{"product_id":"cisco-ie-2000-4ts-g-l-switch","title":"Switch Cisco IE-2000-4TS-G-L","description":"\u003cdiv class=\"short-hide\"\u003e[shortdesc]\n\u003cul\u003e\n\n\u003cli\u003eSwitch\u003cbr\u003e\n\n\u003c\/li\u003e\n\n\u003cli\u003eGerenciado\u003c\/li\u003e\n\n\u003cli\u003e4 x 10\/100 + 2 x Gigabit SFP\u003c\/li\u003e\n\n\u003cli\u003eMontagem em trilho DIN\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n[\/shortdesc]\u003c\/div\u003e\n\u003cp\u003e[properties]\u003c\/p\u003e\n\u003ctable data-mce-fragment=\"1\" width=\"432\"\u003e\n\n\u003ctbody data-mce-fragment=\"1\"\u003e\n\n\u003ctr data-mce-fragment=\"1\"\u003e\n\n\u003ctd data-mce-fragment=\"1\" width=\"206\"\u003ePropriedades\u003c\/td\u003e\n\n\u003ctd data-mce-fragment=\"1\" width=\"226\"\u003eCisco IE-2000-4TS-G-L\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr data-mce-fragment=\"1\"\u003e\n\n\u003ctd data-mce-fragment=\"1\" width=\"206\"\u003eDescrição\u003c\/td\u003e\n\n\u003ctd data-mce-fragment=\"1\" width=\"226\"\u003eIE2000 com 4 portas cobre FE e 2 portas SFP GE (LAN Lite)\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr data-mce-fragment=\"1\"\u003e\n\n\u003ctd data-mce-fragment=\"1\" width=\"206\"\u003eFamília do produto\u003c\/td\u003e\n\n\u003ctd data-mce-fragment=\"1\"\u003eIndustrial Ethernet 2000\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr data-mce-fragment=\"1\"\u003e\n\n\u003ctd data-mce-fragment=\"1\" width=\"206\"\u003eTipo do produto\u003c\/td\u003e\n\n\u003ctd data-mce-fragment=\"1\"\u003eSwitch Ethernet\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr data-mce-fragment=\"1\"\u003e\n\n\u003ctd data-mce-fragment=\"1\" width=\"432\" colspan=\"2\"\u003eSwitches\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr data-mce-fragment=\"1\"\u003e\n\n\u003ctd data-mce-fragment=\"1\"\u003eTotal de portas\u003c\/td\u003e\n\n\u003ctd data-mce-fragment=\"1\"\u003e6\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr data-mce-fragment=\"1\"\u003e\n\n\u003ctd data-mce-fragment=\"1\" width=\"206\"\u003ePortas RJ45\u003c\/td\u003e\n\n\u003ctd data-mce-fragment=\"1\"\u003e4 FE\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr data-mce-fragment=\"1\"\u003e\n\n\u003ctd data-mce-fragment=\"1\" width=\"206\"\u003ePortas Combo (SFP ou RJ45)\u003c\/td\u003e\n\n\u003ctd data-mce-fragment=\"1\"\u003e-\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr data-mce-fragment=\"1\"\u003e\n\n\u003ctd data-mce-fragment=\"1\" width=\"206\"\u003ePortas SFP\u003c\/td\u003e\n\n\u003ctd data-mce-fragment=\"1\"\u003e2 GE\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr data-mce-fragment=\"1\"\u003e\n\n\u003ctd data-mce-fragment=\"1\" width=\"206\"\u003eLicença de Fabricação\u003c\/td\u003e\n\n\u003ctd data-mce-fragment=\"1\"\u003eLAN Lite\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr data-mce-fragment=\"1\"\u003e\n\n\u003ctd data-mce-fragment=\"1\" width=\"206\"\u003eTipo de possível atualização\u003c\/td\u003e\n\n\u003ctd data-mce-fragment=\"1\"\u003e3\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr data-mce-fragment=\"1\"\u003e\n\n\u003ctd data-mce-fragment=\"1\" width=\"206\"\u003eIEEE 1588\u003c\/td\u003e\n\n\u003ctd data-mce-fragment=\"1\"\u003e-\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr data-mce-fragment=\"1\"\u003e\n\n\u003ctd data-mce-fragment=\"1\" width=\"206\"\u003eNAT\u003c\/td\u003e\n\n\u003ctd data-mce-fragment=\"1\"\u003e-\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr data-mce-fragment=\"1\"\u003e\n\n\u003ctd data-mce-fragment=\"1\" width=\"206\"\u003ePoE(+)\u003c\/td\u003e\n\n\u003ctd