{"product_id":"vr8305p4337-honeywell-furnace-control-gas-valve","title":"VR8305P4337 | Honeywell Furnace Control Gas Valve","description":"\u003ch4\u003eDescription \u003c\/h4\u003e\n\u003cp\u003eThe VR8305P4337 is a dual direct ignition gas valve with a step-opening design for precise control in gas-fired appliances. It operates at 24 VDC and features 3\/4\" inlet and outlet connections, delivering stable performance for residential and light commercial systems.\u003c\/p\u003e\n\u003cp class=\"\" data-end=\"574\" data-start=\"284\"\u003e \u003c\/p\u003e\n\u003cp class=\"\" data-end=\"574\" data-start=\"284\"\u003e \u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications \u003c\/h4\u003e\n\u003ctable style=\"height: 713.625px; width: 100%;\" width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 32.75px;\"\u003e\n\u003cth class=\"text-left text-body1 text-bold py-10 pr-10 desktop:pr-[10rem] desktop:text-nowrap\" style=\"width: 31.0258%; text-align: left; height: 32.75px;\"\u003eCondition\u003c\/th\u003e\n\u003ctd class=\"text-left text-body1 py-10 desktop:w-[60%]\" style=\"width: 68.6099%; height: 32.75px;\"\u003eNew\/Never Used Surplus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 31.3056px;\"\u003e\n\u003cth class=\"text-left text-body1 text-bold py-10 pr-10 desktop:pr-[10rem] desktop:text-nowrap\" style=\"width: 31.0258%; text-align: left; height: 31.3056px;\"\u003eBrand\u003c\/th\u003e\n\u003ctd class=\"text-left text-body1 py-10 desktop:w-[60%]\" style=\"width: 68.6099%; height: 31.3056px;\"\u003e\u003cspan data-sheets-root=\"1\"\u003eHoneywell\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 28.4306px;\"\u003e\n\u003cth style=\"width: 31.0258%; text-align: left; height: 28.4306px;\"\u003eCategory\u003c\/th\u003e\n\u003ctd style=\"width: 68.6099%; height: 28.4306px;\"\u003e\n\u003cdiv class=\"mt-1 md:mt-0 column-left basis-2\/4 divide-y divide-rad-gray-10 border-b-[0.0625rem] border-rad-gray-10 md:border-0\"\u003e\n\u003cdiv class=\"flex gap-[1.75rem] md:gap-x-0 xl:gap-x-[1.875rem]\"\u003e\n\u003cdiv class=\"text-body-4 w-full font-light py-5 pl-4 md:py-6 md:pl-6 text-rad-gray-70\"\u003e\n\u003cdiv class=\"max-w-[8rem] break-words\"\u003e\n\u003cspan\u003e\u003c\/span\u003e\u003cspan\u003eValves\u003c\/span\u003e\u003cbr\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 42.25px;\"\u003e\n\u003cth style=\"width: 31.0258%; text-align: left; height: 42.25px;\"\u003ePart Number\u003c\/th\u003e\n\u003ctd style=\"width: 68.6099%; height: 42.25px;\"\u003e\u003cspan data-sheets-root=\"1\"\u003eVR8305P4337\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5972px;\"\u003e\n\u003cth style=\"width: 31.0258%; text-align: left; height: 19.5972px;\"\u003e\u003cspan\u003eSubcategory\u003c\/span\u003e\u003c\/th\u003e\n\u003ctd style=\"width: 68.6099%; height: 19.5972px;\"\u003e\u003cspan data-sheets-root=\"1\"\u003e\u003cspan\u003eGas Valve\u003c\/span\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 31.6806px;\"\u003e\n\u003cth style=\"width: 31.0258%; text-align: left; height: 31.6806px;\"\u003eSeries\u003c\/th\u003e\n\u003ctd style=\"width: 68.6099%; height: 31.6806px;\"\u003eVR8305\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1806px;\"\u003e\n\u003cth style=\"width: 31.0258%; text-align: left; height: 39.1806px;\"\u003eType\u003c\/th\u003e\n\u003ctd style=\"width: 68.6099%; height: 39.1806px;\"\u003eDual Direct Ignition Gas Valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1806px;\"\u003e\n\u003cth style=\"width: 31.0258%; text-align: left; height: 39.1806px;\"\u003eValve Opening\u003c\/th\u003e\n\u003ctd style=\"width: 68.6099%; height: 39.1806px;\"\u003eStep Opening\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1806px;\"\u003e\n\u003cth style=\"width: 31.0258%; text-align: left; height: 39.1806px;\" class=\"text-left text-body1 text-bold py-10 pr-10 desktop:pr-[10rem] desktop:text-nowrap\"\u003eInlet\/Outlet Size\u003c\/th\u003e\n\u003ctd style=\"width: 68.6099%; height: 39.1806px;\" class=\"text-left text-body1 py-10 desktop:w-[60%]\"\u003e3\/4\" NPT \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1944px;\"\u003e\n\u003cth style=\"width: 31.0258%; text-align: left; height: 39.1944px;\"\u003eOperating Voltage\u003c\/th\u003e\n\u003ctd style=\"width: 68.6099%; height: 39.1944px;\"\u003e24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1806px;\"\u003e\n\u003cth style=\"width: 31.0258%; text-align: left; height: 39.1806px;\"\u003ePressure Rating\u003c\/th\u003e\n\u003ctd style=\"width: 68.6099%; height: 39.1806px;\"\u003e3.5\" WC (Water Column)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1806px;\"\u003e\n\u003cth