{"product_id":"juniper-ex9204-redund3a-dc-chassis","title":"Chassi Juniper EX9204-REDUND3A-DC","description":"\u003cdiv class=\"short-hide\"\u003e[shortdesc]\n\u003cul\u003e\n\n\u003cli\u003eConfiguração do sistema base EX9204\u003c\/li\u003e\n\n\u003cli\u003eChassis de 4 slots com midplane passivo\u003c\/li\u003e\n\n\u003cli\u003e2 x mecanismos de roteamento\u003c\/li\u003e\n\n\u003cli\u003e\u003cspan\u003e2 x módulo de comutação de tecido-2\u003c\/span\u003e\u003c\/li\u003e\n\n\u003cli\u003e\u003cspan\u003e4 x fontes de alimentação DC de 2520W\u003c\/span\u003e\u003c\/li\u003e\n\n\u003cli\u003e\u003cspan\u003e1 x bandeja de ventoinhas\u003c\/span\u003e\u003c\/li\u003e\n\n\u003cli\u003e\u003cspan\u003eTodos os painéis em branco necessários\u003c\/span\u003e\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n[\/shortdesc]\u003c\/div\u003e\n\u003cp\u003e[properties]\u003c\/p\u003e\n\u003ctable width=\"560\"\u003e\n\n\u003ctbody\u003e\n\n\u003ctr\u003e\n\n\u003ctd width=\"218\"\u003ePropriedades\u003c\/td\u003e\n\n\u003ctd width=\"342\"\u003eJuniper EX9204-REDUND3A-DC\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd width=\"218\"\u003eDescrição\u003c\/td\u003e\n\n\u003ctd width=\"342\"\u003eConfiguração do sistema EX9204 redundante: Chassis de 4 slots com midplane passivo e 1 bandeja de ventoinhas, 2 mecanismos de roteamento, 2 módulos de comutação de tecido-2, 4 PSUs DC de 2520W e todos os painéis em branco necessários.\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd width=\"218\"\u003eFamília de produtos\u003c\/td\u003e\n\n\u003ctd\u003eSérie EX9200\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd width=\"218\"\u003eTipo de produto\u003c\/td\u003e\n\n\u003ctd\u003eSwitch Ethernet\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd width=\"218\"\u003eNúmero total de slots\u003c\/td\u003e\n\n\u003ctd\u003e4\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd width=\"218\"\u003eSlots disponíveis para placas de linha\u003c\/td\u003e\n\n\u003ctd\u003e2 com redundância de tecido (3 sem)\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd width=\"218\"\u003eMódulo de comutação de tecido\u003c\/td\u003e\n\n\u003ctd\u003e2x EX9200-SF2\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd colspan=\"2\" width=\"560\"\u003eDensidade máxima de portas GbE (velocidade do cabo)\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd width=\"218\"\u003e1GbE\u003c\/td\u003e\n\n\u003ctd\u003e120\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd width=\"218\"\u003e10GbE\u003c\/td\u003e\n\n\u003ctd\u003e144 (96)\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e25GbE\u003c\/td\u003e\n\n\u003ctd\u003e120\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd width=\"218\"\u003e40GbE\u003c\/td\u003e\n\n\u003ctd\u003e30\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd width=\"218\"\u003e100GbE\u003c\/td\u003e\n\n\u003ctd\u003e30\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd width=\"218\"\u003eTecido\u003c\/td\u003e\n\n\u003ctd width=\"342\"\u003e• Capacidade de backplane de até 3 Tbps\u003cbr\u003e• Capacidade de tecido de até 1,5 Tbps (full duplex) por slot\u003cbr\u003e• Redundância de tecido 1+1\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd width=\"218\"\u003eMecanismo de roteamento\u003c\/td\u003e\n\n\u003ctd width=\"342\"\u003e\n\n\u003cp\u003e•\u003cmeta charset=\"utf-8\"\u003e\u003cspan\u003e2x EX9200-RE\u003c\/span\u003e\u003c\/p\u003e\n\n\u003cp\u003e\u003cspan\u003e•\u003c\/span\u003eMecanismos de roteamento mestre e de backup (redundância 1+1)\u003cbr\u003e• Até 64 gigabytes de DRAM\u003cbr\u003e• Unidade de estado sólido (SSD) dupla conectável na parte frontal (até 64 GB cada)\u003cbr\u003e• Portas de console, serial auxiliar e gerenciamento Ethernet\u003cbr\u003e• Interface de armazenamento USB\u003c\/p\u003e\n\n\n\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd width=\"218\"\u003eSistema operacional\u003c\/td\u003e\n\n\u003ctd width=\"342\"\u003eSistema operacional Juniper Networks