data-mce-fragment=\"1\"\u003e-\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr data-mce-fragment=\"1\"\u003e\n\n\u003ctd data-mce-fragment=\"1\" width=\"206\"\u003eRevestimento Conformal\u003c\/td\u003e\n\n\u003ctd data-mce-fragment=\"1\"\u003e-\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr data-mce-fragment=\"1\"\u003e\n\n\u003ctd data-mce-fragment=\"1\" width=\"432\" colspan=\"2\"\u003eLegenda do tipo de possível atualização\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr data-mce-fragment=\"1\"\u003e\n\n\u003ctd data-mce-fragment=\"1\" width=\"206\"\u003e1\u003c\/td\u003e\n\n\u003ctd data-mce-fragment=\"1\" width=\"226\"\u003eAtualização de software Cisco IOS de LAN Base para IP Lite\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr data-mce-fragment=\"1\"\u003e\n\n\u003ctd data-mce-fragment=\"1\"\u003e2\u003c\/td\u003e\n\n\u003ctd data-mce-fragment=\"1\" width=\"226\"\u003eAtualização de software Cisco IOS de LAN Base Aprimorado para IP Lite\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr data-mce-fragment=\"1\"\u003e\n\n\u003ctd data-mce-fragment=\"1\"\u003e3\u003c\/td\u003e\n\n\u003ctd data-mce-fragment=\"1\" width=\"226\"\u003eAtualização de software Cisco IOS de LAN Lite para LAN Base\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr data-mce-fragment=\"1\"\u003e\n\n\u003ctd data-mce-fragment=\"1\"\u003e4\u003c\/td\u003e\n\n\u003ctd data-mce-fragment=\"1\" width=\"226\"\u003eAtualização de software Cisco IOS de LAN Base para LAN Base Aprimorado e atualização de licença\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr data-mce-fragment=\"1\"\u003e\n\n\u003ctd data-mce-fragment=\"1\"\u003eU\u003c\/td\u003e\n\n\u003ctd data-mce-fragment=\"1\" width=\"226\"\u003eAtualizável para L2NAT via licença de LAN Base Aprimorado ou IP Lite\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr data-mce-fragment=\"1\"\u003e\n\n\u003ctd data-mce-fragment=\"1\" width=\"432\" colspan=\"2\"\u003eRecursos de Software\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr data-mce-fragment=\"1\"\u003e\n\n\u003ctd data-mce-fragment=\"1\"\u003eLicença LAN Lite\u003c\/td\u003e\n\n\u003ctd data-mce-fragment=\"1\"\u003eRecursos Básicos\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr data-mce-fragment=\"1\"\u003e\n\n\u003ctd data-mce-fragment=\"1\" width=\"206\"\u003eComutação de Camada 2\u003c\/td\u003e\n\n\u003ctd data-mce-fragment=\"1\" width=\"226\"\u003eIEEE 802.1, 802.3, 802.3at, padrão 802.3af (ver Tabela 8), VTPv2, NTP, UDLD, CDP, LLDP, filtro MAC Unicast, Protocolo Ethernet Resiliente (REP), Anel de Protocolo de Redundância de Mídia (MRP) (IEC 62439-2)\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr data-mce-fragment=\"1\"\u003e\n\n\u003ctd data-mce-fragment=\"1\" width=\"206\"\u003eSegurança\u003c\/td\u003e\n\n\u003ctd data-mce-fragment=\"1\" width=\"226\"\u003eSCP, SSH, SNMPv3, TACACS+, Servidor\/Cliente RADIUS, Notificação de Endereço MAC, BPDU Guard, sessão SPAN\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr data-mce-fragment=\"1\"\u003e\n\n\u003ctd data-mce-fragment=\"1\" width=\"206\"\u003eMulticast\u003c\/td\u003e\n\n\u003ctd data-mce-fragment=\"1\" width=\"226\"\u003eIGMPv1, v2, v3 Snooping, filtragem IGMP, IGMP Querier\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr data-mce-fragment=\"1\"\u003e\n\n\u003ctd data-mce-fragment=\"1\" width=\"206\"\u003eGerenciamento\u003c\/td\u003e\n\n\u003ctd data-mce-fragment=\"1\" width=\"226\"\u003eFast Boot, Express Setup, Web Device Manager, CNA, Cisco Prime, LMS, MIB, SmartPort, SNMP, syslog\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr data-mce-fragment=\"1\"\u003e\n\n\u003ctd data-mce-fragment=\"1\" width=\"206\"\u003eEthernet Industrial\u003c\/td\u003e\n\n\u003ctd data-mce-fragment=\"1\" width=\"226\"\u003eEtherNet\/IP, Profinet v2\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr data-mce-fragment=\"1\"\u003e\n\n\u003ctd data-mce-fragment=\"1\" width=\"206\"\u003eDimensões (AxLxP) Polegadas\u003c\/td\u003e\n\n\u003ctd data-mce-fragment=\"1\" width=\"226\"\u003e5.1\"A x 2.95\"L x 4.51\"P (130mm A x 74.9mm L x 115mm P)\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr data-mce-fragment=\"1\"\u003e\n\n\u003ctd data-mce-fragment=\"1\" width=\"206\"\u003ePeso\u003c\/td\u003e\n\n\u003ctd data-mce-fragment=\"1\"\u003e2.45 lb (1.11 kg)\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\n\u003c\/tbody\u003e\n\n\n\u003c\/table\u003e\n\u003cp\u003e[\/properties]\u003c\/p\u003e\n\u003cp\u003e[specifications]\u003c\/p\u003e\n\u003ctable data-mce-fragment=\"1\" width=\"774\"\u003e\n\n\u003ctbody data-mce-fragment=\"1\"\u003e\n\n\u003ctr data-mce-fragment=\"1\"\u003e\n\n\u003ctd data-mce-fragment=\"1\" width=\"395\"\u003eEspecificações\u003c\/td\u003e\n\n\u003ctd data-mce-fragment=\"1\" width=\"379\"\u003eIE-2000-4TS-G-L\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr data-mce-fragment=\"1\"\u003e\n\n\u003ctd data-mce-fragment=\"1\" width=\"395\"\u003eDRAM\u003c\/td\u003e\n\n\u003ctd data-mce-fragment=\"1\" width=\"379\"\u003e256 MB DRAM com Memória ECC\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr data-mce-fragment=\"1\"\u003e\n\n\u003ctd data-mce-fragment=\"1\" width=\"395\"\u003eMemória Flash\u003c\/td\u003e\n\n\u003ctd data-mce-fragment=\"1\" width=\"379\"\u003e64 MB\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr data-mce-fragment=\"1\"\u003e\n\n\u003ctd data-mce-fragment=\"1\" width=\"395\"\u003eHardware\u003c\/td\u003e\n\n\u003ctd data-mce-fragment=\"1\" width=\"379\"\u003eFPGA IEEE 1588v2\u003cbr data-mce-fragment=\"1\"\u003eCartão de memória flash SD removível de 1 GB (opcional)\u003cbr data-mce-fragment=\"1\"\u003eConector Mini-USB\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr data-mce-fragment=\"1\"\u003e\n\n\u003ctd data-mce-fragment=\"1\" width=\"395\"\u003eLargura de banda máxima de encaminhamento\u003c\/td\u003e\n\n\u003ctd data-mce-fragment=\"1\" width=\"379\"\u003e3.8 Gbps\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr data-mce-fragment=\"1\"\u003e\n\n\u003ctd data-mce-fragment=\"1\" width=\"395\"\u003eLargura de banda máxima de comutação\u003c\/td\u003e\n\n\u003ctd data-mce-fragment=\"1\" width=\"379\"\u003e7.6 Gbps\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr data-mce-fragment=\"1\"\u003e\n\n\u003ctd data-mce-fragment=\"1\" width=\"395\"\u003eTaxa máxima de encaminhamento\u003c\/td\u003e\n\n\u003ctd data-mce-fragment=\"1\" width=\"379\"\u003e5.66 Mpps\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr data-mce-fragment=\"1\"\u003e\n\n\u003ctd data-mce-fragment=\"1\" width=\"395\"\u003eBuffer de saída\u003c\/td\u003e\n\n\u003ctd data-mce-fragment=\"1\" width=\"379\"\u003e2 MB\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr data-mce-fragment=\"1\"\u003e\n\n\u003ctd data-mce-fragment=\"1\" width=\"395\"\u003eEndereços MAC Unicast\u003c\/td\u003e\n\n\u003ctd data-mce-fragment=\"1\" width=\"379\"\u003e8000\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr data-mce-fragment=\"1\"\u003e\n\n\u003ctd data-mce-fragment=\"1\" width=\"395\"\u003eGrupos Multicast do Protocolo de Gerenciamento de Grupo de Internet (IGMP)\u003c\/td\u003e\n\n\u003ctd