style=\"width: 31.0258%; text-align: left; height: 39.1806px;\"\u003eStep Valve Rating\u003c\/th\u003e\n\u003ctd style=\"width: 68.6099%; height: 39.1806px;\"\u003e0.9\" WC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1806px;\"\u003e\n\u003cth style=\"width: 31.0258%; text-align: left; height: 39.1806px;\"\u003eApplication\u003c\/th\u003e\n\u003ctd style=\"width: 68.6099%; height: 39.1806px;\"\u003eFurnaces, Heaters, Boilers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1806px;\"\u003e\n\u003cth style=\"width: 31.0258%; text-align: left; height: 39.1806px;\"\u003eControl Type\u003c\/th\u003e\n\u003ctd style=\"width: 68.6099%; height: 39.1806px;\"\u003eElectronic Ignition (Direct Spark)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 58.7917px;\"\u003e\n\u003cth style=\"width: 31.0258%; text-align: left; height: 58.7917px;\"\u003eDimensions\u003c\/th\u003e\n\u003ctd style=\"width: 68.6099%; height: 58.7917px;\"\u003e6 x 5 x 8 inches\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1944px;\"\u003e\n\u003cth style=\"width: 31.0258%; text-align: left; height: 39.1944px;\"\u003eMounting Orientation\u003c\/th\u003e\n\u003ctd style=\"width: 68.6099%; height: 39.1944px;\"\u003eMulti-position\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1806px;\"\u003e\n\u003cth style=\"width: 31.0258%; text-align: left; height: 39.1806px;\"\u003eProduct Status\u003c\/th\u003e\n\u003ctd style=\"width: 68.6099%; height: 39.1806px;\"\u003eDiscontinued by Manufacturer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 52.1806px;\"\u003e\n\u003cth style=\"width: 31.0258%; text-align: left; height: 52.1806px;\"\u003eIgnition Type\u003c\/th\u003e\n\u003ctd style=\"width: 68.6099%; height: 52.1806px;\"\u003ePilotless\/Direct Ignition Compatible\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 24.8056px;\"\u003e\n\u003cth style=\"width: 31.0258%; text-align: left; height: 24.8056px;\"\u003eWeight\u003c\/th\u003e\n\u003ctd style=\"width: 68.6099%; height: 24.8056px;\"\u003e\u003cspan\u003e1.40 lbs \u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003cspan style=\"font-size: 0.875rem;\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eInformation About \u003cspan data-sheets-root=\"1\"\u003eVR8305P4337\u003c\/span\u003e\n\u003c\/h4\u003e\n\u003cp\u003eThe VR8305P4337 is a step-opening gas valve from the VR8305 series, engineered for use in systems requiring direct ignition and staged gas flow control. Built with a dual-valve configuration, it allows for a controlled ignition sequence and steady gas pressure delivery. Its 3.5\" WC outlet pressure and 0.9\" step valve function make it suitable for use in furnaces, heaters, and boilers. Though discontinued by the manufacturer, this model remains compatible with many older 24 VDC applications still in service.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eStep Opening Mechanism: Provides a two-stage gas flow for smoother ignition and combustion.\u003c\/li\u003e\n\u003cli\u003eDual Direct Ignition: Supports both pilotless and direct spark ignition configurations.\u003c\/li\u003e\n\u003cli\u003eThreaded Ports: 3\/4\" x 3\/4\" NPT connections ensure easy integration into standard piping setups.\u003c\/li\u003e\n\u003cli\u003ePrecise Pressure Control: Regulates gas output at 3.5\" water column for consistent performance.\u003c\/li\u003e\n\u003cli\u003eVoltage Requirement: Operates reliably on 24 VDC, common in HVAC and heating systems.\u003c\/li\u003e\n\u003cli\u003eCompact Design: Measures approximately 6 x 5 x 8 inches, making it easy to mount in tight enclosures.\u003c\/li\u003e\n\u003cli\u003eDiscontinued Model: No longer produced, but still available through surplus or legacy parts suppliers.\u003c\/li\u003e\n\u003cli\u003eApplication Range: Designed for furnaces, unit heaters, and boilers with direct ignition controls.\u003c\/li\u003e\n\u003cli\u003eDurable Build: Built with industrial-grade materials to withstand heat and gas flow stress.\u003c\/li\u003e\n\u003cli\u003eLegacy Compatibility: Offers functional replacement for many older Honeywell gas valve assemblies.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe VR8305P4337 delivers the reliability and precision required for staged gas flow control in legacy heating applications.\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":49105317560576,"sku":"VR8305P4337","price":1095.15,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0388\/5331\/2557\/files\/41IWbPfUXDL.jpg?v=1785544856","url":"https:\/\/alotechparts.com\/products\/vr8305p4337-honeywell-furnace-control-gas-valve","provider":"Alo Tech Solutions","version":"1.0","type":"link"}