to 2 kilometers (multi-mode fiber) and up to above 10\/20\/40\/60\/80\/120 kilometers (single-mode fiber or WDM fiber). They are well suited for applications within the enterprise data centers and distributions.\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eIntelligent SFP Diagnosis Mechanism\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003eThe GS-4210-8UP2S supports\u003cstrong data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eSFP-DDM\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e(\u003cstrong data-mce-fragment=\"1\"\u003eDigital Diagnostic Monitor\u003c\/strong\u003e) function that can easily monitor real-time parameters of the SFP for network administrator, such as optical output power, optical input power, temperature, laser bias current and transceiver supply voltage.\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cimg class=\"img-fluid\" height=\"350\" width=\"700\" alt=\"\" src=\"https:\/\/planet.com.tw\/storage\/products\/49676\/Common_Intelligent-SFP_SFP+-Diagnosis-Mechanism.png\" data-mce-src=\"https:\/\/planet.com.tw\/storage\/products\/49676\/Common_Intelligent-SFP_SFP+-Diagnosis-Mechanism.png\" data-mce-fragment=\"1\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePhysical Port\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e8-port 10\/100\/1000BASE-T\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eRJ45 copper with\u003cstrong\u003e\u003cspan\u003e \u003c\/span\u003ePoE\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003einjector function\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e2 100\/1000BASE-X SFP\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eslots\u003c\/li\u003e\n\u003cli\u003eRJ45 console interface for switch basic management and setup  \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSwitching\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eHardware-based 10\/100Mbps, half\/full duplex and 1000Mbps full duplex mode, flow control and auto-negotiation, and auto MDI\/MDI-X\u003c\/li\u003e\n\u003cli\u003eFeatures Store-and-Forward mode with wire-speed filtering and forwarding rates\u003c\/li\u003e\n\u003cli\u003eIEEE 802.3x flow control for full duplex operation and back pressure for half duplex operation\u003c\/li\u003e\n\u003cli\u003e10K jumbo frame\u003c\/li\u003e\n\u003cli\u003eAutomatic address learning and address aging\u003c\/li\u003e\n\u003cli\u003eSupports CSMA\/CD protocol\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePower over Ethernet\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eComplies with IEEE 802.3bt PoE++ standard PSE\u003c\/li\u003e\n\u003cli\u003eBackward compatible with IEEE 802.3at PoE+ and 802.3af Power over Ethernet\u003c\/li\u003e\n\u003cli\u003ePorts 1 to 8 support up to 95 watts \u003c\/li\u003e\n\u003cli\u003eEach PoE port supports 54V DC power to powered device\u003c\/li\u003e\n\u003cli\u003e180-watt PoE budget\u003c\/li\u003e\n\u003cli\u003eAuto detects powered device\u003c\/li\u003e\n\u003cli\u003eCircuit protection prevents power interference between ports\u003c\/li\u003e\n\u003cli\u003eRemote power feeding up to 100 meters in standard mode and 250m in extended mode\u003c\/li\u003e\n\u003cli\u003ePoE management\n\u003cul\u003e\n\u003cli\u003eTotal PoE function enable\/disable\u003c\/li\u003e\n\u003cli\u003ePoE PD Type for Standard\/Legacy\/UPOE mode option\u003c\/li\u003e\n\u003cli\u003eTemperature Threshold\u003c\/li\u003e\n\u003cli\u003ePer port PoE function enable\/disable\u003c\/li\u003e\n\u003cli\u003ePoE port power feeding priority\u003c\/li\u003e\n\u003cli\u003ePer PoE port power limitation\u003c\/li\u003e\n\u003cli\u003ePD classification detection\u003c\/li\u003e\n\u003cli\u003ePoE extension\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eIntelligent PoE