{"product_id":"xpsaxe5120p-schneider-electric-preventa-safety-relay-for-emergency-stop-circuits","title":"XPSAXE5120P | Schneider Electric Preventa Safety Relay for Emergency Stop Circuits","description":"\u003ch4\u003eDescription \u003c\/h4\u003e\n\u003cp data-start=\"21\" data-end=\"474\"\u003eThe Schneider Electric XPSAXE5120P is a configurable safety relay designed to monitor emergency stop circuits and safety interlocks in industrial machinery. It provides reliable safety outputs for machine stop functions and is commonly used in applications requiring compliance with international functional safety standards. This module supports dual-channel inputs to ensure controlled shutdown and operator protection.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications \u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNew\/Never Used Surplus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSafety Relays\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eXPSAXE5120P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSubcategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEmergency Stop Safety Relays\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePreventa XPS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSupply Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDual-channel safety inputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSafety Outputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3 NO safety contacts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAuxiliary Output\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 NC signaling contact\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReset Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMonitored manual reset\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Method\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDIN rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSafety Level\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCategory 4 \/ PL e \/ SIL 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStandards Compliance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEN ISO 13849-1, IEC 62061, IEC 61508\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e–25 °C to +55 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eApprox. 0.25 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003e\u003c\/h4\u003e\n\u003ch4\u003eInformation About \u003cmeta charset=\"utf-8\"\u003eXPSAXE5120P\u003c\/h4\u003e\n\u003cp data-start=\"503\" data-end=\"1065\"\u003eThe XPSAXE5120P is part of Schneider Electric’s Preventa XPS safety relay series, engineered for safeguarding machinery and industrial processes. It features a compact DIN-rail mount design with reinforced isolation and robust internal diagnostics for continuous safety monitoring. The relay is compatible with emergency stop buttons, safety switches, and other electromechanical safety devices used in control panels. Utilizing forced-guided contacts and monitored reset logic, it supports safety architectures up to SIL 3 and Category 4, making it suitable for demanding automation environments.\u003c\/p\u003e\n\u003ch3 data-start=\"1067\" data-end=\"1088\"\u003e\u003cbr\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong data-start=\"1085\" data-end=\"1102\"\u003eKey Features:\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ePreventa XPS Series Module: Designed specifically for machine safety and emergency stop monitoring.\u003c\/li\u003e\n\u003cli\u003eDual-Channel Safety Inputs: Ensures redundancy and fault detection for safety circuits.\u003c\/li\u003e\n\u003cli\u003eMonitored Manual Reset: Prevents unintended restart after safety events.\u003c\/li\u003e\n\u003cli\u003eForced-Guided Relay Contacts: Provides reliable detection of contact welding or failure.\u003c\/li\u003e\n\u003cli\u003eMultiple Safety Outputs: Supports control of safety contactors and machine stop circuits.\u003c\/li\u003e\n\u003cli\u003eDIN-Rail Mounting: Allows straightforward installation in standard control cabinets.\u003c\/li\u003e\n\u003cli\u003eHigh Safety Compliance: Supports Category 4, SIL 3, and PL e safety requirements.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe XPSAXE5120P delivers the reliability and precision required for critical machine safety and emergency stop control in industrial automation systems.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":49105059676416,"sku":"XPSAXE5120P","price":523.32,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0388\/5331\/2557\/files\/files_5ae27bf5-9370-4594-b583-5863e6c0c7ac.jpg?v=1785539083","url":"https:\/\/alotechparts.com\/products\/xpsaxe5120p-schneider-electric-preventa-safety-relay-for-emergency-stop-circuits","provider":"Alo Tech Solutions","version":"1.0","type":"link"}