{"product_id":"skhb36bb1200-general-electric-molded-case-circuit-breaker-1200a-600v-3-pole","title":"SKHB36BB1200 | General Electric Molded Case Circuit Breaker, 1200A, 600V, 3-Pole","description":"\u003ch4\u003eDescription \u003c\/h4\u003e\n\u003cp data-start=\"168\" data-end=\"447\"\u003eThe General Electric SKHB36BB1200 is a molded case circuit breaker designed for high-capacity electrical distribution systems. With a 3-pole, 1200-amp rating, it provides dependable protection against overloads and short circuits in industrial and commercial applications.\u003c\/p\u003e\n\u003cp data-start=\"284\" data-end=\"574\" class=\"\"\u003e \u003c\/p\u003e\n\u003cp data-start=\"284\" data-end=\"574\" class=\"\"\u003e \u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications \u003c\/h4\u003e\n\u003ctable style=\"width: 100%; height: 392px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 31.5828%; height: 19.6px;\"\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 68.2478%; height: 19.6px;\"\u003eNew\/Never Used Surplus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 31.5828%; height: 19.6px;\"\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 68.2478%; height: 19.6px;\"\u003eGeneral Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 31.5828%; height: 19.6px;\"\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 68.2478%; height: 19.6px;\"\u003eElectrical Distribution\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 31.5828%; height: 19.6px;\"\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 68.2478%; height: 19.6px;\"\u003eSKHB36BB1200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 31.5828%; height: 19.6px;\"\u003e\u003cstrong\u003eSubcategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 68.2478%; height: 19.6px;\"\u003eMolded Case Circuit Breaker\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 31.5828%; height: 19.6px;\"\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 68.2478%; height: 19.6px;\"\u003eSKHB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 31.5828%; height: 19.6px;\"\u003e\u003cstrong\u003eBreaker Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 68.2478%; height: 19.6px;\"\u003eMolded Case Circuit Breaker (MCCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 31.5828%; height: 19.6px;\"\u003e\u003cstrong\u003ePoles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 68.2478%; height: 19.6px;\"\u003e3-pole\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 31.5828%; height: 19.6px;\"\u003e\u003cstrong\u003eVoltage Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 68.2478%; height: 19.6px;\"\u003e600 V AC maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 31.5828%; height: 19.6px;\"\u003e\u003cstrong\u003eCurrent Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 68.2478%; height: 19.6px;\"\u003e1200 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 31.5828%; height: 19.6px;\"\u003e\u003cstrong\u003eFrequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 68.2478%; height: 19.6px;\"\u003e50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 31.5828%; height: 19.6px;\"\u003e\u003cstrong\u003eTrip Unit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 68.2478%; height: 19.6px;\"\u003eSolid-state or thermal-magnetic (series dependent)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 31.5828%; height: 19.6px;\"\u003e\u003cstrong\u003eInterrupting Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 68.2478%; height: 19.6px;\"\u003eHigh fault current withstand capability (per UL)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 31.5828%; height: 19.6px;\"\u003e\u003cstrong\u003eMounting Style\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 68.2478%; height: 19.6px;\"\u003ePanelboard or switchboard installation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 31.5828%; height: 19.6px;\"\u003e\u003cstrong\u003eFrame Size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 68.2478%; height: 19.6px;\"\u003eSKHB frame\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 31.5828%; height: 19.6px;\"\u003e\u003cstrong\u003eProtection Features\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 68.2478%; height: 19.6px;\"\u003eOverload and short-circuit protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 31.5828%; height: 19.6px;\"\u003e\u003cstrong\u003eStandards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 68.2478%; height: 19.6px;\"\u003eUL Listed, ANSI\/IEEE compliant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 31.5828%; height: 19.6px;\"\u003e\u003cstrong\u003eApplication Use\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 68.2478%; height: 19.6px;\"\u003eIndustrial, utility, and large commercial distribution\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 31.5828%; height: 19.6px;\"\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 68.2478%; height: 19.6px;\"\u003e-20 °C to +40 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 31.5828%; height: 19.6px;\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 68.2478%; height: 19.6px;\"\u003eApprox. 36 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eInformation About SKHB36BB1200\u003c\/h4\u003e\n\u003cp\u003eThe SKHB36BB1200 is part of GE’s SKHB series of molded case circuit breakers, engineered for reliable power distribution and fault protection. Built with a heavy-duty housing and advanced trip technology, it ensures safe interruption of high fault currents. The breaker is designed for use in switchboards, panelboards, and power distribution units where high amperage protection is required. With UL compliance and robust performance, it is well-suited for utilities, manufacturing plants, and large commercial facilities.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eHigh Amperage Protection: Rated for 1200A, suitable for heavy-duty power systems.\u003c\/li\u003e\n\u003cli\u003eSKHB Series: Part of GE’s molded case breaker family for industrial distribution.\u003c\/li\u003e\n\u003cli\u003e3-Pole Design: Provides balanced protection across three-phase systems.\u003c\/li\u003e\n\u003cli\u003eReliable Interruption: Protects circuits from overloads and short-circuits.\u003c\/li\u003e\n\u003cli\u003eDurable Housing: Molded case construction ensures rugged performance.\u003c\/li\u003e\n\u003cli\u003eUL Listed: Complies with safety and performance standards.\u003c\/li\u003e\n\u003cli\u003eFlexible Applications: Designed for switchboards, panelboards, and distribution units.\u003c\/li\u003e\n\u003cli\u003eIndustrial-Grade Reliability: Built for continuous operation in demanding environments.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe SKHB36BB1200 delivers the reliability and protection required for large-scale electrical distribution systems.\u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":49105208639744,"sku":"SKHB36BB1200","price":7463.19,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0388\/5331\/2557\/files\/Photoroom_20240524_103055.jpg?v=1785542555","url":"https:\/\/alotechparts.com\/products\/skhb36bb1200-general-electric-molded-case-circuit-breaker-1200a-600v-3-pole","provider":"Alo Tech Solutions","version":"1.0","type":"link"}