Junos\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd width=\"218\"\u003eEnergia\u003c\/td\u003e\n\n\u003ctd width=\"342\"\u003eComporta até quatro fontes de alimentação:\u003cbr\u003e• -40 a -72 V CC (redundância 1+1)\u003cbr\u003eConsumo máximo de energia: 2.199 W (CC)\u003cbr\u003e\n\n\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd width=\"218\"\u003eRefrigeração\u003c\/td\u003e\n\n\u003ctd width=\"342\"\u003e• Fluxo de ar da frente para trás\u003cbr\u003e• Bandeja de ventoinhas hot-swappable com redundância 1+1\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd width=\"218\"\u003eDimensões (L x A x P)\u003c\/td\u003e\n\n\u003ctd width=\"342\"\u003e17,5 x 8,7 x 27,75 pol.\u003cbr\u003e(44,5 x 22,1 x 70,5 cm)\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd width=\"218\"\u003ePeso (totalmente carregado)\u003c\/td\u003e\n\n\u003ctd width=\"342\"\u003e128,0 lbs (58,1 Kg)\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd width=\"218\"\u003eUnidades de rack\u003c\/td\u003e\n\n\u003ctd\u003e5 U\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd colspan=\"2\"\u003eConsumo de energia\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd width=\"218\"\u003eConsumo de energia típico redundante do EX9204\u003c\/td\u003e\n\n\u003ctd\u003e690 W\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd width=\"218\"\u003eConsumo de energia reservado redundante do EX9204\u003c\/td\u003e\n\n\u003ctd\u003e690 W\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd width=\"218\"\u003eUnidades adicionais\u003c\/td\u003e\n\n\u003ctd width=\"342\"\u003eConsumo de energia típico\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd width=\"218\"\u003eMecanismo de roteamento EX9200\u003c\/td\u003e\n\n\u003ctd\u003e90 W\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd width=\"218\"\u003eTecido de comutação EX9200-2\u003c\/td\u003e\n\n\u003ctd\u003e155 W\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd width=\"218\"\u003eUnidades adicionais\u003c\/td\u003e\n\n\u003ctd width=\"342\"\u003eConsumo máximo de energia\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd width=\"218\"\u003eMecanismo de roteamento EX9200\u003c\/td\u003e\n\n\u003ctd\u003e90 W\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd width=\"218\"\u003eTecido de comutação EX9200-2\u003c\/td\u003e\n\n\u003ctd\u003e155 W\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd colspan=\"2\" width=\"560\"\u003eCapacidade da fonte de alimentação\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd width=\"218\"\u003eEntrada CA de 100-120V\u003c\/td\u003e\n\n\u003ctd width=\"342\"\u003e1.167 W\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd width=\"218\"\u003eEntrada CA de 200-240 V\u003c\/td\u003e\n\n\u003ctd width=\"342\"\u003e2.050 W\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd width=\"218\"\u003eEntrada CC de -40 a -72 V\u003c\/td\u003e\n\n\u003ctd width=\"342\"\u003e2.400 W\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd colspan=\"2\" width=\"560\"\u003eNúmero máximo de placas de linha em um chassi\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd width=\"218\"\u003eEX9200-40XS\u003c\/td\u003e\n\n\u003ctd width=\"342\"\u003e3\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd width=\"218\"\u003eEX9200-15C\u003c\/td\u003e\n\n\u003ctd width=\"342\"\u003e2\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd width=\"218\"\u003eEX9200-12QS\u003c\/td\u003e\n\n\u003ctd width=\"342\"\u003e3\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd width=\"218\"\u003eEX9200-32XS\u003c\/td\u003e\n\n\u003ctd width=\"342\"\u003e2\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd width=\"218\"\u003eEX9200-6QS\u003c\/td\u003e\n\n\u003ctd width=\"342\"\u003e2\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd width=\"218\"\u003eEX9200-2C-8XS\u003c\/td\u003e\n\n\u003ctd width=\"342\"\u003e3\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd width=\"218\"\u003eEX9200-40T\u003c\/td\u003e\n\n\u003ctd