{"product_id":"wilcom-f6121r-ribbon-fiber-identifier","title":"Wilcom F6121R Ribbon Fiber Identifier","description":"\u003cp\u003eThe Wilcom Model F6121R Optical Ribbon Fiber Identifier identifies optical fibers by detecting the optical signals being transmitted through a single-mode or multimode ribbon fiber (jacketed or not jacketed) and 3mm cable.\u003c\/p\u003e\n\u003cp\u003eIt operates by inserting ribbon fiber into the top of the unit which performs a macro-bend on the fiber. This bending technique allows the unit to detect the presence of light and the direction of light.\u003c\/p\u003e\n\u003cp\u003eWILCOM F6121R OPTICAL FIBER IDENTIFIER RIBBON, NEW The Wilcom Model F6121R Ribbon Fiber Identifier is a lightweight, rugged, easy-to-use installation and maintenance instrument designed for fast, accurate identification and traffic testing of optical signals without cutting the fiber cable or interrupting service.\u003c\/p\u003e\n\u003cp\u003eBy utilizing local detection technology (nondestructive macro-bend detection), this unit is ideal for use during routine maintenance and line modification, and can be used to locate a particular fiber line, non-obtrusively identify live fibers, and determine whether traffic is present. The Ribbon Fiber Identifier detects low frequency tones at 270 Hz, 1000 Hz and 2000 Hz. \u003c\/p\u003e\n\u003cp\u003eWhen traffic is present on the fiber under test, an audible tone can be heard as well as the traffic direction which is indicated by LEDs illuminating on the probe. During installations, maintenance, rerouting, or restorations it is often necessary to isolate a specific fiber without disrupting service. A light source such as Wilcom's Model FS1316 used in conjunction with the Ribbon Fiber Identifier can make the job a lot easier.\u003c\/p\u003e\n\u003cp\u003eThe Ribbon Fiber Identifier includes three easy to use field changeable adapter heads. Two adapter heads are dedicated to ribbon fiber making the unit ideal for verifying signal presence or absence (live or dark fiber) on ribbon fiber. One adapter head is for use on Bare Ribbon Fiber, and the other adapter head is for use on Jacketed Ribbon Fiber. The third interchangeable adapter head is for testing 3mm patch cords.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eDetects the Presence and Direction of Light\u003c\/li\u003e\n\u003cli\u003eOperates by Creating a Macro-Bend in the Fiber\u003c\/li\u003e\n\u003cli\u003eUse for Singlemode Applications\u003c\/li\u003e\n\u003cli\u003eIncludes 9V Alkaline Battery and Carry Case\u003c\/li\u003e\n\u003cli\u003eInterchangeable Heads: 3mm, Bare Ribbon, Jacketed Ribbon\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eDetector Sensitivity:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eBare Ribbon Fiber Adapter: -40dBm@1310nm, -50dBm@1550nm\u003c\/li\u003e\n\u003cli\u003eJacketed Ribbon Fiber Adapter: -30dBm@1310nm, -40dBm@1550nm\u003c\/li\u003e\n\u003cli\u003e3mm Adapter: -32.5dBm@1310nm, -40dBm@1550nm\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eRugged Metal Case\u003cbr\u003eField-proven lightweight rugged metal housing for years of heavy use.\u003c\/p\u003e\n\u003cp\u003eAudible Tone\u003cbr\u003eThe unit provides an audible tone in the presence of a fiber optic signal.\u003c\/p\u003e\n\u003cp\u003eLow Insertion Loss @ 1310 and 1550nm\u003cbr\u003eThe lowest insertion loss eliminates system interruptions.\u003c\/p\u003e\n\u003cp\u003eLED Indication\u003cbr\u003eLEDs indicate tone detection, Traffic presence, Traffic Direction, and Low Battery.\u003c\/p\u003e\n\u003cp\u003eHands-Free-Operation\u003cbr\u003eWith an easy to use thumb lock, hands-free operation can be enabled and disabled.\u003c\/p\u003e\n\u003cp\u003eThe Optical Fiber Identifier detects low-frequency tones at 270 Hz, 1000 Hz, and 2000 Hz. When traffic is present on the fiber under test, an audible tone can be heard as well as the traffic direction which is indicated by LEDs illuminating on the probe.\u003c\/p\u003e\n\u003cp\u003eThis unit can work with Wilcom's Model FS1316 and other light sources.\u003c\/p\u003e\n\u003cp\u003eThe Optical Fiber Identifier includes a carrying pouch containing three easy to use field interchangeable adapter heads to accommodate: one for bare ribbon fiber without a jacket, one for ribbon fiber with a jacket and one for 3mm jacketed fiber.