{"product_id":"vlc-600-simplex-truealarm-lasercompact-air-aspiration-smoke-detector-vesda-technology","title":"VLC-600 | Simplex TrueAlarm LaserCOMPACT Air Aspiration Smoke Detector (VESDA Technology)","description":"\u003ch4\u003eDescription \u003c\/h4\u003e\n\u003cp data-end=\"396\" data-start=\"144\"\u003eThe Simplex VLC-600 TrueAlarm LaserCOMPACT Smoke Sensor is an air aspiration smoke detector designed for high-sensitivity detection using laser-based technology. It provides precise, addressable communication via MAPNET II or IDNet circuits for integration with Simplex 4100\/4100U fire alarm control panels.\u003c\/p\u003e\n\u003cp class=\"\" data-end=\"574\" data-start=\"284\"\u003e \u003c\/p\u003e\n\u003cp class=\"\" data-end=\"574\" data-start=\"284\"\u003e \u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications \u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNew\/Never Used Surplus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSimplex\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFire Safety\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eVLC-600\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSubcategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSmoke Detector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSensor Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAir aspiration laser-based smoke detector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSupply Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e18–30 VDC (from fire alarm control panel)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSupervisory Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e175 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAlarm Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e190 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCommunication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMAPNET II or 4100U IDNet (auto-selected)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAddressing\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOne address per sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eElectrical Termination\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTerminal blocks for 18–12 AWG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e–10°C to +39°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSampled Air Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e–20°C to +60°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHumidity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10–95% RH, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSampling Area\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUp to 800 m² coverage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAlarm Sensitivity Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.05% to 12%\/m obscuration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSensitivity Levels\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eThree selectable alarm thresholds\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eService Port\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRS-232 (DB-9) for VESDA Vconfig Pro software\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEnclosure Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNEMA 1 (IP30)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCertification\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUL 268, SSL AS 1603.8–1996\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e225 × 225 × 85 mm (approx.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.9 kg (4.2 lbs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eInformation About \u003cspan data-sheets-root=\"1\"\u003eVLC-600\u003c\/span\u003e\n\u003c\/h4\u003e\n\u003cp\u003eThe VLC-600 TrueAlarm LaserCOMPACT is a compact air aspiration smoke detector that draws air samples through a pipe network for continuous monitoring of smoke presence. Using VESDA® technology, it delivers early warning detection and high reliability in mission-critical environments. It communicates obscuration data to the host fire alarm control panel, which interprets the information using the TrueAlarm analog sensing process. The VLC-600 supports programmable sensitivity thresholds and diagnostic communication for trouble conditions such as airflow faults or dirty filters. Designed for precision and durability, it complies with UL 268 standards and is suitable for clean rooms, data centers, and similar environments.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eLaser-Based Detection: Utilizes high-intensity laser light for precise smoke particle measurement.\u003c\/li\u003e\n\u003cli\u003eAir Aspiration Technology: Continuously samples air via a connected pipe network for early fire detection.\u003c\/li\u003e\n\u003cli\u003eCompact Design: 225 mm square enclosure ideal for tight installation spaces.\u003c\/li\u003e\n\u003cli\u003eDual-Stage Dust Filtration: Maintains detection accuracy and extends maintenance intervals.\u003c\/li\u003e\n\u003cli\u003eProgrammable Sensitivity: Adjustable alarm thresholds from 0.05%\/m to 12%\/m obscuration.\u003c\/li\u003e\n\u003cli\u003eMAPNET II \/ IDNet Communication: Automatically selects addressable communication format with Simplex panels.\u003c\/li\u003e\n\u003cli\u003eStatus Indication: Local LED provides real-time visual feedback of sensor state; supports optional remote LED.\u003c\/li\u003e\n\u003cli\u003eDiagnostic Reporting: Communicates airflow, mechanical, and electrical fault conditions to the FACP.\u003c\/li\u003e\n\u003cli\u003ePanel Compatibility: Works directly with Simplex 4100ES, 4100U, and compatible TrueAlarm addressable systems.\u003c\/li\u003e\n\u003cli\u003eHigh Environmental Tolerance: Operates from –20°C to +60°C with 10–95% non-condensing humidity.\u003c\/li\u003e\n\u003cli\u003eWide Area Coverage: Supports up to 800 m² of coverage and long sampling pipe runs using VESDA Aspire™ design tools.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe VLC-600 delivers precise, intelligent air sampling smoke detection and integrates seamlessly into advanced Simplex fire alarm systems.\u003c\/p\u003e","brand":"Simplex","offers":[{"title":"Default Title","offer_id":49105157685504,"sku":"VLC-600","price":6720.84,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0388\/5331\/2557\/files\/s-l1600_1cbb4790-a98d-4bab-af29-b76511c17dec.webp?v=1785541547","url":"https:\/\/alotechparts.com\/products\/vlc-600-simplex-truealarm-lasercompact-air-aspiration-smoke-detector-vesda-technology","provider":"Alo Tech Solutions","version":"1.0","type":"link"}