{"product_id":"juniper-ex9208-red3b-ac-chassis","title":"Chassi Juniper EX9208-RED3B-AC","description":"\u003cdiv class=\"short-hide\"\u003e[shortdesc]\n\u003cul\u003e\n\n\u003cli\u003eConfiguração redundante do sistema EX9208\u003c\/li\u003e\n\n\u003cli\u003eChassi de 8 slots com midplane passivo\u003c\/li\u003e\n\n\u003cli\u003e2 x motores de roteamento EX9200-RE2\u003c\/li\u003e\n\n\u003cli\u003e2 x módulos de malha de comutação EX9200-SF2\u003c\/li\u003e\n\n\u003cli\u003e4 x fontes de alimentação AC de 2520 W\u003c\/li\u003e\n\n\u003cli\u003e1 x bandeja de ventilador\u003c\/li\u003e\n\n\u003cli\u003ePainéis em branco para slots de cartão de linha e slots de fonte de alimentação vazios\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n[\/shortdesc]\u003c\/div\u003e\n[properties]\n\u003ctable width=\"560\" data-mce-fragment=\"1\"\u003e\n\n\u003ctbody data-mce-fragment=\"1\"\u003e\n\n\u003ctr data-mce-fragment=\"1\"\u003e\n\n\u003ctd width=\"218\" data-mce-fragment=\"1\"\u003ePropriedades\u003c\/td\u003e\n\n\u003ctd width=\"342\" data-mce-fragment=\"1\"\u003eJuniper EX9208-RED3B-AC\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr data-mce-fragment=\"1\"\u003e\n\n\u003ctd width=\"218\" data-mce-fragment=\"1\"\u003eDescrição\u003c\/td\u003e\n\n\u003ctd width=\"342\" data-mce-fragment=\"1\"\u003eConfiguração de sistema redundante EX9208: chassi de 8 slots com midplane passivo, 2 motores de roteamento EX9200-RE2, 2 módulos de tecido de comutação EX9200-SF2, 1 bandeja de ventilador, 4 fontes de alimentação CA de 2520 W e todos os painéis em branco necessários\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr data-mce-fragment=\"1\"\u003e\n\n\u003ctd width=\"218\" data-mce-fragment=\"1\"\u003eFamília do produto\u003c\/td\u003e\n\n\u003ctd data-mce-fragment=\"1\"\u003eSérie EX9200\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr data-mce-fragment=\"1\"\u003e\n\n\u003ctd width=\"218\" data-mce-fragment=\"1\"\u003eTipo de produto\u003c\/td\u003e\n\n\u003ctd data-mce-fragment=\"1\"\u003eChassi de switch Ethernet\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr data-mce-fragment=\"1\"\u003e\n\n\u003ctd width=\"218\" data-mce-fragment=\"1\"\u003eNúmero total de slots\u003c\/td\u003e\n\n\u003ctd data-mce-fragment=\"1\"\u003e8\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr data-mce-fragment=\"1\"\u003e\n\n\u003ctd width=\"218\" data-mce-fragment=\"1\"\u003eSlots disponíveis para placas de linha\u003c\/td\u003e\n\n\u003ctd data-mce-fragment=\"1\"\u003e6\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr data-mce-fragment=\"1\"\u003e\n\n\u003ctd width=\"218\" data-mce-fragment=\"1\"\u003eMecanismo de roteamento\u003c\/td\u003e\n\n\u003ctd data-mce-fragment=\"1\"\u003e2x EX9200-RE2\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr data-mce-fragment=\"1\"\u003e\n\n\u003ctd width=\"218\" data-mce-fragment=\"1\"\u003eMódulo de estrutura de switch\u003c\/td\u003e\n\n\u003ctd data-mce-fragment=\"1\"\u003e2x EX9200-SF2\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr data-mce-fragment=\"1\"\u003e\n\n\u003ctd width=\"560\" colspan=\"2\" data-mce-fragment=\"1\"\u003eDensidade máxima de porta GbE (velocidade de cabo)\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr data-mce-fragment=\"1\"\u003e\n\n\u003ctd width=\"218\" data-mce-fragment=\"1\"\u003e1GbE\u003c\/td\u003e\n\n\u003ctd data-mce-fragment=\"1\"\u003e240\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr data-mce-fragment=\"1\"\u003e\n\n\u003ctd width=\"218\" data-mce-fragment=\"1\"\u003e10GbE\u003c\/td\u003e\n\n\u003ctd data-mce-fragment=\"1\"\u003e288 (240)\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr data-mce-fragment=\"1\"\u003e\n\n\u003ctd data-mce-fragment=\"1\"\u003e25GbE\u003c\/td\u003e\n\n\u003ctd data-mce-fragment=\"1\"\u003e360\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr data-mce-fragment=\"1\"\u003e\n\n\u003ctd width=\"218\" data-mce-fragment=\"1\"\u003e40GbE\u003c\/td\u003e\n\n\u003ctd data-mce-fragment=\"1\"\u003e90\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr data-mce-fragment=\"1\"\u003e\n\n\u003ctd width=\"218\" data-mce-fragment=\"1\"\u003e100GbE\u003c\/td\u003e\n\n\u003ctd data-mce-fragment=\"1\"\u003e90\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr data-mce-fragment=\"1\"\u003e\n\n\u003ctd width=\"218\" data-mce-fragment=\"1\"\u003eTecido\u003c\/td\u003e\n\n\u003ctd width=\"342\" data-mce-fragment=\"1\"\u003e• Capacidade de backplane de até 7,5 Tbps\u003cbr data-mce-fragment=\"1\"\u003e • Capacidade de tecido de até 1,5 Tbps (full duplex) por slot\u003cbr data-mce-fragment=\"1\"\u003e • Redundância de tecido 1+1\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr data-mce-fragment=\"1\"\u003e\n\n\u003ctd width=\"218\" data-mce-fragment=\"1\"\u003eMecanismo de roteamento\u003c\/td\u003e\n\n\u003ctd width=\"342\" data-mce-fragment=\"1\"\u003e• Mecanismos de roteamento mestre e de backup (redundância 1+1)\u003cbr data-mce-fragment=\"1\"\u003e • Até 64 GB DRAM\u003cbr data-mce-fragment=\"1\"\u003e • SSDs duplos plugáveis na frente (até 64 GB cada)\u003cbr data-mce-fragment=\"1\"\u003e • Portas de console, serial auxiliar e gerenciamento Ethernet\u003cbr data-mce-fragment=\"1\"\u003e • Interface de armazenamento USB\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr data-mce-fragment=\"1\"\u003e\n\n\u003ctd width=\"218\" data-mce-fragment=\"1\"\u003eSistema operacional\u003c\/td\u003e\n\n\u003ctd width=\"342\" data-mce-fragment=\"1\"\u003eSistema operacional Juniper Networks Junos\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr data-mce-fragment=\"1\"\u003e\n\n\u003ctd width=\"218\" data-mce-fragment=\"1\"\u003ePoder\u003c\/td\u003e\n\n\u003ctd width=\"342\" data-mce-fragment=\"1\"\u003eComporta até quatro fontes de alimentação:\u003cbr data-mce-fragment=\"1\"\u003e • 100-120 V AC (redundância 3+1)\u003cbr data-mce-fragment=\"1\"\u003e • 200-240 V AC (redundância 