{"product_id":"snac-6-gamewell-fci-supplementary-notification-appliance-circuit-panel-6a-output","title":"SNAC-6 | Gamewell-FCI Supplementary Notification Appliance Circuit Panel, 6A Output","description":"\u003ch4\u003eDescription \u003c\/h4\u003e\n\u003cp data-end=\"396\" data-start=\"144\"\u003eThe Gamewell-FCI SNAC-6 is a supplementary notification appliance circuit panel that provides up to 6 amps of power across multiple Class A or Class B circuits. It integrates with existing notification appliance circuits, offering synchronization, temporal pattern outputs, and full supervision for reliable fire alarm signaling.\u003c\/p\u003e\n\u003cp class=\"\" data-end=\"574\" data-start=\"284\"\u003e \u003c\/p\u003e\n\u003cp class=\"\" data-end=\"574\" data-start=\"284\"\u003e \u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications \u003c\/h4\u003e\n\u003ctable style=\"width: 99.964%; height: 431.2px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 24.158%; height: 19.6px;\"\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 75.5273%; height: 19.6px;\"\u003eNew\/Never Used Surplus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 24.158%; height: 19.6px;\"\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 75.5273%; height: 19.6px;\"\u003eGamewell-FCI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 24.158%; height: 19.6px;\"\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 75.5273%; height: 19.6px;\"\u003eFire Alarm Systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 24.158%; height: 19.6px;\"\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 75.5273%; height: 19.6px;\"\u003eSNAC-6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 24.158%; height: 19.6px;\"\u003e\u003cstrong\u003eSubcategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 75.5273%; height: 19.6px;\"\u003eNAC Panels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 24.158%; height: 19.6px;\"\u003e\u003cstrong\u003eType\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 75.5273%; height: 19.6px;\"\u003eSupplementary notification appliance circuit panel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 24.158%; height: 19.6px;\"\u003e\u003cstrong\u003eOutput Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 75.5273%; height: 19.6px;\"\u003e6 A total\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 24.158%; height: 19.6px;\"\u003e\u003cstrong\u003eOutput Circuits\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 75.5273%; height: 19.6px;\"\u003e2 Class A (Style Z), 4 Class B (Style Y), or 1 Class A + 2 Class B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 24.158%; height: 19.6px;\"\u003e\u003cstrong\u003eInput Source\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 75.5273%; height: 19.6px;\"\u003e1 or 2 existing Class A\/B NACs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 24.158%; height: 19.6px;\"\u003e\u003cstrong\u003eOperating Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 75.5273%; height: 19.6px;\"\u003e9–32 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 24.158%; height: 19.6px;\"\u003e\u003cstrong\u003eOperation Modes\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 75.5273%; height: 19.6px;\"\u003eCoded or non-coded\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.2px;\"\u003e\n\u003ctd style=\"width: 24.158%; height: 39.2px;\"\u003e\u003cstrong\u003eTemporal Pattern\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 75.5273%; height: 39.2px;\"\u003eProgrammable ANSI S3.41 temporal Class B output from non-coded input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 24.158%; height: 19.6px;\"\u003e\u003cstrong\u003eSynchronization\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 75.5273%; height: 19.6px;\"\u003eBuilt-in sync for strobes from 3 manufacturers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.2px;\"\u003e\n\u003ctd style=\"width: 24.158%; height: 39.2px;\"\u003e\u003cstrong\u003eGround Fault Detection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 75.5273%; height: 39.2px;\"\u003eIntegral supervision with ground fault detection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 24.158%; height: 19.6px;\"\u003e\u003cstrong\u003eTrouble Reporting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 75.5273%; height: 19.6px;\"\u003eForm “C” contacts, delayed AC failure indication\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 24.158%; height: 19.6px;\"\u003e\u003cstrong\u003eCompliance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 75.5273%; height: 19.6px;\"\u003eUL Listed fire alarm accessory\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.2px;\"\u003e\n\u003ctd style=\"width: 24.158%; height: 39.2px;\"\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 75.5273%; height: 39.2px;\"\u003eExpands NAC capacity for FCI and other UL Listed fire alarm systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 24.158%; height: 19.6px;\"\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 75.5273%; height: 19.6px;\"\u003e16.00 × 12.25 × 3.00 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 24.158%; height: 19.6px;\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 75.5273%; height: 19.6px;\"\u003e6.5 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003e\u003cbr\u003e\u003c\/h4\u003e\n\u003ch4\u003eInformation About \u003cspan data-sheets-root=\"1\"\u003eSNAC-6\u003c\/span\u003e\n\u003c\/h4\u003e\n\u003cp\u003eThe SNAC-6 is a UL Listed supplementary notification appliance circuit panel engineered to expand the signaling capabilities of fire alarm systems. It provides up to 6 amps of regulated output that can be distributed across Class A or Class B circuits, depending on installation needs. With the ability to synchronize strobes from three leading manufacturers, it ensures consistent visual signaling across facilities. Additional features include ANSI S3.41 temporal pattern outputs, coded\/non-coded operation, ground fault detection, and Form “C” trouble contacts. Designed for compatibility with Gamewell-FCI and other UL Listed control panels, the SNAC-6 enhances both capacity and reliability in life safety applications.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eHigh current output: Provides 6 amps of total NAC power for supporting multiple notification appliances.\u003c\/li\u003e\n\u003cli\u003eFlexible circuit configuration: Supports 2 Class A, 4 Class B, or mixed 1 Class A and 2 Class B circuits to fit system requirements.\u003c\/li\u003e\n\u003cli\u003eInput circuit integration: Activates through one or two existing Class A or B notification appliance circuits for seamless expansion.\u003c\/li\u003e\n\u003cli\u003eCoded and non-coded operation: Allows flexible control options, including compatibility with coded inputs.\u003c\/li\u003e\n\u003cli\u003eProgrammable temporal outputs: Provides ANSI S3.41-compliant temporal Class B outputs from non-coded inputs.\u003c\/li\u003e\n\u003cli\u003eStrobe synchronization: Features built-in synchronization for appliances from three major manufacturers.\u003c\/li\u003e\n\u003cli\u003eSupervised operation: Equipped with ground fault detection to ensure circuit integrity.\u003c\/li\u003e\n\u003cli\u003eTrouble monitoring: Includes Form “C” trouble contacts with delayed AC failure indication for enhanced system reporting.\u003c\/li\u003e\n\u003cli\u003eUL Listed accessory: Approved for use with Gamewell-FCI and other UL Listed fire alarm systems.\u003c\/li\u003e\n\u003cli\u003eDurable enclosure: Measures 16 × 12.25 × 3 inches and weighs 6.5 lbs for dependable installation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe SNAC-6 delivers the reliability and precision required for expanding NAC capacity and synchronization in commercial and institutional fire alarm systems.\u003c\/p\u003e","brand":"Gamewell-FCI","offers":[{"title":"Default Title","offer_id":49105170563328,"sku":"SNAC-6","price":2497.53,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0388\/5331\/2557\/files\/s-l1600_da94514c-48c7-4bfb-b3a5-da344b3b8217.webp?v=1785541806","url":"https:\/\/alotechparts.com\/products\/snac-6-gamewell-fci-supplementary-notification-appliance-circuit-panel-6a-output","provider":"Alo Tech Solutions","version":"1.0","type":"link"}