{"product_id":"xp6-ma-notifier-six-zone-interface-module","title":"XP6-MA | Notifier Six-Zone Interface Module","description":"\u003ch4\u003eDescription \u003c\/h4\u003e\n\u003cp\u003eThe Notifier XP6-MA is a six-zone interface module designed to monitor conventional two-wire detection circuits within addressable fire alarm systems. It supports Class A or Class B wiring and integrates with FlashScan® or CLIP communication protocols.\u003c\/p\u003e\n\u003cp class=\"\" data-end=\"574\" data-start=\"284\"\u003e \u003c\/p\u003e\n\u003cp class=\"\" data-end=\"574\" data-start=\"284\"\u003e \u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications \u003c\/h4\u003e\n\u003ctable style=\"height: 477.219px; width: 100%;\" width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 34.9219px;\"\u003e\n\u003cth class=\"text-left text-body1 text-bold py-10 pr-10 desktop:pr-[10rem] desktop:text-nowrap\" style=\"width: 31.0909%; text-align: left; height: 34.9219px;\"\u003eCondition\u003c\/th\u003e\n\u003ctd class=\"text-left text-body1 py-10 desktop:w-[60%]\" style=\"width: 68.5455%; height: 34.9219px;\"\u003eNew\/Never Used Surplus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 27.4219px;\"\u003e\n\u003cth class=\"text-left text-body1 text-bold py-10 pr-10 desktop:pr-[10rem] desktop:text-nowrap\" style=\"width: 31.0909%; text-align: left; height: 27.4219px;\"\u003eBrand\u003c\/th\u003e\n\u003ctd class=\"text-left text-body1 py-10 desktop:w-[60%]\" style=\"width: 68.5455%; height: 27.4219px;\"\u003e\u003cspan data-sheets-root=\"1\"\u003eNotifier\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 24.4219px;\"\u003e\n\u003cth style=\"width: 31.0909%; text-align: left; height: 24.4219px;\"\u003eCategory\u003c\/th\u003e\n\u003ctd style=\"width: 68.5455%; height: 24.4219px;\"\u003e\n\u003cdiv class=\"mt-1 md:mt-0 column-left basis-2\/4 divide-y divide-rad-gray-10 border-b-[0.0625rem] border-rad-gray-10 md:border-0\"\u003e\n\u003cdiv class=\"flex gap-[1.75rem] md:gap-x-0 xl:gap-x-[1.875rem]\"\u003e\n\u003cdiv class=\"text-body-4 w-full font-light py-5 pl-4 md:py-6 md:pl-6 text-rad-gray-70\"\u003e\n\u003cdiv class=\"max-w-[8rem] break-words\"\u003e\n\u003cspan\u003e\u003c\/span\u003e\u003cspan\u003eSafety Systems\u003c\/span\u003e\u003cbr\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 28.2969px;\"\u003e\n\u003cth style=\"width: 31.0909%; text-align: left; height: 28.2969px;\"\u003ePart Number\u003c\/th\u003e\n\u003ctd style=\"width: 68.5455%; height: 28.2969px;\"\u003e\u003cspan data-sheets-root=\"1\"\u003eXP6-MA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 23.7188px;\"\u003e\n\u003cth style=\"width: 31.0909%; text-align: left; height: 23.7188px;\"\u003e\u003cspan\u003eSubcategory\u003c\/span\u003e\u003c\/th\u003e\n\u003ctd style=\"width: 68.5455%; height: 23.7188px;\"\u003e\u003cspan data-sheets-root=\"1\"\u003e\u003cspan\u003eSafety Relay\u003c\/span\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 33.1875px;\"\u003e\n\u003cth style=\"width: 31.0909%; text-align: left; height: 33.1875px;\"\u003e\u003cspan\u003eInput Circuits\u003c\/span\u003e\u003c\/th\u003e\n\u003ctd style=\"width: 68.5455%; height: 33.1875px;\"\u003e\u003cspan data-sheets-root=\"1\"\u003e\u003cspan\u003e6 Class B or 3 Class A initiating device circuits\u003c\/span\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 26.1875px;\"\u003e\n\u003cth style=\"width: 31.0909%; text-align: left; height: 26.1875px;\"\u003e\u003cspan\u003eCompatible Detectors\u003c\/span\u003e\u003c\/th\u003e\n\u003ctd style=\"width: 68.5455%; height: 26.1875px;\"\u003e\u003cspan data-sheets-root=\"1\"\u003e\u003cspan\u003eOnly listed two-wire detectors\u003c\/span\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 34.1875px;\"\u003e\n\u003cth style=\"width: 31.0909%; text-align: left; height: 34.1875px;\"\u003eCommunication Protocol\u003c\/th\u003e\n\u003ctd style=\"width: 68.5455%; height: 34.1875px;\"\u003eFlashScan® or CLIP\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003cth style=\"width: 31.0909%; text-align: left; height: 39.1875px;\"\u003eAddressing Method\u003c\/th\u003e\n\u003ctd style=\"width: 68.5455%; height: 39.1875px;\"\u003eRotary decimal switches\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 27.5938px;\"\u003e\n\u003cth style=\"width: 31.0909%; text-align: left; height: 27.5938px;\"\u003eStatus Indication\u003c\/th\u003e\n\u003ctd style=\"width: 68.5455%; height: 27.5938px;\"\u003ePanel-controlled bicolor LEDs per circuit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 24.5938px;\"\u003e\n\u003cth style=\"width: 31.0909%; text-align: left; height: 24.5938px;\"\u003ePower Supply\u003c\/th\u003e\n\u003ctd style=\"width: 68.5455%; height: 24.5938px;\"\u003eExternal, shared among circuits (supervised)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 26.1875px;\"\u003e\n\u003cth style=\"width: 31.0909%; text-align: left; height: 26.1875px;\"\u003eUnused