2+2)\u003cbr data-mce-fragment=\"1\"\u003e Consumo máximo de energia: 4.831 W (AC)\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr data-mce-fragment=\"1\"\u003e\n\n\u003ctd width=\"218\" data-mce-fragment=\"1\"\u003eResfriamento\u003c\/td\u003e\n\n\u003ctd width=\"342\" data-mce-fragment=\"1\"\u003e• Fluxo de ar da frente para trás\u003cbr data-mce-fragment=\"1\"\u003e • Bandeja de ventilador hot-swappable com redundância 1+1\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr data-mce-fragment=\"1\"\u003e\n\n\u003ctd width=\"218\" data-mce-fragment=\"1\"\u003eDimensões (L x A x P)\u003c\/td\u003e\n\n\u003ctd width=\"342\" data-mce-fragment=\"1\"\u003e17,5 x 14,0 x 27,75 pol\u003cbr data-mce-fragment=\"1\"\u003e (44,5 x 35,6 x 70,5 cm)\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr data-mce-fragment=\"1\"\u003e\n\n\u003ctd width=\"218\" data-mce-fragment=\"1\"\u003ePeso (totalmente carregado)\u003c\/td\u003e\n\n\u003ctd width=\"342\" data-mce-fragment=\"1\"\u003e163,6 lbs (74,2 kg)\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr data-mce-fragment=\"1\"\u003e\n\n\u003ctd width=\"218\" data-mce-fragment=\"1\"\u003eUnidades de rack\u003c\/td\u003e\n\n\u003ctd data-mce-fragment=\"1\"\u003e8 U\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr data-mce-fragment=\"1\"\u003e\n\n\u003ctd colspan=\"2\" data-mce-fragment=\"1\"\u003eConsumo de energia\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr data-mce-fragment=\"1\"\u003e\n\n\u003ctd width=\"218\" data-mce-fragment=\"1\"\u003ePotência Típica Redundante do EX9208\u003c\/td\u003e\n\n\u003ctd data-mce-fragment=\"1\"\u003e800 W\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr data-mce-fragment=\"1\"\u003e\n\n\u003ctd width=\"218\" data-mce-fragment=\"1\"\u003ePotência Reservada Redundante do EX9208\u003c\/td\u003e\n\n\u003ctd data-mce-fragment=\"1\"\u003e800 W\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr data-mce-fragment=\"1\"\u003e\n\n\u003ctd width=\"218\" data-mce-fragment=\"1\"\u003eUnidades Adicionais\u003c\/td\u003e\n\n\u003ctd width=\"342\" data-mce-fragment=\"1\"\u003ePotência Típica\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr data-mce-fragment=\"1\"\u003e\n\n\u003ctd width=\"218\" data-mce-fragment=\"1\"\u003eMecanismo de roteamento EX9200\u003c\/td\u003e\n\n\u003ctd data-mce-fragment=\"1\"\u003e90 W\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr data-mce-fragment=\"1\"\u003e\n\n\u003ctd width=\"218\" data-mce-fragment=\"1\"\u003eEstrutura de comutação EX9200-2\u003c\/td\u003e\n\n\u003ctd data-mce-fragment=\"1\"\u003e155 W\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr data-mce-fragment=\"1\"\u003e\n\n\u003ctd width=\"218\" data-mce-fragment=\"1\"\u003eUnidades Adicionais\u003c\/td\u003e\n\n\u003ctd width=\"342\" data-mce-fragment=\"1\"\u003ePotência Máxima\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr data-mce-fragment=\"1\"\u003e\n\n\u003ctd width=\"218\" data-mce-fragment=\"1\"\u003eMecanismo de roteamento EX9200\u003c\/td\u003e\n\n\u003ctd data-mce-fragment=\"1\"\u003e90 W\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr data-mce-fragment=\"1\"\u003e\n\n\u003ctd width=\"218\" data-mce-fragment=\"1\"\u003eEstrutura de comutação EX9200-2\u003c\/td\u003e\n\n\u003ctd data-mce-fragment=\"1\"\u003e155 W\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr data-mce-fragment=\"1\"\u003e\n\n\u003ctd colspan=\"2\" width=\"560\" data-mce-fragment=\"1\"\u003eCapacidade da fonte de alimentação\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr data-mce-fragment=\"1\"\u003e\n\n\u003ctd width=\"218\" data-mce-fragment=\"1\"\u003eEntrada CA de 100-120V\u003c\/td\u003e\n\n\u003ctd width=\"342\" data-mce-fragment=\"1\"\u003e3.501 W\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr data-mce-fragment=\"1\"\u003e\n\n\u003ctd width=\"218\" data-mce-fragment=\"1\"\u003eEntrada CA de 200-240 V\u003c\/td\u003e\n\n\u003ctd width=\"342\" data-mce-fragment=\"1\"\u003e4.100 W\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr data-mce-fragment=\"1\"\u003e\n\n\u003ctd width=\"218\" data-mce-fragment=\"1\"\u003eEntrada CC de -40 a -72 V\u003c\/td\u003e\n\n\u003ctd width=\"342\" data-mce-fragment=\"1\"\u003e4.100 W\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr data-mce-fragment=\"1\"\u003e\n\n\u003ctd colspan=\"2\" width=\"560\" data-mce-fragment=\"1\"\u003eNúmero máximo de placas de linha em um chassi\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr data-mce-fragment=\"1\"\u003e\n\n\u003ctd width=\"218\" data-mce-fragment=\"1\"\u003eEX9200-40XS\u003c\/td\u003e\n\n\u003ctd width=\"342\" data-mce-fragment=\"1\"\u003e6\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr data-mce-fragment=\"1\"\u003e\n\n\u003ctd width=\"218\" data-mce-fragment=\"1\"\u003eEX9200-15C\u003c\/td\u003e\n\n\u003ctd width=\"342\" data-mce-fragment=\"1\"\u003e6\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr data-mce-fragment=\"1\"\u003e\n\n\u003ctd width=\"218\" data-mce-fragment=\"1\"\u003eEX9200-12QS\u003c\/td\u003e\n\n\u003ctd width=\"342\" data-mce-fragment=\"1\"\u003e6\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr data-mce-fragment=\"1\"\u003e\n\n\u003ctd width=\"218\" data-mce-fragment=\"1\"\u003eEX9200-32XS\u003c\/td\u003e\n\n\u003ctd width=\"342\" data-mce-fragment=\"1\"\u003e4\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr data-mce-fragment=\"1\"\u003e\n\n\u003ctd width=\"218\" data-mce-fragment=\"1\"\u003eEX9200-6QS\u003c\/td\u003e\n\n\u003ctd width=\"342\" data-mce-fragment=\"1\"\u003e4\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr data-mce-fragment=\"1\"\u003e\n\n\u003ctd width=\"218\" data-mce-fragment=\"1\"\u003eEX9200-2C-8XS\u003c\/td\u003e\n\n\u003ctd width=\"342\" data-mce-fragment=\"1\"\u003e6\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr data-mce-fragment=\"1\"\u003e\n\n\u003ctd width=\"218\" data-mce-fragment=\"1\"\u003eEX9200-40T\u003c\/td\u003e\n\n\u003ctd