{"product_id":"tqdl21175-general-electric-175a-2-pole-120240v-thermal-magnetic-molded-case-circuit-breaker","title":"TQDL21175 | General Electric 175A 2-Pole 120\/240V Thermal Magnetic Molded Case Circuit Breaker","description":"\u003ch4\u003eDescription \u003c\/h4\u003e\n\u003cp data-end=\"447\" data-start=\"168\"\u003eThe General Electric TQDL21175 is a molded case circuit breaker designed to provide dependable overcurrent and short-circuit protection in residential, commercial, and light industrial applications. Rated at 175 Amps and 120\/240 VAC, this 2-pole breaker ensures consistent circuit safety and performance. Its plug-in design and thermal magnetic trip mechanism make it both efficient and easy to install in compatible panel systems.\u003c\/p\u003e\n\u003cp class=\"\" data-end=\"574\" data-start=\"284\"\u003e \u003c\/p\u003e\n\u003cp class=\"\" data-end=\"574\" data-start=\"284\"\u003e \u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications \u003c\/h4\u003e\n\u003ctable style=\"width: 99.9988%; height: 431.215px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.6007px;\"\u003e\n\u003ctd style=\"width: 41.7059%; height: 19.6007px;\"\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 56.1554%; height: 19.6007px;\"\u003eNew\/Never Used Surplus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6007px;\"\u003e\n\u003ctd style=\"width: 41.7059%; height: 19.6007px;\"\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 56.1554%; height: 19.6007px;\"\u003eGeneral Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6007px;\"\u003e\n\u003ctd style=\"width: 41.7059%; height: 19.6007px;\"\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 56.1554%; height: 19.6007px;\"\u003eCircuit Breakers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6007px;\"\u003e\n\u003ctd style=\"width: 41.7059%; height: 19.6007px;\"\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 56.1554%; height: 19.6007px;\"\u003eTQDL21175\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6007px;\"\u003e\n\u003ctd style=\"width: 41.7059%; height: 19.6007px;\"\u003e\u003cstrong\u003eSubcategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 56.1554%; height: 19.6007px;\"\u003eMolded Case Circuit Breakers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6007px;\"\u003e\n\u003ctd style=\"width: 41.7059%; height: 19.6007px;\"\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 56.1554%; height: 19.6007px;\"\u003eQ-Line TQDL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6007px;\"\u003e\n\u003ctd style=\"width: 41.7059%; height: 19.6007px;\"\u003e\u003cstrong\u003eType\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 56.1554%; height: 19.6007px;\"\u003eThermal Magnetic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6007px;\"\u003e\n\u003ctd style=\"width: 41.7059%; height: 19.6007px;\"\u003e\u003cstrong\u003ePoles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 56.1554%; height: 19.6007px;\"\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6007px;\"\u003e\n\u003ctd style=\"width: 41.7059%; height: 19.6007px;\"\u003e\u003cstrong\u003ePhase\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 56.1554%; height: 19.6007px;\"\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6007px;\"\u003e\n\u003ctd style=\"width: 41.7059%; height: 19.6007px;\"\u003e\u003cstrong\u003eCurrent Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 56.1554%; height: 19.6007px;\"\u003e175 Amp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6007px;\"\u003e\n\u003ctd style=\"width: 41.7059%; height: 19.6007px;\"\u003e\u003cstrong\u003eVoltage Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 56.1554%; height: 19.6007px;\"\u003e120\/240 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6007px;\"\u003e\n\u003ctd style=\"width: 41.7059%; height: 19.6007px;\"\u003e\u003cstrong\u003eInterrupting Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 56.1554%; height: 19.6007px;\"\u003e10 kAIC @ 120V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6007px;\"\u003e\n\u003ctd style=\"width: 41.7059%; height: 19.6007px;\"\u003e\u003cstrong\u003eTrip Functions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 56.1554%; height: 19.6007px;\"\u003eLong-Time and Instantaneous\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6007px;\"\u003e\n\u003ctd style=\"width: 41.7059%; height: 19.6007px;\"\u003e\u003cstrong\u003eConnection Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 56.1554%; height: 19.6007px;\"\u003ePlug-In\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6007px;\"\u003e\n\u003ctd style=\"width: 41.7059%; height: 19.6007px;\"\u003e\u003cstrong\u003eProtection Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 56.1554%; height: 19.6007px;\"\u003eOverload and Short Circuit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6007px;\"\u003e\n\u003ctd style=\"width: 41.7059%; height: 19.6007px;\"\u003e\u003cstrong\u003eApprovals\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 56.1554%; height: 19.6007px;\"\u003eUL, CSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6007px;\"\u003e\n\u003ctd style=\"width: 41.7059%; height: 19.6007px;\"\u003e\u003cstrong\u003eTerminal Connection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 56.1554%; height: 19.6007px;\"\u003eLoad Side Lug\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6007px;\"\u003e\n\u003ctd style=\"width: 41.7059%; height: 19.6007px;\"\u003e\u003cstrong\u003eFrame Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 56.1554%; height: 19.6007px;\"\u003eTQDL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6007px;\"\u003e\n\u003ctd style=\"width: 41.7059%; height: 19.6007px;\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 56.1554%; height: 19.6007px;\"\u003e0.70 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eInformation About TQDL21175\u003c\/h4\u003e\n\u003cp\u003eThe TQDL21175 is part of General Electric’s Q-Line TQDL Series, a line of molded case circuit breakers engineered for precision and durability. It features a thermal magnetic protection system that combines overload and instantaneous trip functions for complete circuit safety. The unit’s plug-in configuration allows fast installation into GE Q-Line load centers without additional wiring. Built to meet UL and CSA standards, the TQDL21175 is ideal for use in single-phase systems requiring reliable performance and straightforward maintenance.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThermal Magnetic Trip Unit: Provides reliable overload and short-circuit protection.\u003c\/li\u003e\n\u003cli\u003e2-Pole Design: Offers simultaneous protection for both conductors in single-phase systems.\u003c\/li\u003e\n\u003cli\u003eHigh Interrupting Capacity: Rated 10 kAIC at 120V for enhanced fault protection.\u003c\/li\u003e\n\u003cli\u003ePlug-In Connection: Enables quick installation and secure panelboard integration.\u003c\/li\u003e\n\u003cli\u003eCommon Trip Mechanism: Ensures both poles disconnect together during a fault event.\u003c\/li\u003e\n\u003cli\u003eCompact Form Factor: Fits easily into GE Q-Line load centers for efficient use of space.\u003c\/li\u003e\n\u003cli\u003eCompliance and Safety: UL and CSA approved for verified quality and operational reliability.\u003c\/li\u003e\n\u003cli\u003eDurable Construction: Molded case ensures long-lasting mechanical and electrical integrity.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe TQDL21175 delivers the reliability and precision required for effective circuit protection in demanding electrical distribution systems.\u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":49105082515712,"sku":"TQDL21175","price":3251.64,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0388\/5331\/2557\/files\/2025-11-09_18.07.06.png?v=1785539715","url":"https:\/\/alotechparts.com\/products\/tqdl21175-general-electric-175a-2-pole-120240v-thermal-magnetic-molded-case-circuit-breaker","provider":"Alo Tech Solutions","version":"1.0","type":"link"}