{"product_id":"th-cct11-compact-spectrometer-visible-350-700-nm-05-nm-resolution","title":"TH-CCT11 - Compact Spectrometer, Visible, 350 - 700 nm, \u003c0.5 nm Resolution","description":"\u003cp\u003e\u003cstrong\u003eTH-CCT11 - Compact Spectrometer, Visible, 350 - 700 nm, \u0026lt;0.5 nm Resolution\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eCompact CMOS Spectrometers provide a portable, high-performance solution for wavelength analysis in a crossed Czerny-Turner design.\u003c\/p\u003e\n\u003cp\u003eAvailable in three wavelength ranges (200–1000 nm, 350–700 nm, and 500–1000 nm) with resolutions from \u0026lt;0.5 to \u0026lt;2 nm, these spectrometers are wavelength calibrated, amplitude corrected, and shipped with a calibration report and test data.\u003c\/p\u003e\n\u003cp\u003eThey feature PC control via USB or Ethernet, accept SMA905 fiber inputs, and can be paired with optional cosine correctors for free-space measurements. Ideal for precision laboratory or field applications, We recommend annual recalibration or recalibration when using new patch cables.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Benefits\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eCompact, portable crossed Czerny-Turner spectrometer design\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eChoose from three wavelength ranges: 200–1000 nm, 350–700 nm, 500–1000 nm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHigh resolution: \u0026lt;0.5 to \u0026lt;2 nm (model dependent)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePre-calibrated with amplitude correction and included test data\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePC-controlled via USB or Ethernet connection\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSMA905 fiber input; optional cosine corrector for free-space applications\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAnnual recalibration service available for optimal accuracy\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eType: CMOS-based crossed Czerny-Turner spectrometer\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWavelength Ranges: 200–1000 nm, 350–700 nm, 500–1000 nm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eResolution: \u0026lt;0.5 to \u0026lt;2 nm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eInput Port: SMA905 connectorized fibers\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eConnectivity: USB or Ethernet\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCalibration: Wavelength calibrated and amplitude corrected, calibration report included\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOptional Accessory: CCSB1 cosine corrector for free-space use\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eSpecs\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eAll technical data are valid at 23 ± 5 °C, at 45 ± 15% relative humidity (non-condensing), and when the spectrometer is used in combination with the included fiber patch cables.\u003c\/p\u003e\n\u003ctable width=\"100%\" class=\"SpecTable\" cellspacing=\"0\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth valign=\"top\" align=\"left\"\u003eItem #\u003c\/th\u003e\n\u003cth valign=\"top\" align=\"center\"\u003eCCT10\u003c\/th\u003e\n\u003cth valign=\"top\" align=\"center\"\u003eCCT11\u003c\/th\u003e\n\u003cth valign=\"top\" align=\"center\"\u003eCCT12\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd valign=\"middle\" colspan=\"4\" class=\"subhead\" align=\"left\"\u003eOptical Specs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"middle\" align=\"left\"\u003e\u003cstrong\u003eWavelength Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd valign=\"middle\" align=\"center\"\u003e200 - 1000 nm\u003c\/td\u003e\n\u003ctd valign=\"middle\" align=\"center\"\u003e350 - 700 nm\u003c\/td\u003e\n\u003ctd valign=\"middle\" align=\"center\"\u003e500 - 1000 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"middle\" align=\"left\"\u003e\u003cstrong\u003eResolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd valign=\"middle\" align=\"center\"\u003e\u0026lt;2.0 nm\u003c\/td\u003e\n\u003ctd valign=\"middle\" align=\"center\"\u003e\u0026lt;0.5 nm\u003c\/td\u003e\n\u003ctd valign=\"middle\" align=\"center\"\u003e\u0026lt;0.6 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"middle\" align=\"left\"\u003e\u003cstrong\u003eSlit (W x H)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd valign=\"middle\" colspan=\"3\" align=\"center\"\u003e20 µm x 1 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003e\u003cstrong\u003eNumber of Pixels on Detector\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e2048\u003c\/td\u003e\n\u003ctd colspan=\"2\" align=\"center\"\u003e4096\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003e\u003cstrong\u003eDetector Technology\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"3\" align=\"center\"\u003eCMOS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003e\u003cstrong\u003eDark Noise (RMS)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e12 Counts\u003c\/td\u003e\n\u003ctd colspan=\"2\" align=\"center\"\u003e14 Counts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003e\u003cstrong\u003eScan Rate (GUI Limited)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"3\" headers=\"th121A01400001\" align=\"center\"\u003e35 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003e\u003cstrong\u003eStray Light\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e0.2 %\u003c\/td\u003e\n\u003ctd colspan=\"2\" align=\"center\"\u003e0.3%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003e\u003cstrong\u003eInternal Shutter Switching Time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"3\" align=\"center\"\u003e\u0026lt;10 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003e\u003cstrong\u003eFiber Connector\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"3\" align=\"center\"\u003eSMA 