{"product_id":"thqc1120gf-general-electric-1-pole-circuit-breaker","title":"THQC1120GF | General Electric 1 Pole Circuit Breaker","description":"\u003ch4\u003eDescription \u003c\/h4\u003e\n\u003cp\u003eThe THQC1120GF is a single-pole, 20 Amp GFCI circuit breaker from GE, offering thermal magnetic protection and ground fault interruption. It features a plug-in design and is rated for 120 V systems with a 10 kAIC interrupting capacity.\u003c\/p\u003e\n\u003cp data-start=\"284\" data-end=\"574\" class=\"\"\u003e \u003c\/p\u003e\n\u003cp data-start=\"284\" data-end=\"574\" class=\"\"\u003e \u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications \u003c\/h4\u003e\n\u003ctable width=\"100%\" style=\"height: 462.329px; width: 100%;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 29.875px;\"\u003e\n\u003cth style=\"width: 34.5455%; text-align: left; height: 29.875px;\" class=\"text-left text-body1 text-bold py-10 pr-10 desktop:pr-[10rem] desktop:text-nowrap\"\u003eCondition\u003c\/th\u003e\n\u003ctd style=\"width: 65.0909%; height: 29.875px;\" class=\"text-left text-body1 py-10 desktop:w-[60%]\"\u003eNew\/Never Used Surplus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 30.9375px;\"\u003e\n\u003cth style=\"width: 34.5455%; text-align: left; height: 30.9375px;\" class=\"text-left text-body1 text-bold py-10 pr-10 desktop:pr-[10rem] desktop:text-nowrap\"\u003eBrand\u003c\/th\u003e\n\u003ctd style=\"width: 65.0909%; height: 30.9375px;\" class=\"text-left text-body1 py-10 desktop:w-[60%]\"\u003e\u003cspan data-sheets-root=\"1\"\u003e\u003cspan\u003eGeneral Electric\u003c\/span\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 28.5625px;\"\u003e\n\u003cth style=\"width: 34.5455%; text-align: left; height: 28.5625px;\"\u003eCategory\u003c\/th\u003e\n\u003ctd style=\"width: 65.0909%; height: 28.5625px;\"\u003e\n\u003cdiv class=\"mt-1 md:mt-0 column-left basis-2\/4 divide-y divide-rad-gray-10 border-b-[0.0625rem] border-rad-gray-10 md:border-0\"\u003e\n\u003cdiv class=\"flex gap-[1.75rem] md:gap-x-0 xl:gap-x-[1.875rem]\"\u003e\n\u003cdiv class=\"text-body-4 w-full font-light py-5 pl-4 md:py-6 md:pl-6 text-rad-gray-70\"\u003e\n\u003cdiv class=\"max-w-[8rem] break-words\"\u003e\n\u003cspan\u003e\u003c\/span\u003e\u003cspan\u003eCircuit Breaker\u003c\/span\u003e\u003cbr\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003cth style=\"width: 34.5455%; text-align: left; height: 19.5938px;\"\u003e\u003cspan\u003ePart Number\u003c\/span\u003e\u003c\/th\u003e\n\u003ctd style=\"width: 65.0909%; height: 19.5938px;\"\u003e\u003cspan data-sheets-root=\"1\"\u003eTHQC1120GF\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 24.6875px;\"\u003e\n\u003cth style=\"width: 34.5455%; text-align: left; height: 24.6875px;\"\u003e\u003cspan\u003eSubcategory\u003c\/span\u003e\u003c\/th\u003e\n\u003ctd style=\"width: 65.0909%; height: 24.6875px;\"\u003e\u003cspan data-sheets-root=\"1\"\u003e\u003cspan\u003ePanel Mount Circuit Breaker\u003c\/span\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003cth style=\"width: 34.5455%; text-align: left; height: 19.5938px;\" class=\"text-left text-body1 text-bold py-10 pr-10 desktop:pr-[10rem] desktop:text-nowrap\"\u003eSeries\u003c\/th\u003e\n\u003ctd style=\"width: 65.0909%; height: 19.5938px;\" class=\"text-left text-body1 py-10 desktop:w-[60%]\"\u003e\u003cspan\u003eTHQC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 30.625px;\"\u003e\n\u003cth style=\"width: 34.5455%; text-align: left; height: 30.625px;\" class=\"text-left text-body1 text-bold py-10 pr-10 desktop:pr-[10rem] desktop:text-nowrap\"\u003eAmperage\u003c\/th\u003e\n\u003ctd style=\"width: 65.0909%; height: 30.625px;\" class=\"text-left text-body1 py-10 desktop:w-[60%]\"\u003e20 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 34.2969px;\"\u003e\n\u003cth style=\"width: 34.5455%; text-align: left; height: 34.2969px;\" class=\"text-left text-body1 text-bold py-10 pr-10 desktop:pr-[10rem] desktop:text-nowrap\"\u003eVoltage Rating\u003c\/th\u003e\n\u003ctd style=\"width: 65.0909%; height: 34.2969px;\" class=\"text-left text-body1 py-10 desktop:w-[60%]\"\u003e120 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003cth style=\"width: 34.5455%; text-align: left; height: 39.1875px;\" class=\"text-left text-body1 text-bold py-10 pr-10 desktop:pr-[10rem] desktop:text-nowrap\"\u003eNumber of Poles\u003c\/th\u003e\n\u003ctd style=\"width: 65.0909%; height: 39.1875px;\" class=\"text-left text-body1 py-10 desktop:w-[60%]\"\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 25.625px;\"\u003e\n\u003cth style=\"width: 34.5455%; text-align: left; height: 25.625px;\" class=\"text-left text-body1 text-bold py-10 pr-10 desktop:pr-[10rem] desktop:text-nowrap\"\u003ePhase\u003c\/th\u003e\n\u003ctd style=\"width: 65.0909%; height: 25.625px;\" class=\"text-left text-body1 py-10 