{"product_id":"juniper-qfx10008-redund-h-chassis","title":"Chassi Juniper QFX10008-REDUND-H","description":"\u003cdiv class=\"short-hide\"\u003e[shortdesc]\n\u003cul\u003e\n\n\n\u003cli\u003eQFX10008\u003c\/li\u003e\n\n\u003cli\u003eChassi de 8 slots\u003c\/li\u003e\n\n\u003cli\u003e6 fontes de alimentação compatíveis com HVDC\u003c\/li\u003e\n\n\u003cli\u003e2 bandejas de ventilador\u003c\/li\u003e\n\n\u003cli\u003e2 controladores de bandeja de ventilador\u003c\/li\u003e\n\n\u003cli\u003e6 placas de tecido de switch\u003c\/li\u003e\n\n\u003cli\u003e2 motores de roteamento\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n[\/shortdesc]\u003c\/div\u003e\n[properties]\n\u003ctable width=\"496\" data-mce-fragment=\"1\"\u003e\n\n\u003ctbody data-mce-fragment=\"1\"\u003e\n\n\u003ctr data-mce-fragment=\"1\"\u003e\n\n\u003ctd width=\"206\" data-mce-fragment=\"1\"\u003ePropriedades\u003c\/td\u003e\n\n\u003ctd width=\"290\" data-mce-fragment=\"1\"\u003eJuniper QFX10008-REDUND-H\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr data-mce-fragment=\"1\"\u003e\n\n\u003ctd width=\"206\" data-mce-fragment=\"1\"\u003eDescrição\u003c\/td\u003e\n\n\u003ctd width=\"290\" data-mce-fragment=\"1\"\u003eChassi QFX10008 Redundante de 8 slots com 2 CBs, 6 fontes de alimentação compatíveis com HVDC, 2 bandejas de ventilador, 2 controladores de bandeja de ventilador e 6 placas de tecido de switch\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr data-mce-fragment=\"1\"\u003e\n\n\u003ctd width=\"206\" data-mce-fragment=\"1\"\u003eFamília de Produtos\u003c\/td\u003e\n\n\u003ctd data-mce-fragment=\"1\"\u003eSérie QFX10008\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr data-mce-fragment=\"1\"\u003e\n\n\u003ctd width=\"206\" data-mce-fragment=\"1\"\u003eTipo de Produto\u003c\/td\u003e\n\n\u003ctd data-mce-fragment=\"1\"\u003eChassi Base\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr data-mce-fragment=\"1\"\u003e\n\n\u003ctd colspan=\"2\" data-mce-fragment=\"1\"\u003eDensidades Máximas de Porta\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr data-mce-fragment=\"1\"\u003e\n\n\u003ctd data-mce-fragment=\"1\"\u003eDensidade máxima de porta 10GbE\u003c\/td\u003e\n\n\u003ctd data-mce-fragment=\"1\"\u003e1.152\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr data-mce-fragment=\"1\"\u003e\n\n\u003ctd data-mce-fragment=\"1\"\u003eDensidade máxima de porta 40GbE\u003c\/td\u003e\n\n\u003ctd data-mce-fragment=\"1\"\u003e288\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr data-mce-fragment=\"1\"\u003e\n\n\u003ctd data-mce-fragment=\"1\"\u003eDensidade máxima de porta 100GbE\u003c\/td\u003e\n\n\u003ctd data-mce-fragment=\"1\"\u003e240\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr data-mce-fragment=\"1\"\u003e\n\n\u003ctd data-mce-fragment=\"1\"\u003eSistema Operacional\u003c\/td\u003e\n\n\u003ctd width=\"290\" data-mce-fragment=\"1\"\u003eJunos OS\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr data-mce-fragment=\"1\"\u003e\n\n\u003ctd data-mce-fragment=\"1\"\u003eArquitetura\u003c\/td\u003e\n\n\u003ctd width=\"290\" data-mce-fragment=\"1\"\u003eArquitetura de interconexão ortogonal sem placa intermediária\u003cbr data-mce-fragment=\"1\"\u003e Planos de dados, controle e gerenciamento dedicados separados\u003cbr data-mce-fragment=\"1\"\u003e Arquitetura modular segura que isola falhas\u003cbr data-mce-fragment=\"1\"\u003e Failover transparente e recuperação de rede\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr data-mce-fragment=\"1\"\u003e\n\n\u003ctd data-mce-fragment=\"1\"\u003ePlaca de Controle\u003c\/td\u003e\n\n\u003ctd width=\"290\" data-mce-fragment=\"1\"\u003eCBs primárias e de backup (redundância 1+1)\u003cbr data-mce-fragment=\"1\"\u003e CPU Intel Quad Core de 2.5GHz\u003cbr data-mce-fragment=\"1\"\u003e 32 gigabytes de SDRAM\u003cbr data-mce-fragment=\"1\"\u003e SSD on-board de 50 gigabytes\u003cbr data-mce-fragment=\"1\"\u003e Unidade de estado sólido (SSD) conectável\u003cbr data-mce-fragment=\"1\"\u003e Interface de armazenamento USB 2.0\u003cbr data-mce-fragment=\"1\"\u003e Quatro portas SFP\/SFP+ compatíveis com MACsec\u003cbr data-mce-fragment=\"1\"\u003e Porta de gerenciamento Ethernet de Fibra (SFP) ou 10\/100\/1000BASE-T (RJ-45)\u003cbr data-mce-fragment=\"1\"\u003e Uma porta de console\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr data-mce-fragment=\"1\"\u003e\n\n\u003ctd width=\"206\" data-mce-fragment=\"1\"\u003eNúmero total de slots de E\/S\u003c\/td\u003e\n\n\u003ctd data-mce-fragment=\"1\"\u003e8\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr data-mce-fragment=\"1\"\u003e\n\n\u003ctd data-mce-fragment=\"1\"\u003ePotência\u003c\/td\u003e\n\n\u003ctd width=\"290\" data-mce-fragment=\"1\"\u003eCom 6 fontes de alimentação compatíveis com HVDC\u003cbr data-mce-fragment=\"1\"\u003e Suporta até seis fontes de alimentação:\u003cbr data-mce-fragment=\"1\"\u003e -40 a -72 VCC\u003cbr data-mce-fragment=\"1\"\u003e 200 a 240 VCA\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr data-mce-fragment=\"1\"\u003e\n\n\u003ctd data-mce-fragment=\"1\"\u003ePotência Típica\u003c\/td\u003e\n\n\u003ctd data-mce-fragment=\"1\"\u003e1.765 W\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr data-mce-fragment=\"1\"\u003e\n\n\u003ctd data-mce-fragment=\"1\"\u003ePotência Reservada\u003c\/td\u003e\n\n\u003ctd data-mce-fragment=\"1\"\u003e2.877 W\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr data-mce-fragment=\"1\"\u003e\n\n\u003ctd data-mce-fragment=\"1\"\u003eSaída Térmica Máxima\u003c\/td\u003e\n\n\u003ctd width=\"290\" data-mce-fragment=\"1\"\u003e48.156 BTU\/hora (14.113 W)\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr data-mce-fragment=\"1\"\u003e\n\n\u003ctd data-mce-fragment=\"1\"\u003eResfriamento\u003c\/td\u003e\n\n\u003ctd width=\"290\" data-mce-fragment=\"1\"\u003eFluxo de ar frontal-traseiro\u003cbr data-mce-fragment=\"1\"\u003e Duas bandejas de ventilador de troca a quente com ventiladores redundantes\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr data-mce-fragment=\"1\"\u003e\n\n\u003ctd data-mce-fragment=\"1\"\u003eDimensões (L x A x P)\u003c\/td\u003e\n\n\u003ctd width=\"290\" data-mce-fragment=\"1\"\u003e17,4 x 22,55 x 32 pol.\u003cbr data-mce-fragment=\"1\"\u003e (44,2 x 57,3 x 81,3 cm)\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr data-mce-fragment=\"1\"\u003e\n\n\u003ctd data-mce-fragment=\"1\"\u003ePeso\u003c\/td\u003e\n\n\u003ctd data-mce-fragment=\"1\"\u003e322 lbs (146 kg)\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr data-mce-fragment=\"1\"\u003e\n\n\u003ctd width=\"206\" data-mce-fragment=\"1\"\u003ePeso do chassi totalmente carregado\u003c\/td\u003e\n\n\u003ctd width=\"290\" data-mce-fragment=\"1\"\u003e493 lbs (224 kg)\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr data-mce-fragment=\"1\"\u003e\n\n\u003ctd data-mce-fragment=\"1\"\u003eUnidades de rack\u003c\/td\u003e\n\n\u003ctd data-mce-fragment=\"1\"\u003e13 U\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\n\u003c\/tbody\u003e\n\n\n\u003c\/table\u003e\n[\/properties]\u003cbr\u003e\u003cbr\u003e[specifications]\n\u003ctable width=\"789\" data-mce-fragment=\"1\"\u003e\n\n\u003ctbody data-mce-fragment=\"1\"\u003e\n\n\u003ctr data-mce-fragment=\"1\"\u003e\n\n\u003ctd width=\"395\" data-mce-fragment=\"1\"\u003eEspecificações\u003c\/td\u003e\n\n\u003ctd width=\"394\" data-mce-fragment=\"1\"\u003eQFX10008-REDUND-H\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr data-mce-fragment=\"1\"\u003e\n\n\u003ctd width=\"395\" data-mce-fragment=\"1\"\u003eVazão do sistema\u003c\/td\u003e\n\n\u003ctd width=\"394\" data-mce-fragment=\"1\"\u003eAté 48 Tbps\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr data-mce-fragment=\"1\"\u003e\n\n\u003ctd data-mce-fragment=\"1\"\u003eCapacidade de encaminhamento\u003c\/td\u003e\n\n\u003ctd width=\"394\" data-mce-fragment=\"1\"\u003eAté 16 Bpps\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr data-mce-fragment=\"1\"\u003e\n\n\u003ctd data-mce-fragment=\"1\"\u003eLargura de banda máxima\/slot\u003c\/td\u003e\n\n\u003ctd data-mce-fragment=\"1\"\u003e7,2 Tbps\/slot\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr data-mce-fragment=\"1\"\u003e\n\n\u003ctd width=\"395\" data-mce-fragment=\"1\"\u003eTecido\u003c\/td\u003e\n\n\u003ctd width=\"394\" data-mce-fragment=\"1\"\u003eCapacidade de tecido bruto de até 86,4 Tbps\u003cbr data-mce-fragment=\"1\"\u003e Capacidade de tecido utilizável de até 7,2 Tbps (full duplex) por slot\u003cbr data-mce-fragment=\"1\"\u003e Redundância de tecido 5+1\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr data-mce-fragment=\"1\"\u003e\n\n\u003ctd width=\"395\" data-mce-fragment=\"1\"\u003eLatência\u003c\/td\u003e\n\n\u003ctd width=\"394\" data-mce-fragment=\"1\"\u003eTão baixa quanto 2,5 microssegundos dentro de um PFE\u003cbr data-mce-fragment=\"1\"\u003e Tão baixa quanto 5,5 microssegundos entre PFEs\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr data-mce-fragment=\"1\"\u003e\n\n\u003ctd width=\"395\" data-mce-fragment=\"1\"\u003eEndereços de controle de acesso à mídia (MAC)\u003c\/td\u003e\n\n\u003ctd data-mce-fragment=\"1\"\u003eAté 1 milhão\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr data-mce-fragment=\"1\"\u003e\n\n\u003ctd data-mce-fragment=\"1\"\u003eEntradas ARP\u003c\/td\u003e\n\n\u003ctd data-mce-fragment=\"1\"\u003eAté 510.000, ou 64.000 por PFE\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr data-mce-fragment=\"1\"\u003e\n\n\u003ctd data-mce-fragment=\"1\"\u003eJumbo frames\u003c\/td\u003e\n\n\u003ctd data-mce-fragment=\"1\"\u003e9.216 Bytes máximo\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr data-mce-fragment=\"1\"\u003e\n\n\u003ctd data-mce-fragment=\"1\"\u003eVLANs\u003c\/td\u003e\n\n\u003ctd