905\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"middle\" colspan=\"4\" class=\"subhead\" align=\"left\"\u003eSensor Specs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"middle\" align=\"left\"\u003e\u003cstrong\u003eIntegration Time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"3\" valign=\"middle\" align=\"center\"\u003e0.01 - 30 000 ms (10 µs - 30 s)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"middle\" align=\"left\"\u003e\u003cstrong\u003eInternal Average\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd valign=\"middle\" colspan=\"3\" align=\"center\"\u003e10 000 frames\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"middle\" align=\"left\"\u003e\u003cstrong\u003eSignal to Noise Ratio\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd valign=\"middle\" align=\"center\"\u003e330:1\u003c\/td\u003e\n\u003ctd colspan=\"2\" valign=\"middle\" align=\"center\"\u003e300:1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"middle\" align=\"left\"\u003e\u003cstrong\u003eDynamic Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd valign=\"middle\" align=\"center\"\u003e5100\u003c\/td\u003e\n\u003ctd colspan=\"2\" valign=\"middle\" align=\"center\"\u003e4500\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"middle\" colspan=\"4\" class=\"subhead\" align=\"left\"\u003eTrigger Specs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"middle\" align=\"left\"\u003e\u003cstrong\u003eTrigger Input and Output Connectors\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd valign=\"middle\" colspan=\"3\" align=\"center\"\u003eFemale SMA Connectors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"middle\" align=\"left\"\u003e\u003cstrong\u003eTrigger Level\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd valign=\"middle\" colspan=\"3\" align=\"center\"\u003e3.3 V TTL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"middle\" align=\"left\"\u003e\u003cstrong\u003eTrigger Jitter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd valign=\"middle\" colspan=\"3\" align=\"center\"\u003e1 µs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"middle\" colspan=\"4\" class=\"subhead\" align=\"left\"\u003eGeneral Specs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"middle\" align=\"left\"\u003e\u003cstrong\u003eInterface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"3\" valign=\"middle\" align=\"center\"\u003eUSB 2.0 or Higher, Ethernet IPv4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"middle\" align=\"left\"\u003e\u003cstrong\u003eOperating Temperature Range\u003csup\u003ea\u003c\/sup\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"3\" valign=\"middle\" align=\"center\"\u003e0 °C to 40 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"middle\" align=\"left\"\u003e\u003cstrong\u003eStorage Temperature Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"3\" valign=\"middle\" align=\"center\"\u003e0 °C to 40 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"middle\" align=\"left\"\u003e\u003cstrong\u003eDimensions (L x W x H)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd valign=\"middle\" colspan=\"3\" align=\"center\"\u003e112.0 mm x 93.8 mm x 41.5 mm (4.41\" x 3.69\" x 1.63\")\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"middle\" align=\"left\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd valign=\"middle\" colspan=\"3\" align=\"center\"\u003e0.5 kg (1.1 lbs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"4\" class=\"subhead\"\u003eIncluded Patch Cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003e\u003cstrong\u003ePatch Cable Item #\u003csup\u003eb\u003c\/sup\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e\u003ca data-partnumber=\"M111L02\" title=\"M111L02\" class=\"quickview\"\u003eM111L02\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e-\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e\n\u003ca data-partnumber=\"M14L02\" title=\"M14L02\" class=\"quickview\"\u003eM14L02\u003c\/a\u003e\u003csup\u003ec\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003e\u003cstrong\u003eFiber Item #\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e\u003ca data-partnumber=\"FG105ACA\" title=\"FG105ACA\" class=\"quickview\"\u003eFG105ACA\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e\u003ca data-partnumber=\"FG050UGA\" title=\"FG050UGA\" class=\"quickview\"\u003eFG050UGA\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e\u003ca data-partnumber=\"FG050LGA\" title=\"FG050LGA\" class=\"quickview\"\u003eFG050LGA\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003e\u003cstrong\u003eCore Diameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e105 +1\/-3 µm\u003c\/td\u003e\n\u003ctd colspan=\"2\" align=\"center\"\u003e50 ± 1 µm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003e\u003cstrong\u003eCladding Diameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"3\" align=\"center\"\u003e125 +1\/-2 µm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003e\u003cstrong\u003eCoating Diameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"3\" align=\"center\"\u003e250 ± 10 µm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003e\u003cstrong\u003eNA\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"3\" headers=\"th121A01400001\" align=\"center\"\u003e0.22 ± 0.02\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003e\u003cstrong\u003eWavelength Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e180 to 1200 nm\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e250 to 1200 nm\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e400 to 2400 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003e\u003cstrong\u003eConnectors\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"3\" align=\"center\"\u003eSMA905\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr valign=\"top\" align=\"left\"\u003e\n\u003ctd\u003e\u003cstrong\u003ePatch Cable Length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"3\" align=\"center\"\u003e2 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cul class=\"tableFooter\"\u003e\n\u003cli\u003eNon-condensing\u003c\/li\u003e\n\u003cli\u003eIf the fiber patch cable is switched or replaced, the spectrometer will need to be factory recalibrated to update the amplitude correction. We offer a factory recalibration service, which can be ordered by scrolling to the bottom of the page and selecting Item # CAL-CCT.