width=\"342\"\u003e3\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd width=\"218\"\u003eEX9200-40F\u003c\/td\u003e\n\n\u003ctd width=\"342\"\u003e3\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd width=\"218\"\u003eEX9200-MPC\u003c\/td\u003e\n\n\u003ctd width=\"342\"\u003e3\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\n\u003c\/tbody\u003e\n\n\n\u003c\/table\u003e\n\u003cp\u003e[\/properties]\u003cbr\u003e\u003cbr\u003e[specifications]\u003c\/p\u003e\n\u003ctable width=\"636\"\u003e\n\n\u003ctbody\u003e\n\n\u003ctr\u003e\n\n\u003ctd width=\"257\"\u003eEspecificações\u003c\/td\u003e\n\n\u003ctd width=\"379\"\u003eEX9204-REDUND3A-DC\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd width=\"257\"\u003eCapacidade do backplane\u003c\/td\u003e\n\n\u003ctd width=\"379\"\u003eAté 3 Tbps\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd width=\"257\"\u003eLargura de banda máxima do tecido\/slot\u003c\/td\u003e\n\n\u003ctd width=\"379\"\u003e1,5 Tbps\/slot\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd width=\"257\"\u003eThroughput do tecido de comutação por slot\u003c\/td\u003e\n\n\u003ctd width=\"379\"\u003e480 Gbps (EX9200-SF2)\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003eRE DRAM\u003c\/td\u003e\n\n\u003ctd\u003e16 GB\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003eRE CPU\u003c\/td\u003e\n\n\u003ctd\u003e1,73 GHz, quad-core\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003eArmazenamento RE\u003c\/td\u003e\n\n\u003ctd\u003e32 GB\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd colspan=\"2\" width=\"636\"\u003eRecursos de Software\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd width=\"257\"\u003eAlta disponibilidade\u003c\/td\u003e\n\n\u003ctd width=\"379\"\u003eHardware projetado para operação contínua:\u003cbr\u003e• Arquitetura segura e modular que isola falhas\u003cbr\u003e• Planos de controle e encaminhamento separados que aprimoram a escalabilidade e a resiliência\u003cbr\u003e• Failover transparente e recuperação de rede\u003cbr\u003e• Troca elegante de mecanismo de roteamento (GRES)\u003cbr\u003e• Roteamento ativo ininterrupto (NSR)\u003cbr\u003e• Ponte ininterrupta (NSB)\u003cbr\u003e• Atualização de software em serviço unificada (ISSU unificada)*\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd width=\"257\"\u003eRecursos da camada 2\u003c\/td\u003e\n\n\u003ctd width=\"379\"\u003eAté 1 milhão de endereços de controle de acesso à mídia (MAC)\u003cbr\u003eAté 512.000 entradas do Protocolo de Resolução de Endereços (ARP) com licença ML (256.000 entradas sem licença ML)\u003cbr\u003eAté 512.000 entradas de Bloco de Informações de Encaminhamento (FIB) com licença ML (256.000 entradas sem licença ML)\u003cbr\u003eQuadros Jumbo (máximo de 9.192 bytes)\u003cbr\u003e32.000 VLANs\u003cbr\u003eProtocolo de Registro de VLAN\u003cbr\u003e3ad – Protocolo de Controle de Agregação de Link (LACP)\u003cbr\u003e1D – Protocolo Spanning Tree (STP)\u003cbr\u003e1w – Protocolo Rapid Spanning Tree (RSTP)\u003cbr\u003e1s – Protocolo Multiple Spanning Tree (MSTP)\u003cbr\u003eProtocolo Spanning Tree de VLAN (VSTP)\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd width=\"257\"\u003eRecursos da camada 3\u003c\/td\u003e\n\n\u003ctd width=\"379\"\u003e1 milhão de base de informações de roteamento IPv4 (RIB)\u003cbr\u003e1 milhão de RIB IPv6\u003cbr\u003eRoteamento estático\u003cbr\u003eRIP v1\/v2\u003cbr\u003eOSPF v1\/v2\u003cbr\u003eOSPF v3\u003cbr\u003eEncaminhamento baseado em filtro\u003cbr\u003eProtocolo de redundância de roteador virtual (VRRP)*\u003cbr\u003eIPv6\u003cbr\u003eDetecção de encaminhamento bidirecional (BFD)\u003cbr\u003eRoteadores virtuais\u003cbr\u003eBGP (licença de recurso avançado)\u003cbr\u003eIS-IS (licença de recurso avançado)\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd width=\"257\"\u003eTunelamento de hardware\u003c\/td\u003e\n\n\u003ctd width=\"379\"\u003eTúneis GRE\u003cbr\u003eRecursos MPLS (Licença de recurso avançado)\u003cbr\u003eVPLS\u003cbr\u003eVPNs