data-mce-fragment=\"1\"\u003e4.093\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr data-mce-fragment=\"1\"\u003e\n\n\u003ctd data-mce-fragment=\"1\"\u003eBase de informações de encaminhamento (FIB) (IPv4\/IPv6)\u003c\/td\u003e\n\n\u003ctd data-mce-fragment=\"1\"\u003eAté 2 milhões\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr data-mce-fragment=\"1\"\u003e\n\n\u003ctd data-mce-fragment=\"1\"\u003eRotas de host\u003c\/td\u003e\n\n\u003ctd data-mce-fragment=\"1\"\u003eAté 2 milhões\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr data-mce-fragment=\"1\"\u003e\n\n\u003ctd data-mce-fragment=\"1\"\u003eECMP\u003c\/td\u003e\n\n\u003ctd data-mce-fragment=\"1\"\u003e64 vias\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr data-mce-fragment=\"1\"\u003e\n\n\u003ctd data-mce-fragment=\"1\"\u003eRotas Multicast IPv4\u003c\/td\u003e\n\n\u003ctd data-mce-fragment=\"1\"\u003eAté 128.000\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr data-mce-fragment=\"1\"\u003e\n\n\u003ctd data-mce-fragment=\"1\"\u003eRotas Multicast IPv6\u003c\/td\u003e\n\n\u003ctd data-mce-fragment=\"1\"\u003eAté 128.000\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr data-mce-fragment=\"1\"\u003e\n\n\u003ctd data-mce-fragment=\"1\"\u003eGrupos Multicast\u003c\/td\u003e\n\n\u003ctd data-mce-fragment=\"1\"\u003eAté 128.000\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr data-mce-fragment=\"1\"\u003e\n\n\u003ctd data-mce-fragment=\"1\"\u003eFiltros\u003c\/td\u003e\n\n\u003ctd data-mce-fragment=\"1\"\u003eAté 8.000\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr data-mce-fragment=\"1\"\u003e\n\n\u003ctd data-mce-fragment=\"1\"\u003eTermos de filtro\u003c\/td\u003e\n\n\u003ctd data-mce-fragment=\"1\"\u003eAté 64.000\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr data-mce-fragment=\"1\"\u003e\n\n\u003ctd data-mce-fragment=\"1\"\u003ePoliciadores\u003c\/td\u003e\n\n\u003ctd data-mce-fragment=\"1\"\u003eAté 8.000\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr data-mce-fragment=\"1\"\u003e\n\n\u003ctd data-mce-fragment=\"1\"\u003eFilas de saída por porta\u003c\/td\u003e\n\n\u003ctd data-mce-fragment=\"1\"\u003e8\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr data-mce-fragment=\"1\"\u003e\n\n\u003ctd data-mce-fragment=\"1\"\u003eFilas de Saída Virtuais\u003c\/td\u003e\n\n\u003ctd data-mce-fragment=\"1\"\u003e384.000 por PFE\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr data-mce-fragment=\"1\"\u003e\n\n\u003ctd data-mce-fragment=\"1\"\u003eGrupos de agregação de link (LAG)\u003c\/td\u003e\n\n\u003ctd data-mce-fragment=\"1\"\u003e1.000\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr data-mce-fragment=\"1\"\u003e\n\n\u003ctd data-mce-fragment=\"1\"\u003eSessões BFD distribuídas\u003c\/td\u003e\n\n\u003ctd data-mce-fragment=\"1\"\u003e200\/placa de linha\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr data-mce-fragment=\"1\"\u003e\n\n\u003ctd data-mce-fragment=\"1\"\u003eMembros \/ LAG\u003c\/td\u003e\n\n\u003ctd data-mce-fragment=\"1\"\u003e64\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr data-mce-fragment=\"1\"\u003e\n\n\u003ctd data-mce-fragment=\"1\"\u003eVizinhos BGP (Licença de Recurso Premium)\u003c\/td\u003e\n\n\u003ctd width=\"394\" data-mce-fragment=\"1\"\u003e1.024\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr data-mce-fragment=\"1\"\u003e\n\n\u003ctd data-mce-fragment=\"1\"\u003eTúneis GRE\u003c\/td\u003e\n\n\u003ctd data-mce-fragment=\"1\"\u003e2.000\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr data-mce-fragment=\"1\"\u003e\n\n\u003ctd data-mce-fragment=\"1\"\u003eTúneis VXLAN\u003c\/td\u003e\n\n\u003ctd data-mce-fragment=\"1\"\u003e1.000\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr data-mce-fragment=\"1\"\u003e\n\n\u003ctd data-mce-fragment=\"1\"\u003eVPNs MPLS Camada 3 (Licença de Recurso Avançado)\u003c\/td\u003e\n\n\u003ctd width=\"394\" data-mce-fragment=\"1\"\u003e4.096\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr data-mce-fragment=\"1\"\u003e\n\n\u003ctd data-mce-fragment=\"1\"\u003eLSPs (entrada\/saída\/trânsito) (Licença de Recurso Avançado)\u003c\/td\u003e\n\n\u003ctd width=\"394\" data-mce-fragment=\"1\"\u003e4.000\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr data-mce-fragment=\"1\"\u003e\n\n\u003ctd width=\"395\" data-mce-fragment=\"1\"\u003eVRFs\u003c\/td\u003e\n\n\u003ctd width=\"394\" data-mce-fragment=\"1\"\u003e4.000\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr data-mce-fragment=\"1\"\u003e\n\n\u003ctd colspan=\"2\" data-mce-fragment=\"1\"\u003eRecursos de Software\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr data-mce-fragment=\"1\"\u003e\n\n\u003ctd data-mce-fragment=\"1\"\u003eRecursos da Camada 2\u003c\/td\u003e\n\n\u003ctd width=\"394\" data-mce-fragment=\"1\"\u003e802.1D Spanning Tree Protocol (STP)\u003cbr data-mce-fragment=\"1\"\u003e 802.1w Rapid Spanning Tree Protocol (RSTP)\u003cbr data-mce-fragment=\"1\"\u003e 