{"product_id":"wv8870a1008-honeywell-electronic-gas-control-valve","title":"WV8870A1008 | Honeywell Electronic Gas Control Valve","description":"\u003ch4\u003eDescription \u003c\/h4\u003e\n\u003cp data-start=\"144\" data-end=\"396\"\u003eThe Honeywell WV8870A1008 is an electronic gas control valve designed to regulate natural gas flow for heating appliances. It features precise control input ranges, robust environmental tolerance, and compatibility with a variety of gas heating systems.\u003c\/p\u003e\n\u003cp data-start=\"284\" data-end=\"574\" class=\"\"\u003e \u003c\/p\u003e\n\u003cp data-start=\"284\" data-end=\"574\" class=\"\"\u003e \u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications \u003c\/h4\u003e\n\u003ctable style=\"width: 100%;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 23.8005%;\"\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 75.8358%;\"\u003eNew\/Never Used Surplus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 23.8005%;\"\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 75.8358%;\"\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 23.8005%;\"\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 75.8358%;\"\u003eGas Flow Control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 23.8005%;\"\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 75.8358%;\"\u003eWV8870A1008\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 23.8005%;\"\u003e\u003cstrong\u003eSubcategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 75.8358%;\"\u003eGas Control Valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 23.8005%;\"\u003e\u003cstrong\u003eGas Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 75.8358%;\"\u003eNatural Gas\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 23.8005%;\"\u003e\u003cstrong\u003eRegulation Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 75.8358%;\"\u003e30,000 to 85,000 Btuh\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 23.8005%;\"\u003e\u003cstrong\u003eInlet Pressure\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 75.8358%;\"\u003eMax 0.5 PSI (14.0 in. w.c.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 23.8005%;\"\u003e\u003cstrong\u003eBody Pattern\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 75.8358%;\"\u003e90°, 1\/2 in. inlet, 1\/2 in. inverted flare outlet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 23.8005%;\"\u003e\u003cstrong\u003eMounting Position\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 75.8358%;\"\u003eUpright only\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 23.8005%;\"\u003e\u003cstrong\u003eControl Input Voltage Min\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 75.8358%;\"\u003e350 mV DC (open circuit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 23.8005%;\"\u003e\u003cstrong\u003eControl Input Voltage Max\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 75.8358%;\"\u003e850 mV DC (open circuit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 23.8005%;\"\u003e\u003cstrong\u003eAmbient Temperature Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 75.8358%;\"\u003e32°F to 150°F (0°C to 66°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 23.8005%;\"\u003e\u003cstrong\u003eOperating Temperature Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 75.8358%;\"\u003e0°F to 150°F (-18°C to 66°C)*\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 23.8005%;\"\u003e\u003cstrong\u003eStorage Temperature Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 75.8358%;\"\u003e-40°F to 150°F (-40°C to 66°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 23.8005%;\"\u003e\u003cstrong\u003eHumidity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 75.8358%;\"\u003e95% non-condensing at 104°F (40°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 23.8005%;\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 75.8358%;\"\u003e4 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003e\u003cbr\u003e\u003c\/h4\u003e\n\u003ch4\u003eInformation About \u003cspan data-sheets-root=\"1\"\u003eWV8870A1008\u003c\/span\u003e\n\u003c\/h4\u003e\n\u003cp data-end=\"1222\" data-start=\"504\"\u003eThe WV8870A1008 is part of Honeywell’s electronic gas control series, engineered for safe and accurate gas flow regulation in residential and commercial heating systems. It supports a body pattern with a 90-degree configuration, featuring a 1\/2-inch inlet and a 1\/2-inch inverted flare outlet, providing secure and leak-resistant connections. The control unit is capable of accepting millivolt DC input signals within a specific voltage range, allowing integration with compatible heating control systems. Designed for long-term reliability, it withstands a wide range of temperatures, humidity levels, and environmental conditions, ensuring stable performance even in demanding applications.\u003c\/p\u003e\n\u003cp data-end=\"1243\" data-start=\"1224\"\u003e\u003cstrong data-end=\"1241\" data-start=\"1224\"\u003eKey Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-end=\"2370\" data-start=\"1244\"\u003e\n\u003cli data-end=\"1397\" data-start=\"1244\"\u003e\n\u003cp data-end=\"1397\" data-start=\"1246\"\u003e\u003cstrong data-end=\"1284\" data-start=\"1246\"\u003ePrecise gas regulation capability:\u003c\/strong\u003e Designed for natural gas systems with a regulation range from 30,000 to 85,000 Btuh for controlled combustion.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1564\" data-start=\"1398\"\u003e\n\u003cp data-end=\"1564\" data-start=\"1400\"\u003e\u003cstrong data-end=\"1430\" data-start=\"1400\"\u003eStandardized body pattern:\u003c\/strong\u003e 90-degree inlet\/outlet configuration with a 1\/2-inch NPT inlet and 1\/2-inch inverted flare outlet for straightforward installation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1678\" data-start=\"1565\"\u003e\n\u003cp data-end=\"1678\" data-start=\"1567\"\u003e\u003cstrong data-end=\"1598\" data-start=\"1567\"\u003eFlexible mounting position:\u003c\/strong\u003e Designed for upright installation to maintain optimal performance and safety.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1833\" data-start=\"1679\"\u003e\n\u003cp data-end=\"1833\" data-start=\"1681\"\u003e\u003cstrong data-end=\"1705\" data-start=\"1681\"\u003eControl input range:\u003c\/strong\u003e Operates with a millivolt DC signal between 350 mV and 850 mV (open circuit) for compatibility with a wide range of controls.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1960\" data-start=\"1834\"\u003e\n\u003cp data-end=\"1960\" data-start=\"1836\"\u003e\u003cstrong data-end=\"1870\" data-start=\"1836\"\u003eBroad environmental tolerance:\u003c\/strong\u003e Supports ambient temperatures from 32°F to 150°F and humidity up to 95% non-condensing.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"2096\" data-start=\"1961\"\u003e\n\u003cp data-end=\"2096\" data-start=\"1963\"\u003e\u003cstrong data-end=\"1990\" data-start=\"1963\"\u003eOperational resilience:\u003c\/strong\u003e Functions reliably in storage conditions down to -40°F and up to 150°F without performance degradation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"2239\" data-start=\"2097\"\u003e\n\u003cp data-end=\"2239\" data-start=\"2099\"\u003e\u003cstrong data-end=\"2134\" data-start=\"2099\"\u003eLow inlet pressure requirement:\u003c\/strong\u003e Operates effectively at a maximum inlet pressure of 0.5 PSI (14.0 in. w.c.) for safe gas flow control.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"2370\" data-start=\"2240\"\u003e\n\u003cp data-end=\"2370\" data-start=\"2242\"\u003e\u003cstrong data-end=\"2267\" data-start=\"2242\"\u003eDurable construction:\u003c\/strong\u003e Built to Honeywell’s standards for mechanical strength and longevity in heating system environments.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-end=\"2513\" data-start=\"2372\"\u003eThe WV8870A1008 delivers the reliability and precision required for safe, consistent, and efficient gas flow control in heating appliances.\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":49105253761280,"sku":"WV8870A1008","price":274.89,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0388\/5331\/2557\/files\/s-l1600_3d9538ad-442d-462f-a76f-4102a9817be6.webp?v=1785543571","url":"https:\/\/alotechparts.com\/products\/wv8870a1008-honeywell-electronic-gas-control-valve","provider":"Alo Tech Solutions","version":"1.0","type":"link"}