width=\"342\" data-mce-fragment=\"1\"\u003e6\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr data-mce-fragment=\"1\"\u003e\n\n\u003ctd width=\"218\" data-mce-fragment=\"1\"\u003eEX9200-40F\u003c\/td\u003e\n\n\u003ctd width=\"342\" data-mce-fragment=\"1\"\u003e6\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr data-mce-fragment=\"1\"\u003e\n\n\u003ctd width=\"218\" data-mce-fragment=\"1\"\u003eEX9200-MPC\u003c\/td\u003e\n\n\u003ctd width=\"342\" data-mce-fragment=\"1\"\u003e6\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\n\u003c\/tbody\u003e\n\n\n\u003c\/table\u003e\n[\/properties]\u003cbr\u003e\u003cbr\u003e[specifications]\n\u003ctable width=\"636\" data-mce-fragment=\"1\"\u003e\n\n\u003ctbody data-mce-fragment=\"1\"\u003e\n\n\u003ctr data-mce-fragment=\"1\"\u003e\n\n\u003ctd width=\"257\" data-mce-fragment=\"1\"\u003eEspecificações\u003c\/td\u003e\n\n\u003ctd width=\"379\" data-mce-fragment=\"1\"\u003eEX9208-RED3B-AC\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr data-mce-fragment=\"1\"\u003e\n\n\u003ctd width=\"257\" data-mce-fragment=\"1\"\u003eCapacidade do backplane\u003c\/td\u003e\n\n\u003ctd width=\"379\" data-mce-fragment=\"1\"\u003eAté 7,5 Tbps\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr data-mce-fragment=\"1\"\u003e\n\n\u003ctd width=\"257\" data-mce-fragment=\"1\"\u003eLargura de banda máxima do tecido\/slot\u003c\/td\u003e\n\n\u003ctd width=\"379\" data-mce-fragment=\"1\"\u003e1,5 Tbps\/slot\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr data-mce-fragment=\"1\"\u003e\n\n\u003ctd width=\"257\" data-mce-fragment=\"1\"\u003eTaxa de transferência de tecido de comutação por slot\u003c\/td\u003e\n\n\u003ctd width=\"379\" data-mce-fragment=\"1\"\u003e480 Gbps (EX9200-SF2)\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr data-mce-fragment=\"1\"\u003e\n\n\u003ctd data-mce-fragment=\"1\"\u003eDRAM de RE\u003c\/td\u003e\n\n\u003ctd data-mce-fragment=\"1\"\u003e64 GB\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr data-mce-fragment=\"1\"\u003e\n\n\u003ctd data-mce-fragment=\"1\"\u003eCPU de RE\u003c\/td\u003e\n\n\u003ctd data-mce-fragment=\"1\"\u003e2 GHz, seis núcleos\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr data-mce-fragment=\"1\"\u003e\n\n\u003ctd data-mce-fragment=\"1\"\u003eArmazenamento de RE\u003c\/td\u003e\n\n\u003ctd data-mce-fragment=\"1\"\u003e64 GB\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr data-mce-fragment=\"1\"\u003e\n\n\u003ctd width=\"636\" colspan=\"2\" data-mce-fragment=\"1\"\u003eRecursos de software\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr data-mce-fragment=\"1\"\u003e\n\n\u003ctd width=\"257\" data-mce-fragment=\"1\"\u003eAlta disponibilidade\u003c\/td\u003e\n\n\u003ctd width=\"379\" data-mce-fragment=\"1\"\u003eHardware projetado para operação contínua:\u003cbr data-mce-fragment=\"1\"\u003e • Arquitetura segura e modular que isola falhas\u003cbr data-mce-fragment=\"1\"\u003e • Planos de controle e encaminhamento separados que aprimoram a escalabilidade e a resiliência\u003cbr data-mce-fragment=\"1\"\u003e • Failover transparente e recuperação de rede\u003cbr data-mce-fragment=\"1\"\u003e • Comutação de Mecanismo de Roteamento Gracioso (GRES)\u003cbr data-mce-fragment=\"1\"\u003e • Roteamento ativo ininterrupto (NSR)\u003cbr data-mce-fragment=\"1\"\u003e • Bridging ininterrupto (NSB)\u003cbr data-mce-fragment=\"1\"\u003e • Atualização de software em serviço unificada (ISSU unificada)*\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr data-mce-fragment=\"1\"\u003e\n\n\u003ctd width=\"257\" data-mce-fragment=\"1\"\u003eRecursos da Camada 2\u003c\/td\u003e\n\n\u003ctd width=\"379\" data-mce-fragment=\"1\"\u003eAté 1 milhão de endereços de controle de acesso à mídia (MAC)\u003cbr data-mce-fragment=\"1\"\u003e Até 512.000 entradas do Protocolo de Resolução de Endereços (ARP) com licença ML (256.000 entradas sem licença ML)\u003cbr data-mce-fragment=\"1\"\u003e Até 512.000 entradas do Bloco de Informações de Encaminhamento (FIB) com licença ML (256.000 entradas sem licença ML)\u003cbr data-mce-fragment=\"1\"\u003e Quadros jumbo (máximo de 9.192 bytes)\u003cbr data-mce-fragment=\"1\"\u003e 32.000 VLANs\u003cbr data-mce-fragment=\"1\"\u003e Protocolo de Registro de VLAN\u003cbr data-mce-fragment=\"1\"\u003e 3ad – Protocolo de Controle de Agregação de Link (LACP)\u003cbr data-mce-fragment=\"1\"\u003e 1D – Protocolo de Spanning Tree (STP)\u003cbr data-mce-fragment=\"1\"\u003e 1w – Protocolo de Spanning Tree Rápido (RSTP)\u003cbr data-mce-fragment=\"1\"\u003e 1s – Protocolo de Múltiplas Spanning Tree (MSTP)\u003cbr data-mce-fragment=\"1\"\u003e Protocolo de Spanning Tree de VLAN (VSTP)\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr data-mce-fragment=\"1\"\u003e\n\n\u003ctd width=\"257\" data-mce-fragment=\"1\"\u003eRecursos da Camada 3\u003c\/td\u003e\n\n\u003ctd width=\"379\" data-mce-fragment=\"1\"\u003e1 milhão de bases de informações de roteamento IPv4 (RIB)\u003cbr data-mce-fragment=\"1\"\u003e 1 milhão de bases de informações de roteamento IPv6 (RIB)\u003cbr data-mce-fragment=\"1\"\u003e Roteamento estático\u003cbr data-mce-fragment=\"1\"\u003e RIP v1\/v2\u003cbr data-mce-fragment=\"1\"\u003e OSPF v1\/v2\u003cbr data-mce-fragment=\"1\"\u003e OSPF v3\u003cbr data-mce-fragment=\"1\"\u003e Encaminhamento baseado em filtro\u003cbr data-mce-fragment=\"1\"\u003e Protocolo de Redundância de Roteador Virtual (VRRP)*\u003cbr data-mce-fragment=\"1\"\u003e IPv6\u003cbr data-mce-fragment=\"1\"\u003e Detecção de Encaminhamento Bidirecional (BFD)\u003cbr data-mce-fragment=\"1\"\u003e Roteadores virtuais\u003cbr data-mce-fragment=\"1\"\u003e BGP (licença de recurso avançado)\u003cbr data-mce-fragment=\"1\"\u003e IS-IS (licença de recurso avançado)\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr data-mce-fragment=\"1\"\u003e\n\n\u003ctd width=\"257\" data-mce-fragment=\"1\"\u003eTunelamento de