{"product_id":"uda2182-cc1-nn2-nn-n-0e00-ee-honeywell-single-input-analyzer-for-contacting-conductivity","title":"UDA2182-CC1-NN2-NN-N-0E00-EE | Honeywell Single Input Analyzer for Contacting Conductivity","description":"\u003ch4\u003eDescription \u003c\/h4\u003e\n\u003cp\u003eThe Honeywell UDA2182-CC1-NN2-NN-N-0E00-EE is a single-channel analytical analyzer designed for precise conductivity measurement in industrial liquid analysis applications. It combines digital reliability with dual current outputs and integrated alarm functions in a compact panel-mounted design.\u003c\/p\u003e\n\u003cp class=\"\" data-end=\"574\" data-start=\"284\"\u003e \u003c\/p\u003e\n\u003cp class=\"\" data-end=\"574\" data-start=\"284\"\u003e \u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications \u003c\/h4\u003e\n\u003ctable style=\"height: 368.703px; width: 100%;\" width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 28px;\"\u003e\n\u003cth class=\"text-left text-body1 text-bold py-10 pr-10 desktop:pr-[10rem] desktop:text-nowrap\" style=\"width: 31.0909%; text-align: left; height: 28px;\"\u003eCondition\u003c\/th\u003e\n\u003ctd class=\"text-left text-body1 py-10 desktop:w-[60%]\" style=\"width: 68.5455%; height: 28px;\"\u003eNew\/Never Used Surplus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 20.4844px;\"\u003e\n\u003cth class=\"text-left text-body1 text-bold py-10 pr-10 desktop:pr-[10rem] desktop:text-nowrap\" style=\"width: 31.0909%; text-align: left; height: 20.4844px;\"\u003eBrand\u003c\/th\u003e\n\u003ctd class=\"text-left text-body1 py-10 desktop:w-[60%]\" style=\"width: 68.5455%; height: 20.4844px;\"\u003e\u003cspan data-sheets-root=\"1\"\u003eHoneywell\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 20.4844px;\"\u003e\n\u003cth style=\"width: 31.0909%; text-align: left; height: 20.4844px;\"\u003eCategory\u003c\/th\u003e\n\u003ctd style=\"width: 68.5455%; height: 20.4844px;\"\u003e\n\u003cdiv class=\"mt-1 md:mt-0 column-left basis-2\/4 divide-y divide-rad-gray-10 border-b-[0.0625rem] border-rad-gray-10 md:border-0\"\u003e\n\u003cdiv class=\"flex gap-[1.75rem] md:gap-x-0 xl:gap-x-[1.875rem]\"\u003e\n\u003cdiv class=\"text-body-4 w-full font-light py-5 pl-4 md:py-6 md:pl-6 text-rad-gray-70\"\u003e\n\u003cdiv class=\"max-w-[8rem] break-words\"\u003e\n\u003cspan\u003e\u003c\/span\u003e\u003cspan\u003eControls \u0026amp; Indicators\u003c\/span\u003e\u003cbr\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 33.5px;\"\u003e\n\u003cth style=\"width: 31.0909%; text-align: left; height: 33.5px;\"\u003ePart Number\u003c\/th\u003e\n\u003ctd style=\"width: 68.5455%; height: 33.5px;\"\u003e\u003cspan data-sheets-root=\"1\"\u003eUDA2182-CC1-NN2-NN-N-0E00-EE\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 23.2969px;\"\u003e\n\u003cth style=\"width: 31.0909%; text-align: left; height: 23.2969px;\"\u003e\u003cspan\u003eSubcategory\u003c\/span\u003e\u003c\/th\u003e\n\u003ctd style=\"width: 68.5455%; height: 23.2969px;\"\u003e\u003cspan data-sheets-root=\"1\"\u003e\u003cspan\u003eTemperature\/Process Control\u003c\/span\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 27.7969px;\"\u003e\n\u003cth style=\"width: 31.0909%; text-align: left; height: 27.7969px;\"\u003e\u003cspan\u003eSeries\u003c\/span\u003e\u003c\/th\u003e\n\u003ctd style=\"width: 68.5455%; height: 27.7969px;\"\u003e\u003cspan data-sheets-root=\"1\"\u003e\u003cspan\u003eUDA2182\u003c\/span\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22.9375px;\"\u003e\n\u003cth style=\"width: 31.0909%; text-align: left; height: 22.9375px;\"\u003e\u003cspan\u003eAnalyzer Type\u003c\/span\u003e\u003c\/th\u003e\n\u003ctd style=\"width: 68.5455%; height: 22.9375px;\"\u003e\u003cspan data-sheets-root=\"1\"\u003e\u003cspan\u003eSingle Input (Contacting Conductivity)\u003c\/span\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 34px;\"\u003e\n\u003cth style=\"width: 31.0909%; text-align: left; height: 34px;\"\u003eChannel 1 Input\u003c\/th\u003e\n\u003ctd style=\"width: 68.5455%; height: 34px;\"\u003eContacting Conductivity\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 30.125px;\"\u003e\n\u003cth style=\"width: 31.0909%; text-align: left; height: 30.125px;\" class=\"text-left text-body1 text-bold py-10 pr-10 desktop:pr-[10rem] desktop:text-nowrap\"\u003eChannel 2 Input\u003cbr\u003e\n\u003c\/th\u003e\n\u003ctd style=\"width: 68.5455%; height: 30.125px;\" class=\"text-left text-body1 py-10 