BGP\/MPLS\u003cbr\u003eVPNs Ethernet\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd width=\"257\"\u003eMulticast\u003c\/td\u003e\n\n\u003ctd width=\"379\"\u003eAté 256.000 rotas multicast IPv4\u003cbr\u003eAté 256.000 rotas multicast IPv6\u003cbr\u003eProtocolo de Gerenciamento de Grupo da Internet (IGMP) v1\/v2\/v3\u003cbr\u003eSnooping IGMP\u003cbr\u003eSnooping MLD\u003cbr\u003eMulticast Independente de Protocolo PIM-SM, PIM-SSM, PIM-DM\u003cbr\u003eProtocolo de Descoberta de Fonte Multicast (MSDP)\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd width=\"257\"\u003eFiltros de firewall\u003c\/td\u003e\n\n\u003ctd width=\"379\"\u003eACLs de porta\u003cbr\u003eACLs de VLAN\u003cbr\u003eACLs de roteador\u003cbr\u003eProteção contra negação de serviço (DoS) do plano de controle\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd width=\"257\"\u003eQualidade de serviço (QoS)\u003c\/td\u003e\n\n\u003ctd width=\"379\"\u003e16.000 policiadores por chassi\u003cbr\u003e8 filas de saída por porta\u003cbr\u003eAgendamento de detecção precoce aleatória ponderada (WRED)\u003cbr\u003eFilas round-robin ponderadas (WRR)\u003cbr\u003eFilas de prioridade estrita\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd width=\"257\"\u003eVirtualização\u003c\/td\u003e\n\n\u003ctd width=\"379\"\u003eIntegração com Juniper Networks Contrail\u003cbr\u003eIntegração com controladores VMware NSX SDN\u003cbr\u003eProtocolos de virtualização de rede como Virtual eXtensible LAN (VXLAN) e Open vSwitch Database (OVSDB)\u003cbr\u003eGateway VXLAN Camada 2 e Camada 3\u003cbr\u003eEVPN\u003cbr\u003eEVPN Multihoming (EVPN Switch Interface – Agregação de link)\u003cbr\u003eGateway EVPN VXLAN L2 e L3\u003cbr\u003eServiço de LAN Privada Virtual (VPLS) para Interconexão de Data Center\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd width=\"257\"\u003eGerenciamento\u003c\/td\u003e\n\n\u003ctd width=\"379\"\u003eInterface de linha de comando (CLI) do Junos OS\u003cbr\u003eProtocolo de gerenciamento Junos XML\u003cbr\u003eSNMP v1\/v2\/v3\u003cbr\u003eRADIUS\u003cbr\u003eTACACS+\u003cbr\u003eAmplo suporte MIB\u003cbr\u003eEspelhamento de porta baseado em firewall\u003cbr\u003eProtocolo de Descoberta da Camada de Link (LLDP)\u003cbr\u003eSoluções Avançadas de Insight (AIS)\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003eTemperatura de operação\u003c\/td\u003e\n\n\u003ctd\u003e32° a 104° F (0° a 40° C)\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003eTemperatura de armazenamento\u003c\/td\u003e\n\n\u003ctd\u003e-40° a 158° F (-40° a 70° C)\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003eAltitude de operação\u003c\/td\u003e\n\n\u003ctd\u003eAté 10.000 pés (3.048 m)\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003eSísmico\u003c\/td\u003e\n\n\u003ctd\u003eProjetado para atender aos requisitos de terremoto GR-63, Zona 4\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003eUmidade relativa de operação\u003c\/td\u003e\n\n\u003ctd\u003e5% a 90% (sem condensação)\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003eUmidade relativa não operacional\u003c\/td\u003e\n\n\u003ctd\u003e5 a 95% (sem condensação)\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd width=\"257\"\u003eConformidade com IEEE\u003c\/td\u003e\n\n\u003ctd width=\"379\"\u003eIEEE 802.1AB: Protocolo de Descoberta da Camada de Link (LLDP)\u003cbr\u003eIEEE 802.1D-2004: Protocolo Spanning Tree (STP)\u003cbr\u003eIEEE 802.1p: Priorização de classe de serviço (CoS)\u003cbr\u003eIEEE 802.1Q: Redes locais virtualmente interligadas\u003cbr\u003eIEEE 802.1s: Protocolo Multiple Spanning Tree (MSTP)\u003cbr\u003eIEEE 802.1w: Protocolo Rapid Spanning Tree (RSTP)\u003cbr\u003eIEEE 802.3: 10BASE-T\u003cbr\u003eIEEE 802.3u: 100BASE-T\u003cbr\u003eIEEE 802.3ab: 1000BASE-T\u003cbr\u003eIEEE 802.3z: 1000BASE-X\u003cbr\u003eIEEE 802.3ae: Ethernet de 10 Gigabits\u003cbr\u003eIEEE 802.3ba: Ethernet de 40 Gigabits\/100 Gigabits\u003cbr\u003eIEEE 802.3ah: Operação, Administração