{"product_id":"tqd22100wl-general-electric-100a-2-pole-120240v-thermal-magnetic-molded-case-circuit-breaker","title":"TQD22100WL | General Electric 100A 2-Pole 120\/240V Thermal Magnetic Molded Case Circuit Breaker","description":"\u003ch4\u003eDescription \u003c\/h4\u003e\n\u003cp data-end=\"447\" data-start=\"168\"\u003eThe General Electric TQD22100WL is a 2-pole molded case circuit breaker designed for dependable overcurrent and short-circuit protection in residential, commercial, and light industrial installations. With a current rating of 100 amps and a voltage rating of 120\/240 VAC, this breaker ensures safe circuit performance in both main and branch applications. Its feed-thru connection and thermal magnetic trip mechanism provide reliable, long-term operation in demanding electrical systems.\u003c\/p\u003e\n\u003cp class=\"\" data-end=\"574\" data-start=\"284\"\u003e \u003c\/p\u003e\n\u003cp class=\"\" data-end=\"574\" data-start=\"284\"\u003e \u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications \u003c\/h4\u003e\n\u003ctable style=\"width: 99.9988%; height: 470.417px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.6007px;\"\u003e\n\u003ctd style=\"width: 41.296%; height: 19.6007px;\"\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 56.5653%; height: 19.6007px;\"\u003eNew\/Never Used Surplus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6007px;\"\u003e\n\u003ctd style=\"width: 41.296%; height: 19.6007px;\"\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 56.5653%; height: 19.6007px;\"\u003eGeneral Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6007px;\"\u003e\n\u003ctd style=\"width: 41.296%; height: 19.6007px;\"\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 56.5653%; height: 19.6007px;\"\u003eCircuit Breakers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6007px;\"\u003e\n\u003ctd style=\"width: 41.296%; height: 19.6007px;\"\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 56.5653%; height: 19.6007px;\"\u003eTQD22100WL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6007px;\"\u003e\n\u003ctd style=\"width: 41.296%; height: 19.6007px;\"\u003e\u003cstrong\u003eSubcategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 56.5653%; height: 19.6007px;\"\u003eMolded Case Circuit Breakers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6007px;\"\u003e\n\u003ctd style=\"width: 41.296%; height: 19.6007px;\"\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 56.5653%; height: 19.6007px;\"\u003eQ-Line TQD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6007px;\"\u003e\n\u003ctd style=\"width: 41.296%; height: 19.6007px;\"\u003e\u003cstrong\u003eType\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 56.5653%; height: 19.6007px;\"\u003eThermal Magnetic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6007px;\"\u003e\n\u003ctd style=\"width: 41.296%; height: 19.6007px;\"\u003e\u003cstrong\u003ePoles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 56.5653%; height: 19.6007px;\"\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6007px;\"\u003e\n\u003ctd style=\"width: 41.296%; height: 19.6007px;\"\u003e\u003cstrong\u003ePhase\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 56.5653%; height: 19.6007px;\"\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6007px;\"\u003e\n\u003ctd style=\"width: 41.296%; height: 19.6007px;\"\u003e\u003cstrong\u003eCurrent Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 56.5653%; height: 19.6007px;\"\u003e100 Amp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6007px;\"\u003e\n\u003ctd style=\"width: 41.296%; height: 19.6007px;\"\u003e\u003cstrong\u003eVoltage Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 56.5653%; height: 19.6007px;\"\u003e120\/240 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6007px;\"\u003e\n\u003ctd style=\"width: 41.296%; height: 19.6007px;\"\u003e\u003cstrong\u003eInterrupting Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 56.5653%; height: 19.6007px;\"\u003e10 kAIC @ 240V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6007px;\"\u003e\n\u003ctd style=\"width: 41.296%; height: 19.6007px;\"\u003e\u003cstrong\u003eTrip Functions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 56.5653%; height: 19.6007px;\"\u003eLong-Time and Instantaneous\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6007px;\"\u003e\n\u003ctd style=\"width: 41.296%; height: 19.6007px;\"\u003e\u003cstrong\u003eConnection Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 56.5653%; height: 19.6007px;\"\u003eFeed-Thru\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6007px;\"\u003e\n\u003ctd