features\n\u003cul\u003e\n\u003cli\u003ePD alive check\u003c\/li\u003e\n\u003cli\u003ePoE schedule\u003c\/li\u003e\n\u003cli\u003eScheduled power recycling\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eLayer 2 Features\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ePrevents packet loss with back pressure (half-duplex) and IEEE 802.3x pause frame flow control (full-duplex)\u003c\/li\u003e\n\u003cli\u003eHigh performance Store and Forward architecture, broadcast storm control, and runt\/CRC filtering that eliminates erroneous packets to optimize the network bandwidth\u003c\/li\u003e\n\u003cli\u003eSupports\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eVLAN\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eIEEE 802.1Q tagged VLAN\u003c\/li\u003e\n\u003cli\u003eProvider Bridging (VLAN Q-in-Q) support (IEEE 802.1ad)\u003c\/li\u003e\n\u003cli\u003eProtocol VLAN\u003c\/li\u003e\n\u003cli\u003eVoice VLAN\u003c\/li\u003e\n\u003cli\u003ePrivate VLAN (Protected port)\u003c\/li\u003e\n\u003cli\u003eManagement VLAN\u003c\/li\u003e\n\u003cli\u003eGVRP\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eSupports\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSpanning Tree Protocol\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eSTP (Spanning Tree Protocol)\u003c\/li\u003e\n\u003cli\u003eRSTP (Rapid Spanning Tree Protocol)\u003c\/li\u003e\n\u003cli\u003eMSTP (Multiple Spanning Tree Protocol)\u003c\/li\u003e\n\u003cli\u003eSTP BPDU Guard, BPDU filtering and BPDU forwarding\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eSupports\u003cstrong\u003e\u003cspan\u003e \u003c\/span\u003eLink Aggregation\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eIEEE 802.3ad Link Aggregation Control Protocol (LACP)\u003c\/li\u003e\n\u003cli\u003eCisco ether-channel (static trunk)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eProvides port mirror (many-to-1)\u003c\/li\u003e\n\u003cli\u003eLoop protection to avoid broadcast loops\u003c\/li\u003e\n\u003cli\u003eSupports ERPS (Ethernet Ring Protection Switching)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQuality of Service\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eIngress and egress rate limit per port bandwidth control\u003c\/li\u003e\n\u003cli\u003eStorm control support\n\u003cul\u003e\n\u003cli\u003eBroadcast\/Unknown unicast\/Unknown multicast\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eTraffic classification\n\u003cul\u003e\n\u003cli\u003eIEEE 802.1p CoS\u003c\/li\u003e\n\u003cli\u003eTOS\/DSCP\/IP precedence of IPv4\/IPv6 packets\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eStrict priority and Weighted Round Robin (WRR) CoS policies\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMulticast\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSupports IPv4 IGMP snooping v2 and v3\u003c\/li\u003e\n\u003cli\u003eSupports IPv6 MLD snooping v1, v2\u003c\/li\u003e\n\u003cli\u003eIGMP querier mode support\u003c\/li\u003e\n\u003cli\u003eIGMP snooping port filtering\u003c\/li\u003e\n\u003cli\u003eMLD snooping port filtering\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSecurity\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eAuthentication\n\u003cul\u003e\n\u003cli\u003eIEEE 802.1X port-based network access authentication\u003c\/li\u003e\n\u003cli\u003eBuilt-in RADIUS client to cooperate with the RADIUS servers\u003c\/li\u003e\n\u003cli\u003eRADIUS\/TACACS+ login user access authentication\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eAccess control list\n\u003cul\u003e\n\u003cli\u003eIPv4\/IPv6 IP-based ACL\u003c\/li\u003e\n\u003cli\u003eMAC-based ACL\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eMAC security\n\u003cul\u003e\n\u003cli\u003eStatic MAC\u003c\/li\u003e\n\u003cli\u003eMAC