802.1s Multiple Spanning Tree Protocol (MSTP)\u003cbr data-mce-fragment=\"1\"\u003e VLAN Spanning Tree Protocol (VSTP)\u003cbr data-mce-fragment=\"1\"\u003e 802.1AB Link Layer Discovery Protocol (LLDP)\u003cbr data-mce-fragment=\"1\"\u003e VLAN Registration Protocol\u003cbr data-mce-fragment=\"1\"\u003e QinQ\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr data-mce-fragment=\"1\"\u003e\n\n\u003ctd data-mce-fragment=\"1\"\u003eAgregação de Link\u003c\/td\u003e\n\n\u003ctd width=\"394\" data-mce-fragment=\"1\"\u003e802.3ad Link Aggregation Control Protocol (LACP)\u003cbr data-mce-fragment=\"1\"\u003e Agregação de Link Multichassi (MC-LAG)\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr data-mce-fragment=\"1\"\u003e\n\n\u003ctd width=\"395\" data-mce-fragment=\"1\"\u003eRecursos da Camada 3\u003c\/td\u003e\n\n\u003ctd width=\"394\" data-mce-fragment=\"1\"\u003eBGP (Licença de Recurso Premium ou Licença de Recurso Avançado)\u003cbr data-mce-fragment=\"1\"\u003e Ethernet VPN (EVPN) Tipo 5\u003cbr data-mce-fragment=\"1\"\u003e Encaminhamento baseado em filtro\u003cbr data-mce-fragment=\"1\"\u003e OSPF v1\/v2\u003cbr data-mce-fragment=\"1\"\u003e OSPF v3\u003cbr data-mce-fragment=\"1\"\u003e Virtual Router Redundancy Protocol (VRRP)\u003cbr data-mce-fragment=\"1\"\u003e IPv6\u003cbr data-mce-fragment=\"1\"\u003e Detecção de Encaminhamento Bidirecional (BFD)\u003cbr data-mce-fragment=\"1\"\u003e Roteadores virtuais\u003cbr data-mce-fragment=\"1\"\u003e Encaminhamento de caminho reverso unicast (uRPF)\u003cbr data-mce-fragment=\"1\"\u003e Alternativa sem loop (LFA)\u003cbr data-mce-fragment=\"1\"\u003e IS-IS (Licença de Recurso Premium ou Licença de Recurso Avançado)\u003cbr data-mce-fragment=\"1\"\u003e Retransmissão DHCP v4\/v6\u003cbr data-mce-fragment=\"1\"\u003e DHCP consciente de VR\u003cbr data-mce-fragment=\"1\"\u003e IPv4 \/ IPv6 sobre túneis GRE (baseado em interface)\u003cbr data-mce-fragment=\"1\"\u003e Roteamento estático\u003cbr data-mce-fragment=\"1\"\u003e RIP v1\/v2\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr data-mce-fragment=\"1\"\u003e\n\n\u003ctd data-mce-fragment=\"1\"\u003eMulticast\u003c\/td\u003e\n\n\u003ctd width=\"394\" data-mce-fragment=\"1\"\u003eEVPN Tipo 6\/7\/8\u003cbr data-mce-fragment=\"1\"\u003e Internet Group Management Protocol (IGMP) v1\/v2\/v3\u003cbr data-mce-fragment=\"1\"\u003e Multicast Listener Discovery (MLD) v1\/v2\u003cbr data-mce-fragment=\"1\"\u003e Proxy IGMP, Querier\u003cbr data-mce-fragment=\"1\"\u003e Snooping IGMP\u003cbr data-mce-fragment=\"1\"\u003e Snooping MLD\u003cbr data-mce-fragment=\"1\"\u003e Protocol Independent Multicast PIM-SM, PIM-SSM, PIM-DM\u003cbr data-mce-fragment=\"1\"\u003e Multicast Source Discovery Protocol (MSDP)\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr data-mce-fragment=\"1\"\u003e\n\n\u003ctd data-mce-fragment=\"1\"\u003eFiltros de Firewall\u003c\/td\u003e\n\n\u003ctd width=\"394\" data-mce-fragment=\"1\"\u003eListas de controle de acesso (ACLs) L2-L4 de entrada e saída:\u003cbr data-mce-fragment=\"1\"\u003e - ACLs de porta\u003cbr data-mce-fragment=\"1\"\u003e - ACLs de VLAN\u003cbr data-mce-fragment=\"1\"\u003e - ACLs de roteador\u003cbr data-mce-fragment=\"1\"\u003e Proteção contra negação de serviço (DoS) do plano de controle\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr data-mce-fragment=\"1\"\u003e\n\n\u003ctd width=\"395\" data-mce-fragment=\"1\"\u003eQualidade de Serviço (QoS)\u003c\/td\u003e\n\n\u003ctd width=\"394\" data-mce-fragment=\"1\"\u003ePoliciador de três cores de taxa única\u003cbr data-mce-fragment=\"1\"\u003e Policiador de três cores de duas taxas\u003cbr data-mce-fragment=\"1\"\u003e Prevenção de congestionamento:\u003cbr data-mce-fragment=\"1\"\u003e - Detecção antecipada aleatória ponderada (WRED)\u003cbr data-mce-fragment=\"1\"\u003e - Descarte de cauda\u003cbr data-mce-fragment=\"1\"\u003e - Marcação de notificação explícita de congestionamento (ECN)\u003cbr data-mce-fragment=\"1\"\u003e Agendamento baseado em prioridade:\u003cbr data-mce-fragment=\"1\"\u003e - Enfileiramento de baixa latência com alta prioridade estrita\u003cbr data-mce-fragment=\"1\"\u003e - Enfileiramento round-robin ponderado (WRR)\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr data-mce-fragment=\"1\"\u003e\n\n\u003ctd width=\"395\" data-mce-fragment=\"1\"\u003eMPLS (Licença de Recurso Avançado)\u003c\/td\u003e\n\n\u003ctd width=\"394\" data-mce-fragment=\"1\"\u003eLDP\u003cbr data-mce-fragment=\"1\"\u003e RSVP\u003cbr data-mce-fragment=\"1\"\u003e Tunelamento LDP (LDP sobre RSVP)\u003cbr data-mce-fragment=\"1\"\u003e Reencaminhamento rápido (FRR)\u003cbr data-mce-fragment=\"1\"\u003e Tunelamento IPv6 (6PE)\u003cbr data-mce-fragment=\"1\"\u003e Caminhos de comutação de rótulos (LSPs) de entrada, trânsito e saída\u003cbr data-mce-fragment=\"1\"\u003e VPNs IPv4 Camada 3\u003cbr data-mce-fragment=\"1\"\u003e