hardware\u003c\/td\u003e\n\n\u003ctd width=\"379\" data-mce-fragment=\"1\"\u003eTúneis GRE\u003cbr data-mce-fragment=\"1\"\u003e Capacidades MPLS (Licença de Recurso Avançado)\u003cbr data-mce-fragment=\"1\"\u003e VPLS\u003cbr data-mce-fragment=\"1\"\u003e VPNs BGP\/MPLS\u003cbr data-mce-fragment=\"1\"\u003e VPNs Ethernet\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr data-mce-fragment=\"1\"\u003e\n\n\u003ctd width=\"257\" data-mce-fragment=\"1\"\u003eMulticast\u003c\/td\u003e\n\n\u003ctd width=\"379\" data-mce-fragment=\"1\"\u003eAté 256.000 rotas multicast IPv4\u003cbr data-mce-fragment=\"1\"\u003e Até 256.000 rotas multicast IPv6\u003cbr data-mce-fragment=\"1\"\u003e Protocolo de Gerenciamento de Grupo de Internet (IGMP) v1\/v2\/v3\u003cbr data-mce-fragment=\"1\"\u003e Snooping IGMP\u003cbr data-mce-fragment=\"1\"\u003e Snooping MLD\u003cbr data-mce-fragment=\"1\"\u003e Multicast Independente de Protocolo PIM-SM, PIM-SSM, PIM-DM\u003cbr data-mce-fragment=\"1\"\u003e Protocolo de Descoberta de Fonte Multicast (MSDP)\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr data-mce-fragment=\"1\"\u003e\n\n\u003ctd width=\"257\" data-mce-fragment=\"1\"\u003eFiltros de firewall\u003c\/td\u003e\n\n\u003ctd width=\"379\" data-mce-fragment=\"1\"\u003eACLs de porta\u003cbr data-mce-fragment=\"1\"\u003e ACLs de VLAN\u003cbr data-mce-fragment=\"1\"\u003e ACLs de roteador\u003cbr data-mce-fragment=\"1\"\u003e Proteção de negação de serviço (DoS) do plano de controle\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr data-mce-fragment=\"1\"\u003e\n\n\u003ctd width=\"257\" data-mce-fragment=\"1\"\u003eQualidade de serviço (QoS)\u003c\/td\u003e\n\n\u003ctd width=\"379\" data-mce-fragment=\"1\"\u003e16.000 policiadores por chassi\u003cbr data-mce-fragment=\"1\"\u003e 8 filas de saída por porta\u003cbr data-mce-fragment=\"1\"\u003e Agendamento de detecção precoce aleatória ponderada (WRED)\u003cbr data-mce-fragment=\"1\"\u003e Enfileiramento round-robin ponderado (WRR)\u003cbr data-mce-fragment=\"1\"\u003e Enfileiramento de prioridade estrita\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr data-mce-fragment=\"1\"\u003e\n\n\u003ctd width=\"257\" data-mce-fragment=\"1\"\u003eVirtualização\u003c\/td\u003e\n\n\u003ctd width=\"379\" data-mce-fragment=\"1\"\u003eIntegração com Juniper Networks Contrail\u003cbr data-mce-fragment=\"1\"\u003e Integração com controladores VMware NSX SDN\u003cbr data-mce-fragment=\"1\"\u003e Protocolos de virtualização de rede como Virtual eXtensible LAN (VXLAN) e Open vSwitch Database (OVSDB)\u003cbr data-mce-fragment=\"1\"\u003e Gateway VXLAN Camada 2 e Camada 3\u003cbr data-mce-fragment=\"1\"\u003e EVPN\u003cbr data-mce-fragment=\"1\"\u003e Multihoming EVPN (Interface de Comutação EVPN – Agregação de Link)\u003cbr data-mce-fragment=\"1\"\u003e Gateway L2 e L3 EVPN VXLAN\u003cbr data-mce-fragment=\"1\"\u003e Serviço de LAN Privada Virtual (VPLS) para Interconexão de Data Center\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr data-mce-fragment=\"1\"\u003e\n\n\u003ctd width=\"257\" data-mce-fragment=\"1\"\u003eGerenciamento\u003c\/td\u003e\n\n\u003ctd width=\"379\" data-mce-fragment=\"1\"\u003eInterface de linha de comando (CLI) do Junos OS\u003cbr data-mce-fragment=\"1\"\u003e Protocolo de gerenciamento XML do Junos\u003cbr data-mce-fragment=\"1\"\u003e SNMP v1\/v2\/v3\u003cbr data-mce-fragment=\"1\"\u003e RADIUS\u003cbr data-mce-fragment=\"1\"\u003e TACACS+\u003cbr data-mce-fragment=\"1\"\u003e Suporte MIB extenso\u003cbr data-mce-fragment=\"1\"\u003e Espelhamento de porta baseado em firewall\u003cbr data-mce-fragment=\"1\"\u003e Protocolo de Descoberta da Camada de Link (LLDP)\u003cbr data-mce-fragment=\"1\"\u003e Soluções de Insight Avançado (AIS)\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr data-mce-fragment=\"1\"\u003e\n\n\u003ctd data-mce-fragment=\"1\"\u003eTemperatura de operação\u003c\/td\u003e\n\n\u003ctd data-mce-fragment=\"1\"\u003e0° a 40° C (32° a 104° F)\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr data-mce-fragment=\"1\"\u003e\n\n\u003ctd data-mce-fragment=\"1\"\u003eTemperatura de armazenamento\u003c\/td\u003e\n\n\u003ctd data-mce-fragment=\"1\"\u003e-40° a 70° C (-40° a 158° F)\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr data-mce-fragment=\"1\"\u003e\n\n\u003ctd data-mce-fragment=\"1\"\u003eAltitude de operação\u003c\/td\u003e\n\n\u003ctd data-mce-fragment=\"1\"\u003eAté 3.048 m (10.000 pés)\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr data-mce-fragment=\"1\"\u003e\n\n\u003ctd data-mce-fragment=\"1\"\u003eSísmico\u003c\/td\u003e\n\n\u003ctd data-mce-fragment=\"1\"\u003eProjetado para atender aos requisitos sísmicos GR-63, Zona 4\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr data-mce-fragment=\"1\"\u003e\n\n\u003ctd data-mce-fragment=\"1\"\u003eUmidade relativa de operação\u003c\/td\u003e\n\n\u003ctd data-mce-fragment=\"1\"\u003e5% a 90% (sem condensação)\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr data-mce-fragment=\"1\"\u003e\n\n\u003ctd data-mce-fragment=\"1\"\u003eUmidade relativa não operacional\u003c\/td\u003e\n\n\u003ctd data-mce-fragment=\"1\"\u003e5 a 95% (sem condensação)\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr data-mce-fragment=\"1\"\u003e\n\n\u003ctd width=\"257\" data-mce-fragment=\"1\"\u003eConformidade IEEE\u003c\/td\u003e\n\n\u003ctd width=\"379\" data-mce-fragment=\"1\"\u003eIEEE 802.1AB: Protocolo de Descoberta de Camada de Link (LLDP)\u003cbr data-mce-fragment=\"1\"\u003e IEEE 802.1D-2004: Protocolo de Spanning Tree (STP)\u003cbr data-mce-fragment=\"1\"\u003e IEEE 802.1p: Priorização de Classe de Serviço (CoS)\u003cbr data-mce-fragment=\"1\"\u003e IEEE 802.1Q: Redes Locais em Ponte Virtual\u003cbr data-mce-fragment=\"1\"\u003e IEEE 802.1s: Protocolo de Múltiplas Spanning Tree (MSTP)\u003cbr data-mce-fragment=\"1\"\u003e IEEE 802.1w: Protocolo de Spanning Tree Rápido (RSTP)\u003cbr