e Manutenção (OAM)\u003cbr\u003eIEEE 802.3ad: Protocolo de Controle de Agregação de Link (LACP)\u003cbr\u003eIEEE 802.1ae: Segurança de Controle de Acesso à Mídia\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd width=\"257\"\u003eConformidade com RFC\u003c\/td\u003e\n\n\u003ctd width=\"379\"\u003eRFC 768: UDP\u003cbr\u003eRFC 783: Protocolo Trivial de Transferência de Arquivos (TFTP)\u003cbr\u003eRFC 791: IP\u003cbr\u003eRFC 792: Protocolo de Mensagens de Controle da Internet (ICMP)\u003cbr\u003eRFC 793: TCP\u003cbr\u003eRFC 826: ARP\u003cbr\u003eRFC 854: Cliente e servidor Telnet\u003cbr\u003eRFC 894: IP sobre Ethernet\u003cbr\u003eRFC 903: Protocolo de Resolução de Endereços Reversa (RARP)\u003cbr\u003eRFC 906: Bootstrap TFTP\u003cbr\u003eRFC 951, 1542: BootP\u003cbr\u003eRFC 1027: Proxy ARP\u003cbr\u003eRFC 1058: RIP v1\u003cbr\u003eRFC 1112: IGMP v1\u003cbr\u003eRFC 1122: Requisitos de Host\u003cbr\u003eRFC 1195: Uso de Interconexão de Sistemas Abertos (OSI) IS-IS para Roteamento em TCP\/IP e Ambientes Duais (somente transporte TCP\/IP)\u003cbr\u003eRFC 1256: Protocolo de Descoberta de Roteador ICMP IPv4 (IRDP)\u003cbr\u003eRFC 1492: TACACS+\u003cbr\u003eRFC 1519: Roteamento Interdomínio Sem Classe (CIDR)\u003cbr\u003eRFC 1587: Opção OSPF NSSA\u003cbr\u003eRFC 1591: Sistema de Nomes de Domínio (DNS)\u003cbr\u003eRFC 1745: BGP4\/IDRP para Interação IP-OSPF\u003cbr\u003eRFC 1765: Estouro de Banco de Dados OSPF\u003cbr\u003eRFC 1771: Protocolo Border Gateway 4\u003cbr\u003eRFC 1772: Aplicação do Protocolo Border Gateway na Internet\u003cbr\u003eRFC 1812: Requisitos para Roteadores IP Versão 4\u003cbr\u003eRFC 1965: Confederações de Sistema Autônomo para BGP\u003cbr\u003eRFC 1981: Descoberta de unidade máxima de transmissão (MTU) de caminho para IPv6\u003cbr\u003eRFC 1997: Atributo de Comunidades BGP\u003cbr\u003eRFC 2030: Protocolo de Tempo de Rede Simples (SNTP)\u003cbr\u003eRFC 2068: Servidor HTTP\u003cbr\u003eRFC 2080: RIPng para IPv6\u003cbr\u003eRFC 2081: Declaração de Aplicabilidade do Protocolo RIPng\u003cbr\u003eRFC 2131: Agente de retransmissão BOOTP\/Protocolo de Configuração Dinâmica de Host (DHCP)* e servidor DHCP*\u003cbr\u003eRFC 2138: Autenticação RADIUS\u003cbr\u003eRFC 2139: Contabilidade RADIUS\u003cbr\u003eRFC 2154: OSPF com Assinaturas Digitais (senha, Message Digest 5)\u003cbr\u003eRFC 2236: IGMP v2\u003cbr\u003eRFC 2267: Filtragem de Entrada de Rede\u003cbr\u003eRFC 2270: Sistema autônomo (AS) Dedicado BGP-4 para Sites\/Provedor Único\u003cbr\u003eRFC 2283: Extensões Multiprotocolo para BGP-4\u003cbr\u003eRFC 2328: OSPF v2 (modo Edge)\u003cbr\u003eRFC 2338: VRRP*\u003cbr\u003eRFC 2362: PIM-SM (modo Edge)\u003cbr\u003eRFC 2370: Opção LSA Opaca OSPF\u003cbr\u003eRFC 2373: Arquitetura de Endereçamento IPv6\u003cbr\u003eRFC 2375: Atribuições de Endereço Multicast IPv6\u003cbr\u003eRFC 2385: Autenticação TCP MD5 para BGPv4\u003cbr\u003eRFC 2439: Amortecimento de Flap de Rota BGP\u003cbr\u003eRFC 2453: RIP v2\u003cbr\u003eRFC 2460: Protocolo de Internet, v6 (IPv6) especificação\u003cbr\u003eRFC 2461: Descoberta de Vizinho para IP Versão 6 (IPv6)\u003cbr\u003eRFC 2462: Autoconfiguração de Endereço Sem Estado IPv6\u003cbr\u003eRFC 2463: ICMPv6\u003cbr\u003eRFC 2464: Transmissão de Pacotes IPv6 sobre Redes Ethernet\u003cbr\u003eRFC 2474: Precedência DiffServ, incluindo 8 filas\/porta\u003cbr\u003eRFC 2475: Funções de Roteador Central e de Borda DiffServ\u003cbr\u003eRFC 2526: Endereços Anycast de Sub-rede IPv6 Reservados\u003cbr\u003eRFC 2545: Uso de Extensões Multiprotocolo BGP-4 para Roteamento Interdomínio IPv6\u003cbr\u003eRFC 2547: VPNs BGP\/MPLS\u003cbr\u003eRFC 2597: Encaminhamento Assegurado DiffServ (AF)\u003cbr\u003eRFC 2598: Encaminhamento Expedito DiffServ (EF)\u003cbr\u003eRFC 2710: Descoberta de Ouvinte Multicast (MLD) para IPv6\u003cbr\u003eRFC 2711: Opção de Alerta de Roteador IPv6\u003cbr\u003eRFC 2740: OSPF para IPv6\u003cbr\u003eRFC 2796: Reflexão de Rota BGP (substitui RFC 1966)\u003cbr\u003eRFC 