{"product_id":"vr8300c4050-honeywell-24v-natural-gas-valve-34-standing-pilot-step-opening","title":"VR8300C4050 | Honeywell 24V Natural Gas Valve 3\/4\" Standing Pilot Step Opening","description":"\u003ch4\u003eDescription \u003c\/h4\u003e\n\u003cp data-end=\"417\" data-start=\"137\"\u003eThe Honeywell VR8300C4050 Gas Valve is a 24V standing pilot gas control valve designed to regulate natural gas flow in residential and light commercial heating systems. Featuring 3\/4\" x 3\/4\" inlet and outlet connections, part number VR8300C4050 supports step-opening operation for smooth burner ignition. It is commonly used in compatible Honeywell and ICP gas-fired HVAC equipment.\u003c\/p\u003e\n\u003cp data-start=\"284\" data-end=\"574\" class=\"\"\u003e \u003c\/p\u003e\n\u003cp data-start=\"284\" data-end=\"574\" class=\"\"\u003e \u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications \u003c\/h4\u003e\n\u003ctable style=\"width: 100%; height: 372.282px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 48.3729%; height: 19.5938px;\"\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 48.3145%; height: 19.5938px;\"\u003eNew\/Never Used Surplus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 48.3729%; height: 19.5938px;\"\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 48.3145%; height: 19.5938px;\"\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 48.3729%; height: 19.5938px;\"\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 48.3145%; height: 19.5938px;\"\u003eHVAC Gas Controls\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 48.3729%; height: 19.5938px;\"\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 48.3145%; height: 19.5938px;\"\u003eVR8300C4050\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 48.3729%; height: 19.5938px;\"\u003e\u003cstrong\u003eSubcategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 48.3145%; height: 19.5938px;\"\u003eGas Valves\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 48.3729%; height: 19.5938px;\"\u003e\u003cstrong\u003eValve Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 48.3145%; height: 19.5938px;\"\u003eCombination Gas Valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 48.3729%; height: 19.5938px;\"\u003e\u003cstrong\u003eFuel Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 48.3145%; height: 19.5938px;\"\u003eNatural Gas\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 48.3729%; height: 19.5938px;\"\u003e\u003cstrong\u003eIgnition Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 48.3145%; height: 19.5938px;\"\u003eStanding Pilot\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 48.3729%; height: 19.5938px;\"\u003e\u003cstrong\u003eControl Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 48.3145%; height: 19.5938px;\"\u003e24 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 48.3729%; height: 19.5938px;\"\u003e\u003cstrong\u003eOpening Style\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 48.3145%; height: 19.5938px;\"\u003eStep Opening\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 48.3729%; height: 19.5938px;\"\u003e\u003cstrong\u003eInlet Size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 48.3145%; height: 19.5938px;\"\u003e3\/4 in NPT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 48.3729%; height: 19.5938px;\"\u003e\u003cstrong\u003eOutlet Size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 48.3145%; height: 19.5938px;\"\u003e3\/4 in NPT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 48.3729%; height: 19.5938px;\"\u003e\u003cstrong\u003ePressure Regulation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 48.3145%; height: 19.5938px;\"\u003eIntegral Regulator\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 48.3729%; height: 19.5938px;\"\u003e\u003cstrong\u003eMounting Orientation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 48.3145%; height: 19.5938px;\"\u003eMulti-Position\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 48.3729%; height: 19.5938px;\"\u003e\u003cstrong\u003eIncluded Accessories\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 48.3145%; height: 19.5938px;\"\u003eReducer Bushings\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 48.3729%; height: 19.5938px;\"\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 48.3145%; height: 19.5938px;\"\u003eGas Furnaces and Boilers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 48.3729%; height: 19.5938px;\"\u003e\u003cstrong\u003eOperating Environment\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 48.3145%; height: 19.5938px;\"\u003eIndoor HVAC Equipment\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 48.3729%; height: 19.5938px;\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 48.3145%; height: 19.5938px;\"\u003eApprox. 3.5 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eInformation About\u003cspan data-sheets-root=\"1\"\u003e VR8300C4050\u003c\/span\u003e\n\u003c\/h4\u003e\n\u003cp\u003eThe VR8300C4050 is part of Honeywell’s VR8300 series of combination gas valves engineered for reliable control in gas furnaces and boilers. This valve integrates pilot control, main gas regulation, and safety shutoff functions within a single compact assembly. It operates on a 24V control circuit and is designed specifically for natural gas applications with standing pilot systems. The valve includes reducer bushings to support flexible installation across various piping configurations.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eCombination Gas Valve Design: Integrates pilot, main valve, and regulator functions in one unit.\u003c\/li\u003e\n\u003cli\u003eStanding Pilot Operation: Designed for systems using continuous pilot ignition.\u003c\/li\u003e\n\u003cli\u003eStep-Opening Control: Allows gradual gas flow for smoother ignition and reduced burner stress.\u003c\/li\u003e\n\u003cli\u003e24V Control Voltage: Compatible with standard low-voltage HVAC control circuits.\u003c\/li\u003e\n\u003cli\u003eNatural Gas Application: Factory-configured for use with natural gas fuel systems.\u003c\/li\u003e\n\u003cli\u003e3\/4\" Inlet and Outlet Ports: Supports standard gas line connections in residential systems.\u003c\/li\u003e\n\u003cli\u003eIncluded Reducer Bushings: Enables flexible piping adaptation during installation.\u003c\/li\u003e\n\u003cli\u003eIntegrated Pressure Regulation: Maintains consistent outlet gas pressure for stable combustion.\u003c\/li\u003e\n\u003cli\u003eSafety Shutoff Function: Automatically stops gas flow during fault or pilot loss conditions.\u003c\/li\u003e\n\u003cli\u003eOEM Replacement Valve: Designed to meet Honeywell and ICP equipment specifications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe VR8300C4050 delivers the reliability and precision required for safe and consistent gas flow control in standing pilot HVAC systems.\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":49105051386112,"sku":"VR8300C4050","price":576.24,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0388\/5331\/2557\/files\/s-l1600_7ba8c593-0a11-4e73-bfe7-476d26974d6e.webp?v=1785538880","url":"https:\/\/alotechparts.com\/products\/vr8300c4050-honeywell-24v-natural-gas-valve-34-standing-pilot-step-opening","provider":"Alo Tech Solutions","version":"1.0","type":"link"}