{"product_id":"uda2182-cc1-nn2-nn-n-0e00-ee-000-honeywell-single-input-conductivity-analyzer-dual-outputs","title":"UDA2182-CC1-NN2-NN-N-0E00-EE-000 | Honeywell Single-Input Conductivity Analyzer, Dual Outputs","description":"\u003ch4\u003eDescription\u003c\/h4\u003e\n\u003cp\u003eThe Honeywell UDA2182-CC1-NN2-NN-N-0E00-EE-000 is a single-input analytical analyzer engineered for accurate contacting conductivity measurement in industrial process environments. It provides dual 4–20 mA outputs, alarm relays, and an integrated IR communication port for dependable monitoring and control of critical solution parameters.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications\u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNew\/Never Used Surplus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eProcess Instrumentation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUDA2182-CC1-NN2-NN-N-0E00-EE-000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSubcategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAnalytical Analyzers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUDA2182 Universal Dual Analyzer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Channels\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSingle input – Contacting Conductivity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSecond Input\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNone\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTwo isolated 4–20 mA analog outputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAlarm Relays\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTwo user-configurable relays\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCommunication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eInfrared (IR) local communication port\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDisplay\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBacklit operator interface with menu navigation (standard UDA2182)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePanel mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Requirements\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100–240 VAC, 50\/60 Hz (standard for UDA2182 models)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperature Compensation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSupported (via compatible sensors)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEnclosure Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFront panel NEMA 4X \/ IP66 (typical for this series)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLanguages\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEnglish manual included\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMeasurement Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eContacting conductivity with configurable ranges\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWater treatment, chemical processes, rinse systems, industrial monitoring\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStandard UDA2182 panel cutout and housing size\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eApprox. 4–6 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eInformation About UDA2182-CC1-NN2-NN-N-0E00-EE-000\u003c\/h4\u003e\n\u003cp\u003eThe UDA2182-CC1-NN2-NN-N-0E00-EE-000 is part of Honeywell’s UDA2182 Universal Dual Analyzer platform, known for its modular design and flexible configuration options. This model is equipped with one conductivity channel and no second input, making it ideal for systems requiring focused, high-precision conductivity monitoring. Its panel-mount architecture, clear operator interface, and onboard diagnostics support seamless integration into existing control panels and distributed control systems. Designed for demanding process, water treatment, and manufacturing environments, it delivers stable measurement performance supported by Honeywell’s robust analytical firmware and hardware architecture.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSingle Conductivity Input: Provides high-accuracy contacting conductivity measurement for critical process streams.\u003c\/li\u003e\n\u003cli\u003eDual 4–20 mA Outputs: Supports analog retransmission for PLC, DCS, or chart recorder integration.\u003c\/li\u003e\n\u003cli\u003eTwo Alarm Relays: Enables process alarms, pump activation, limit monitoring, or safety interlocks.\u003c\/li\u003e\n\u003cli\u003eInfrared Communication Port: Offers convenient configuration and diagnostics without opening the enclosure.\u003c\/li\u003e\n\u003cli\u003ePanel Mount Design: Simplifies installation into instrument panels or analyzer racks.\u003c\/li\u003e\n\u003cli\u003eAdvanced Measurement Processing: Includes temperature compensation, signal filtering, and calibration tools.\u003c\/li\u003e\n\u003cli\u003eWide Industrial Compatibility: Works with Honeywell contacting conductivity sensors and standard process controls.\u003c\/li\u003e\n\u003cli\u003eDurable Construction: Built for continuous-duty applications in water, chemical, and industrial process facilities.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe UDA2182-CC1-NN2-NN-N-0E00-EE-000 delivers the reliability and precision required for stable conductivity analysis in automated process environments.\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":49105075142912,"sku":"UDA2182-CC1-NN2-NN-N-0E00-EE-000","price":3967.53,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0388\/5331\/2557\/files\/uda2182.png?v=1785539502","url":"https:\/\/alotechparts.com\/products\/uda2182-cc1-nn2-nn-n-0e00-ee-000-honeywell-single-input-conductivity-analyzer-dual-outputs","provider":"Alo Tech Solutions","version":"1.0","type":"link"}