data-mce-fragment=\"1\" width=\"379\"\u003e255\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr data-mce-fragment=\"1\"\u003e\n\n\u003ctd data-mce-fragment=\"1\" width=\"395\"\u003eVLANs Máximas\u003c\/td\u003e\n\n\u003ctd data-mce-fragment=\"1\" width=\"379\"\u003e1005\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr data-mce-fragment=\"1\"\u003e\n\n\u003ctd data-mce-fragment=\"1\" width=\"395\"\u003eACEs de Segurança MAC IPv4\u003c\/td\u003e\n\n\u003ctd data-mce-fragment=\"1\" width=\"379\"\u003e384 (modelo TCAM padrão) Bidirecional\u003cbr data-mce-fragment=\"1\"\u003e128 entradas de tradução NAT\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr data-mce-fragment=\"1\"\u003e\n\n\u003ctd data-mce-fragment=\"1\" width=\"395\"\u003eRoteamento IPv4\u003c\/td\u003e\n\n\u003ctd data-mce-fragment=\"1\" width=\"379\"\u003e3500\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr data-mce-fragment=\"1\"\u003e\n\n\u003ctd data-mce-fragment=\"1\" width=\"395\"\u003eRoteamento IPv6\u003c\/td\u003e\n\n\u003ctd data-mce-fragment=\"1\" width=\"379\"\u003e1750\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr data-mce-fragment=\"1\"\u003e\n\n\u003ctd data-mce-fragment=\"1\" width=\"395\"\u003eAlarme\u003c\/td\u003e\n\n\u003ctd data-mce-fragment=\"1\" width=\"379\"\u003eEntradas\/Saídas de Alarme: Duas entradas de alarme para detectar contato seco aberto ou fechado; um relé de saída de alarme\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr data-mce-fragment=\"1\"\u003e\n\n\u003ctd data-mce-fragment=\"1\"\u003eConsumo de energia\u003c\/td\u003e\n\n\u003ctd data-mce-fragment=\"1\"\u003e9.5 - 15 W\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr data-mce-fragment=\"1\"\u003e\n\n\u003ctd data-mce-fragment=\"1\" width=\"395\"\u003eConectores e cabeamento\u003c\/td\u003e\n\n\u003ctd data-mce-fragment=\"1\" width=\"379\"\u003eSFP de 100BASE-FX MMF (2 km), -LX SMF (10 km) -ZX SMF (100 km), BX10 SMF (10 km) e portas baseadas em CWDM SFP: Conectores de fibra LC\u003cbr data-mce-fragment=\"1\"\u003ePortas 10\/100\/1000BASE-T: Conectores RJ-45, cabeamento UTP Categoria 5 de 4 pares\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr data-mce-fragment=\"1\"\u003e\n\n\u003ctd data-mce-fragment=\"1\"\u003eTempo Médio Entre Falhas (MTBF)\u003c\/td\u003e\n\n\u003ctd data-mce-fragment=\"1\"\u003e374.052 horas (42.7 anos)\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr data-mce-fragment=\"1\"\u003e\n\n\u003ctd data-mce-fragment=\"1\" width=\"395\"\u003eTemperatura de Operação\u003c\/td\u003e\n\n\u003ctd data-mce-fragment=\"1\" width=\"379\"\u003e-40C a +70C (gabinete ventilado - fluxo de ar de 40 LFM)\u003cbr data-mce-fragment=\"1\"\u003e-40C a +60C (gabinete selado - fluxo de ar de 0 LFM)\u003cbr data-mce-fragment=\"1\"\u003e-34C a +75C (gabinete equipado com ventoinha ou soprador - fluxo de ar de 200 LFM)\u003cbr data-mce-fragment=\"1\"\u003e-40C a +85C (Teste Ambiental IEC 60068-2-2 - 16 horas)\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr data-mce-fragment=\"1\"\u003e\n\n\u003ctd data-mce-fragment=\"1\" width=\"395\"\u003eTemperatura de Armazenamento\u003c\/td\u003e\n\n\u003ctd data-mce-fragment=\"1\"\u003e-40 C a +85 C\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr data-mce-fragment=\"1\"\u003e\n\n\u003ctd data-mce-fragment=\"1\" width=\"395\"\u003eAltitude de Operação\u003c\/td\u003e\n\n\u003ctd data-mce-fragment=\"1\"\u003eAté 15.000 pés\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr data-mce-fragment=\"1\"\u003e\n\n\u003ctd data-mce-fragment=\"1\" width=\"395\"\u003eCertificações de Segurança\u003c\/td\u003e\n\n\u003ctd