desktop:w-[60%]\"\u003eSingle-phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003cth style=\"width: 34.5455%; text-align: left; height: 39.1875px;\" class=\"text-left text-body1 text-bold py-10 pr-10 desktop:pr-[10rem] desktop:text-nowrap\"\u003eInterrupting Capacity\u003c\/th\u003e\n\u003ctd style=\"width: 65.0909%; height: 39.1875px;\" class=\"text-left text-body1 py-10 desktop:w-[60%]\"\u003e10 kAIC at 120 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003cth style=\"width: 34.5455%; text-align: left; height: 19.5938px;\" class=\"text-left text-body1 text-bold py-10 pr-10 desktop:pr-[10rem] desktop:text-nowrap\"\u003eProtection Type\u003c\/th\u003e\n\u003ctd style=\"width: 65.0909%; height: 19.5938px;\" class=\"text-left text-body1 py-10 desktop:w-[60%]\"\u003eThermal Magnetic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003cth style=\"width: 34.5455%; text-align: left; height: 19.5938px;\"\u003eTrip Functions\u003c\/th\u003e\n\u003ctd style=\"width: 65.0909%; height: 19.5938px;\"\u003eLI (Long-Time and Instantaneous)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22.5938px;\"\u003e\n\u003cth style=\"width: 34.5455%; text-align: left; height: 22.5938px;\"\u003eCircuit Breaker Type\u003c\/th\u003e\n\u003ctd style=\"width: 65.0909%; height: 22.5938px;\"\u003eGFCI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003cth style=\"width: 34.5455%; text-align: left; height: 19.5938px;\"\u003eFrame Type\u003c\/th\u003e\n\u003ctd style=\"width: 65.0909%; height: 19.5938px;\"\u003eTHQC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003cth style=\"width: 34.5455%; text-align: left; height: 19.5938px;\"\u003eConnection Type\u003c\/th\u003e\n\u003ctd style=\"width: 65.0909%; height: 19.5938px;\"\u003ePlug-In\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003cth style=\"width: 34.5455%; text-align: left; height: 19.5938px;\"\u003eCertification\u003c\/th\u003e\n\u003ctd style=\"width: 65.0909%; height: 19.5938px;\"\u003eUL Listed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003cth style=\"width: 34.5455%; text-align: left; height: 19.5938px;\"\u003eWeight\u003c\/th\u003e\n\u003ctd style=\"width: 65.0909%; height: 19.5938px;\"\u003e\u003cspan\u003e0.53 lbs\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003cspan style=\"font-size: 0.875rem;\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eInformation About \u003cspan data-sheets-root=\"1\"\u003eTHQC1120GF\u003c\/span\u003e\n\u003c\/h4\u003e\n\u003cp\u003eThe THQC1120GF is part of GE's THQC series and delivers reliable thermal-magnetic circuit protection with integrated ground fault circuit interruption (GFCI) for enhanced safety. Designed for single-phase, 1-pole applications at 120 volts, this breaker is suited for protecting personnel and equipment in residential and commercial systems. With a 20 Amp rating, it supports lighting, outlet, and general load circuits while monitoring leakage current to ground. The plug-in frame type allows fast installation into compatible load centers, and the unit supports LI tripping functions (Long-Time and Instantaneous) for overload and short-circuit response. It meets UL certification and handles up to 10 kAIC at 120 V, ensuring robust performance in standard protection environments.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eGround Fault Circuit Interruption (GFCI): Integrated GFCI function protects against electrical shock hazards by detecting ground leakage current, essential for wet or high-risk environments.\u003c\/li\u003e\n\u003cli\u003eThermal Magnetic Protection: Built-in long-time and instantaneous tripping mechanisms respond to overloads and short circuits, preserving system safety and preventing damage.\u003c\/li\u003e\n\u003cli\u003eCompact Single-Pole Design: Rated for 120 V single-phase systems and sized for minimal space in panelboards or load centers, suitable for residential and light commercial use.\u003c\/li\u003e\n\u003cli\u003eHigh Interrupting Capacity: With a 10 kAIC rating at 120 V, this breaker can safely interrupt significant fault currents without system failure or hazard.\u003c\/li\u003e\n\u003cli\u003ePlug-In Mounting: Designed for easy and secure installation into compatible THQC load centers, reducing labor time and ensuring stable electrical connections.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe THQC1120GF combines personnel protection, circuit integrity, and compact installation, making it an ideal solution for GFCI-required branch circuits.\u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":49105296130304,"sku":"THQC1120GF","price":149.94,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0388\/5331\/2557\/files\/THQC1120GF-new-1_400x_0d80b3f8-6a7c-4840-81ea-381441c8374b.jpg?v=1785544378","url":"https:\/\/alotechparts.com\/products\/thqc1120gf-general-electric-1-pole-circuit-breaker","provider":"Alo Tech Solutions","version":"1.0","type":"link"}