filtering\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003ePort security for source MAC address entries filtering\u003c\/li\u003e\n\u003cli\u003eDHCP snooping to filter distrusted DHCP messages\u003c\/li\u003e\n\u003cli\u003eDynamic ARP Inspection discards ARP packets with invalid MAC address to IP address binding\u003c\/li\u003e\n\u003cli\u003eIP source guard prevents IP spoofing attacks\u003c\/li\u003e\n\u003cli\u003eDoS attack prevention\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eManagement\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eIPv4 and IPv6 dual stack management\u003c\/li\u003e\n\u003cli\u003eSwitch management interface\n\u003cul\u003e\n\u003cli\u003eWeb switch management \u003c\/li\u003e\n\u003cli\u003eConsole and telnet command line interface\u003c\/li\u003e\n\u003cli\u003eSNMP v1 and v2c switch management\u003c\/li\u003e\n\u003cli\u003eSSHv2, TLSv1.2 and SNMP v3 secure access\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eSNMP Management\n\u003cul\u003e\n\u003cli\u003eFour RMON groups (history, statistics, alarms and events) \u003c\/li\u003e\n\u003cli\u003eSNMP trap for interface link up and link down notification\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eUser privilege levels control\u003c\/li\u003e\n\u003cli\u003eBuilt-in Trivial File Transfer Protocol (TFTP) client\u003c\/li\u003e\n\u003cli\u003eBOOTP and DHCP for IP address assignment\u003c\/li\u003e\n\u003cli\u003eSystem maintenance\n\u003cul\u003e\n\u003cli\u003eFirmware upload\/download via HTTP\/TFTP\u003c\/li\u003e\n\u003cli\u003eConfiguration upload\/download through HTTP\/TFTP\u003c\/li\u003e\n\u003cli\u003eDual images\u003c\/li\u003e\n\u003cli\u003eHardware reset button for system reboot or reset to factory default\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eSNTP Network Time Protocol\u003c\/li\u003e\n\u003cli\u003eNetwork Diagnostic\n\u003cul\u003e\n\u003cli\u003eSFP-DDM (digital diagnostic monitor)\u003c\/li\u003e\n\u003cli\u003eCable diagnostics\u003c\/li\u003e\n\u003cli\u003eICMPv4\/ICMPv6 remote ping\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eLink Layer Discovery Protocol (LLDP) and LLDP-MED\u003c\/li\u003e\n\u003cli\u003eEvent message logging to remote syslog server\u003c\/li\u003e\n\u003cli\u003ePLANET Smart Discovery Utility for deployment management\u003c\/li\u003e\n\u003cli\u003ePLANET NMS system and CloudViewer\/CloudViewerPro for deployment management\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ctable class=\"table table-sm table-bordered-bone table-striped-blue table-header-theme-blue table-header-no-border\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\"\u003eHardware Specifications\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eCopper Ports\u003c\/td\u003e\n\u003ctd\u003e8 x 10\/100\/1000BASE-T RJ45 auto-MDI\/MDI-X port\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eSFP Slots\u003c\/td\u003e\n\u003ctd\u003e2 x 100\/1000BASE-X SFP interface\u003cbr\u003eSupports 100\/1000Mbps dual mode and DDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003ePoE Injector Port\u003c\/td\u003e\n\u003ctd\u003e8 ports with 802.3bt PoE++ injector function (Ports 1 to 8)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eReset Button\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 5 sec: System reboot\u003cbr\u003e\u0026gt; 5 sec: Factory default\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003ePower Requirements\u003c\/td\u003e\n\u003ctd\u003e100~240V AC, 50\/60Hz, auto-sensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eDimensions (W x D x H)\u003c\/td\u003e\n\u003ctd\u003e280 x 180 x 44 mm, 1U height\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eESD Protection\u003c\/td\u003e\n\u003ctd\u003eContact Discharge 6KV DC\u003cbr\u003eAir Discharge 8KV DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eEnclosure\u003c\/td\u003e\n\u003ctd\u003eMetal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1800g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003ePower Consumption\/Dissipation\u003c\/td\u003e\n\u003ctd\u003e203 watts (max.)