data-mce-fragment=\"1\" width=\"379\"\u003eUL\/CSA 60950-1\u003cbr data-mce-fragment=\"1\"\u003eEN 60950-1\u003cbr data-mce-fragment=\"1\"\u003eCB para IEC 60950-1 (com desvios por país)\u003cbr data-mce-fragment=\"1\"\u003eNOM para NOM-019-SCF1 (através de parceiros e distribuidores)\u003cbr data-mce-fragment=\"1\"\u003eMarcação CE\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr data-mce-fragment=\"1\"\u003e\n\n\u003ctd data-mce-fragment=\"1\" width=\"395\"\u003eConformidade com Emissões e Imunidade EMI\u003c\/td\u003e\n\n\u003ctd data-mce-fragment=\"1\" width=\"379\"\u003eFCC 47 CFR Parte 15 Classe A\u003cbr data-mce-fragment=\"1\"\u003eEN 55022A Classe A\u003cbr data-mce-fragment=\"1\"\u003eVCCI Classe A\u003cbr data-mce-fragment=\"1\"\u003eConformidade com RoHS\u003cbr data-mce-fragment=\"1\"\u003eAS\/NZS CISPR 22 Classe A, AS\/NZS CISPR 24\u003cbr data-mce-fragment=\"1\"\u003eCISPR11 Classe A, CISPR22 Classe A\u003cbr data-mce-fragment=\"1\"\u003eICES 003 Classe A\u003cbr data-mce-fragment=\"1\"\u003eKCC - Coreia\u003cbr data-mce-fragment=\"1\"\u003eMarcação CE\u003cbr data-mce-fragment=\"1\"\u003eC-Tick (Austrália)\u003cbr data-mce-fragment=\"1\"\u003eCertificação Rússia\u003cbr data-mce-fragment=\"1\"\u003eCertificação Brasil\u003cbr data-mce-fragment=\"1\"\u003eIEC\/EN\/EN61000-4-2 (Descarga Eletrostática), 15kV \/8kV contato\u003cbr data-mce-fragment=\"1\"\u003eIEC\/EN 61000-4-3 (Imunidade Radiada, 10 e 20 V\/m)\u003cbr data-mce-fragment=\"1\"\u003eIEC\/EN 61000-4-4 (Transientes Rápidos - linha de alimentação de 4kV, linha de dados de 4kV)\u003cbr data-mce-fragment=\"1\"\u003eIEC\/EN 61000-4-5 (Surto 2 kV\/1 kV)\u003cbr data-mce-fragment=\"1\"\u003eIEC\/EN 61000-4-6 (Imunidade Conduzida, 10 V\/emf)\u003cbr data-mce-fragment=\"1\"\u003eIEC\/EN 61000-4-8 (Imunidade a Campo Magnético de Frequência de Alimentação)\u003cbr data-mce-fragment=\"1\"\u003eIEC\/EN 61000-4-9 (Imunidade a Campo Magnético Pulsado)\u003cbr data-mce-fragment=\"1\"\u003eIEC\/EN 61000-4-10 (Imunidade a Campo Magnético Oscilatório)\u003cbr data-mce-fragment=\"1\"\u003eIEC\/EN 61000-4-11 (Imunidade à Tensão de Alimentação CA)\u003cbr data-mce-fragment=\"1\"\u003eIEC\/EN 61000-4-29 (Imunidade a Quedas de Tensão)\u003cbr data-mce-fragment=\"1\"\u003eIEC\/EN 61000-6-1 (Imunidade para Ambientes Industriais Leves)\u003cbr data-mce-fragment=\"1\"\u003eIEC\/EN 61000-6-2 (Imunidade para Ambientes Industriais)\u003cbr data-mce-fragment=\"1\"\u003eIEC\/EN 61000-6-4 Classe A\u003cbr data-mce-fragment=\"1\"\u003eEN 61326\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr data-mce-fragment=\"1\"\u003e\n\n\u003ctd data-mce-fragment=\"1\"\u003eChoque e Vibração\u003c\/td\u003e\n\n\u003ctd data-mce-fragment=\"1\" width=\"379\"\u003eIEC 60068-2-27 (Choque Operacional: 30G 11ms, meio seno)\u003cbr data-mce-fragment=\"1\"\u003eIEC 60068-2-27 (Choque Não Operacional 55-70G, trapezoidal)\u003cbr data-mce-fragment=\"1\"\u003eIEC 60068-2-6, IEC 60068-2-64, EN 61373 (Vibração Operacional)\u003cbr data-mce-fragment=\"1\"\u003eIEC 60068-2-6, IEC 60068-2-64, EN 61373 (Vibração Não Operacional)\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr data-mce-fragment=\"1\"\u003e\n\n\u003ctd data-mce-fragment=\"1\"\u003ePadrões da Indústria\u003c\/td\u003e\n\n\u003ctd data-mce-fragment=\"1\" width=\"379\"\u003eUL508\u003cbr data-mce-fragment=\"1\"\u003eCSA C22.2 No. 142\u003cbr data-mce-fragment=\"1\"\u003eEN 61131-2 (EMC\/EMI, ambiental, mecânico)\u003cbr data-mce-fragment=\"1\"\u003eRevestimento protetor (apenas modelos específicos)\u003cbr data-mce-fragment=\"1\"\u003eMarinha