data-mce-fragment=\"1\"\u003e IEEE 802.3: 10BASE-T\u003cbr data-mce-fragment=\"1\"\u003e IEEE 802.3u: 100BASE-T\u003cbr data-mce-fragment=\"1\"\u003e IEEE 802.3ab: 1000BASE-T\u003cbr data-mce-fragment=\"1\"\u003e IEEE 802.3z: 1000BASE-X\u003cbr data-mce-fragment=\"1\"\u003e IEEE 802.3ae: 10-Gigabit Ethernet\u003cbr data-mce-fragment=\"1\"\u003e IEEE 802.3ba: 40-Gigabit\/100-Gigabit Ethernet\u003cbr data-mce-fragment=\"1\"\u003e IEEE 802.3ah: Operação, Administração e Manutenção (OAM)\u003cbr data-mce-fragment=\"1\"\u003e IEEE 802.3ad: Protocolo de Controle de Agregação de Link (LACP)\u003cbr data-mce-fragment=\"1\"\u003e IEEE 802.1ae: Segurança de Controle de Acesso à Mídia\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr data-mce-fragment=\"1\"\u003e\n\n\u003ctd width=\"257\" data-mce-fragment=\"1\"\u003eConformidade RFC\u003c\/td\u003e\n\n\u003ctd width=\"379\" data-mce-fragment=\"1\"\u003eRFC 768: UDP\u003cbr data-mce-fragment=\"1\"\u003e RFC 783: Protocolo Trivial de Transferência de Arquivos (TFTP)\u003cbr data-mce-fragment=\"1\"\u003e RFC 791: IP\u003cbr data-mce-fragment=\"1\"\u003e RFC 792: Protocolo de Mensagens de Controle da Internet (ICMP)\u003cbr data-mce-fragment=\"1\"\u003e RFC 793: TCP\u003cbr data-mce-fragment=\"1\"\u003e RFC 826: ARP\u003cbr data-mce-fragment=\"1\"\u003e RFC 854: Cliente e servidor Telnet\u003cbr data-mce-fragment=\"1\"\u003e RFC 894: IP sobre Ethernet\u003cbr data-mce-fragment=\"1\"\u003e RFC 903: Protocolo de Resolução de Endereço Inverso (RARP)\u003cbr data-mce-fragment=\"1\"\u003e RFC 906: Bootstrap TFTP\u003cbr data-mce-fragment=\"1\"\u003e RFC 951, 1542: BootP\u003cbr data-mce-fragment=\"1\"\u003e RFC 1027: Proxy ARP\u003cbr data-mce-fragment=\"1\"\u003e RFC 1058: RIP v1\u003cbr data-mce-fragment=\"1\"\u003e RFC 1112: IGMP v1\u003cbr data-mce-fragment=\"1\"\u003e RFC 1122: Requisitos de Host\u003cbr data-mce-fragment=\"1\"\u003e RFC 1195: Uso de Interconexão de Sistemas Abertos (OSI) IS-IS para Roteamento em TCP\/IP e Ambientes Duplos (somente transporte TCP\/IP)\u003cbr data-mce-fragment=\"1\"\u003e RFC 1256: Protocolo de Descoberta de Roteador ICMP IPv4 (IRDP)\u003cbr data-mce-fragment=\"1\"\u003e RFC 1492: TACACS+\u003cbr data-mce-fragment=\"1\"\u003e RFC 1519: Roteamento Interdomínio Sem Classe (CIDR)\u003cbr data-mce-fragment=\"1\"\u003e RFC 1587: Opção OSPF NSSA\u003cbr data-mce-fragment=\"1\"\u003e RFC 1591: Sistema de Nomes de Domínio (DNS)\u003cbr data-mce-fragment=\"1\"\u003e RFC 1745: BGP4\/IDRP para Interação IP-OSPF\u003cbr data-mce-fragment=\"1\"\u003e RFC 1765: Estouro de Banco de Dados OSPF\u003cbr data-mce-fragment=\"1\"\u003e RFC 1771: Protocolo de Gateway de Borda 4\u003cbr data-mce-fragment=\"1\"\u003e RFC 1772: Aplicação do Protocolo de Gateway de Borda na Internet\u003cbr data-mce-fragment=\"1\"\u003e RFC 1812: Requisitos para Roteadores IP Versão 4\u003cbr data-mce-fragment=\"1\"\u003e RFC 1965: Confederações de Sistemas Autônomos para BGP\u003cbr data-mce-fragment=\"1\"\u003e RFC 1981: Descoberta de Unidade Máxima de Transmissão (MTU) de Caminho para IPv6\u003cbr data-mce-fragment=\"1\"\u003e RFC 1997: Atributo de Comunidades BGP\u003cbr data-mce-fragment=\"1\"\u003e RFC 2030: Protocolo de Tempo de Rede Simples (SNTP)\u003cbr data-mce-fragment=\"1\"\u003e RFC 2068: Servidor HTTP\u003cbr data-mce-fragment=\"1\"\u003e RFC 2080: RIPng para IPv6\u003cbr data-mce-fragment=\"1\"\u003e RFC 2081: Declaração de Aplicabilidade do Protocolo RIPng\u003cbr data-mce-fragment=\"1\"\u003e RFC 2131: Agente de retransmissão BOOTP\/Protocolo de Configuração Dinâmica de Host (DHCP)* e servidor DHCP*\u003cbr data-mce-fragment=\"1\"\u003e RFC 2138: Autenticação RADIUS\u003cbr data-mce-fragment=\"1\"\u003e RFC 2139: Contabilidade RADIUS\u003cbr data-mce-fragment=\"1\"\u003e RFC 2154: OSPF com Assinaturas Digitais (senha, Message Digest 5)\u003cbr data-mce-fragment=\"1\"\u003e RFC 2236: IGMP v2\u003cbr data-mce-fragment=\"1\"\u003e RFC 2267: Filtragem de Entrada de Rede\u003cbr data-mce-fragment=\"1\"\u003e RFC 2270: Sistema autônomo (AS) dedicado BGP-4 para Sites\/Provedor Único\u003cbr data-mce-fragment=\"1\"\u003e RFC 2283: Extensões Multiprocolo para BGP-4\u003cbr data-mce-fragment=\"1\"\u003e RFC 2328: OSPF v2 (modo Borda)\u003cbr data-mce-fragment=\"1\"\u003e RFC 2338: VRRP*\u003cbr data-mce-fragment=\"1\"\u003e RFC 2362: PIM-SM (modo Borda)\u003cbr data-mce-fragment=\"1\"\u003e RFC 2370: Opção LSA Opaca OSPF\u003cbr data-mce-fragment=\"1\"\u003e RFC 2373: Arquitetura de Endereçamento IPv6\u003cbr data-mce-fragment=\"1\"\u003e RFC 2375: Atribuições de Endereço Multicast IPv6\u003cbr data-mce-fragment=\"1\"\u003e RFC 2385: Autenticação TCP MD5 para BGPv4\u003cbr data-mce-fragment=\"1\"\u003e RFC 2439: Amortecimento de Flap de Rota BGP\u003cbr data-mce-fragment=\"1\"\u003e RFC 2453: RIP v2\u003cbr data-mce-fragment=\"1\"\u003e RFC 2460: Protocolo de Internet, v6 (IPv6) especificação\u003cbr data-mce-fragment=\"1\"\u003e RFC 2461: Descoberta de Vizinho para IP Versão 6 (IPv6)\u003cbr data-mce-fragment=\"1\"\u003e RFC 2462: Auto-configuração de Endereço Sem Estado IPv6\u003cbr data-mce-fragment=\"1\"\u003e RFC 2463: ICMPv6\u003cbr data-mce-fragment=\"1\"\u003e RFC 2464: Transmissão de Pacotes IPv6 sobre Redes Ethernet\u003cbr data-mce-fragment=\"1\"\u003e RFC 2474: Precedência DiffServ, incluindo 8 filas\/porta\u003cbr data-mce-fragment=\"1\"\u003e RFC 2475: Funções de Roteador Central e de Borda DiffServ\u003cbr data-mce-fragment=\"1\"\u003e RFC 2526: Endereços Anycast de Sub-rede IPv6 Reservados\u003cbr data-mce-fragment=\"1\"\u003e RFC 2545: Uso de Extensões Multiprocolo BGP-4 para Roteamento Interdomínio IPv6\u003cbr data-mce-fragment=\"1\"\u003e RFC 2547: VPNs BGP\/MPLS\u003cbr data-mce-fragment=\"1\"\u003e RFC 2597: Encaminhamento Assegurado DiffServ (AF)\u003cbr data-mce-fragment=\"1\"\u003e RFC 2598: Encaminhamento Expedito DiffServ (EF)\u003cbr data-mce-fragment=\"1\"\u003e