{"product_id":"t2536161s-acme-electric-low-voltage-distribution-transformer","title":"T2536161S | Acme Electric Low Voltage Distribution Transformer","description":"\u003ch4\u003eDescription \u003c\/h4\u003e\n\u003cp data-start=\"144\" data-end=\"396\"\u003eThe Acme Electric T2536161S is a single-phase, dry-type low-voltage distribution transformer built for reliable service in industrial and commercial environments.\u003c\/p\u003e\n\u003cp data-start=\"284\" data-end=\"574\" class=\"\"\u003e \u003c\/p\u003e\n\u003cp data-start=\"284\" data-end=\"574\" class=\"\"\u003e \u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications \u003c\/h4\u003e\n\u003ctable style=\"width: 100%; height: 842.8px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 34.6684%; height: 19.6px;\"\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.1621%; height: 19.6px;\"\u003eNew\/Never Used Surplus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 34.6684%; height: 19.6px;\"\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.1621%; height: 19.6px;\"\u003eAcme Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 34.6684%; height: 19.6px;\"\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.1621%; height: 19.6px;\"\u003e\u003cspan\u003eTransformers\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 34.6684%; height: 19.6px;\"\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.1621%; height: 19.6px;\"\u003eT2536161S\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 34.6684%; height: 19.6px;\"\u003e\u003cstrong\u003eSubcategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.1621%; height: 19.6px;\"\u003e\u003cspan\u003eDry Transformer\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 34.6684%; height: 19.6px;\"\u003e\u003cstrong\u003eType\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.1621%; height: 19.6px;\"\u003eGeneral Purpose Transformer, Encapsulated Core\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 34.6684%; height: 19.6px;\"\u003e\u003cstrong\u003eKVA Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.1621%; height: 19.6px;\"\u003e10 kVA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 34.6684%; height: 19.6px;\"\u003e\u003cstrong\u003ePhase\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.1621%; height: 19.6px;\"\u003eSingle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 34.6684%; height: 19.6px;\"\u003e\u003cstrong\u003eFrequency Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.1621%; height: 19.6px;\"\u003e60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 34.6684%; height: 19.6px;\"\u003e\u003cstrong\u003ePrimary Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.1621%; height: 19.6px;\"\u003e600 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 34.6684%; height: 19.6px;\"\u003e\u003cstrong\u003eSecondary Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.1621%; height: 19.6px;\"\u003e120\/240 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 34.6684%; height: 19.6px;\"\u003e\u003cstrong\u003eTaps % Steps\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.1621%; height: 19.6px;\"\u003e5%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 34.6684%; height: 19.6px;\"\u003e\u003cstrong\u003eBNFC Taps\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.1621%; height: 19.6px;\"\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 34.6684%; height: 19.6px;\"\u003e\u003cstrong\u003eConfiguration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.1621%; height: 19.6px;\"\u003eElectrostatic Shield – Shielded\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 34.6684%; height: 19.6px;\"\u003e\u003cstrong\u003eWinding Material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.1621%; height: 19.6px;\"\u003eAluminum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 34.6684%; height: 19.6px;\"\u003e\u003cstrong\u003eMaterial Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.1621%; height: 19.6px;\"\u003eZFIN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 34.6684%; height: 19.6px;\"\u003e\u003cstrong\u003eMax Temperature Rise\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.1621%; height: 19.6px;\"\u003e115°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 34.6684%; height: 19.6px;\"\u003e\u003cstrong\u003eUL Insulation Class\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.1621%; height: 19.6px;\"\u003e180°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 34.6684%; height: 19.6px;\"\u003e\u003cstrong\u003eNEMA Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.1621%; height: 19.6px;\"\u003eNEMA 3R\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 34.6684%; height: 19.6px;\"\u003e\u003cstrong\u003eUL Standard\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.1621%; height: 19.6px;\"\u003eUL 506\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 34.6684%; height: 19.6px;\"\u003e\u003cstrong\u003eCSA Standard\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.1621%; height: 19.6px;\"\u003eC22.2 No. 47\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 34.6684%; height: 19.6px;\"\u003e\u003cstrong\u003eMounting Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.1621%; height: 19.6px;\"\u003eWall\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 34.6684%; height: 19.6px;\"\u003e\u003cstrong\u003eMade in USA\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.1621%; height: 19.6px;\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 34.6684%; height: 19.6px;\"\u003e\u003cstrong\u003eDimensions (L × W × H)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.1621%; height: 19.6px;\"\u003e10.84 in × 13.5 in × 15.19 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 34.6684%; height: 19.6px;\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.1621%; height: 19.6px;\"\u003e125 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eInformation About T2536161S\u003c\/h4\u003e\n\u003cp\u003eThe Acme Electric T2536161S is a single-phase, dry-type general purpose distribution transformer designed for dependable voltage conversion in industrial and commercial applications. Rated at 10 kVA, it steps down 600 V primary voltage to 120\/240 V secondary, delivering efficient and stable power. Its encapsulated core and coil construction is housed in a NEMA 3R enclosure for both indoor and outdoor wall-mounted use. Featuring aluminum windings, a 5% tap adjustment, and an electrostatic shield, it ensures reduced electrical noise and long service life. With a 115 °C maximum temperature rise and Class 180 °C insulation, it meets UL 506 and CSA C22.2 No. 47 standards for safety and performance.\u003c\/p\u003e\n\u003ch4\u003eKey Features:\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eVersatile Voltage Conversion: 600 V primary to 120\/240 V secondary for a range of load requirements.\u003c\/li\u003e\n\u003cli\u003eDurable Enclosure: NEMA 3R rated for indoor\/outdoor environments.\u003c\/li\u003e\n\u003cli\u003eQuiet Operation: Below NEMA sound-level standards, suitable for noise-sensitive areas.\u003c\/li\u003e\n\u003cli\u003eElectrostatic Shield: Provides enhanced protection against electrical interference.\u003c\/li\u003e\n\u003cli\u003eEncapsulated Construction: Protects windings from dust, moisture, and corrosion.\u003c\/li\u003e\n\u003cli\u003eIndustrial Grade: Aluminum windings, Class 180 °C insulation, and 115 °C rise for reliability.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe T2536161S combines rugged construction with efficient operation, making it a trusted choice for clean, reliable power distribution in demanding environments.\u003c\/p\u003e","brand":"Acme Electric","offers":[{"title":"Default Title","offer_id":49105250255104,"sku":"T2536161S","price":3608.85,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0388\/5331\/2557\/files\/l_t2536161s.jpg?v=1785543489","url":"https:\/\/alotechparts.com\/products\/t2536161s-acme-electric-low-voltage-distribution-transformer","provider":"Alo Tech Solutions","version":"1.0","type":"link"}