{"product_id":"bosch-mic-alm-was-24-mic7000-alarm-washer-interface-24vac","title":"Bosch MIC-ALM-WAS-24 MIC7000 ALARM-WASHER INTERFACE, 24VAC","description":"\u003cp\u003eMIC7000 ALARM-WASHER INTERFACE, 24VAC\u003c\/p\u003e \u003cul\u003e \u003cli\u003eProvides alarm and washer interface connections for MIC7000 cameras\u003c\/li\u003e \u003c\/ul\u003e \u003cul\u003e \u003cli\u003eImpact-resistant polycarbonate enclosure rated to IP67 and NEMA 4X\u003c\/li\u003e \u003c\/ul\u003e \u003cul\u003e \u003cli\u003eWatertight cable glands included\u003c\/li\u003e \u003c\/ul\u003e \u003cul\u003e \u003cli\u003ePush button to activate\/test connected washer pump\u003c\/li\u003e \u003c\/ul\u003e \u003cdiv class=\"row\"\u003e \u003cdiv class=\"col-sm-12 col-md-7\"\u003e \u003ch4\u003eKey Specifications\u003c\/h4\u003e \u003c\/div\u003e \u003cdiv class=\"col-sm-12 col-md-5 text-right bt-tech-spec-actions-top\"\u003e \u003ch4 data-index=\"1\"\u003e\u003ca class=\"A-Link A-Link--button\" href=\"https:\/\/resources-boschsecurity-cdn.azureedge.net\/public\/documents\/MIC_ALM_WAS_24_Data_sheet_enUS_17576798347.pdf\" target=\"_blank\"\u003e\u003cspan class=\"A-Link__link A-Link__link--button\"\u003e\u003cspan class=\"A-Link__linkText\"\u003eFull specifications\u003c\/span\u003e\u003c\/span\u003e\u003c\/a\u003e\u003c\/h4\u003e \u003c\/div\u003e \u003c\/div\u003e \u003ctable class=\"bt-table-100 bt-table-cols-2\"\u003e \u003ctbody\u003e \u003ctr\u003e \u003ctd\u003eInput Voltage\u003c\/td\u003e \u003ctd\u003e24 VAC\/VDC, 50\/60 Hz\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003ePower Consumption\u003c\/td\u003e \u003ctd\u003e5 A maximum\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eCurrent Consumption\u003c\/td\u003e \u003ctd\u003e1 A\u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e \u003c\/table\u003e \u003ctable class=\"bt-table-100 bt-table-cols-2\"\u003e \u003ctbody\u003e \u003ctr\u003e \u003ctd\u003eProtection on RS-485\u003c\/td\u003e \u003ctd\u003ePeak current 10 A, peak power 300 W (8\/20 μ)\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eProtection on Alarm Inputs\u003c\/td\u003e \u003ctd\u003ePeak current 17 A, peak power 300 W (8\/20 μ)\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eProtection on Alarm Outputs\u003c\/td\u003e \u003ctd\u003ePeak current 2 A, peak power 300 W (8\/20 μ)\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eProtection on Relay Outputs\u003c\/td\u003e \u003ctd\u003ePeak current 7.3 A, peak power 600 W (10\/1000 μ)\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eProtection on Power Input (Camera)\u003c\/td\u003e \u003ctd\u003ePeak current 7.3 A, peak power 600 W (10\/1000 μ)\u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e \u003c\/table\u003e \u003ctable class=\"bt-table-100 bt-table-cols-2\"\u003e \u003ctbody\u003e \u003ctr\u003e \u003ctd\u003eLEDs\u003c\/td\u003e \u003ctd\u003eRed LED (ON indicates power on)Green LEDs (blinking indicates activation for each alarm input)Yellow LED (blinking indicates active communication between the MIC-ALM-WAS-24 and the MIC7000 camera)\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eCommunications Protocol\u003c\/td\u003e \u003ctd\u003eProprietary half-duplex RS-485, 57600 baud\u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e \u003c\/table\u003e \u003ctable class=\"bt-table-100 bt-table-cols-2\"\u003e \u003ctbody\u003e \u003ctr\u003e \u003ctd\u003ePower\u003c\/td\u003e \u003ctd\u003e24 VAC ± 10%, 50\/60 Hz\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eAlarm Input\u003c\/td\u003e \u003ctd\u003e4 normal dry contacts (selectable N.O.\/N.C.)2 monitored tamper alarm inputs, 2.2K ohm end-of-line termination\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eAlarm Output\u003c\/td\u003e \u003ctd\u003e3 open collector outputs, 32 VDC, 150 mA\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eRelay Output\u003c\/td\u003e \u003ctd\u003e1 dry contact relay, 250 V, 5 A (for washer pump)\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eAlarm\/Data\u003c\/td\u003e \u003ctd\u003e3-wire RS-485 (to external alarm\/washer accessory unit) up to 100 m\u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e \u003c\/table\u003e \u003ctable class=\"bt-table-100 bt-table-cols-2\"\u003e \u003ctbody\u003e \u003ctr\u003e \u003ctd\u003eIngress Protection Rating\/ Standard\u003c\/td\u003e \u003ctd\u003eIP67NEMA 4, 4X, 6, 12, 13\u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e \u003c\/table\u003e \u003ctable class=\"bt-table-100 bt-table-cols-2\"\u003e \u003ctbody\u003e \u003ctr\u003e \u003ctd\u003eOperating Temperature\u003c\/td\u003e \u003ctd\u003e-40 °C to +60 °C (-40 °F to +140 °F)\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eCold Start-up Temperature\u003c\/td\u003e \u003ctd\u003e-40 °C (-40 °F) (Requires 60 minute warm-up prior to operation)\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eStorage Temperature\u003c\/td\u003e \u003ctd\u003e-40 °C to +70 °C (-40 °F to +158 °F)\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eHumidity\u003c\/td\u003e \u003ctd\u003e0-100%\u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e \u003c\/table\u003e","brand":"Bosch","offers":[{"title":"Default Title","offer_id":48892711665920,"sku":"MIC-ALM-WAS-24","price":483.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0388\/5331\/2557\/files\/ProductPhoto_Web_all_16562172427__22400.1604534511.1280.1280.png?v=1782487766","url":"https:\/\/alotechparts.com\/pt-br\/products\/bosch-mic-alm-was-24-mic7000-alarm-washer-interface-24vac","provider":"Alo Tech Solutions","version":"1.0","type":"link"}