RFC 2710: Descoberta de Ouvinte Multicast (MLD) para IPv6\u003cbr data-mce-fragment=\"1\"\u003e RFC 2711: Opção de Alerta de Roteador IPv6\u003cbr data-mce-fragment=\"1\"\u003e RFC 2740: OSPF para IPv6\u003cbr data-mce-fragment=\"1\"\u003e RFC 2796: Reflexão de Rota BGP (substitui RFC 1966)\u003cbr data-mce-fragment=\"1\"\u003e RFC 2796: Reflexão de Rota\u003cbr data-mce-fragment=\"1\"\u003e RFC 2858: Extensões Multiprocolo para BGP-4\u003cbr data-mce-fragment=\"1\"\u003e RFC 2893: Mecanismos de Transição para Hosts e Roteadores IPv6\u003cbr data-mce-fragment=\"1\"\u003e RFC 2918: Capacidade de Atualização de Rota para BGP-4\u003cbr data-mce-fragment=\"1\"\u003e RFC 3031: Arquitetura de Comutação de Rótulos Multiprotocolo\u003cbr data-mce-fragment=\"1\"\u003e RFC 3032: Codificação de Pilha de Rótulos MPLS\u003cbr data-mce-fragment=\"1\"\u003e RFC 3036: Especificação LDP\u003cbr data-mce-fragment=\"1\"\u003e RFC 3065: Confederações de Sistemas Autônomos para BGP\u003cbr data-mce-fragment=\"1\"\u003e RFC 3176 sFlow\u003cbr data-mce-fragment=\"1\"\u003e RFC 3215: Máquina de Estado LDP\u003cbr data-mce-fragment=\"1\"\u003e RFC 3306: Endereços Multicast IPv6 Baseados em Prefixo Unicast\u003cbr data-mce-fragment=\"1\"\u003e RFC 3376: IGMP v3\u003cbr data-mce-fragment=\"1\"\u003e RFC 3392: Anúncio de Capacidades com BGP-4\u003cbr data-mce-fragment=\"1\"\u003e RFC 3446: Mecanismo de Ponto de Reunião Anycast (RP) usando PIM e MSDP\u003cbr data-mce-fragment=\"1\"\u003e RFC 3478: Reinício Gracioso para Protocolo de Distribuição de Rótulos\u003cbr data-mce-fragment=\"1\"\u003e RFC 3484: Seleção de Endereço Padrão para IPv6\u003cbr data-mce-fragment=\"1\"\u003e RFC 3513: Protocolo de Internet Versão 6 (IPv6) Endereçamento\u003cbr data-mce-fragment=\"1\"\u003e RFC 3569: Multicast Específico de Origem PIM-SSM PIM\u003cbr data-mce-fragment=\"1\"\u003e RFC 3587: Formato de Endereço Unicast Global IPv6\u003cbr data-mce-fragment=\"1\"\u003e RFC 3618: Protocolo de Descoberta de Origem Multicast (MSDP)\u003cbr data-mce-fragment=\"1\"\u003e RFC 3623: Reinício Gracioso OSPF\u003cbr data-mce-fragment=\"1\"\u003e RFC 3768: Protocolo de Redundância de Roteador Virtual (VRRP)*\u003cbr data-mce-fragment=\"1\"\u003e RFC 3810: Descoberta de Ouvinte Multicast Versão 2 (MLDv2) para IP\u003cbr data-mce-fragment=\"1\"\u003e RFC 3973: Modo Denso PIM\u003cbr data-mce-fragment=\"1\"\u003e RFC 4213: Mecanismos Básicos de Transição para Hosts e Roteadores IPv6\u003cbr data-mce-fragment=\"1\"\u003e RFC 4291: Arquitetura de Endereçamento IPv6\u003cbr data-mce-fragment=\"1\"\u003e RFC 4360: Atributo de Comunidades Estendidas BGP\u003cbr data-mce-fragment=\"1\"\u003e RFC 4364: Redes Privadas Virtuais de IP (VPNs) BGP\/MPLS\u003cbr data-mce-fragment=\"1\"\u003e RFC 4443: ICMPv6 para a especificação IPv6\u003cbr data-mce-fragment=\"1\"\u003e RFC 4486: Subcódigos para mensagem de Notificação de Término BGP\u003cbr data-mce-fragment=\"1\"\u003e RFC 4552: Autenticação\/Confidencialidade para OSPFv3\u003cbr data-mce-fragment=\"1\"\u003e RFC 4604: Usando o Protocolo de Gerenciamento de Grupo da Internet Versão 3 (IGMPv3)\u003cbr data-mce-fragment=\"1\"\u003e RFC 4724: Mecanismo de Reinício Gracioso para BGP\u003cbr data-mce-fragment=\"1\"\u003e RFC 4761: Serviço de LAN Privada Virtual (VPLS) usando BGP para auto-descoberta e sinalização\u003cbr data-mce-fragment=\"1\"\u003e RFC 4798: Conectando Ilhas IPv6 sobre MPLS IPv4 Usando Roteadores de Borda de Provedor IPv6 (6PE)\u003cbr data-mce-fragment=\"1\"\u003e RFC 4861: Descoberta de Vizinho para IPv6\u003cbr data-mce-fragment=\"1\"\u003e RFC 4862: Auto-configuração de Endereço Sem Estado IPv6\u003cbr data-mce-fragment=\"1\"\u003e RFC 5095: Depreciação de Cabeçalhos de Roteamento Tipo 0 em IPv6\u003cbr data-mce-fragment=\"1\"\u003e RFC 5286: Especificação Básica para Reroteamento Rápido de IP: Alternativas Sem Loop\u003cbr data-mce-fragment=\"1\"\u003e RFC 5306: Sinalização de Reinício para IS-IS\u003cbr data-mce-fragment=\"1\"\u003e RFC 5308: Roteamento IPv6 com IS-IS\u003cbr data-mce-fragment=\"1\"\u003e RFC 5340: OSPF para IPv6\u003cbr data-mce-fragment=\"1\"\u003e Draft-ietf-bfd-base-09.txt: Detecção de Encaminhamento Bidirecional\u003cbr data-mce-fragment=\"1\"\u003e Draft-ietf-l2vpn-evpn-00.txt: VPN Ethernet Baseada em MPLS BGP\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr data-mce-fragment=\"1\"\u003e\n\n\u003ctd width=\"257\" data-mce-fragment=\"1\"\u003eServiços e Gerenciabilidade\u003c\/td\u003e\n\n\u003ctd width=\"379\" data-mce-fragment=\"1\"\u003eRede Local Extensível Virtual (VXLAN)\u003cbr data-mce-fragment=\"1\"\u003e API REST\u003cbr data-mce-fragment=\"1\"\u003e Sessões NETCONF sobre HTTPS de saída\u003cbr data-mce-fragment=\"1\"\u003e Kit de Extensão Juniper (JET)\u003cbr data-mce-fragment=\"1\"\u003e OpenFlow v1.3\u003cbr data-mce-fragment=\"1\"\u003e CLI do Junos OS\u003cbr data-mce-fragment=\"1\"\u003e Gerenciamento fora de banda: Serial; Ethernet 10\/100\/1000BASE-T\u003cbr data-mce-fragment=\"1\"\u003e Arquivo de configuração ASCII\u003cbr data-mce-fragment=\"1\"\u003e Configuração de recuperação\u003cbr data-mce-fragment=\"1\"\u003e Reversão de configuração\u003cbr data-mce-fragment=\"1\"\u003e Reversão de imagem\u003cbr data-mce-fragment=\"1\"\u003e SNMP: v1, v2c, v3\u003cbr data-mce-fragment=\"1\"\u003e RMON (RFC 2819): Grupos 1, 2, 3, 9\u003cbr data-mce-fragment=\"1\"\u003e Protocolo de Tempo de Rede (NTP)\u003cbr data-mce-fragment=\"1\"\u003e Servidor DHCP\u003cbr data-mce-fragment=\"1\"\u003e Retransmissão DHCP com Opção 82\u003cbr data-mce-fragment=\"1\"\u003e RADIUS\u003cbr data-mce-fragment=\"1\"\u003e TACACS+\u003cbr data-mce-fragment=\"1\"\u003e SSHv2\u003cbr data-mce-fragment=\"1\"\u003e Cópia segura\u003cbr data-mce-fragment=\"1\"\u003e Resolvedor DNS\u003cbr data-mce-fragment=\"1\"\u003e Registro Syslog\u003cbr data-mce-fragment=\"1\"\u003e Monitoramento ambiental\u003cbr