2796: Reflexão de Rota\u003cbr\u003eRFC 2858: Extensões Multiprotocolo para BGP-4\u003cbr\u003eRFC 2893: Mecanismos de Transição para Hosts e Roteadores IPv6\u003cbr\u003eRFC 2918: Capacidade de Atualização de Rota para BGP-4\u003cbr\u003eRFC 3031: Arquitetura de Comutação de Rótulo Multiprotocolo\u003cbr\u003eRFC 3032: Codificação de Pilha de Rótulos MPLS\u003cbr\u003eRFC 3036: Especificação LDP\u003cbr\u003eRFC 3065: Confederações de Sistema Autônomo para BGP\u003cbr\u003eRFC 3176 sFlow\u003cbr\u003eRFC 3215: Máquina de Estado LDP\u003cbr\u003eRFC 3306: Endereços Multicast IPv6 Baseados em Prefixo Unicast\u003cbr\u003eRFC 3376: IGMP v3\u003cbr\u003eRFC 3392: Anúncio de Capacidades com BGP-4\u003cbr\u003eRFC 3446: Mecanismo Anycast Rendevous Point (RP) usando PIM e MSDP\u003cbr\u003eRFC 3478: Reinício Gracioso para Protocolo de Distribuição de Rótulos\u003cbr\u003eRFC 3484: Seleção de Endereço Padrão para IPv6\u003cbr\u003eRFC 3513: Protocolo de Internet Versão 6 (IPv6) Endereçamento\u003cbr\u003eRFC 3569: PIM-SSM PIM Multicast Específico da Fonte\u003cbr\u003eRFC 3587: Formato de Endereço Unicast Global IPv6\u003cbr\u003eRFC 3618: Protocolo de Descoberta de Fonte Multicast (MSDP)\u003cbr\u003eRFC 3623: Reinício Gracioso OSPF\u003cbr\u003eRFC 3768: Protocolo de Redundância de Roteador Virtual (VRRP)*\u003cbr\u003eRFC 3810: Descoberta de Ouvinte Multicast Versão 2 (MLDv2) para IP\u003cbr\u003eRFC 3973: PIM-Dense Mode\u003cbr\u003eRFC 4213: Mecanismos de Transição Básicos para Hosts e Roteadores IPv6\u003cbr\u003eRFC 4291: Arquitetura de Endereçamento IPv6\u003cbr\u003eRFC 4360: Atributo de Comunidades Estendidas BGP\u003cbr\u003eRFC 4364: VPNs IP BGP\/MPLS (VPNs)\u003cbr\u003eRFC 4443: ICMPv6 para a especificação IPv6\u003cbr\u003eRFC 4486: Subcódigos para mensagem de Notificação de Interrupção BGP\u003cbr\u003eRFC 4552: Autenticação\/Confidencialidade para OSPFv3\u003cbr\u003eRFC 4604: Usando Protocolo de Gerenciamento de Grupo da Internet Versão 3 (IGMPv3)\u003cbr\u003eRFC 4724: Mecanismo de Reinício Gracioso para BGP\u003cbr\u003eRFC 4761: Serviço de LAN Privada Virtual (VPLS) usando BGP para autodiscoberta e sinalização\u003cbr\u003eRFC 4798: Conectando Ilhas IPv6 sobre MPLS IPv4 Usando Roteadores de Borda de Provedor IPv6 (6PE)\u003cbr\u003eRFC 4861: Descoberta de Vizinho para IPv6\u003cbr\u003eRFC 4862: Autoconfiguração de Endereço Sem Estado IPv6\u003cbr\u003eRFC 5095: Depreciação de Cabeçalhos de Roteamento Tipo 0 em IPv6\u003cbr\u003eRFC 5286, Especificação Básica para Rerroteamento Rápido de IP: Alternativas Sem Loop\u003cbr\u003eRFC 5306: Sinalização de Reinício para IS-IS\u003cbr\u003eRFC 5308: Roteamento IPv6 com IS-IS\u003cbr\u003eRFC 5340: OSPF para IPv6\u003cbr\u003eDraft-ietf-bfd-base-09.txt: Detecção de Encaminhamento Bidirecional\u003cbr\u003eDraft-ietf-l2vpn-evpn-00.txt: VPN Ethernet baseada em BGP MPLS\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd width=\"257\"\u003eServiços e Gerenciabilidade\u003c\/td\u003e\n\n\u003ctd width=\"379\"\u003eRede Local Virtual Extensível (VXLAN)\u003cbr\u003eAPI REST\u003cbr\u003eSessões NETCONF sobre HTTPS de saída\u003cbr\u003eKit de Extensão Juniper (JET)\u003cbr\u003eOpenFlow v1.3\u003cbr\u003eCLI do Junos OS\u003cbr\u003eGerenciamento fora de banda: Serial; Ethernet 10\/100\/1000BASE-T\u003cbr\u003eArquivo de configuração ASCII\u003cbr\u003eConfiguração de resgate\u003cbr\u003eReversão de configuração\u003cbr\u003eReversão de imagem\u003cbr\u003eSNMP: v1, v2c, v3\u003cbr\u003eRMON (RFC 2819): Grupos 1, 2, 3, 9\u003cbr\u003eProtocolo de Tempo de Rede (NTP)\u003cbr\u003eServidor DHCP\u003cbr\u003eRetransmissão DHCP com Opção 82\u003cbr\u003eRADIUS\u003cbr\u003eTACACS+\u003cbr\u003eSSHv2\u003cbr\u003eCópia segura\u003cbr\u003eResolvedor DNS\u003cbr\u003eRegistro de syslog\u003cbr\u003eMonitoramento ambiental\u003cbr\u003eSensor de temperatura\u003cbr\u003eBackup de configuração via FTP\/cópia segura\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003eGerenciamento de