\u003c\/p\u003e\n\u003cp\u003eA 2mm optional adapter is also available for testing 2mm cables. It is not included in the standard package and needs to be ordered separately.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHand-held ribbon fiber identifier F6121R\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eOperating Instructions\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv\u003e\u003cstrong\u003eIntroduction\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv\u003eThe Wilcom Model F6121R Ribbon Fiber Identifier is a rugged, hand-held, easy-to-use maintenance and installation instrument that identifies optical fibers by detecting the optical signals that are transmitted through a ribbon fiber.\u003c\/div\u003e\n\u003cdiv\u003eCheck for signal presence before re-routing or maintenance, perform continuity tests and check cable labeling.\u003c\/div\u003e\n\u003cdiv\u003eThis ribbon fiber identifier uses a safe macrobending technique that does not disrupt traffic. At the same time, it avoids damaging or overstressing the fiber Thus, the probability of inter- rupting service is eliminated.\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv\u003eSignals that the F6121R detect include continuous signal optical transmis-sion, and low frequency modulated tones at 270, 1000, and 2000 Hz. Whenthe F6121R detects traffic on a fiber being tested, one of two Traffic LEDson the F6121R illuminates to indicate the presence and direction of trans-mission.\u003c\/div\u003e\n\u003cdiv\u003eThe presence of tone is indicated by illumination of one of threeTone LEDs (Figure 1). The F6121R also has an easy to use thumb lockfeature for hands-free operation\u003c\/div\u003e\n\u003cdiv\u003e\u003cimg style=\"display: block; margin-left: auto; margin-right: auto;\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1026\/4509\/files\/Screenshot_2024-12-16_at_1.17.50_PM.png?v=1734383899\" alt=\"\"\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cp\u003e\u003cstrong\u003eOperating the F6121R\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv\u003eOperation of the F6121R is simple, as outlined in the following steps:\u003c\/div\u003e\n\u003cdiv\u003e1. Choose the correct adapter head for the type of ribbon fiber to betested. The F6121R is supplied with three adapters, each withindexing notch which is part of the ambient light reductiondesign as shown in Figure 2:\u003c\/div\u003e\n\u003cdiv\u003e(A) deep-slot, for 3 mm jacketed fiber (i.e., pigtails and jumpers)or loose tube fiber.\u003c\/div\u003e\n\u003cdiv\u003e(B) slotted, to accommodate jacketed ribbonfiber up to 12 count;\u003c\/div\u003e\n\u003cdiv\u003e(C) shallow-slot, to accommodate bareribbon fiber up to 12 count;\u003c\/div\u003e\n\u003cdiv\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1026\/4509\/files\/Screenshot_2024-12-16_at_4.00.49_PM.png?v=1734393681\" style=\"display: block; margin-left: auto; margin-right: auto;\"\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv\u003e2. Select the appropriate ribbon fiber adapter and slide it into themating slotted channel with slight downward pressure. Be sure toplace the adapter with the indexing notch facing the front of theF6121R as shown in Figure 3.\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1026\/4509\/files\/Screenshot_2024-12-16_at_4.01.51_PM.png?v=1734393721\" style=\"display: block; margin-left: auto; margin-right: auto;\"\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv\u003e3. Insert the fiber to be tested between the adapter and the top of theclamp (refer to Figure 4). Slide the thumb switch fully upwardand ensure that the fiber is installed properly in the alignmentgroove.\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv\u003e4. For hands-free operation, slide the thumb switch upward and \"rock\"forward to lock, and the fiber will be held in place( refer to Figure 4 ) \"rock\" backward to unlock.\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1026\/4509\/files\/Screenshot_2024-12-16_at_1.16.10_PM.png?v=1734383899\" style=\"display: block; margin-left: auto; margin-right: auto;\"\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv\u003ePresence of Traffic. Illumination of either Traffic LED indicatesthe detection and direction of traffic. This is useful in determiningwhether the fiber is transmitting or receiving at equipment terminallocations.The F6121R also provides an audible tone alert when traffic is detected.