\/692 BTU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eLED\u003c\/td\u003e\n\u003ctd\u003e\n\u003cb\u003eSystem:\u003c\/b\u003e\u003cbr\u003e　PWR x1(\u003cspan style=\"color: green;\"\u003e\u003cb\u003eGreen\u003c\/b\u003e\u003c\/span\u003e)\u003cbr\u003e　SYS x1 (\u003cspan style=\"color: green;\"\u003e\u003cb\u003eGreen\u003c\/b\u003e\u003c\/span\u003e)\u003cbr\u003e\u003cb\u003ePoE Ports (Port 1 to Port 8):\u003c\/b\u003e\u003cbr\u003e　LNK\/ACT x1 (\u003cspan style=\"color: green;\"\u003e\u003cb\u003eGreen\u003c\/b\u003e\u003c\/span\u003e)\u003cbr\u003e　PoE-in-use x1 (\u003cspan style=\"color: orange;\"\u003e\u003cb\u003eAmber\u003c\/b\u003e\u003c\/span\u003e)\u003cbr\u003e\u003cb\u003eGigabit SFP Ports (Port 9 to Port 10):\u003c\/b\u003e\u003cbr\u003e　100\/1000 LNK\/ACT x1 (\u003cspan style=\"color: green;\"\u003e\u003cb\u003eGreen\u003c\/b\u003e\u003c\/span\u003e)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\"\u003eSwitch Specifications\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eSwitch Architecture\u003c\/td\u003e\n\u003ctd\u003eStore-and-Forward\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eSwitch Fabric\u003c\/td\u003e\n\u003ctd\u003e20Gbps\/non-blocking\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eSwitch Throughput@64Bytes\u003c\/td\u003e\n\u003ctd\u003e14.88Mpps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eAddress Table\u003c\/td\u003e\n\u003ctd\u003e8K entries\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eShared Data Buffer\u003c\/td\u003e\n\u003ctd\u003e4.1 megabits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eFlow Control\u003c\/td\u003e\n\u003ctd\u003eIEEE 802.3x pause frame for full duplex\u003cbr\u003eBack pressure for half duplex\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eJumbo Frame\u003c\/td\u003e\n\u003ctd\u003e10K bytes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\"\u003ePower over Ethernet\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003ePoE Standard\u003c\/td\u003e\n\u003ctd\u003eIEEE 802.3bt PoE++ PSE\u003cbr\u003eIEEE 802.3af\/at PoE+ PSE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003ePoE Power Supply Type\u003c\/td\u003e\n\u003ctd\u003e802.3bt (Ports1 to 8)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003ePoE Power Output\u003c\/td\u003e\n\u003ctd\u003ePer PoE port 54V DC, max. 95 watts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003ePower Pin Assignment\u003c\/td\u003e\n\u003ctd\u003e802.3bt: 1\/2 (+), 3\/6 (-),4\/5 (-), 7\/8 (+)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003ePoE Power Budget\u003c\/td\u003e\n\u003ctd\u003e180 watts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003ePoE Ability PD @ 12.5 watts\u003c\/td\u003e\n\u003ctd\u003e8 units with standard mode\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003ePoE Ability PD @ 25 watts\u003c\/td\u003e\n\u003ctd\u003e7 units with standard mode\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003ePoE Ability PD @ 51 watts\u003c\/td\u003e\n\u003ctd\u003e3 units with standard mode\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003ePoE Ability PD @ 71 watts\u003c\/td\u003e\n\u003ctd\u003e2 units with standard mode\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\"\u003ePoE Management Functions\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eActive PoE Device Detection\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003ePoE Power Recycling\u003c\/td\u003e\n\u003ctd\u003eYes, daily or predefined schedule\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003ePoE