DnV\u003cbr data-mce-fragment=\"1\"\u003eSubestação KEMA (IEEE 1613, IEC 61850-3)\u003cbr data-mce-fragment=\"1\"\u003eFerroviário EN 50155 (EMI\/EMC, ambiental, mecânico)\u003cbr data-mce-fragment=\"1\"\u003eEN50121-3-2\u003cbr data-mce-fragment=\"1\"\u003eEN50121-4\u003cbr data-mce-fragment=\"1\"\u003eNEMA TS-2 (EMC, ambiental, mecânico)\u003cbr data-mce-fragment=\"1\"\u003eCertificação ABB Industrial IT\u003cbr data-mce-fragment=\"1\"\u003eIP30\u003cbr data-mce-fragment=\"1\"\u003eSuporte ODVA Industrial Ethernet\/IP\u003cbr data-mce-fragment=\"1\"\u003eSuporte PROFINETv2.3\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr data-mce-fragment=\"1\"\u003e\n\n\u003ctd data-mce-fragment=\"1\"\u003eLocais Perigosos (* Gabinete necessário)\u003c\/td\u003e\n\n\u003ctd data-mce-fragment=\"1\" width=\"379\"\u003eANSI\/ISA 12.12.01 (Classe 1, Div2 A-D) *\u003cbr data-mce-fragment=\"1\"\u003eEN 60079-0, -15 Certificado ATEX (Classe 1, Zona 2 A-D) *\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr data-mce-fragment=\"1\"\u003e\n\n\u003ctd data-mce-fragment=\"1\"\u003eUmidade\u003c\/td\u003e\n\n\u003ctd data-mce-fragment=\"1\" width=\"379\"\u003eIEC 60068-2-52 (névoa salina, teste Kb) ambientes marinhos\u003cbr data-mce-fragment=\"1\"\u003eIEC 60068 -2-3\u003cbr data-mce-fragment=\"1\"\u003eIEC 60068-2-30\u003cbr data-mce-fragment=\"1\"\u003eUmidade relativa: 5% a 95% sem condensação\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\n\u003c\/tbody\u003e\n\n\n\u003c\/table\u003e\n\u003cp\u003e[\/specifications]\u003c\/p\u003e\n\u003cp\u003e[accesories]\u003c\/p\u003e\n\u003ctable data-mce-fragment=\"1\" width=\"434\"\u003e\n\n\u003ctbody data-mce-fragment=\"1\"\u003e\n\n\u003ctr data-mce-fragment=\"1\"\u003e\n\n\u003ctd data-mce-fragment=\"1\" width=\"154\"\u003eAcessórios e PIDs de Atualização de Licença\u003c\/td\u003e\n\n\u003ctd data-mce-fragment=\"1\" width=\"280\"\u003e\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr data-mce-fragment=\"1\"\u003e\n\n\u003ctd data-mce-fragment=\"1\" width=\"154\"\u003eSD-IE-1GB\u003c\/td\u003e\n\n\u003ctd data-mce-fragment=\"1\" width=\"280\"\u003eCartão de memória SD robusto de 1 GB (deve ser encomendado, não incluído por padrão)\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr data-mce-fragment=\"1\"\u003e\n\n\u003ctd data-mce-fragment=\"1\" width=\"154\"\u003eSTK-RACK-DINRAIL\u003c\/td\u003e\n\n\u003ctd data-mce-fragment=\"1\" width=\"280\"\u003eKit de montagem em trilho DIN de 19 polegadas\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr data-mce-fragment=\"1\"\u003e\n\n\u003ctd data-mce-fragment=\"1\" width=\"154\"\u003eIE-LICENSE-SPARE\u003c\/td\u003e\n\n\u003ctd data-mce-fragment=\"1\" width=\"280\"\u003eLicença sobressalente para atualização de software (recursos L2 para L3, anel MRP, etc.)\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr data-mce-fragment=\"1\"\u003e\n\n\u003ctd data-mce-fragment=\"1\" width=\"154\"\u003eL-IE2000-L-B\u003c\/td\u003e\n\n\u003ctd data-mce-fragment=\"1\" width=\"280\"\u003eLicença eletrônica IE2000 LAN Lite para LAN Base\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr data-mce-fragment=\"1\"\u003e\n\n\u003ctd data-mce-fragment=\"1\" width=\"154\"\u003eL-IE2000-B-E\u003c\/td\u003e\n\n\u003ctd data-mce-fragment=\"1\" width=\"280\"\u003eLicença eletrônica IE2000 LAN Base para LAN Base Aprimorado\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr data-mce-fragment=\"1\"\u003e\n\n\u003ctd data-mce-fragment=\"1\" width=\"154\"\u003eLIC-IE2000-IP-L\u003c\/td\u003e\n\n\u003ctd data-mce-fragment=\"1\" width=\"280\"\u003eLicença