VPNs IPv6 Camada 3 (6VPE)\u003cbr data-mce-fragment=\"1\"\u003e Circuitos de Camada 2\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr data-mce-fragment=\"1\"\u003e\n\n\u003ctd width=\"395\" data-mce-fragment=\"1\"\u003eSobreposições (Licença de Recurso Premium ou Licença de Recurso Avançado)\u003c\/td\u003e\n\n\u003ctd width=\"394\" data-mce-fragment=\"1\"\u003eEVPN-VXLAN\u003cbr data-mce-fragment=\"1\"\u003e Gateway VXLAN L2 e L3\u003cbr data-mce-fragment=\"1\"\u003e Integração com o controlador VMware NSX SDN\u003cbr data-mce-fragment=\"1\"\u003e Open vSwitch Database (OVSDB)\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr data-mce-fragment=\"1\"\u003e\n\n\u003ctd width=\"395\" data-mce-fragment=\"1\"\u003eAlta Disponibilidade\u003c\/td\u003e\n\n\u003ctd width=\"394\" data-mce-fragment=\"1\"\u003eComutação de Mecanismo de Roteamento Graciosa (GRES)\u003cbr data-mce-fragment=\"1\"\u003e Roteamento ativo ininterrupto (NSR)\u003cbr data-mce-fragment=\"1\"\u003e Bridging ininterrupto (NSB)\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr data-mce-fragment=\"1\"\u003e\n\n\u003ctd width=\"395\" data-mce-fragment=\"1\"\u003eSincronização\u003c\/td\u003e\n\n\u003ctd width=\"394\" data-mce-fragment=\"1\"\u003ePrecision Timing Protocol (PTP)\u003cbr data-mce-fragment=\"1\"\u003e - Relógio transparente\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr data-mce-fragment=\"1\"\u003e\n\n\u003ctd width=\"395\" data-mce-fragment=\"1\"\u003eVisibilidade\u003c\/td\u003e\n\n\u003ctd width=\"394\" data-mce-fragment=\"1\"\u003eSwitched Port Analyzer (SPAN)\u003cbr data-mce-fragment=\"1\"\u003e RSPAN\u003cbr data-mce-fragment=\"1\"\u003e ERSPAN\u003cbr data-mce-fragment=\"1\"\u003e Espelhamento de porta baseado em filtro de firewall\u003cbr data-mce-fragment=\"1\"\u003e sFlow v5\u003cbr data-mce-fragment=\"1\"\u003e BGP Monitoring Protocol (BMP)\u003cbr data-mce-fragment=\"1\"\u003e IPFIX\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr data-mce-fragment=\"1\"\u003e\n\n\u003ctd width=\"395\" data-mce-fragment=\"1\"\u003eData Center Bridging\u003c\/td\u003e\n\n\u003ctd width=\"394\" data-mce-fragment=\"1\"\u003eControle de fluxo baseado em prioridade (PFC) IEEE 802.1Qbb\u003cbr data-mce-fragment=\"1\"\u003e Data Center Bridging Exchange Protocol (DCBX), DCBx FCoE,\u003cbr data-mce-fragment=\"1\"\u003e e TLVs (tipo, comprimento e valor) iSCSI\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr data-mce-fragment=\"1\"\u003e\n\n\u003ctd data-mce-fragment=\"1\"\u003eGerenciamento e Operações\u003c\/td\u003e\n\n\u003ctd width=\"394\" data-mce-fragment=\"1\"\u003eJuniper Space®\u003cbr data-mce-fragment=\"1\"\u003e  Network Director para Campus\u003cbr data-mce-fragment=\"1\"\u003e Junos OS CLI via console, telnet, SSH\u003cbr data-mce-fragment=\"1\"\u003e Gerenciamento fora de banda: Serial; 10\/100\/1000BASE-T\u003cbr data-mce-fragment=\"1\"\u003e Ethernet\u003cbr data-mce-fragment=\"1\"\u003e Gerenciamento e acesso CLI baseados em função\u003cbr data-mce-fragment=\"1\"\u003e Protocolo de gerenciamento Junos XML\u003cbr data-mce-fragment=\"1\"\u003e Arquivo de configuração ASCII\u003cbr data-mce-fragment=\"1\"\u003e SNMP v1\/v2\/v3\u003cbr data-mce-fragment=\"1\"\u003e RADIUS\u003cbr data-mce-fragment=\"1\"\u003e TACACS+\u003cbr data-mce-fragment=\"1\"\u003e Amplo suporte a MIB\u003cbr data-mce-fragment=\"1\"\u003e Recuperação e reversão de configuração do Junos OS\u003cbr data-mce-fragment=\"1\"\u003e Reversão de imagem\u003cbr data-mce-fragment=\"1\"\u003e Plug-in OpenStack Neutron\u003cbr data-mce-fragment=\"1\"\u003e Puppet\u003cbr data-mce-fragment=\"1\"\u003e Chef\u003cbr data-mce-fragment=\"1\"\u003e Python\u003cbr data-mce-fragment=\"1\"\u003e Junos OS event, commit e OP scripts\u003cbr data-mce-fragment=\"1\"\u003e RMON (RFC 2819): Grupos 1, 2, 3, 9\u003cbr data-mce-fragment=\"1\"\u003e Network Time Protocol (NTP)\u003cbr data-mce-fragment=\"1\"\u003e SSHv2\u003cbr data-mce-fragment=\"1\"\u003e Cópia segura\u003cbr data-mce-fragment=\"1\"\u003e Resolvedor DNS\u003cbr data-mce-fragment=\"1\"\u003e Registro do sistema\u003cbr data-mce-fragment=\"1\"\u003e Monitoramento ambiental\u003cbr data-mce-fragment=\"1\"\u003e Sensor de temperatura\u003cbr data-mce-fragment=\"1\"\u003e Backup de configuração via FTP\/cópia segura\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr data-mce-fragment=\"1\"\u003e\n\n\u003ctd data-mce-fragment=\"1\"\u003eSolução de problemas\u003c\/td\u003e\n\n\u003ctd width=\"394\" data-mce-fragment=\"1\"\u003eDepuração: CLI via console, telnet ou SSH\u003cbr data-mce-fragment=\"1\"\u003e Diagnóstico: Comandos Show, debug e statistics\u003cbr data-mce-fragment=\"1\"\u003e Espelhamento de porta\u003cbr data-mce-fragment=\"1\"\u003e Ferramentas IP: Extended ping e trace\u003cbr data-mce-fragment=\"1\"\u003e Commit e rollback da Juniper Networks\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr data-mce-fragment=\"1\"\u003e\n\n\u003ctd data-mce-fragment=\"1\"\u003eTemperatura de operação\u003c\/td\u003e\n\n\u003ctd data-mce-fragment=\"1\"\u003e0° a 40° C (32° a 104° F)\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr data-mce-fragment=\"1\"\u003e\n\n\u003ctd data-mce-fragment=\"1\"\u003eTemperatura de armazenamento\u003c\/td\u003e\n\n\u003ctd data-mce-fragment=\"1\"\u003e-40° a 70° C (-40° a 158° F)\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr data-mce-fragment=\"1\"\u003e\n\n\u003ctd data-mce-fragment=\"1\"\u003eAltitude de operação\u003c\/td\u003e\n\n\u003ctd data-mce-fragment=\"1\"\u003e Até 3.048 m (10.000 pés)\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr data-mce-fragment=\"1\"\u003e\n\n\u003ctd data-mce-fragment=\"1\"\u003eUmidade relativa de operação\u003c\/td\u003e\n\n\u003ctd data-mce-fragment=\"1\"\u003e 5 a 90% (sem condensação)\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr data-mce-fragment=\"1\"\u003e\n\n\u003ctd data-mce-fragment=\"1\"\u003eUmidade relativa fora de operação\u003c\/td\u003e\n\n\u003ctd data-mce-fragment=\"1\"\u003e 5 a 95% (sem condensação)\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr data-mce-fragment=\"1\"\u003e\n\n\u003ctd data-mce-fragment=\"1\"\u003eSísmico\u003c\/td\u003e\n\n\u003ctd width=\"394\" data-mce-fragment=\"1\"\u003e: Projetado para atender aos requisitos de terremoto GR-63, Zona 4\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr data-mce-fragment=\"1\"\u003e\n\n\u003ctd width=\"395\" data-mce-fragment=\"1\"\u003eSegurança\u003c\/td\u003e\n\n\u003ctd width=\"394\" data-mce-fragment=\"1\"\u003eCAN\/CSA-C22.2 No. 60950-1 Segurança de equipamentos\u003cbr data-mce-fragment=\"1\"\u003e de Tecnologia da Informação\u003cbr data-mce-fragment=\"1\"\u003e UL 60950-1 Segurança de equipamentos de Tecnologia da Informação\u003cbr data-mce-fragment=\"1\"\u003e EN 60950-1 Segurança de equipamentos de Tecnologia da Informação\u003cbr data-mce-fragment=\"1\"\u003e IEC 60950-1 Segurança de equipamentos de Tecnologia da Informação (Todas\u003cbr data-mce-fragment=\"1\"\u003e as variações por país)\u003cbr data-mce-fragment=\"1\"\u003e EN 60825-1 Segurança de Produtos Laser Parte 1: Classificação\u003cbr data-mce-fragment=\"1\"\u003e de Equipamentos\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr data-mce-fragment=\"1\"\u003e\n\n\u003ctd width=\"395\" data-mce-fragment=\"1\"\u003eCompatibilidade Eletromagnética\u003c\/td\u003e\n\n\u003ctd width=\"394\" data-mce-fragment=\"1\"\u003e47CFR Parte 15, (FCC) Classe A\u003cbr data-mce-fragment=\"1\"\u003e ICES-003 Classe A\u003cbr data-mce-fragment=\"1\"\u003e EN 55022 Classe A\u003cbr data-mce-fragment=\"1\"\u003e CISPR 22 Classe A\u003cbr data-mce-fragment=\"1\"\u003e EN 55024\u003cbr data-mce-fragment=\"1\"\u003e CISPR 24\u003cbr data-mce-fragment=\"1\"\u003e EN 300 386\u003cbr data-mce-fragment=\"1\"\u003e VCCI Classe A\u003cbr data-mce-fragment=\"1\"\u003e AS\/NZA CISPR22 Classe A\u003cbr data-mce-fragment=\"1\"\u003e KN22 Classe A\u003cbr data-mce-fragment=\"1\"\u003e CNS 13438 Classe A\u003cbr data-mce-fragment=\"1\"\u003e EN 61000-3-2\u003cbr data-mce-fragment=\"1\"\u003e EN 61000-3-3\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr data-mce-fragment=\"1\"\u003e\n\n\u003ctd width=\"395\" data-mce-fragment=\"1\"\u003eETSI\u003c\/td\u003e\n\n\u003ctd width=\"394\" data-mce-fragment=\"1\"\u003eETSI EN 300 019: Condições Ambientais e Testes\u003cbr data-mce-fragment=\"1\"\u003e Ambientais para Equipamentos de Telecomunicações\u003cbr data-mce-fragment=\"1\"\u003e ETSI EN 300 019-2-1 (2000) Armazenamento\u003cbr data-mce-fragment=\"1\"\u003e ETSI EN 300 019-2-2 (1999) Transporte\u003cbr data-mce-fragment=\"1\"\u003e ETSI EN 300 019-2-3 (2003) Uso Estacionário em Locais Protegidos contra Intempéries\u003cbr data-mce-fragment=\"1\"\u003e ETSI EN 300 019-2-4 (2003) Uso Estacionário em Locais Não Protegidos contra Intempéries\u003cbr data-mce-fragment=\"1\"\u003e ETS 300753 (1997) Ruído acústico emitido por\u003cbr data-mce-fragment=\"1\"\u003e equipamentos de telecomunicações\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\n\u003c\/tbody\u003e\n\n\n\u003c\/table\u003e\n[\/specifications]\u003cbr\u003e\u003cbr\u003e[accesories]\n\u003ctable width=\"434\" data-mce-fragment=\"1\"\u003e\n\n\u003ctbody data-mce-fragment=\"1\"\u003e\n\n\u003ctr data-mce-fragment=\"1\"\u003e\n\n\u003ctd colspan=\"2\" width=\"434\" data-mce-fragment=\"1\"\u003e Placas de linha\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr data-mce-fragment=\"1\"\u003e\n\n\u003ctd width=\"154\" data-mce-fragment=\"1\"\u003eQFX10000-36Q\u003c\/td\u003e\n\n\u003ctd width=\"280\" data-mce-fragment=\"1\"\u003ePlaca de linha QFX10000 de 36 portas 40GbE QSFP+ \/ 12 portas 100GbE QSFP28\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr data-mce-fragment=\"1\"\u003e\n\n\u003ctd