data-mce-fragment=\"1\"\u003e Sensor de temperatura\u003cbr data-mce-fragment=\"1\"\u003e Backup de configuração via FTP\/cópia segura\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr data-mce-fragment=\"1\"\u003e\n\n\u003ctd width=\"257\" data-mce-fragment=\"1\"\u003eGerenciamento de Rede — Suporte MIB\u003c\/td\u003e\n\n\u003ctd width=\"379\" data-mce-fragment=\"1\"\u003eJ-Flow\u003cbr data-mce-fragment=\"1\"\u003e RFC 1155: Estrutura de Informações de Gerenciamento (SMI)\u003cbr data-mce-fragment=\"1\"\u003e RFC 1157: SNMPv1\u003cbr data-mce-fragment=\"1\"\u003e RFC 1212, RFC 1213, RFC 1215: MIB-II, MIB tipo Ethernet e traps\u003cbr data-mce-fragment=\"1\"\u003e RFC 1657: MIB BGP-4\u003cbr data-mce-fragment=\"1\"\u003e RFC 1724: MIB RIPv2\u003cbr data-mce-fragment=\"1\"\u003e RFC 1850: MIB OSPFv2\u003cbr data-mce-fragment=\"1\"\u003e RFC 1901: Introdução ao SNMPv2 baseado em Comunidade\u003cbr data-mce-fragment=\"1\"\u003e RFC 1902: Estrutura de Informações de Gerenciamento para a Versão 2 do Protocolo Simples de Gerenciamento de Rede (SNMPv2)\u003cbr data-mce-fragment=\"1\"\u003e RFC 1905, RFC 1907: SNMP v2c, SMIv2 e MIB-II Revisado\u003cbr data-mce-fragment=\"1\"\u003e RFC 2011: SNMPv2 para IP usando SMIv2\u003cbr data-mce-fragment=\"1\"\u003e RFC 2012: SNMPv2 para protocolo de controle de transmissão usando SMIv2\u003cbr data-mce-fragment=\"1\"\u003e RFC 2013: SNMPv2 para protocolo de datagrama de usuário usando SMIv2\u003cbr data-mce-fragment=\"1\"\u003e RFC 2096: MIB da Tabela de Encaminhamento IPv4\u003cbr data-mce-fragment=\"1\"\u003e RFC 2287: MIB de Pacotes de Aplicativos do Sistema\u003cbr data-mce-fragment=\"1\"\u003e RFC 2465: Base de Informações de Gerenciamento para IP Versão 6\u003cbr data-mce-fragment=\"1\"\u003e RFC 2570–2575: SNMPv3, segurança baseada no usuário, criptografia e autenticação\u003cbr data-mce-fragment=\"1\"\u003e RFC 2576: Coexistência entre SNMP Versão 1, Versão 2 e Versão 3\u003cbr data-mce-fragment=\"1\"\u003e RFC 2578: MIB de Estrutura de Informações de Gerenciamento SNMP\u003cbr data-mce-fragment=\"1\"\u003e RFC 2579: Convenções Textuais SNMP para SMIv2\u003cbr data-mce-fragment=\"1\"\u003e RFC 2665: MIB de interface tipo Ethernet\u003cbr data-mce-fragment=\"1\"\u003e RFC 2787: MIB VRRP\u003cbr data-mce-fragment=\"1\"\u003e RFC 2819: MIB RMON\u003cbr data-mce-fragment=\"1\"\u003e RFC 2863: MIB do Grupo de Interface\u003cbr data-mce-fragment=\"1\"\u003e RFC 2863: MIB de Interface\u003cbr data-mce-fragment=\"1\"\u003e RFC 2922: MIB LLDP\u003cbr data-mce-fragment=\"1\"\u003e RFC 2925: MIB Ping\/Traceroute\u003cbr data-mce-fragment=\"1\"\u003e RFC 2932: MIB Multicast IPv4\u003cbr data-mce-fragment=\"1\"\u003e RFC 3413: MIB de Aplicação SNMP\u003cbr data-mce-fragment=\"1\"\u003e RFC 3826: O Algoritmo de Cifra Padrão de Criptografia Avançada (AES) no SNMP\u003cbr data-mce-fragment=\"1\"\u003e RFC 4188: MIB STP e Extensões\u003cbr data-mce-fragment=\"1\"\u003e RFC 4363: Definições de Objetos Gerenciados para Pontes com classes de tráfego, filtragem multicast e extensões VLAN\u003cbr data-mce-fragment=\"1\"\u003e Draft-ietf-idr-bgp4-mibv2-02.txt: MIB BGP-4 Aprimorada\u003cbr data-mce-fragment=\"1\"\u003e Draft-ietf-isis-wg-mib-07\u003cbr data-mce-fragment=\"1\"\u003e Draft-reeder-snmpv3-usm-3desede-00\u003cbr data-mce-fragment=\"1\"\u003e Draft-ietf-idmr-igmp-mib-13\u003cbr data-mce-fragment=\"1\"\u003e Draft-ietf-idmr-pim-mib-09\u003cbr data-mce-fragment=\"1\"\u003e Draft-ietf-bfd-mib-02.txt\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr data-mce-fragment=\"1\"\u003e\n\n\u003ctd width=\"257\" data-mce-fragment=\"1\"\u003eSegurança\u003c\/td\u003e\n\n\u003ctd width=\"379\" data-mce-fragment=\"1\"\u003eCAN\/CSA-22.2 No. 60950-00\/UL 1950 Terceira Edição, Segurança de Equipamentos de Tecnologia da Informação\u003cbr data-mce-fragment=\"1\"\u003e EN 60825-1 Segurança de Produtos a Laser – Parte 1: Classificação de Equipamentos, Requisitos e Guia do Usuário\u003cbr data-mce-fragment=\"1\"\u003e EN 60950 Segurança de Equipamentos de Tecnologia da Informação\u003cbr data-mce-fragment=\"1\"\u003e IEC 60950-1 (2001) Segurança de Equipamentos de Tecnologia da Informação (com desvios por país)\u003cbr data-mce-fragment=\"1\"\u003e EN 60825-1 +A1+A2 (1994) Segurança de Produtos a Laser – Parte 1: Classificação de Equipamentos\u003cbr data-mce-fragment=\"1\"\u003e EN 60825-2 (2000) Segurança de Produtos a Laser – Parte 2: Segurança de Sistemas de Comunicação por Fibra Óptica\u003cbr data-mce-fragment=\"1\"\u003e C-UL para CAN\/CSA 22.2 No.60950-1 (Segunda Edição)\u003cbr data-mce-fragment=\"1\"\u003e TUV\/GS para EN 60950-1, Emenda A1-A4, A11\u003cbr data-mce-fragment=\"1\"\u003e CE-IEC60950-1, todos os desvios de país\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr data-mce-fragment=\"1\"\u003e\n\n\u003ctd width=\"257\" data-mce-fragment=\"1\"\u003eEMC\u003c\/td\u003e\n\n\u003ctd width=\"379\" data-mce-fragment=\"1\"\u003eAS\/NZS CISPR22:2009\u003cbr data-mce-fragment=\"1\"\u003e EN 55022 2006+A1:2007 Emissões Irradiadas Europeias\u003cbr data-mce-fragment=\"1\"\u003e FCC 47CFR, Parte 15 Classe A (2009) Emissões Irradiadas dos EUA\u003cbr data-mce-fragment=\"1\"\u003e VCCI-V-3\/2009.04 e V-4\/2009.04 Emissões Irradiadas Japonesas\u003cbr data-mce-fragment=\"1\"\u003e BSMI CNS 13438 e NCC C6357 Emissões Irradiadas de Taiwan\u003cbr data-mce-fragment=\"1\"\u003e EN 300 386 V1.5.1 Equipamento de Rede de Telecomunicações - Requisitos de EMC\u003cbr data-mce-fragment=\"1\"\u003e ICES-003 Edição 4, Fev 2004 Emissões Irradiadas do Canadá\u003cbr data-mce-fragment=\"1\"\u003e CISPR 24:1997\/A1:2001\/A2:2002 Características de Imunidade de Equipamentos de TI\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr data-mce-fragment=\"1\"\u003e\n\n\u003ctd width=\"257\" data-mce-fragment=\"1\"\u003eImunidade\u003c\/td\u003e\n\n\u003ctd width=\"379\" data-mce-fragment=\"1\"\u003eEN 55024:1998\/A1:2001\/A2:2003 