\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv\u003eTest Tone Detection. Illumination of any one of the2 kHz, 1 kHz, or 270 Hz LEDs indicates that a test tone is beingdetected, which ensures accurate identification of the fiber that isunder test.\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv\u003eThe 2 kHz tone can be generated by a source such as as WilcomModels FS1316 (includes also 1kHz and 270 Hz), FS1317 (includesalso 1kHz and 270 Hz), and FS8514A (includes also 1kHz and 270Hz). The F6121R can be used with all three units, as shown in Fig-ure 5. The recommended wavelength is 1550nm for tone indentification.\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv\u003eDuring operation at the lowest levels of tone detection(approximately -40dB core power), the tone LEDs may flicker,which indicates that the minimum range for detection was reached.\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cstrong\u003eMinimum Detector Sensitivity\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv\u003eBare Ribbon Fiber: -40.0 dBm @1310nm typical\u003c\/div\u003e\n\u003cdiv\u003eAdapter: -50.0 dBm @1550nm typical\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv\u003eJacketed Ribbon Fiber: -30.0 dBm @1310nm typical\u003c\/div\u003e\n\u003cdiv\u003eAdapter: -40.0 dBm @1550nm typical\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv\u003e3mm Adapter: -32.5 dBm @1310nm typical; -40.0 dBm @1550nm typical\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cstrong\u003eInsertion Loss\u003c\/strong\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\u003cspan\u003eRibbon Adapters: Ribbon Adapters; \u0026lt; 2.00 db @1550nm typical\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cspan\u003e3mm Adapter: \u0026lt; 0.11 db @1310nm typical; \u0026lt; 0.80 db @1550nm typical\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cspan\u003e\u003c\/span\u003e\u003cbr\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\u003cspan\u003eSelf Test. Each time the thumb switch is operated, the F6121R performs a self test. When this occurs all LEDs will illuminate and then after approximately one-half second turn off.\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cspan\u003e\u003c\/span\u003e\u003cbr\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\u003cspan\u003eLow Battery Indication. When the battery voltage becomes low, the \"LOW BAT\" LED illuminates. The unit will continue to operate for some time, but the battery should be replaced with a fresh 9-volt alkaline battery as soon as possible.\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cspan\u003e\u003c\/span\u003e\u003cbr\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\u003cspan\u003eBattery Replacement. To replace battery hold probe in hand, and with thumb on grip, Replace battery. To re-install cover reverse the steps. Gently place cover on probe and align cover keys with probe keyways. Slide cover forward.\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cspan\u003e\u003c\/span\u003e\u003cbr\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\u003cspan\u003eMaintenance. It is important that the optical ports remain clean and free of dust, dirt, grease, or other foreign matter.Cleaning with lint-free swabs and isopropyl alcohol is recommended for optimum performance.\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cp\u003e\u003cstrong\u003eDownload Product Spec Sheet:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"text-decoration: underline;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1026\/4509\/files\/F6121R.pdf?v=1598650208\" rel=\"noopener noreferrer\" target=\"_blank\"\u003eWilcom F6121R Optical Fiber Identifier Spec Sheet (PDF)\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Wilcom","offers":[{"title":"Default Title","offer_id":49084700950784,"sku":"F6121R","price":4828.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0388\/5331\/2557\/files\/F6121R_5c0d2bfe-a6e6-4443-8cae-6af3c3f3e14a.jpg?v=1785216859","url":"https:\/\/alotechparts.com\/products\/wilcom-f6121r-ribbon-fiber-identifier","provider":"Alo Tech Solutions","version":"1.0","type":"link"}