{"product_id":"xp10-ma-notifier-ten-input-intelligent-monitor-module-for-fire-alarm-control-systems","title":"XP10-MA | Notifier Ten Input Intelligent Monitor Module for Fire Alarm Control Systems","description":"\u003ch4\u003eDescription \u003c\/h4\u003e\n\u003cp data-end=\"396\" data-start=\"144\"\u003eThe Notifier XP10-MA Ten Input Monitor Module is an intelligent interface device that enables connection of multiple initiating circuits to a Notifier intelligent fire alarm control panel. It provides ten supervised input channels for monitoring contact devices such as pull stations, waterflow switches, and conventional detectors.\u003c\/p\u003e\n\u003cp class=\"\" data-end=\"574\" data-start=\"284\"\u003e \u003c\/p\u003e\n\u003cp class=\"\" data-end=\"574\" data-start=\"284\"\u003e \u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications \u003c\/h4\u003e\n\u003ctable style=\"width: 100%; height: 343.095px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 10px;\"\u003e\n\u003ctd style=\"width: 32.5912%;\"\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 67.1895%;\"\u003eNew\/Never Used Surplus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 32.5912%;\"\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 67.1895%;\"\u003eNotifier\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 32.5912%;\"\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 67.1895%;\"\u003eFire Alarm Equipment\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 32.5912%;\"\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 67.1895%;\"\u003eXP10-MA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 32.5912%;\"\u003e\u003cstrong\u003eSubcategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 67.1895%;\"\u003eInput Monitor Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 32.5912%;\"\u003e\u003cstrong\u003eInput Channels\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 67.1895%;\"\u003e10 supervised initiating device circuits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 32.5912%;\"\u003e\u003cstrong\u003eVoltage Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 67.1895%;\"\u003e15–32 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 32.5912%;\"\u003e\u003cstrong\u003eStandby Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 67.1895%;\"\u003e3.8 mA (average)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 32.5912%;\"\u003e\u003cstrong\u003eAlarm Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 67.1895%;\"\u003e68 mA (maximum)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 32.5912%;\"\u003e\u003cstrong\u003eWiring Configuration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 67.1895%;\"\u003eClass A (Style D) or Class B (Style B)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 32.5912%;\"\u003e\u003cstrong\u003eCommunication Interface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 67.1895%;\"\u003eSLC loop – Notifier intelligent protocol\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 32.5912%;\"\u003e\u003cstrong\u003eIndicators\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 67.1895%;\"\u003eLED status for communication, alarm, and trouble\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 32.5912%;\"\u003e\u003cstrong\u003eOperating Temperature Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 67.1895%;\"\u003e32°F to 120°F (0°C to 49°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 32.5912%;\"\u003e\u003cstrong\u003eHumidity Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 67.1895%;\"\u003eUp to 93% RH, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 32.5912%;\"\u003e\u003cstrong\u003eMounting Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 67.1895%;\"\u003eCabinet or chassis mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 32.5912%;\"\u003e\u003cstrong\u003eHousing Material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 67.1895%;\"\u003ePlastic enclosure\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 32.5912%;\"\u003e\u003cstrong\u003eCompliance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 67.1895%;\"\u003eUL Listed; NFPA 72 compliant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 32.5912%;\"\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 67.1895%;\"\u003e6.8” H × 5.8” W × 1.0” D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 32.5912%;\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 67.1895%;\"\u003e0.6 lb (0.27 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eInformation About XP10-MA\u003c\/h4\u003e\n\u003cp\u003eThe XP10-MA is part of Notifier’s intelligent module line, designed to expand the input capacity of ONYX Series and other compatible fire alarm control panels. It monitors up to ten independent initiating device circuits, each individually addressable through the system’s SLC (Signaling Line Circuit). Supporting both Class A (Style D) and Class B (Style B) wiring, the XP10-MA ensures flexible installation in a variety of system layouts. Compact and easily mountable, this module maintains consistent communication with the panel for real-time status updates, enhancing system reliability and fault tolerance.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eTen Supervised Inputs: Monitors up to ten independent initiating device circuits.\u003c\/li\u003e\n\u003cli\u003eIntelligent Addressing: Each input is individually addressable for precise zone identification.\u003c\/li\u003e\n\u003cli\u003eClass A\/B Wiring Support: Compatible with both Style D and Style B circuits.\u003c\/li\u003e\n\u003cli\u003eNotifier System Integration: Works seamlessly with ONYX Series intelligent control panels.\u003c\/li\u003e\n\u003cli\u003eLED Indicators: Provides visible feedback for communication, alarm, and fault conditions.\u003c\/li\u003e\n\u003cli\u003eLow Power Consumption: Operates efficiently with 3.8 mA standby and 68 mA alarm current.\u003c\/li\u003e\n\u003cli\u003eCompact Design: Fits neatly within standard electrical enclosures for easy installation.\u003c\/li\u003e\n\u003cli\u003eUL\/NFPA Compliant: Meets recognized standards for intelligent fire detection systems.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe XP10-MA delivers the reliability and precision required for advanced input monitoring in addressable fire alarm systems.\u003c\/p\u003e","brand":"Notifier","offers":[{"title":"Default Title","offer_id":49105152049408,"sku":"XP10-MA","price":1971.27,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0388\/5331\/2557\/files\/NewProject_c985c53a-91ef-405a-bfec-b511d276c6d7.jpg?v=1785541403","url":"https:\/\/alotechparts.com\/products\/xp10-ma-notifier-ten-input-intelligent-monitor-module-for-fire-alarm-control-systems","provider":"Alo Tech Solutions","version":"1.0","type":"link"}