Schedule\u003c\/td\u003e\n\u003ctd\u003e4 schedule profiles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003ePD Alive Check\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003ePoE Extend Mode\u003c\/td\u003e\n\u003ctd\u003eYes, max. up to 250 meters\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003ePoE Port Management\u003c\/td\u003e\n\u003ctd\u003ePort Enable\/Disable\/Schedule\u003cbr\u003ePoE Power Inline Mode\u003cbr\u003e　802.3bt\u003cbr\u003ePoE PD Type\u003cbr\u003e　Standard\/Legacy\/UPOE mode option\u003cbr\u003ePort Priority\u003cbr\u003e　Critical\/High\/Low mode option\u003cbr\u003ePD Class\/Current Used[mA]\/Power Used[W]\u003cbr\u003e　Real Time Display\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\"\u003eLayer 2 Functions\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003ePort Mirroring\u003c\/td\u003e\n\u003ctd\u003eTX\/RX\/both\u003cbr\u003eMany-to-1 monitor\u003cbr\u003eUp to 4 sessions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eVLAN\u003c\/td\u003e\n\u003ctd\u003e802.1Q tag-based VLAN\u003cbr\u003eUp to 256 VLAN groups, out of 4094 VLAN IDs\u003cbr\u003e802.1ad Q-in-Q tunneling\u003cbr\u003eVoice VLAN\u003cbr\u003eProtocol VLAN\u003cbr\u003ePrivate VLAN (Protected port)\u003cbr\u003eGVRP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eLink Aggregation\u003c\/td\u003e\n\u003ctd\u003eIEEE 802.3ad LACP and static trunk\u003cbr\u003eSupports 5 groups of 8-port trunk\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eSpanning Tree Protocol\u003c\/td\u003e\n\u003ctd\u003eIEEE 802.1D Spanning Tree Protocol (STP)\u003cbr\u003eIEEE 802.1w Rapid Spanning Tree Protocol (RSTP)\u003cbr\u003eIEEE 802.1s Multiple Spanning Tree Protocol (MSTP)\u003cbr\u003eSTP BPDU Guard, BPDU Filtering and BPDU Forwarding\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eIGMP Snooping\u003c\/td\u003e\n\u003ctd\u003eIGMP (v2\/v3) snooping\u003cbr\u003eIGMP querier\u003cbr\u003eUp to 256 multicast groups\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eMLD Snooping\u003c\/td\u003e\n\u003ctd\u003eMLD (v1\/v2) snooping, up to 256 multicast groups\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eQoS\u003c\/td\u003e\n\u003ctd\u003e8 mapping IDs to 8 level priority queues\u003cbr\u003e　Port number\u003cbr\u003e　802.1p priority\u003cbr\u003e　802.1Q VLAN tag\u003cbr\u003e　DSCP field in IP packet\u003cbr\u003eTraffic classification based, strict priority and WRR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eRing\u003c\/td\u003e\n\u003ctd\u003eSupports ERPS, and complies with ITU-T G.8032\u003cbr\u003eRecovery time \u0026lt; 450ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\"\u003eSecurity Functions\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eAccess Control List\u003c\/td\u003e\n\u003ctd\u003eIPv4\/IPv6 IP-based ACL\/MAC-based ACL\u003cbr\u003eMax. 256 ACL entries\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003ePort Security\u003c\/td\u003e\n\u003ctd\u003eIEEE 802.1X – Port-based authentication\u003cbr\u003eBuilt-in RADIUS client to co-operate with RADIUS server\u003cbr\u003eRADIUS\/TACACS+ user access authentication\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eMAC Security\u003c\/td\u003e\n\u003ctd\u003eIP-MAC port binding\u003cbr\u003eMAC filter\u003cbr\u003eStatic MAC address, max. 256 static MAC entries\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eEnhanced Security\u003c\/td\u003e\n\u003ctd\u003eDHCP Snooping and DHCP Option82\u003cbr\u003eSTP BPDU guard, BPDU filtering and BPDU forwarding\u003cbr\u003eDoS attack prevention\u003cbr\u003eARP inspection\u003cbr\u003eIP source guard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\"\u003eManagement Functions\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eBasic