{"product_id":"zac-40-siemens-40w-zone-amplifier-card-for-cerberus-pro-modular-fire-alarm-systems","title":"ZAC-40 | Siemens 40W Zone Amplifier Card for Cerberus PRO Modular Fire Alarm Systems","description":"\u003ch4\u003eDescription \u003c\/h4\u003e\n\u003cp data-start=\"144\" data-end=\"396\"\u003eThe Siemens ZAC-40 is a 40-watt Zone Amplifier Card designed for use with Cerberus PRO Modular fire alarm panels. It functions as both an amplifier and speaker-zone interface, providing high-quality audio signal distribution across up to eight digital audio channels. The unit supports 25VRMS or 70VRMS power-limited operation, ensuring reliable performance in supervised voice evacuation and notification systems.\u003c\/p\u003e\n\u003cp data-start=\"284\" data-end=\"574\" class=\"\"\u003e \u003c\/p\u003e\n\u003cp data-start=\"284\" data-end=\"574\" class=\"\"\u003e \u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications \u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNew\/Never Used Surplus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFire Alarm Components\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eZAC-40\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSubcategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eZone Amplifier Card\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Power\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e40 Watts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage Levels\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e25VRMS or 70VRMS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAudio Channels Supported\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUp to 8 (Digital Audio Bus via DAC-NET)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWiring Styles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStyle Y, Style Z, Split-Zone (A\/B)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSupervision\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFull amplifier and speaker line supervision\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnection Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePlug-in card for CC-2 or CC-5 Card Cage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCompatibility\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCerberus PRO Modular Fire Alarm Systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAudio Interface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eASI (Audio Serial Interface)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAuxiliary Input\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLocal audio input supported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eExpansion Capability\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCompatible with EBA2004-A1 booster amplifier\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCertifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUL864 \u0026amp; CAN\/ULC-S576 Listed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePower-limited circuit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e13 × 8 × 3 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eInformation About \u003cmeta charset=\"utf-8\"\u003e \u003cspan data-sheets-root=\"1\"\u003eZAC-40\u003c\/span\u003e\n\u003c\/h4\u003e\n\u003cp\u003eThe ZAC-40 is a plug-in amplifier module that installs directly into the Siemens CC-5 or CC-2 card cage, offering seamless integration with Cerberus PRO Modular fire alarm control systems. It supports Style Y, Z, or split-zone (A\/B) wiring configurations and maintains full supervision for functionality and speaker line integrity. Capable of amplifying any of the eight digital-audio channels from the DAC-NET Digital Audio Card via the ASI (Audio Serial Interface) bus, the ZAC-40 provides flexible zone assignment and high-efficiency sound output. The amplifier can also function as a bulk amplifier feeding high-level audio to ZIC or HCP components, or expand coverage using the EBA2004-A1 booster amplifier.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eHigh-Power Output: Provides 40 watts of supervised audio amplification for voice communication and notification.\u003c\/li\u003e\n\u003cli\u003eSelectable Voltage Levels: Operates at either 25VRMS or 70VRMS for flexible system compatibility.\u003c\/li\u003e\n\u003cli\u003eMulti-Zone Support: Handles up to eight digital audio channels via the DAC-NET interface.\u003c\/li\u003e\n\u003cli\u003eSupervised Operation: Constantly monitors amplifier functionality and speaker line status.\u003c\/li\u003e\n\u003cli\u003eFlexible Wiring Options: Supports Style Y, Z, and A\/B split-zone wiring configurations.\u003c\/li\u003e\n\u003cli\u003eCompact Plug-In Design: Mounts easily into Siemens CC-2 or CC-5 card cages for modular installation.\u003c\/li\u003e\n\u003cli\u003eExpandable System Design: Compatible with EBA2004-A1 booster amplifiers for additional audio zones.\u003c\/li\u003e\n\u003cli\u003eUL864 \u0026amp; ULC Certified: Meets strict fire alarm and life safety system standards.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe ZAC-40 delivers the reliability and precision required for advanced voice evacuation, emergency notification, and fire alarm communication systems.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":49105130553600,"sku":"ZAC-40","price":807.03,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0388\/5331\/2557\/files\/PR-F1P1-7903.jpg?v=1785540941","url":"https:\/\/alotechparts.com\/products\/zac-40-siemens-40w-zone-amplifier-card-for-cerberus-pro-modular-fire-alarm-systems","provider":"Alo Tech Solutions","version":"1.0","type":"link"}