{"product_id":"xnx-utse-nnnnn-honeywell-analytics-universal-gas-transmitter-stainless-steel-npt","title":"XNX-UTSE-NNNNN | Honeywell Analytics Universal Gas Transmitter Stainless Steel ¾″ NPT","description":"\u003ch4\u003eDescription \u003c\/h4\u003e\n\u003cp data-start=\"144\" data-end=\"396\"\u003eThe Honeywell Analytics XNX-UTSE-NNNNN is a universal gas detection transmitter with a stainless-steel enclosure and ¾″ NPT conduit entries, designed for use with electrochemical, catalytic bead, and infrared sensors. It operates on 24 V DC nominal and provides full compatibility with HART, Modbus, and Fieldbus protocols for oxygen and toxic gas monitoring in industrial environments.\u003c\/p\u003e\n\u003cp data-start=\"284\" data-end=\"574\" class=\"\"\u003e \u003c\/p\u003e\n\u003cp data-start=\"284\" data-end=\"574\" class=\"\"\u003e \u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications \u003c\/h4\u003e\n\u003ctable style=\"width: 100%; height: 539.032px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 32.0555%; height: 19.5938px;\"\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 64.6319%; height: 19.5938px;\"\u003eNew\/Never Used Surplus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 32.0555%; height: 19.5938px;\"\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 64.6319%; height: 19.5938px;\"\u003eHoneywell Analytics\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 32.0555%; height: 19.5938px;\"\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 64.6319%; height: 19.5938px;\"\u003eSensors \u0026amp; Switches\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 32.0555%; height: 19.5938px;\"\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 64.6319%; height: 19.5938px;\"\u003eXNX-UTSE-NNNNN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 32.0555%; height: 19.5938px;\"\u003e\u003cstrong\u003eSubcategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 64.6319%; height: 19.5938px;\"\u003eOxygen Sensor \/ Gas Transmitter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 32.0555%; height: 19.5938px;\"\u003e\u003cstrong\u003eOperating Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 64.6319%; height: 19.5938px;\"\u003e16–32 V DC (24 V nominal)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 32.0555%; height: 19.5938px;\"\u003e\u003cstrong\u003ePower Consumption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 64.6319%; height: 19.5938px;\"\u003e6.2–13.2 W depending on sensor type\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 32.0555%; height: 19.5938px;\"\u003e\u003cstrong\u003eSignal Output\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 64.6319%; height: 19.5938px;\"\u003e4–20 mA with HART (source, sink, or isolated)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003ctd style=\"width: 32.0555%; height: 39.1875px;\"\u003e\u003cstrong\u003eOptional Communication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 64.6319%; height: 39.1875px;\"\u003eModbus RTU or FOUNDATION Fieldbus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 32.0555%; height: 19.5938px;\"\u003e\u003cstrong\u003eRelays\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 64.6319%; height: 19.5938px;\"\u003e3 × SPCO (2 Alarm, 1 Fault) @ 250 V AC \/ 5 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 32.0555%; height: 19.5938px;\"\u003e\u003cstrong\u003eCompatible Sensors\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 64.6319%; height: 19.5938px;\"\u003eElectrochemical, Catalytic Bead, Infrared\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 32.0555%; height: 19.5938px;\"\u003e\u003cstrong\u003eDisplay\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 64.6319%; height: 19.5938px;\"\u003eBacklit LCD, magnetic wand interface\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 32.0555%; height: 19.5938px;\"\u003e\u003cstrong\u003eEnclosure Material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 64.6319%; height: 19.5938px;\"\u003ePainted stainless steel (SS316)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 32.0555%; height: 19.5938px;\"\u003e\u003cstrong\u003eConduit Entries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 64.6319%; height: 19.5938px;\"\u003eFive (¾″ NPT)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 32.0555%; height: 19.5938px;\"\u003e\u003cstrong\u003eProtection Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 64.6319%; height: 19.5938px;\"\u003eIP66 \/ NEMA 4X\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 32.0555%; height: 19.5938px;\"\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 64.6319%; height: 19.5938px;\"\u003e–40 °C to +65 °C (–40 °F to +149 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 32.0555%; height: 