desktop:w-[60%]\"\u003eNone\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22.9688px;\"\u003e\n\u003cth style=\"width: 31.0909%; text-align: left; height: 22.9688px;\"\u003eOutputs\u003c\/th\u003e\n\u003ctd style=\"width: 68.5455%; height: 22.9688px;\"\u003e(2) 4–20 mA analog outputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 24.8125px;\"\u003e\n\u003cth style=\"width: 31.0909%; text-align: left; height: 24.8125px;\"\u003eAlarm Relays\u003c\/th\u003e\n\u003ctd style=\"width: 68.5455%; height: 24.8125px;\"\u003e(2) SPDT programmable alarm relays\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 20.4844px;\"\u003e\n\u003cth style=\"width: 31.0909%; text-align: left; height: 20.4844px;\"\u003eCommunications\u003c\/th\u003e\n\u003ctd style=\"width: 68.5455%; height: 20.4844px;\"\u003e\u003cspan\u003eInfrared (IR) diagnostics port\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003cth style=\"width: 31.0909%; text-align: left; height: 19.5938px;\"\u003eMounting Type\u003c\/th\u003e\n\u003ctd style=\"width: 68.5455%; height: 19.5938px;\"\u003e\u003cspan\u003ePanel Mount\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003cth style=\"width: 31.0909%; text-align: left; height: 19.5938px;\"\u003eDisplay\u003c\/th\u003e\n\u003ctd style=\"width: 68.5455%; height: 19.5938px;\"\u003e\u003cspan\u003eLCD with menu navigation\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 20.625px;\"\u003e\n\u003cth style=\"width: 31.0909%; text-align: left; height: 20.625px;\"\u003eWeight\u003c\/th\u003e\n\u003ctd style=\"width: 68.5455%; height: 20.625px;\"\u003e\u003cspan\u003e2.59 lbs\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003cspan style=\"font-size: 0.875rem;\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eInformation About \u003cspan data-sheets-root=\"1\"\u003eUDA2182-CC1-NN2-NN-N-0E00-EE\u003c\/span\u003e\n\u003c\/h4\u003e\n\u003cp\u003eThe UDA2182 model is a universal dual-input analytical platform, and the CC1-NN2 configuration defines it as a single-input unit for contacting conductivity on Channel 1, with Channel 2 unused. It includes two 4–20 mA analog outputs for process control and two programmable alarm relays for safety and alert functions. This panel-mount unit supports non-invasive infrared communication for diagnostics and configuration, making it suitable for chemical, water treatment, and industrial utility monitoring. Built for durability and ease of use, the UDA2182 features a large LCD display, menu-driven interface, and flexible mounting options.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSingle Input: Contacting Conductivity (CH1): Measures conductivity through precision sensors connected to input channel 1.\u003c\/li\u003e\n\u003cli\u003eDual 4–20 mA Analog Outputs: Provides scalable current loops for real-time control and monitoring.\u003c\/li\u003e\n\u003cli\u003eTwo Configurable Alarm Relays: Enables alerts or interlocks based on user-defined measurement thresholds.\u003c\/li\u003e\n\u003cli\u003eInfrared Communications Port: Allows setup and diagnostics without direct electrical contact.\u003c\/li\u003e\n\u003cli\u003ePanel Mount Design: Supports easy integration into control panels or instrument enclosures.\u003c\/li\u003e\n\u003cli\u003eDual-Channel Platform (CH2 Unused): Offers future expandability while maintaining single-input operation.\u003c\/li\u003e\n\u003cli\u003eMenu-Driven Interface: Simplifies navigation and calibration via keypad and display.\u003c\/li\u003e\n\u003cli\u003eReliable for Harsh Environments: Suitable for industrial process applications like water treatment or chemical manufacturing.\u003c\/li\u003e\n\u003cli\u003eReal-Time Measurement: High-speed data refresh for immediate process feedback.\u003c\/li\u003e\n\u003cli\u003eCompact Footprint: Saves space while delivering full analytical control and output.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe UDA2182-CC1-NN2-NN-N-0E00-EE delivers robust, accurate conductivity analysis with integrated outputs and alarms, all within a scalable and easy-to-install form factor.\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":49105357963520,"sku":"UDA2182-CC1-NN2-NN-N-0E00-EE","price":5358.15,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0388\/5331\/2557\/files\/500-honeywell-uda2182-analytical-controller-3d.jpg?v=1785545569","url":"https:\/\/alotechparts.com\/products\/uda2182-cc1-nn2-nn-n-0e00-ee-honeywell-single-input-analyzer-for-contacting-conductivity","provider":"Alo Tech Solutions","version":"1.0","type":"link"}