eletrônica IE2000 LAN Base ou LAN Base Aprimorado para IPLite\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr data-mce-fragment=\"1\"\u003e\n\n\u003ctd data-mce-fragment=\"1\" width=\"154\"\u003eLIC-IE2000-L-IP\u003c\/td\u003e\n\n\u003ctd data-mce-fragment=\"1\" width=\"280\"\u003eLicença eletrônica IE2000 LAN Lite para IPLite\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr data-mce-fragment=\"1\"\u003e\n\n\u003ctd data-mce-fragment=\"1\" width=\"154\"\u003eLIC-MRP-MANAGER\u003c\/td\u003e\n\n\u003ctd data-mce-fragment=\"1\" width=\"280\"\u003eLicença de Gerenciador de Anel MRP\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr data-mce-fragment=\"1\"\u003e\n\n\u003ctd data-mce-fragment=\"1\" width=\"154\"\u003eLIC-MRP-Client\u003c\/td\u003e\n\n\u003ctd data-mce-fragment=\"1\" width=\"280\"\u003eLicença de Cliente de Anel MRP\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr data-mce-fragment=\"1\"\u003e\n\n\u003ctd data-mce-fragment=\"1\" width=\"154\"\u003eWallmount-IE2k-04\u003c\/td\u003e\n\n\u003ctd data-mce-fragment=\"1\" width=\"280\"\u003eAcessório de kit de montagem na parede para PID de 4 portas downlink do IE2000\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr data-mce-fragment=\"1\"\u003e\n\n\u003ctd data-mce-fragment=\"1\"\u003eFontes de alimentação da série IE 2000\u003c\/td\u003e\n\n\u003ctd data-mce-fragment=\"1\"\u003e\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr data-mce-fragment=\"1\"\u003e\n\n\u003ctd data-mce-fragment=\"1\"\u003eNúmero do produto\u003c\/td\u003e\n\n\u003ctd data-mce-fragment=\"1\"\u003ePotência\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr data-mce-fragment=\"1\"\u003e\n\n\u003ctd data-mce-fragment=\"1\"\u003ePWR-IE50W-AC\u003c\/td\u003e\n\n\u003ctd data-mce-fragment=\"1\"\u003eFonte de alimentação CA de 50W\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr data-mce-fragment=\"1\"\u003e\n\n\u003ctd data-mce-fragment=\"1\"\u003ePWR-IE50W-AC-L\u003c\/td\u003e\n\n\u003ctd data-mce-fragment=\"1\"\u003eFonte de alimentação CA-L de 50W\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr data-mce-fragment=\"1\"\u003e\n\n\u003ctd data-mce-fragment=\"1\"\u003ePWR-IE65W-PC-AC\u003c\/td\u003e\n\n\u003ctd data-mce-fragment=\"1\"\u003eFonte de alimentação CA de 65W para PC\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr data-mce-fragment=\"1\"\u003e\n\n\u003ctd data-mce-fragment=\"1\"\u003ePWR-IE65W-PC-DC\u003c\/td\u003e\n\n\u003ctd data-mce-fragment=\"1\"\u003eFonte de alimentação CC de 65W para PC\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr data-mce-fragment=\"1\"\u003e\n\n\u003ctd data-mce-fragment=\"1\"\u003ePWR-IE170W-PC- AC\u003c\/td\u003e\n\n\u003ctd data-mce-fragment=\"1\"\u003eFonte de alimentação CA de 170W para PC\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr data-mce-fragment=\"1\"\u003e\n\n\u003ctd data-mce-fragment=\"1\"\u003ePWR-IE170W-PC- DC\u003c\/td\u003e\n\n\u003ctd data-mce-fragment=\"1\"\u003eFonte de alimentação CC de 170W para PC\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr data-mce-fragment=\"1\"\u003e\n\n\u003ctd data-mce-fragment=\"1\"\u003ePWR-IE240W-PCAC-L\u003c\/td\u003e\n\n\u003ctd data-mce-fragment=\"1\"\u003eFonte de alimentação CA-L de 240W para PC\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr data-mce-fragment=\"1\"\u003e\n\n\u003ctd data-mce-fragment=\"1\"\u003ePWR-IE480W-PCAC-L\u003c\/td\u003e\n\n\u003ctd data-mce-fragment=\"1\"\u003eFonte de alimentação CA-L de 480W para PC\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\n\u003c\/tbody\u003e\n\n\n\u003c\/table\u003e\n\u003cp\u003e[\/accesories]\u003c\/p\u003e\n\u003ch2\u003eSwitch