Circuits\u003c\/th\u003e\n\u003ctd style=\"width: 68.5455%; height: 26.1875px;\"\u003eUp to 2 may be disabled\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 26.1875px;\"\u003e\n\u003cth style=\"width: 31.0909%; text-align: left; height: 26.1875px;\"\u003eWiring Terminals\u003c\/th\u003e\n\u003ctd style=\"width: 68.5455%; height: 26.1875px;\"\u003ePlug-in type, accepts 12–18 AWG (3.1–0.78 mm²)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 32.1875px;\"\u003e\n\u003cth style=\"width: 31.0909%; text-align: left; height: 32.1875px;\" class=\"text-left text-body1 text-bold py-10 pr-10 desktop:pr-[10rem] desktop:text-nowrap\"\u003eMounting Options\u003cbr\u003e\n\u003c\/th\u003e\n\u003ctd style=\"width: 68.5455%; height: 32.1875px;\" class=\"text-left text-body1 py-10 desktop:w-[60%]\"\u003eBB-XP, CHS-6 in CAB-3\/4\/BB-25\/EQ cabinet series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 24.1875px;\"\u003e\n\u003cth style=\"width: 31.0909%; text-align: left; height: 24.1875px;\"\u003eOperation Modes\u003c\/th\u003e\n\u003ctd style=\"width: 68.5455%; height: 24.1875px;\"\u003eCLIP or FlashScan-compatible panels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 24.1875px;\"\u003e\n\u003cth style=\"width: 31.0909%; text-align: left; height: 24.1875px;\"\u003eDimensions\u003c\/th\u003e\n\u003ctd style=\"width: 68.5455%; height: 24.1875px;\"\u003e6.80 × 5.80 × 1.25 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 20.5625px;\"\u003e\n\u003cth style=\"width: 31.0909%; text-align: left; height: 20.5625px;\"\u003eWeight\u003c\/th\u003e\n\u003ctd style=\"width: 68.5455%; height: 20.5625px;\"\u003e\u003cspan\u003e0.2 lbs\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003cspan style=\"font-size: 0.875rem;\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eInformation About \u003cspan data-sheets-root=\"1\"\u003eXP6-MA\u003c\/span\u003e\n\u003c\/h4\u003e\n\u003cp\u003eThe XP6-MA enables seamless integration of conventional two-wire detection zones into Notifier’s intelligent fire alarm systems. Each module supports six Class B (or three Class A) initiating device circuits, making it suitable for retrofits or hybrid systems where existing conventional devices are retained. All circuits operate via a common signaling line circuit (SLC) and share a supervised external power supply and ground, ensuring unified status reporting and reliable supervision.\u003c\/p\u003e\n\u003cp\u003eThe XP6-MA reports three status conditions—normal, open, and alarm—for each detection zone, and features panel-controlled bicolor LEDs for visual indication per point. Up to two unused circuits can be selectively disabled, and addressing is done via rotary switches for easy configuration. Installation is flexible, supporting mounting in BB-XP, CHS-6 chassis, or CAB\/EQ cabinet series. All terminal blocks are removable for quick wiring, and the unit is compatible with FlashScan or CLIP operation modes.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSix Supervised Input Zones: Supports six Class B or three Class A initiating circuits for conventional detectors.\u003c\/li\u003e\n\u003cli\u003eCommon SLC Bus Integration: Shares a single SLC address bus for streamlined wiring and communication.\u003c\/li\u003e\n\u003cli\u003eStatus Reporting: Monitors and reports normal, alarm, or open conditions per circuit to the FACP.\u003c\/li\u003e\n\u003cli\u003eRotary Addressing: Simplifies configuration with panel-compatible address switches.\u003c\/li\u003e\n\u003cli\u003eFlashScan®\/CLIP Operation: Fully compatible with intelligent panels using either communication protocol.\u003c\/li\u003e\n\u003cli\u003ePanel-Controlled LEDs: Provides per-zone visual status via dual-color panel-controlled indicators.\u003c\/li\u003e\n\u003cli\u003eUnused Circuit Disable Option: Allows deactivation of up to two unused circuits for streamlined addressing.\u003c\/li\u003e\n\u003cli\u003eModular Mounting Options: Fits in BB-XP cabinet or up to six modules on CHS-6 chassis in CAB-3, CAB-4, BB-25, or EQ cabinets.\u003c\/li\u003e\n\u003cli\u003ePlug-in Terminal Blocks: Accepts 12–18 AWG wiring for fast installation and service.\u003c\/li\u003e\n\u003cli\u003eUL-Listed Compatibility: Works only with two-wire detectors specifically listed for use with XP6 modules.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe XP6-MA provides a reliable and flexible bridge between conventional detection zones and modern addressable fire alarm systems with full supervision and streamlined installation.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Notifier","offers":[{"title":"Default Title","offer_id":49105315463424,"sku":"XP6-MA","price":2174.13,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0388\/5331\/2557\/files\/963d88c957e846dd8ec523f93c3ddbab.jpg?v=1785544798","url":"https:\/\/alotechparts.com\/products\/xp6-ma-notifier-six-zone-interface-module","provider":"Alo Tech Solutions","version":"1.0","type":"link"}