Rede — Suporte MIB\u003c\/td\u003e\n\n\u003ctd\u003eJ-Flow\u003cbr\u003eRFC 1155: Estrutura de Informações de Gerenciamento (SMI)\u003cbr\u003eRFC 1157: SNMPv1\u003cbr\u003eRFC 1212, RFC 1213, RFC 1215: MIB-II, MIB tipo Ethernet e armadilhas\u003cbr\u003eRFC 1657: MIB BGP-4\u003cbr\u003eRFC 1724: MIB RIPv2\u003cbr\u003eRFC 1850: MIB OSPFv2\u003cbr\u003eRFC 1901: Introdução ao SNMPv2 baseado em Comunidade\u003cbr\u003eRFC 1902: Estrutura de Informações de Gerenciamento para a Versão 2 do Protocolo Simples de Gerenciamento de Rede (SNMPv2)\u003cbr\u003eRFC 1905, RFC 1907: SNMP v2c, SMIv2 e MIB-II Revisado\u003cbr\u003eRFC 2011: SNMPv2 para IP usando SMIv2\u003cbr\u003eRFC 2012: SNMPv2 para protocolo de controle de transmissão usando SMIv2\u003cbr\u003eRFC 2013: SNMPv2 para protocolo de datagrama de usuário usando SMIv2\u003cbr\u003eRFC 2096: MIB de Tabela de Encaminhamento IPv4\u003cbr\u003eRFC 2287: MIB de Pacotes de Aplicações de Sistema\u003cbr\u003eRFC 2465: Base de Informações de Gerenciamento para IP Versão 6\u003cbr\u003eRFC 2570–2575: SNMPv3, segurança baseada em usuário, criptografia e autenticação\u003cbr\u003eRFC 2576: Coexistência entre SNMP Versão 1, Versão 2 e Versão 3\u003cbr\u003eRFC 2578: MIB de Estrutura de Informações de Gerenciamento SNMP\u003cbr\u003eRFC 2579: Convenções Textuais SNMP para SMIv2\u003cbr\u003eRFC 2665: MIB de Interface tipo Ethernet\u003cbr\u003eRFC 2787: MIB VRRP\u003cbr\u003eRFC 2819: MIB RMON\u003cbr\u003eRFC 2863: MIB de Grupo de Interface\u003cbr\u003eRFC 2863: MIB de Interface\u003cbr\u003eRFC 2922: MIB LLDP\u003cbr\u003eRFC 2925: MIB Ping\/Traceroute\u003cbr\u003eRFC 2932: MIB Multicast IPv4\u003cbr\u003eRFC 3413: MIB de Aplicação SNMP\u003cbr\u003eRFC 3826: O Algoritmo de Cifra AES (Advanced Encryption Standard) no SNMP\u003cbr\u003eRFC 4188: MIB STP e Extensões\u003cbr\u003eRFC 4363: Definições de Objetos Gerenciados para Pontes com classes de tráfego, filtragem multicast e extensões VLAN\u003cbr\u003eDraft-ietf-idr-bgp4-mibv2-02.txt: MIB BGP-4 Aprimorado\u003cbr\u003eDraft-ietf-isis-wg-mib-07\u003cbr\u003eDraft-reeder-snmpv3-usm-3desede-00\u003cbr\u003eDraft-ietf-idmr-igmp-mib-13\u003cbr\u003eDraft-ietf-idmr-pim-mib-09\u003cbr\u003eDraft-ietf-bfd-mib-02.txt\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd width=\"257\"\u003eSegurança\u003c\/td\u003e\n\n\u003ctd width=\"379\"\u003eCAN\/CSA-22.2 No. 60950-00\/UL 1950 Terceira Edição, Segurança de Equipamento de Tecnologia de Informação\u003cbr\u003eEN 60825-1 Segurança de Produtos a Laser—Parte 1: Classificação de Equipamento, Requisitos e Guia do Usuário\u003cbr\u003eEN 60950 Segurança de Equipamento de Tecnologia da Informação\u003cbr\u003eIEC 60950-1 (2001) Segurança de Equipamento de Tecnologia da Informação (com desvios de país)\u003cbr\u003eEN 60825-1 +A1+A2 (1994) Segurança de Produtos a Laser—Parte 1: Classificação de Equipamento\u003cbr\u003eEN 60825-2 (2000) Segurança de Produtos a Laser—Parte 2: Segurança de Sistemas de Comunicação por Fibra Ótica\u003cbr\u003eC-UL para CAN\/CSA 22.2 No.60950-1 (Segunda Edição)\u003cbr\u003eTUV\/GS para EN 60950-1, Emenda A1-A4, A11\u003cbr\u003eCE-IEC60950-1, todos os desvios de país\u003cbr\u003e\n\n\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd width=\"257\"\u003eEMC\u003c\/td\u003e\n\n\u003ctd width=\"379\"\u003eAS\/NZS CISPR22:2009\u003cbr\u003eEN 55022 2006+A1:2007 Emissões Irradiadas Europeias\u003cbr\u003eFCC 47CFR , Parte 15 Classe A (2009) Emissões Irradiadas dos EUA\u003cbr\u003eVCCI-V-3\/2009.04 e V-4\/2009.04 Emissões Irradiadas Japonesas\u003cbr\u003eBSMI CNS 13438 e NCC C6357 Emissões Irradiadas de Taiwan\u003cbr\u003eEN 300 386 V1.5.1 Equipamento de Rede de Telecomunicações - requisitos EMC\u003cbr\u003eICES-003 Edição 4, fev 2004 Emissões Irradiadas do Canadá\u003cbr\u003eCISPR 24:1997\/A1:2001\/A2:2002 Características de Imunidade de Equipamento de TI\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd width=\"257\"\u003eImunidade\u003c\/td\u003e\n\n\u003ctd width=\"379\"\u003eEN 