{"product_id":"xp10-m-notifier-ten-input-monitor-module","title":"XP10-M | Notifier Ten Input Monitor Module","description":"\u003ch4\u003eDescription \u003c\/h4\u003e\n\u003cp\u003eThe XP10-M is a ten-input addressable monitor module designed for use with Notifier fire alarm control panels. It monitors multiple initiating devices with high efficiency, minimizing system wiring while maintaining independent supervision for each input.\u003c\/p\u003e\n\u003cp data-start=\"284\" data-end=\"574\" class=\"\"\u003e \u003c\/p\u003e\n\u003cp data-start=\"284\" data-end=\"574\" class=\"\"\u003e \u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications \u003c\/h4\u003e\n\u003ctable width=\"100%\" style=\"height: 539.219px; width: 100%;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 34.9219px;\"\u003e\n\u003cth style=\"width: 31.0909%; text-align: left; height: 34.9219px;\" class=\"text-left text-body1 text-bold py-10 pr-10 desktop:pr-[10rem] desktop:text-nowrap\"\u003eCondition\u003c\/th\u003e\n\u003ctd style=\"width: 68.5455%; height: 34.9219px;\" class=\"text-left text-body1 py-10 desktop:w-[60%]\"\u003eNew\/Never Used Surplus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 27.4219px;\"\u003e\n\u003cth style=\"width: 31.0909%; text-align: left; height: 27.4219px;\" class=\"text-left text-body1 text-bold py-10 pr-10 desktop:pr-[10rem] desktop:text-nowrap\"\u003eBrand\u003c\/th\u003e\n\u003ctd style=\"width: 68.5455%; height: 27.4219px;\" class=\"text-left text-body1 py-10 desktop:w-[60%]\"\u003e\u003cspan data-sheets-root=\"1\"\u003eNotifier\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 24.4219px;\"\u003e\n\u003cth style=\"width: 31.0909%; text-align: left; height: 24.4219px;\"\u003eCategory\u003c\/th\u003e\n\u003ctd style=\"width: 68.5455%; height: 24.4219px;\"\u003e\n\u003cdiv class=\"mt-1 md:mt-0 column-left basis-2\/4 divide-y divide-rad-gray-10 border-b-[0.0625rem] border-rad-gray-10 md:border-0\"\u003e\n\u003cdiv class=\"flex gap-[1.75rem] md:gap-x-0 xl:gap-x-[1.875rem]\"\u003e\n\u003cdiv class=\"text-body-4 w-full font-light py-5 pl-4 md:py-6 md:pl-6 text-rad-gray-70\"\u003e\n\u003cdiv class=\"max-w-[8rem] break-words\"\u003e\n\u003cspan\u003e\u003c\/span\u003eFire Alarm System Components\u003cbr\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 28.2969px;\"\u003e\n\u003cth style=\"width: 31.0909%; text-align: left; height: 28.2969px;\"\u003ePart Number\u003c\/th\u003e\n\u003ctd style=\"width: 68.5455%; height: 28.2969px;\"\u003e\u003cspan data-sheets-root=\"1\"\u003eXP10-M\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 23.7188px;\"\u003e\n\u003cth style=\"width: 31.0909%; text-align: left; height: 23.7188px;\"\u003e\u003cspan\u003eSubcategory\u003c\/span\u003e\u003c\/th\u003e\n\u003ctd style=\"width: 68.5455%; height: 23.7188px;\"\u003e\u003cspan data-sheets-root=\"1\"\u003e\u003cspan\u003eInput Monitor Modules\u003c\/span\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003cth style=\"width: 31.0909%; text-align: left; height: 39.1875px;\"\u003e\u003cspan\u003eNormal Operating Voltage\u003c\/span\u003e\u003c\/th\u003e\n\u003ctd style=\"width: 68.5455%; height: 39.1875px;\"\u003e\u003cspan data-sheets-root=\"1\"\u003e\u003cspan\u003e15–32 VDC\u003c\/span\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003cth style=\"width: 31.0909%; text-align: left; height: 39.1875px;\"\u003e\u003cspan\u003eStandby Current\u003c\/span\u003e\u003c\/th\u003e\n\u003ctd style=\"width: 68.5455%; height: 39.1875px;\"\u003e\u003cspan data-sheets-root=\"1\"\u003e\u003cspan\u003e3.75 mA at 24V\u003c\/span\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 32.1875px;\"\u003e\n\u003cth style=\"width: 31.0909%; text-align: left; height: 32.1875px;\"\u003eAlarm Current\u003c\/th\u003e\n\u003ctd style=\"width: 68.5455%; height: 32.1875px;\"\u003e55 mA (all LEDs on)\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003cth style=\"width: 31.0909%; text-align: left; height: 39.1875px;\"\u003eOperating Temperature Range\u003c\/th\u003e\n\u003ctd style=\"width: 68.5455%; height: 39.1875px;\"\u003e32°F to 120°F (0°C to 49°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 27.5938px;\"\u003e\n\u003cth style=\"width: 31.0909%; text-align: left; height: 27.5938px;\"\u003eHumidity\u003c\/th\u003e\n\u003ctd style=\"width: 68.5455%; height: 27.5938px;\"\u003e10–85% RH, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003cth style=\"width: 31.0909%; text-align: left; height: 19.5938px;\"\u003eDimensions\u003c\/th\u003e\n\u003ctd style=\"width: 68.5455%; height: 19.5938px;\"\u003e6.8″H × 5.8″W × 1.25″D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 26.1875px;\"\u003e\n\u003cth style=\"width: 