Características de Imunidade de Equipamentos de Tecnologia da Informação\u003cbr data-mce-fragment=\"1\"\u003e EN-61000-3-2 (2006) Harmônicos de Linha de Energia\u003cbr data-mce-fragment=\"1\"\u003e EN-61000-3-3 +A1 +A2 +A3 (1995) Flutuações de Tensão da Linha de Energia\u003cbr data-mce-fragment=\"1\"\u003e EN-61000-4-2 +A1 +A2 (1995) Descarga Eletrostática\u003cbr data-mce-fragment=\"1\"\u003e EN-61000-4-3 +A1+A2 (2002) Imunidade Irradiada\u003cbr data-mce-fragment=\"1\"\u003e EN-61000-4-4 (2004) Transientes Elétricos Rápidos\u003cbr data-mce-fragment=\"1\"\u003e EN-61000-4-5 (2006) Surtos\u003cbr data-mce-fragment=\"1\"\u003e EN-61000-4-6 (2007) Imunidade a Perturbações Conduzidas\u003cbr data-mce-fragment=\"1\"\u003e EN-61000-4-11 (2004) Quedas e Baixas de Tensão\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr data-mce-fragment=\"1\"\u003e\n\n\u003ctd width=\"257\" data-mce-fragment=\"1\"\u003eSistema de Construção de Equipamentos de Rede (NEBS)\u003c\/td\u003e\n\n\u003ctd width=\"379\" data-mce-fragment=\"1\"\u003eSR-3580 Níveis de Critérios NEBS (Conformidade Nível 3)\u003cbr data-mce-fragment=\"1\"\u003e GR-63-Core: NEBS, Proteção Física\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr data-mce-fragment=\"1\"\u003e\n\n\u003ctd width=\"257\" data-mce-fragment=\"1\"\u003eAmbiental\u003c\/td\u003e\n\n\u003ctd width=\"379\" data-mce-fragment=\"1\"\u003eRedução de Substâncias Perigosas (ROHS) 5\/6\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr data-mce-fragment=\"1\"\u003e\n\n\u003ctd width=\"257\" data-mce-fragment=\"1\"\u003eTelecom\u003c\/td\u003e\n\n\u003ctd width=\"379\" data-mce-fragment=\"1\"\u003eCódigo de Identificador de Equipamento de Linguagem Comum (CLEI)\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\n\u003c\/tbody\u003e\n\n\n\u003c\/table\u003e\n[\/specifications]\u003cbr\u003e\u003cbr\u003e[accesories]\n\u003ctable width=\"434\" data-mce-fragment=\"1\"\u003e\n\n\u003ctbody data-mce-fragment=\"1\"\u003e\n\n\u003ctr data-mce-fragment=\"1\"\u003e\n\n\u003ctd colspan=\"2\" width=\"434\" data-mce-fragment=\"1\"\u003ePlacas de Linha\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr data-mce-fragment=\"1\"\u003e\n\n\u003ctd width=\"154\" data-mce-fragment=\"1\"\u003eEX9200-15C\u003c\/td\u003e\n\n\u003ctd width=\"280\" data-mce-fragment=\"1\"\u003ePlaca de linha de 15x 100GbE\/40GbE com MACsec AES-256 para EX9200\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr data-mce-fragment=\"1\"\u003e\n\n\u003ctd width=\"154\" data-mce-fragment=\"1\"\u003eEX9200-40XS\u003c\/td\u003e\n\n\u003ctd width=\"280\" data-mce-fragment=\"1\"\u003ePlaca de linha SFP+ de 40 portas 10GbE com suporte a MACsec AES-256 (requer licença de software SFL para ativação); requer óptica SFP+ vendida separadamente\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr data-mce-fragment=\"1\"\u003e\n\n\u003ctd width=\"154\" data-mce-fragment=\"1\"\u003eEX9200-12QS\u003c\/td\u003e\n\n\u003ctd width=\"280\" data-mce-fragment=\"1\"\u003ePlaca de linha combo de 12 portas 40GbE QSFP+ ou 4 portas 100GbE QSFP28; requer óptica vendida separadamente\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr data-mce-fragment=\"1\"\u003e\n\n\u003ctd width=\"154\" data-mce-fragment=\"1\"\u003eEX9200-MPC\u003c\/td\u003e\n\n\u003ctd width=\"280\" data-mce-fragment=\"1\"\u003eConcentrador de Porta Modular (MPC) EX9200\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr data-mce-fragment=\"1\"\u003e\n\n\u003ctd width=\"154\" data-mce-fragment=\"1\"\u003eEX9200-20F-MIC\u003c\/td\u003e\n\n\u003ctd width=\"280\" data-mce-fragment=\"1\"\u003eCartão de Interface Modular (MIC) EX9200 de 20 portas GBASE-X (meio slot) com suporte a MACsec AES-128 (requer licença de software SFL para ativação); requer EX9200-MPC (pedido separadamente)\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr data-mce-fragment=\"1\"\u003e\n\n\u003ctd width=\"154\" data-mce-fragment=\"1\"\u003eEX9200-10XS-MIC\u003c\/td\u003e\n\n\u003ctd width=\"280\" data-mce-fragment=\"1\"\u003eCartão de Interface Modular (MIC) EX9200 de 10 portas 10GBASE-X (meio slot); requer EX9200-MPC (pedido separadamente)\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\n\u003c\/tbody\u003e\n\n\n\u003c\/table\u003e\n[\/accesories]\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003eChassi Juniper EX9208-RED3B-AC\u003c\/h2\u003e\n\u003cp\u003eO Juniper EX9208-RED3B-AC é uma configuração de chassi EX9208 redundante projetada para implantações de núcleo de campus, agregação e data center de alto desempenho. Inclui um chassi de 8 slots com midplane passivo, dois Motores de Roteamento EX9200-RE2, dois módulos de switch fabric-2 EX9200-SF2, uma bandeja de ventoinha e quatro fontes de alimentação CA de 2520W, juntamente com os painéis em branco necessários.\u003c\/p\u003e\n\n\u003cp\u003eComo parte da Série EX9200, a plataforma EX9208 oferece uma arquitetura modular escalável, forte resiliência e alta densidade de portas para ambientes corporativos e de provedores de serviços exigentes. Esta configuração redundante suporta redundância 1+1 do Mecanismo de Roteamento, redundância 1+1 de fabric e componentes de sistema hot-swappable para melhorar a disponibilidade e simplificar a manutenção.\u003c\/p\u003e\n\n\u003cp\u003eEsta configuração redundante é adequada para organizações que precisam de uma base de comutação modular resiliente com flexibilidade para implantar uma ampla gama de placas de linha EX9200 para designs de rede 1GbE, 10GbE, 25GbE, 40GbE e 100GbE.\u003c\/p\u003e","brand":"Juniper","offers":[{"title":"Default Title","offer_id":48958332797184,"sku":"EX9208-RED3B-AC-NEW","price":72748.53,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0388\/5331\/2557\/files\/ex9208_79cd7ffb-39a6-48db-b903-f4868a2ff79f.jpg?v=1783446546","url":"https:\/\/alotechparts.com\/pt-br\/products\/juniper-ex9208-red3b-ac-chassis","provider":"Alo Tech Solutions","version":"1.0","type":"link"}