width=\"154\" data-mce-fragment=\"1\"\u003eQFX10000-30C\u003c\/td\u003e\n\n\u003ctd width=\"280\" data-mce-fragment=\"1\"\u003ePlaca de linha QFX10000 de 30 portas 100GbE QSFP28\/40GbE QSFP+\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr data-mce-fragment=\"1\"\u003e\n\n\u003ctd width=\"154\" data-mce-fragment=\"1\"\u003eQFX10000-30C-M\u003c\/td\u003e\n\n\u003ctd width=\"280\" data-mce-fragment=\"1\"\u003ePlaca de linha QFX10000 de 30 portas 100GbE QSFP28\/40GbE QSFP+ MACsec\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr data-mce-fragment=\"1\"\u003e\n\n\u003ctd width=\"154\" data-mce-fragment=\"1\"\u003eQFX10000-60S-6Q\u003c\/td\u003e\n\n\u003ctd width=\"280\" data-mce-fragment=\"1\"\u003ePlaca de linha QFX10000 de 60 portas 1\/10GbE SFP\/SFP+ com 6 portas 40GbE QSFP+ \/ 2 portas 100GbE QSFP28\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr data-mce-fragment=\"1\"\u003e\n\n\u003ctd width=\"154\" data-mce-fragment=\"1\"\u003eQFX10K12C-DWDM\u003c\/td\u003e\n\n\u003ctd width=\"280\" data-mce-fragment=\"1\"\u003ePlaca de linha QFX10000 1,2 Tbps 6 portas 200GbE de taxa de linha DWDM Coerente MACsec\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr data-mce-fragment=\"1\"\u003e\n\n\u003ctd width=\"154\" data-mce-fragment=\"1\"\u003eJNP-QSFP-100G-SR4\u003c\/td\u003e\n\n\u003ctd width=\"280\" data-mce-fragment=\"1\"\u003eÓptica QSFP28 100GBASE-SR4 para transmissão de até 100 m sobre fibra multímodo paralela (MMF)\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr data-mce-fragment=\"1\"\u003e\n\n\u003ctd width=\"154\" data-mce-fragment=\"1\"\u003eJNP-QSFP-100G-LR4\u003c\/td\u003e\n\n\u003ctd width=\"280\" data-mce-fragment=\"1\"\u003eÓptica QSFP28 100GBASE-LR4 para transmissão de até 10 km sobre fibra monomodo serial (SMF)\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr data-mce-fragment=\"1\"\u003e\n\n\u003ctd width=\"154\" data-mce-fragment=\"1\"\u003eJNP-QSFP-100G-PSM4\u003c\/td\u003e\n\n\u003ctd width=\"280\" data-mce-fragment=\"1\"\u003eÓptica QSFP28 100GBASE-PSM4 para transmissão de até 2 km sobre SMF paralela\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr data-mce-fragment=\"1\"\u003e\n\n\u003ctd width=\"154\" data-mce-fragment=\"1\"\u003eJNP-QSFP-100G-CWDM\u003c\/td\u003e\n\n\u003ctd width=\"280\" data-mce-fragment=\"1\"\u003eÓptica QSFP28 100GBASE-CWDM4 para transmissão de até 2 km sobre SMF serial\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr data-mce-fragment=\"1\"\u003e\n\n\u003ctd width=\"154\" data-mce-fragment=\"1\"\u003eJNP-QSFP-40GE-IR4\u003c\/td\u003e\n\n\u003ctd width=\"280\" data-mce-fragment=\"1\"\u003eÓptica QSFP+ 40GBASE-IR4 40 Gigabit, 1.310 nm para transmissão de até 2 km em SMF\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr data-mce-fragment=\"1\"\u003e\n\n\u003ctd width=\"154\" data-mce-fragment=\"1\"\u003eJNP-QSFP-40G-LR4\u003c\/td\u003e\n\n\u003ctd width=\"280\" data-mce-fragment=\"1\"\u003eÓptica QSFP+ 40GBASE-LR4 40 Gigabit, 1.310 nm para transmissão de até 10 km em SMF\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr data-mce-fragment=\"1\"\u003e\n\n\u003ctd width=\"154\" data-mce-fragment=\"1\"\u003eJNP-QSFP-40G-LX4\u003c\/td\u003e\n\n\u003ctd width=\"280\" data-mce-fragment=\"1\"\u003eÓptica QSFP+ 40GBASE-LX4 40 Gigabit, 100 m (150 m) com fibra MMF duplex OM3 (OM4)\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr data-mce-fragment=\"1\"\u003e\n\n\u003ctd width=\"154\" data-mce-fragment=\"1\"\u003eJNP-QSFP-4X10GE-IR\u003c\/td\u003e\n\n\u003ctd width=\"280\" data-mce-fragment=\"1\"\u003eÓptica QSFP+ 40GBASE, transmissão de até 1,4 km em modo único paralelo (alcance longo de 4x10GbE até 1,4 km)\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr data-mce-fragment=\"1\"\u003e\n\n\u003ctd width=\"154\" data-mce-fragment=\"1\"\u003eJNP-QSFP-4X10GE-LR\u003c\/td\u003e\n\n\u003ctd width=\"280\" data-mce-fragment=\"1\"\u003eÓptica QSFP+ 40GBASE, transmissão de até 10 km em modo único paralelo (alcance longo de 4x10GbE até 10 km)\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr data-mce-fragment=\"1\"\u003e\n\n\u003ctd width=\"154\" data-mce-fragment=\"1\"\u003eQFX-QSFP-40G-ESR4\u003c\/td\u003e\n\n\u003ctd width=\"280\" data-mce-fragment=\"1\"\u003eÓptica QSFP+ 40GBASE-ESR4 40 Gigabit, 300 m (400 m) com MMF OM3 (OM4)\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr data-mce-fragment=\"1\"\u003e\n\n\u003ctd width=\"154\" data-mce-fragment=\"1\"\u003eQFX-QSFP-40G-SR4\u003c\/td\u003e\n\n\u003ctd width=\"280\" data-mce-fragment=\"1\"\u003eÓptica QSFP+ 40GBASE-SR4 40 Gigabit, 850 nm para transmissão de até 150 m em MMF\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr data-mce-fragment=\"1\"\u003e\n\n\u003ctd width=\"154\" data-mce-fragment=\"1\"\u003eQFX-SFP-10GE-LR\u003c\/td\u003e\n\n\u003ctd width=\"280\" data-mce-fragment=\"1\"\u003eÓptica SFP+ 10GBASE-LR 10 Gigabit Ethernet, 1.310 nm para transmissão de 10 km em