style=\"width: 41.296%; height: 19.6007px;\"\u003e\u003cstrong\u003eTerminal Connection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 56.5653%; height: 19.6007px;\"\u003eLine \u0026amp; Load Side Lug\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6007px;\"\u003e\n\u003ctd style=\"width: 41.296%; height: 19.6007px;\"\u003e\u003cstrong\u003eProtection Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 56.5653%; height: 19.6007px;\"\u003eOverload and Short Circuit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6007px;\"\u003e\n\u003ctd style=\"width: 41.296%; height: 19.6007px;\"\u003e\u003cstrong\u003eMounting Style\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 56.5653%; height: 19.6007px;\"\u003eBolt-On \/ Feed-Thru\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6007px;\"\u003e\n\u003ctd style=\"width: 41.296%; height: 19.6007px;\"\u003e\u003cstrong\u003eApprovals\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 56.5653%; height: 19.6007px;\"\u003eUL, CSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6007px;\"\u003e\n\u003ctd style=\"width: 41.296%; height: 19.6007px;\"\u003e\u003cstrong\u003eTemperature Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 56.5653%; height: 19.6007px;\"\u003e40 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6007px;\"\u003e\n\u003ctd style=\"width: 41.296%; height: 19.6007px;\"\u003e\u003cstrong\u003eDimensions (H x W x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 56.5653%; height: 19.6007px;\"\u003e6.56\" x 2.75\" x 2.67\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6007px;\"\u003e\n\u003ctd style=\"width: 41.296%; height: 19.6007px;\"\u003e\u003cstrong\u003eFor Use With\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 56.5653%; height: 19.6007px;\"\u003eLighting Panels, Modular Metering\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6007px;\"\u003e\n\u003ctd style=\"width: 41.296%; height: 19.6007px;\"\u003e\u003cstrong\u003eWire Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 56.5653%; height: 19.6007px;\"\u003e4 AWG to 300 MCM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6007px;\"\u003e\n\u003ctd style=\"width: 41.296%; height: 19.6007px;\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 56.5653%; height: 19.6007px;\"\u003e2.85 lbs (1.29 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eInformation About TQD22100WL\u003c\/h4\u003e\n\u003cp\u003eThe TQD22100WL is part of General Electric’s Q-Line TQD Series, engineered for high performance and durability across multiple electrical applications. It features a thermal magnetic protection system that combines long-time and instantaneous trip functions for efficient fault interruption. Designed with a feed-thru connection, it supports quick integration into GE panelboards, including AQ Series panels. Built to meet UL and CSA standards, the TQD22100WL is ideal for use in lighting panels, modular metering systems, and branch circuit protection.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThermal Magnetic Trip System: Protects against both overload and short-circuit conditions.\u003c\/li\u003e\n\u003cli\u003e2-Pole Configuration: Provides full circuit protection for single-phase applications.\u003c\/li\u003e\n\u003cli\u003eFeed-Thru Connection: Enables easy installation and secure wiring termination.\u003c\/li\u003e\n\u003cli\u003eHigh Interrupting Rating: Rated 10 kAIC at 240V for enhanced electrical safety.\u003c\/li\u003e\n\u003cli\u003eNon-Interchangeable Trip Unit: Ensures consistent and factory-calibrated performance.\u003c\/li\u003e\n\u003cli\u003eCompact Dimensions: Saves space in tight panel installations with a slim 2.75\" width.\u003c\/li\u003e\n\u003cli\u003eRugged Molded Case Design: Built for long-lasting operation in harsh environments.\u003c\/li\u003e\n\u003cli\u003eUL and CSA Certified: Tested and approved for safety and reliability compliance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe TQD22100WL delivers the reliability and precision required for effective circuit protection in residential, commercial, and industrial power systems.\u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":49105082253568,"sku":"TQD22100WL","price":1359.75,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0388\/5331\/2557\/files\/TQD22100_7671_clipped_rev_1__46020.1538841925.jpg?v=1785539709","url":"https:\/\/alotechparts.com\/products\/tqd22100wl-general-electric-100a-2-pole-120240v-thermal-magnetic-molded-case-circuit-breaker","provider":"Alo Tech Solutions","version":"1.0","type":"link"}