Management Interfaces\u003c\/td\u003e\n\u003ctd\u003eWeb browser; Telnet; SNMP v1, v2c\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eSecure Management Interfaces\u003c\/td\u003e\n\u003ctd\u003eSSHv2, TLSv1.2, SNMP v3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eSystem Management\u003c\/td\u003e\n\u003ctd\u003eFirmware upgrade by HTTP\/TFTP protocol through Ethernet network\u003cbr\u003eLLDP protocol\u003cbr\u003eSNTP\u003cbr\u003ePLANET Smart Discovery Utility\u003cbr\u003ePLANET NMS System and CloudViewer\/CloudViewerPro app\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eEvent Management\u003c\/td\u003e\n\u003ctd\u003eRemote\/Local Syslog\u003cbr\u003eSystem log\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eSNMP MIBs\u003c\/td\u003e\n\u003ctd\u003eRFC 1213 MIB-II\u003cbr\u003eRFC 1215 Generic Traps\u003cbr\u003eRFC 1493 Bridge MIB\u003cbr\u003eRFC 2674 Bridge MIB Extensions\u003cbr\u003eRFC 2737 Entity MIB (v2)\u003cbr\u003eRFC 2819 RMON (1, 2, 3, 9)\u003cbr\u003eRFC 2863 Interface Group MIB\u003cbr\u003eRFC 3635 Ethernet-like MIB\u003cbr\u003eRFC 3621 Power Ethernet MIB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\"\u003eStandards Conformance\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eRegulatory Compliance\u003c\/td\u003e\n\u003ctd\u003eFCC Part 15 Class A, CE, LVD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eStandards Compliance\u003c\/td\u003e\n\u003ctd\u003eIEEE 802.3 10BASE-T\u003cbr\u003eIEEE 802.3u 100BASE-TX\/100BASE-FX\u003cbr\u003eIEEE 802.3z Gigabit SX\/LX\u003cbr\u003eIEEE 802.3ab Gigabit 1000T\u003cbr\u003eIEEE 802.3x flow control and back pressure\u003cbr\u003eIEEE 802.3ad port trunk with LACP\u003cbr\u003eIEEE 802.1D Spanning Tree Protocol\u003cbr\u003eIEEE 802.1w Rapid Spanning Tree Protocol\u003cbr\u003eIEEE 802.1s Multiple Spanning Tree Protocol\u003cbr\u003eIEEE 802.1p Class of Service\u003cbr\u003eIEEE 802.1Q VLAN tagging\u003cbr\u003eIEEE 802.1x Port Authentication Network Control\u003cbr\u003eIEEE 802.1ab LLDP\u003cbr\u003eIEEE 802.3af Power over Ethernet\u003cbr\u003eIEEE 802.3at Power over Ethernet Plus\u003cbr\u003eIEEE 802.3bt Power over Ethernet Plus Plus\u003cbr\u003eIEEE 802.3az Energy Efficient Ethernet (EEE)\u003cbr\u003eRFC 768 UDP\u003cbr\u003eRFC 783 TFTP\u003cbr\u003eRFC 793 TCP\u003cbr\u003eRFC 791 IP\u003cbr\u003eRFC 792 ICMP\u003cbr\u003eRFC 2068 HTTP\u003cbr\u003eRFC 1112 IGMP v1\u003cbr\u003eRFC 2236 IGMP v2\u003cbr\u003eRFC 3376 IGMP v3\u003cbr\u003eRFC 2710 MLD v1\u003cbr\u003eRFC 3810 MLD v2\u003cbr\u003eITU G.8032 ERPS Ring\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\"\u003eEnvironment\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0~50 degrees C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-10 ~ 70 degrees C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eHumidity\u003c\/td\u003e\n\u003ctd\u003e5 ~ 95% (non-condensing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\"\u003eStandard Accessories\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003ePacket Contents\u003c\/td\u003e\n\u003ctd\u003eGS-4210-8UP2S x 1\u003cbr\u003eQR Code Sheet x 1\u003cbr\u003eCloudViewerPro App Quick Guide x1\u003cbr\u003eRS232 to RJ45 Console Cable x 1\u003cbr\u003eRubber Feet x 4\u003cbr\u003eRack-mounting Package x 1\u003cbr\u003ePower Cord x 1\u003cbr\u003eSFP Dust Caps x 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Planet","offers":[{"title":"Default Title","offer_id":48892950577408,"sku":"GS-4210-8UP2S","price":358.4,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0388\/5331\/2557\/files\/box_GS-4210-8UP2S.jpg?v=1782490962","url":"https:\/\/alotechparts.com\/pt-br\/products\/planet-gs-4210-8up2s-ipv6ipv4-8-port-101001000t-8023bt-95w-poe-2-port-100","provider":"Alo Tech Solutions","version":"1.0","type":"link"}