SMF\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr data-mce-fragment=\"1\"\u003e\n\n\u003ctd width=\"154\" data-mce-fragment=\"1\"\u003eQFX-SFP-10GE-SR\u003c\/td\u003e\n\n\u003ctd width=\"280\" data-mce-fragment=\"1\"\u003eÓptica SFP+ 10GBASE-SR 10 Gigabit Ethernet, 850 nm para transmissão de até 300 m em MMF\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr data-mce-fragment=\"1\"\u003e\n\n\u003ctd colspan=\"2\" width=\"434\" data-mce-fragment=\"1\"\u003eLicenças de recursos de software\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr data-mce-fragment=\"1\"\u003e\n\n\u003ctd width=\"154\" data-mce-fragment=\"1\"\u003eQFX10008-PFL\u003c\/td\u003e\n\n\u003ctd width=\"280\" data-mce-fragment=\"1\"\u003eLicença de recursos premium QFX10008\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr data-mce-fragment=\"1\"\u003e\n\n\u003ctd width=\"154\" data-mce-fragment=\"1\"\u003eQFX10008-AFL\u003c\/td\u003e\n\n\u003ctd width=\"280\" data-mce-fragment=\"1\"\u003eLicença de recursos avançados QFX10008\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr data-mce-fragment=\"1\"\u003e\n\n\u003ctd width=\"154\" data-mce-fragment=\"1\"\u003eQFX10000-30C-LFIB\u003c\/td\u003e\n\n\u003ctd width=\"280\" data-mce-fragment=\"1\"\u003eLicença de 1 milhão de FIB para placas de linha QFX10000-30C e QFX10000-30C-M\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr data-mce-fragment=\"1\"\u003e\n\n\u003ctd width=\"154\" data-mce-fragment=\"1\"\u003eQFX10000-36Q-LFIB\u003c\/td\u003e\n\n\u003ctd width=\"280\" data-mce-fragment=\"1\"\u003eLicença de 1 milhão de FIB para placas de linha QFX10000-36Q e QFX10K-12CDWDM\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003c!--nl--\"\u003e\u003ctd width=\"154\" data-mce-fragment=\"1\"\u003eQFX10000-60S-LFIB\u003c\/td\u003e\n\u003ctd width=\"280\" data-mce-fragment=\"1\"\u003eLicença de 1 milhão de FIB para placa de linha QFX10000-60S-6Q\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr data-mce-fragment=\"1\"\u003e\n\n\u003ctd colspan=\"2\" width=\"434\" data-mce-fragment=\"1\"\u003eCabos de alimentação\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr data-mce-fragment=\"1\"\u003e\n\n\u003ctd width=\"154\" data-mce-fragment=\"1\"\u003eCBL-EX-PWR-C19-C20\u003c\/td\u003e\n\n\u003ctd width=\"280\" data-mce-fragment=\"1\"\u003eCabo de conexão CA - PDU C20 (16A\/250V, 2,5m)\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr data-mce-fragment=\"1\"\u003e\n\n\u003ctd width=\"154\" data-mce-fragment=\"1\"\u003eQFX-SFP-10GE-SR\u003c\/td\u003e\n\n\u003ctd width=\"280\" data-mce-fragment=\"1\"\u003eÓptica SFP+ 10GBASE-SR 10 Gigabit Ethernet, 850 nm para transmissão de até 300 m em MMF\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr data-mce-fragment=\"1\"\u003e\n\n\u003ctd width=\"154\" data-mce-fragment=\"1\"\u003eQFX-SFP-10GE-USR\u003c\/td\u003e\n\n\u003ctd width=\"280\" data-mce-fragment=\"1\"\u003eÓptica SFP+ 10 Gigabit Ethernet de alcance ultracurto, 850 nm para 10 m em OM1, 20 m em OM2, 100 m em fibra multímodo OM3\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr data-mce-fragment=\"1\"\u003e\n\n\u003ctd width=\"154\" data-mce-fragment=\"1\"\u003eQFX-SFP-1GE-LX\u003c\/td\u003e\n\n\u003ctd width=\"280\" data-mce-fragment=\"1\"\u003eÓptica SFP 1000BASE-LX Gigabit-Ethernet, 1.310 nm para transmissão de 10 km em SMF\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr data-mce-fragment=\"1\"\u003e\n\n\u003ctd width=\"154\" data-mce-fragment=\"1\"\u003eQFX-SFP-1GE-SX\u003c\/td\u003e\n\n\u003ctd width=\"280\" data-mce-fragment=\"1\"\u003eÓptica SFP 1000BASE-SX Gigabit-Ethernet, 850 nm para transmissão de até 550 m em MMF\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr data-mce-fragment=\"1\"\u003e\n\n\u003ctd width=\"154\" data-mce-fragment=\"1\"\u003eQFX-SFP-1GE-T\u003c\/td\u003e\n\n\u003ctd width=\"280\" data-mce-fragment=\"1\"\u003eMódulo transceptor de cobre SFP 1000BASE-T para transmissão de até 100 m em Cat5\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\n\u003c\/tbody\u003e\n\n\n\u003c\/table\u003e\n[\/accesories] \u003cspan\u003eA linha QFX10000 de switches Ethernet de backbone e núcleo de data center modulares oferece escala, flexibilidade e abertura líderes do setor, com um design que permite a transição perfeita de velocidades de interface de 10GbE e 40GbE para 100GbE. Esses switches de alto desempenho e visão de futuro são projetados para ajudar os operadores de nuvem e data centers a extrair o máximo valor e inteligência de sua infraestrutura de rede no futuro.\u003c\/span\u003e","brand":"Juniper","offers":[{"title":"Default Title","offer_id":48958328144128,"sku":"QFX10008-REDUND-H-NEW","price":160204.97,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0388\/5331\/2557\/files\/QFX10008.jpg?v=1783446416","url":"https:\/\/alotechparts.com\/pt-br\/products\/juniper-qfx10008-redund-h-chassis","provider":"Alo Tech Solutions","version":"1.0","type":"link"}