31.0909%; text-align: left; height: 26.1875px;\"\u003eWire Gauge\u003c\/th\u003e\n\u003ctd style=\"width: 68.5455%; height: 26.1875px;\"\u003e12–18 AWG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003cth style=\"width: 31.0909%; text-align: left; height: 39.1875px;\"\u003eMax SLC Wiring Resistance\u003c\/th\u003e\n\u003ctd style=\"width: 68.5455%; height: 39.1875px;\"\u003e40 Ohms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003cth class=\"text-left text-body1 text-bold py-10 pr-10 desktop:pr-[10rem] desktop:text-nowrap\" style=\"width: 31.0909%; text-align: left; height: 39.1875px;\"\u003eMax IDC Wiring Resistance\u003cbr\u003e\n\u003c\/th\u003e\n\u003ctd class=\"text-left text-body1 py-10 desktop:w-[60%]\" style=\"width: 68.5455%; height: 39.1875px;\"\u003e1500 Ohms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003cth style=\"width: 31.0909%; text-align: left; height: 39.1875px;\"\u003eMax IDC Voltage\u003c\/th\u003e\n\u003ctd style=\"width: 68.5455%; height: 39.1875px;\"\u003e10.2 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003cth style=\"width: 31.0909%; text-align: left; height: 19.5938px;\"\u003eMax IDC Current\u003c\/th\u003e\n\u003ctd style=\"width: 68.5455%; height: 19.5938px;\"\u003e240 µA per circuit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003cth style=\"width: 31.0909%; text-align: left; height: 19.5938px;\"\u003eCompatible Cabinets\u003c\/th\u003e\n\u003ctd style=\"width: 68.5455%; height: 19.5938px;\"\u003eCHS-6, BB-25, BB-XP, CAB-3\/4 Series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 20.5625px;\"\u003e\n\u003cth style=\"width: 31.0909%; text-align: left; height: 20.5625px;\"\u003eWeight\u003c\/th\u003e\n\u003ctd style=\"width: 68.5455%; height: 20.5625px;\"\u003e\u003cspan\u003e1.1 lbs\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003cspan style=\"font-size: 0.875rem;\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eInformation About \u003cspan data-sheets-root=\"1\"\u003eXP10-M\u003c\/span\u003e\n\u003c\/h4\u003e\n\u003cp\u003eThe XP10-M supports ten supervised input circuits that share a single SLC address for efficient loop usage. The module’s addresses are sequentially assigned, starting from a user-defined point between 01 and 150, with up to two addresses optionally disabled. Each input loop shares common supervisory power and ground but functions independently in terms of signal monitoring and fault detection.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eTen Independent Inputs: Monitors up to 10 initiating devices through supervised input circuits with common SLC connection.\u003c\/li\u003e\n\u003cli\u003eSequential Address Allocation: The first address is user-programmable (01–150), and the module auto-assigns the next nine addresses, ensuring efficient SLC loop management with minimal manual configuration.\u003c\/li\u003e\n\u003cli\u003eCommon Supply Architecture: Uses a shared supervisory supply and ground across all input circuits, simplifying wiring while maintaining signal isolation between inputs.\u003c\/li\u003e\n\u003cli\u003eIntelligent LED Feedback: Each input features a green LED indicator controlled by the fire panel, with selectable modes (blink, latch on, or off) for visual input status at a glance.\u003c\/li\u003e\n\u003cli\u003eLow Standby and Alarm Current Draw: Optimized power usage with 3.75 mA standby at 24V and only 55 mA during full alarm state (all LEDs on), minimizing the impact on system capacity.\u003c\/li\u003e\n\u003cli\u003eCompact and Mountable Design: Fits in multiple enclosure types such as CHS-6, BB-25, BB-XP, and CAB-series cabinets, ideal for centralized and distributed system layouts.\u003c\/li\u003e\n\u003cli\u003eRobust Environmental Range: Operates reliably between 0°C and 49°C (32°F to 120°F) with up to 85% relative humidity (non-condensing), suitable for most building conditions.\u003c\/li\u003e\n\u003cli\u003eHigh Input Resistance Capacity: Supports IDC wiring up to 1500 ohms and IDC current of 240 µA per circuit, enabling long run applications without loss of supervision accuracy.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe XP10-M provides high-density, addressable input monitoring with minimal SLC load, making it ideal for installations where space and efficiency are priorities.\u003c\/p\u003e","brand":"Notifier","offers":[{"title":"Default Title","offer_id":49105316610304,"sku":"XP10-M","price":1977.15,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0388\/5331\/2557\/files\/hbt-fire-XP10-M-primaryimage.jpg?v=1785544829","url":"https:\/\/alotechparts.com\/products\/xp10-m-notifier-ten-input-monitor-module","provider":"Alo Tech Solutions","version":"1.0","type":"link"}