\u003c\/li\u003e\n\u003cli\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003ca data-partnumber=\"M16L01\" title=\"M16L01\" class=\"quickview\"\u003eM16L01\u003c\/a\u003e\u003cspan\u003e \u003c\/span\u003eSMA to FC\/PC fiber patch cable uses the same FG050LGA fiber as the M14L02 patch cable included with CCT12 spectrometers. Each spectrometer's amplitude correction is accurate only with the included patch cable.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003cp\u003e\u003cstrong\u003eCompact CMOS Spectrometers – Features\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eModels available for broadband, visible, and NIR spectral ranges\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eInternal shutter (\u0026lt;10 ms switching time) allows fast background subtraction\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAmplitude corrected and wavelength calibrated\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eInput and output triggers with low jitter (1 μs) for external synchronization (TTL)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePC connection via USB or Ethernet interface\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRugged crossed Czerny-Turner spectrometer design\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e2048 or 4096 pixel CMOS line array\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIncludes multimode fiber patch cable\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCompact size: 112.0 mm x 93.8 mm x 41.5 mm (4.41\" x 3.69\" x 1.63\")\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHorizontal or vertical mounting options:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eHorizontal mounting using two through holes for 1\/4\"-20 (M6) screws\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eTwo slots for vertical mounting with CL4 clamps\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCosine correctors available separately for free-space input\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRound-to-linear fiber bundles optimized for spectrometer use also available\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThese compact crossed Czerny-Turner spectrometers are designed for high-performance measurements in a small footprint, roughly the size of a portable hard drive. Models are available with spectral ranges of 200–1000 nm, 350–700 nm, and 500–1000 nm, with resolutions from better than 2 nm down to sub-nanometer depending on the model. Each unit comes wavelength calibrated and amplitude corrected and is shipped with a calibration report and test data.\u003c\/p\u003e\n\u003cp\u003eDespite their compact design, these spectrometers offer features normally found in larger, more expensive systems. They can be synchronized with other devices using TTL trigger input and output with low jitter (1 μs), making them well-suited for precise timing applications such as Laser-Induced Breakdown Spectroscopy. An internal shutter allows rapid background subtraction, while the included multimode fiber patch cable makes integration into fiber-based systems straightforward.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMounting Options\u003c\/strong\u003e\u003cbr\u003eFor stability and flexibility, units can be mounted horizontally using two through holes for standard 1\/4\"-20 (M6) screws, or vertically using CL4 clamps.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSoftware Package\u003c\/strong\u003e\u003cbr\u003eThe included software provides full PC control via USB or Ethernet, with a graphical user interface (GUI) as well as drivers for .NET, Python, and NI LabVIEW. Users can view spectra, background, and peaks in a single window, apply algorithms for smoothing, averaging, absorption, or transmission, and compare results against stored profiles. Both user wavelength calibration and factory calibration are supported.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAccessories\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cem\u003eCosine Correctors\u003c\/em\u003e: Attach to SMA connectorized fibers or directly to the input port for free-space measurements.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cem\u003eFiber Bundles\u003c\/em\u003e: Linear-to-round fiber bundles optimized for spectrometer use increase signal levels by matching the slit geometry. Reflection probe fiber bundles are also available for spectroscopy applications.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cem\u003ePatch Cables\u003c\/em\u003e: Standard SMA-to-SMA patch cable included; additional cables and custom configurations available separately.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eRecalibration Service\u003c\/strong\u003e\u003cbr\u003eAnnual recalibration is recommended to maintain accuracy. While user wavelength calibration can be performed through the software, amplitude correction requires factory recalibration. Recalibration is also recommended when using a different patch cable than the one originally supplied, as the cable influences amplitude correction.\u003c\/p\u003e","brand":"Fosco Connect","offers":[{"title":"Default Title","offer_id":49083393900800,"sku":"TH-CCT11","price":10004.5,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0388\/5331\/2557\/files\/CCt11-xl-fotor-20250910173557.png?v=1785198530","url":"https:\/\/alotechparts.com\/products\/th-cct11-compact-spectrometer-visible-350-700-nm-05-nm-resolution","provider":"Alo Tech Solutions","version":"1.0","type":"link"}