{"product_id":"y8610u4001-honeywell-intermittent-pilot-retrofit-kit-naturallp-gas-24vac-150k-btu","title":"Y8610U4001 | Honeywell Intermittent Pilot Retrofit Kit (Natural\/LP Gas, 24VAC, 150k BTU)","description":"\u003ch4\u003eDescription \u003c\/h4\u003e\n\u003cp data-start=\"144\" data-end=\"396\"\u003eThe Honeywell Y8610U4001 Intermittent Pilot Retrofit Kit is a universal conversion kit that replaces standing pilot ignition systems with an energy-efficient intermittent pilot ignition. Designed for natural or LP gas applications up to 150,000 BTU\/hr, it ensures safe, reliable ignition sequencing and automatic flame monitoring for furnaces, boilers, and other gas-fired heating appliances.\u003c\/p\u003e\n\u003cp data-start=\"284\" data-end=\"574\" class=\"\"\u003e \u003c\/p\u003e\n\u003cp data-start=\"284\" data-end=\"574\" class=\"\"\u003e \u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications \u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNew\/Never Used Surplus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHoneywell \/ Resideo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eControls \u0026amp; Indicators\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eY8610U4001\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSubcategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eControl Accessory\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSystem Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIntermittent Pilot Retrofit Kit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStanding-to-intermittent pilot conversion for gas heating appliances\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eGas Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNatural Gas or LP (Propane)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e150,000 BTU\/hr\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eControl Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24 VAC, 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIgnition Source\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eInternal high-voltage spark generator\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIgnition Sequence\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eContinuous retry with 6-minute delay between trials\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIgnition Trial Time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15 or 90 seconds (selectable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLockout Timing\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15 or 90 seconds\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePre-Purge Time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 or 30 seconds\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFlame Sense\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSingle or dual rod\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFlame Failure Response\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 seconds maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eGas Valve Model\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eVR8204A2142 dual valve (1\/2\" x 1\/2\" NPT)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax Valve Load\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1A pilot, 2A main @ 24 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTypical Pressure Setting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3.5\" W.C. outlet pressure\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient Temperature Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e–40°F to +165°F (–40°C to +74°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSafety Standard Compliance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eANSI Z21.71, CSA Certified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTypical Use\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFurnaces, boilers, unit heaters, and gas-fired atmospheric appliances\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIncluded Components\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGas valve, ignition module, pilot burner assembly, wiring harness, LP conversion kit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3.9\" H × 5.4\" W × 2.6\" D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3.20 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4\u003e\u003cbr\u003e\u003c\/h4\u003e\n\u003ch4\u003e\u003cbr\u003e\u003c\/h4\u003e\n\u003ch4\u003eInformation About \u003cspan data-sheets-root=\"1\"\u003eY8610U4001\u003c\/span\u003e\n\u003c\/h4\u003e\n\u003cp\u003eThe Y8610U4001 kit includes all components required to convert conventional standing pilot systems into modern intermittent pilot systems, improving energy efficiency and reliability. It features the S8610U3009 ignition module and VR8204A2142 dual gas valve, providing electronic control of ignition, flame sense, and safety shutoff. The module operates on 24 VAC power and supports both single-rod and dual-rod flame sensing. Designed for retrofit use, it continuously retries ignition after failed attempts, shutting off gas safely between trials. This kit meets ANSI Z21.71 standards for automatic intermittent pilot ignition systems used in central furnaces and boilers.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eUniversal Retrofit Kit: Converts standing pilot systems to intermittent pilot operation.\u003c\/li\u003e\n\u003cli\u003eDual Gas Compatibility: Works with natural gas or LP (propane) systems up to 150,000 BTU\/hr.\u003c\/li\u003e\n\u003cli\u003eComplete Assembly: Includes ignition module, gas valve, pilot burner, wiring harness, and hardware.\u003c\/li\u003e\n\u003cli\u003eContinuous Retry Ignition: Automatically repeats ignition attempts every 6 minutes until flame established.\u003c\/li\u003e\n\u003cli\u003eIntegrated Safety Shutoff: Provides 100% pilot gas shutoff if ignition fails.\u003c\/li\u003e\n\u003cli\u003eSmart Ignition Control: S8610U3009 module manages sequencing, pre-purge, and flame sensing.\u003c\/li\u003e\n\u003cli\u003eFast Flame Response: Detects flame failure within 2 seconds for rapid safety shutdown.\u003c\/li\u003e\n\u003cli\u003eSelectable Trial Times: Offers 15 or 90-second ignition trial settings with lockout options.\u003c\/li\u003e\n\u003cli\u003e24 VAC Operation: Standard low-voltage control compatible with most thermostats.\u003c\/li\u003e\n\u003cli\u003eLED Status Indicators: Dual LEDs show flame strength and system diagnostics.\u003c\/li\u003e\n\u003cli\u003eRugged Reliability: Designed for furnaces, boilers, unit heaters, and other atmospheric appliances.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe Y8610U4001 delivers modern electronic ignition performance and enhanced safety for retrofit heating systems.\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":49105138614528,"sku":"Y8610U4001","price":689.43,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0388\/5331\/2557\/files\/Y8610U-c11-6.jpg?v=1785541097","url":"https:\/\/alotechparts.com\/products\/y8610u4001-honeywell-intermittent-pilot-retrofit-kit-naturallp-gas-24vac-150k-btu","provider":"Alo Tech Solutions","version":"1.0","type":"link"}