Ethernet Industrial Cisco IE-2000-4TS-G-L\u003c\/h2\u003e\n\u003cp\u003eO Cisco IE-2000-4TS-G-L é um switch Ethernet industrial compacto e robusto projetado para fornecer conectividade de rede confiável em ambientes desafiadores. Este switch possui 4 portas Fast Ethernet e 2 slots SFP, tornando-o uma solução ideal para conectar vários dispositivos industriais, como câmeras IP, sensores e controladores. O IE-2000-4TS-G-L é projetado para suportar condições adversas, garantindo operação contínua em ambientes industriais exigentes, ao mesmo tempo em que oferece recursos essenciais de gerenciamento da Camada 2 para segmentação de rede e controle de tráfego.\u003c\/p\u003e\n\u003ch3\u003ePrincipais recursos:\u003c\/h3\u003e\n\u003cul\u003e\n\n\u003cli\u003e\n\n\u003cstrong\u003e4 portas Fast Ethernet:\u003c\/strong\u003e Fornece conectividade de dados confiável para uma variedade de dispositivos industriais, garantindo comunicação de rede estável e eficiente.\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cstrong\u003e2 Slots SFP:\u003c\/strong\u003e Oferece opções flexíveis de uplink com conectividade de fibra, garantindo transferência de dados de alta velocidade e escalabilidade de rede.\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cstrong\u003eDesign Reforçado:\u003c\/strong\u003e Construído para operar em ambientes industriais agressivos, capaz de suportar temperaturas extremas, choque e vibração.\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cstrong\u003eGerenciamento de Camada 2:\u003c\/strong\u003e Inclui recursos essenciais de Camada 2, como VLANs, QoS e IGMP snooping, proporcionando flexibilidade e controle sobre o tráfego de rede.\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cstrong\u003eFator de Forma Compacto:\u003c\/strong\u003e Projetado para instalações com restrição de espaço, tornando-o adequado para pequenos gabinetes e armários industriais.\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\u003ch3\u003eVisão Geral Técnica:\u003c\/h3\u003e\n\u003cul\u003e\n\n\u003cli\u003e\n\n\u003cstrong\u003eRecomendado para:\u003c\/strong\u003e Ambientes industriais que exigem conectividade Ethernet confiável com uplinks de fibra e recursos básicos de gerenciamento.\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cstrong\u003ePortas:\u003c\/strong\u003e 4 portas Fast Ethernet, 2 slots SFP.\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cstrong\u003eTemperatura de Operação:\u003c\/strong\u003e Projetado para operar em uma ampla faixa de temperatura adequada para aplicações industriais.\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cstrong\u003eGerenciamento:\u003c\/strong\u003e Gerenciado por interface web, CLI e SNMP para fácil configuração e monitoramento de rede.\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cstrong\u003eFator de Forma:\u003c\/strong\u003e Design robusto e compacto adequado para ambientes industriais com restrição de espaço.\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\u003cp\u003eVocê pode verificar a aba relacionada para a folha de dados do Cisco IE-2000-4TS-G-L.\u003c\/p\u003e","brand":"Cisco","offers":[{"title":"Default Title","offer_id":48958407573760,"sku":"IE-2000-4TS-G-L-NEW","price":1270.9,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0388\/5331\/2557\/files\/IE-2000-4TS-G-L_1_f976b3ea-79d5-45a0-85e4-a6048768aef4.webp?v=1783447423","url":"https:\/\/alotechparts.com\/pt-br\/products\/cisco-ie-2000-4ts-g-l-switch","provider":"Alo Tech Solutions","version":"1.0","type":"link"}