55024:1998\/A1:2001\/A2:2003 Características de Imunidade de Equipamento de Tecnologia da Informação\u003cbr\u003eEN-61000-3-2 (2006) Harmônicos da Linha de Energia\u003cbr\u003eEN-61000-3-3 +A1 +A2 +A3 (1995) Flutuações de Tensão da Linha de Energia\u003cbr\u003eEN-61000-4-2 +A1 +A2 (1995) Descarga Eletrostática\u003cbr\u003eEN-61000-4-3 +A1+A2 (2002) Imunidade Irradiada\u003cbr\u003eEN-61000-4-4 (2004) Transientes Rápidos Elétricos\u003cbr\u003eEN-61000-4-5 (2006) Surtos\u003cbr\u003eEN-61000-4-6 (2007) Imunidade a Perturbações Conduzidas\u003cbr\u003eEN-61000-4-11 (2004) Quedas e Picos de Tensão\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd width=\"257\"\u003eNetwork Equipment Building System (NEBS)\u003c\/td\u003e\n\n\u003ctd width=\"379\"\u003eSR-3580 NEBS Níveis de Critério (Conformidade Nível 3)\u003cbr\u003eGR-63-Core: NEBS, Proteção Física\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd width=\"257\"\u003eAmbiental\u003c\/td\u003e\n\n\u003ctd width=\"379\"\u003eRedução de Substâncias Perigosas (ROHS) 5\/6\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd width=\"257\"\u003eTelco\u003c\/td\u003e\n\n\u003ctd width=\"379\"\u003eCódigo de Identificador de Equipamento de Linguagem Comum (CLEI)\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\n\u003c\/tbody\u003e\n\n\n\u003c\/table\u003e\n\u003cp\u003e[\/specifications]\u003cbr\u003e\u003cbr\u003e[accesories]\u003c\/p\u003e\n\u003ctable width=\"434\"\u003e\n\n\u003ctbody\u003e\n\n\u003ctr\u003e\n\n\u003ctd width=\"434\" colspan=\"2\"\u003ePlacas de Linha\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd width=\"154\"\u003eEX9200-15C\u003c\/td\u003e\n\n\u003ctd width=\"280\"\u003ePlaca de linha 15x 100GbE\/40GbE com MACsec AES-256 para EX9200\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd width=\"154\"\u003eEX9200-40XS\u003c\/td\u003e\n\n\u003ctd width=\"280\"\u003ePlaca de linha SFP+ 10GbE de 40 portas com suporte a MACsec AES-256 (requer licença de software SFL para ativação); requer ópticos SFP+ vendidos separadamente\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd width=\"154\"\u003eEX9200-12QS\u003c\/td\u003e\n\n\u003ctd width=\"280\"\u003ePlaca de linha combinada de 12 portas 40GbE QSFP+ ou 4 portas 100GbE QSFP28; requer ópticos vendidos separadamente\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd width=\"154\"\u003eEX9200-MPC\u003c\/td\u003e\n\n\u003ctd width=\"280\"\u003eConcentrador de Porta Modular (MPC) EX9200\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd width=\"154\"\u003eEX9200-20F-MIC\u003c\/td\u003e\n\n\u003ctd width=\"280\"\u003ePlaca de Interface Modular (MIC) EX9200 20 portas GBASE-X (meio slot) com suporte a MACsec AES-128 (requer licença de software SFL para ativação); requer EX9200-MPC (pedido separadamente)\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd width=\"154\"\u003eEX9200-10XS-MIC\u003c\/td\u003e\n\n\u003ctd width=\"280\"\u003ePlaca de Interface Modular (MIC) EX9200 10 portas 10GBASE-X (meio slot); requer EX9200-MPC (pedido separadamente)\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\n\u003c\/tbody\u003e\n\n\n\u003c\/table\u003e\n\u003cp\u003e[\/accesories]\u003c\/p\u003e\n\u003ch2\u003eChassi Juniper EX9204-REDUND3A-DC\u003c\/h2\u003e\n\u003cp\u003eDescrição Configuração de chassi EX9204 redundante com backplane passivo de 4 slots, motores de roteamento duplos, módulos de tecido de comutação duplos (Switch Fabric-2), quatro fontes de alimentação DC de 2520W, bandeja de ventoinhas e painéis cegos para implementações EX9200 de alta disponibilidade\u003c\/p\u003e","brand":"Juniper","offers":[{"title":"Default Title","offer_id":48958333026560,"sku":"EX9204-REDUND3A-DC-NEW","price":181156.5,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0388\/5331\/2557\/files\/ex9204_b69e05c6-3171-46f8-a9a7-d6c7547e5280.jpg?v=1783446555","url":"https:\/\/alotechparts.com\/pt-br\/products\/juniper-ex9204-redund3a-dc-chassis","provider":"Alo Tech Solutions","version":"1.0","type":"link"}