{"product_id":"sxl-xmain-siemens-sxl-x-fire-alarm-control-panel-main-board-assembly","title":"SXL-XMAIN | Siemens SXL-X Fire Alarm Control Panel Main Board Assembly","description":"\u003ch4\u003eDescription \u003c\/h4\u003e\n\u003cp data-end=\"396\" data-start=\"144\"\u003eThe Siemens SXL-XMAIN Fire Alarm Control Panel Board is a microprocessor-based main circuit assembly designed for the SXL-X series. It provides four conventional initiating zones (expandable to eight) with field programmability, power-limited circuits, and advanced supervision features for small to mid-sized fire alarm installations.\u003c\/p\u003e\n\u003cp class=\"\" data-end=\"574\" data-start=\"284\"\u003e \u003c\/p\u003e\n\u003cp class=\"\" data-end=\"574\" data-start=\"284\"\u003e \u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications \u003c\/h4\u003e\n\u003ctable style=\"width: 99.964%; height: 431.2px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 23.2417%; height: 19.6px;\"\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 76.6251%; height: 19.6px;\"\u003eNew\/Never Used Surplus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 23.2417%; height: 19.6px;\"\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 76.6251%; height: 19.6px;\"\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 23.2417%; height: 19.6px;\"\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 76.6251%; height: 19.6px;\"\u003eFire Alarm Components\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 23.2417%; height: 19.6px;\"\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 76.6251%; height: 19.6px;\"\u003eSXL-XMAIN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 23.2417%; height: 19.6px;\"\u003e\u003cstrong\u003eSubcategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 76.6251%; height: 19.6px;\"\u003eMain Control Board Assembly\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 23.2417%; height: 19.6px;\"\u003e\u003cstrong\u003eSystem Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 76.6251%; height: 19.6px;\"\u003eSXL-X Conventional Fire Alarm Control Panel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 23.2417%; height: 19.6px;\"\u003e\u003cstrong\u003eCircuit Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 76.6251%; height: 19.6px;\"\u003eMicroprocessor-Based Control PCB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 23.2417%; height: 19.6px;\"\u003e\u003cstrong\u003eZones\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 76.6251%; height: 19.6px;\"\u003e4 Style B (Class B) Zones, Expandable to 8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 23.2417%; height: 19.6px;\"\u003e\u003cstrong\u003eCompatibility\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 76.6251%; height: 19.6px;\"\u003eSiemens SXL-X Series FACPs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.2px;\"\u003e\n\u003ctd style=\"width: 23.2417%; height: 39.2px;\"\u003e\u003cstrong\u003eSupported Devices\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 76.6251%; height: 39.2px;\"\u003eIonization, Photoelectric, and Photo-Thermal Detectors; MS Series Manual Stations\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.2px;\"\u003e\n\u003ctd style=\"width: 23.2417%; height: 39.2px;\"\u003e\u003cstrong\u003ePower-Limited Circuits\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 76.6251%; height: 39.2px;\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 23.2417%; height: 19.6px;\"\u003e\u003cstrong\u003eProgramming\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 76.6251%; height: 19.6px;\"\u003eField Programmable with Onboard Controls\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 23.2417%; height: 19.6px;\"\u003e\u003cstrong\u003eSupervision\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 76.6251%; height: 19.6px;\"\u003eDynamic Zone and Circuit Supervision\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 23.2417%; height: 19.6px;\"\u003e\u003cstrong\u003eAnnunciation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 76.6251%; height: 19.6px;\"\u003eRemote Annunciator Compatibility\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 23.2417%; height: 19.6px;\"\u003e\u003cstrong\u003eTesting Mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 76.6251%; height: 19.6px;\"\u003eOne-Person Walk Test\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 23.2417%; height: 19.6px;\"\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 76.6251%; height: 19.6px;\"\u003eSmall to Mid-Size Commercial and Residential Buildings\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 23.2417%; height: 19.6px;\"\u003e\u003cstrong\u003eAuxiliary Power\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 76.6251%; height: 19.6px;\"\u003eRemote Bell Power Output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 23.2417%; height: 19.6px;\"\u003e\u003cstrong\u003eCompliance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 76.6251%; height: 19.6px;\"\u003eADA Signaling and UL Fire Alarm Standards\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 23.2417%; height: 19.6px;\"\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 76.6251%; height: 19.6px;\"\u003e16 × 13 × 4 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 23.2417%; height: 19.6px;\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 76.6251%; height: 19.6px;\"\u003e3 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003e\u003cbr\u003e\u003c\/h4\u003e\n\u003ch4\u003eInformation About \u003cspan data-sheets-root=\"1\"\u003eSXL-XMAIN\u003c\/span\u003e\n\u003c\/h4\u003e\n\u003cp\u003eThe SXL-XMAIN serves as the primary printed circuit board (PCB) assembly for Siemens SXL-X Fire Alarm Control Panels. It manages the detection and notification operations of up to four conventional initiating zones, which can be expanded to eight using optional modules. Designed with a power-limited configuration, the board supports multiple Siemens detection devices, including ionization, photoelectric, and photo-thermal sensors. Its microprocessor-based design enables field programmability, efficient supervision, and compatibility with remote annunciation systems. The SXL-XMAIN provides dependable fire detection control for small commercial buildings, hotels, and office complexes requiring a compact yet feature-rich fire alarm solution.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eMicroprocessor-Based Control: Provides precise monitoring and processing of input and output signals across all zones.\u003c\/li\u003e\n\u003cli\u003eExpandable Zone Capacity: Supports four Class B zones, expandable to eight for greater system flexibility.\u003c\/li\u003e\n\u003cli\u003eWide Device Compatibility: Works with Siemens ionization, photoelectric, and thermal detectors, as well as MS manual stations.\u003c\/li\u003e\n\u003cli\u003eField Programmable Interface: Allows quick setup and customization of detection parameters without specialized tools.\u003c\/li\u003e\n\u003cli\u003ePower-Limited Design: Ensures compliance with modern safety and electrical isolation standards.\u003c\/li\u003e\n\u003cli\u003eBuilt-In Testing Functions: One-person test mode simplifies inspection and verification procedures.\u003c\/li\u003e\n\u003cli\u003eRemote Annunciation Support: Compatible with external annunciators for enhanced status visibility.\u003c\/li\u003e\n\u003cli\u003eAuxiliary Bell Power Output: Can supply additional bell power for integration into larger systems like the MXL FACP.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe SXL-XMAIN delivers the reliability and precision required for dependable fire detection and supervision in compact and expandable Siemens fire alarm systems.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":49105145069824,"sku":"SXL-XMAIN","price":2644.53,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0388\/5331\/2557\/files\/s-l1600_fe3b43e0-f180-46f9-b1fc-01fea06f69cd.webp?v=1785541247","url":"https:\/\/alotechparts.com\/products\/sxl-xmain-siemens-sxl-x-fire-alarm-control-panel-main-board-assembly","provider":"Alo Tech Solutions","version":"1.0","type":"link"}