19.5938px;\"\u003e\u003cstrong\u003eHumidity Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 64.6319%; height: 19.5938px;\"\u003e0–99 % RH (non-condensing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 32.0555%; height: 19.5938px;\"\u003e\u003cstrong\u003ePressure Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 64.6319%; height: 19.5938px;\"\u003e80–120 kPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 32.0555%; height: 19.5938px;\"\u003e\u003cstrong\u003eMounting Options\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 64.6319%; height: 19.5938px;\"\u003eWall or pipe mount (integral lugs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 32.0555%; height: 19.5938px;\"\u003e\u003cstrong\u003eDimensions (H × W × D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 64.6319%; height: 19.5938px;\"\u003e197 × 159 × 114 mm (7.75 × 6.14 × 4.48 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003ctd style=\"width: 32.0555%; height: 39.1875px;\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 64.6319%; height: 39.1875px;\"\u003e≈ 5 lb (2.27 kg, aluminum) \/ 11 lb (5 kg, SS version)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 32.0555%; height: 19.5938px;\"\u003e\u003cstrong\u003eCertification\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 64.6319%; height: 19.5938px;\"\u003eUL \/ CSA \/ ATEX approved\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 32.0555%; height: 19.5938px;\"\u003e\u003cstrong\u003eSensor Connection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 64.6319%; height: 19.5938px;\"\u003eIntrinsically safe, hot-swappable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 32.0555%; height: 19.5938px;\"\u003e\u003cstrong\u003eData Retention\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 64.6319%; height: 19.5938px;\"\u003e3-year real-time clock backup\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eInformation About \u003cspan data-sheets-root=\"1\"\u003eXNX-UTSE-NNNNN\u003c\/span\u003e\n\u003c\/h4\u003e\n\u003cp\u003eThe XNX-UTSE-NNNNN belongs to Honeywell Analytics’ XNX Universal Transmitter series, engineered for flexible integration and high reliability in hazardous area gas detection systems. This model supports multiple sensor technologies—electrochemical for toxic and oxygen gases, catalytic bead for flammable gases, and infrared for hydrocarbons and CO₂ - within one common platform. It includes a backlit LCD display for local indication, magnetic wand non-intrusive operation, and configurable analog or digital communication outputs. Its robust marine-grade stainless-steel housing and IP66 rating allow installation in demanding indoor or outdoor conditions, including explosive atmospheres.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eUniversal Platform: Supports electrochemical, catalytic bead, and infrared gas sensors with auto-recognition capability.\u003c\/li\u003e\n\u003cli\u003eRugged Stainless-Steel Housing: ¾″ NPT threaded, corrosion-resistant design for harsh or marine environments.\u003c\/li\u003e\n\u003cli\u003eAdvanced Communications: Provides 4–20 mA with HART as standard, with optional Modbus RTU or FOUNDATION Fieldbus.\u003c\/li\u003e\n\u003cli\u003eFlexible Outputs: Three configurable relay outputs for alarms and system faults.\u003c\/li\u003e\n\u003cli\u003eComprehensive User Interface: Backlit LCD with multilingual menu, magnetic switch navigation, and visual status icons.\u003c\/li\u003e\n\u003cli\u003eSmart Sensor Technology: Plug-and-play sensor modules with auto-configuration and built-in diagnostics.\u003c\/li\u003e\n\u003cli\u003eHigh Protection Rating: IP66 \/ NEMA 4X enclosure ensures resistance to dust, water, and mechanical impact.\u003c\/li\u003e\n\u003cli\u003eWide Environmental Range: Operates from –40 °C to +65 °C (–40 °F to +149 °F) and up to 99 % RH.\u003c\/li\u003e\n\u003cli\u003eEnhanced Diagnostics: Reflex self-test function verifies sensor integrity and transmitter performance.\u003c\/li\u003e\n\u003cli\u003eSimplified Maintenance: Hot-swappable sensors and non-intrusive calibration minimize downtime.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe XNX-UTSE-NNNNN delivers the reliability and precision required for continuous gas monitoring in industrial and hazardous area applications.\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":49105080287488,"sku":"XNX-UTSE-NNNNN","price":2759.19,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0388\/5331\/2557\/files\/honeywell-sensing-and-safety-technologies-xnx-amae-mhnnn-xnx-amae-mnnnn-xnx-amae-nhnnn-xnx-amae-nnnnn-xnx-amae-rhnnn-496x540.webp?v=1785539650","url":"https:\/\/alotechparts.com\/products\/xnx-utse-nnnnn-honeywell-analytics-universal-gas-transmitter-stainless-steel-npt","provider":"Alo Tech Solutions","version":"1.0","type":"link"}