{"product_id":"sk-zone-6-honeywell-silent-knight-6-zone-addressable-interface-module-for-facps","title":"SK-ZONE-6 | Honeywell Silent Knight 6-Zone Addressable Interface Module for FACPs","description":"\u003ch4\u003eDescription \u003c\/h4\u003e\n\u003cp data-end=\"396\" data-start=\"144\"\u003eThe Honeywell Silent Knight SK-ZONE-6 is an addressable six-zone interface module designed to connect conventional two-wire smoke detector zones to Silent Knight fire alarm control panels (FACPs). It transmits the zone status—normal, open, or alarm—to the control panel for monitoring and supervision. The SK-ZONE-6 provides dependable integration of legacy detection circuits into modern addressable fire alarm systems.\u003c\/p\u003e\n\u003cp class=\"\" data-end=\"574\" data-start=\"284\"\u003e \u003c\/p\u003e\n\u003cp class=\"\" data-end=\"574\" data-start=\"284\"\u003e \u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications \u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNew\/Never Used Surplus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSilent Knight by Honeywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFire Alarm Systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSK-ZONE-6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSubcategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAddressable Interface Modules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFunction\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSix-zone addressable interface for two-wire detectors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCompatibility\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSilent Knight IntelliKnight Series FACPs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Zones\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSix independent supervised inputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWiring Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eClass A or Class B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSLC Loop Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15–32 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eExternal Power Supply\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e18–28 VDC, power-limited\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStandby Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 mA max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAlarm Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e40 mA max (all six LEDs active)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInitiating Device Circuit Resistance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e25 Ω max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRipple Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.1 V RMS max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLED Indicators\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOne per zone input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAddressing Method\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRotary address switches\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e32°F to 120°F (0°C to 48.9°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6.8” H × 5.8” W × 1.0” D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Options\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDual module mounting in IDP-ACB cabinet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUnited States\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.4 lb (6.3 oz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eInformation About \u003cmeta charset=\"utf-8\"\u003e \u003cmeta charset=\"utf-8\"\u003e \u003cspan data-sheets-root=\"1\"\u003eSK-ZONE-6\u003c\/span\u003e\n\u003c\/h4\u003e\n\u003cp\u003eThe SK-ZONE-6 is a six-input interface module that enables IntelliKnight and other Silent Knight Series FACPs to monitor conventional two-wire detector zones. Each input operates independently, sharing a common signaling line circuit (SLC) and external power source while maintaining full supervision. Designed for flexibility, the module supports both Class A and Class B wiring configurations and includes rotary address switches for simplified installation. The SK-ZONE-6 features LED indicators per zone input and allows disabling of up to two unused zones for optimized performance and system configuration.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSix Independent Zone Inputs: Monitors up to six separate conventional detector circuits.\u003c\/li\u003e\n\u003cli\u003eSLC Integration: Converts traditional two-wire loops into addressable SLC circuits for Silent Knight FACPs.\u003c\/li\u003e\n\u003cli\u003eFull Supervision: Continuously monitors zone wiring, detectors, and external power supply for integrity.\u003c\/li\u003e\n\u003cli\u003eFlexible Wiring: Supports both Class A and Class B wiring for varied installation needs.\u003c\/li\u003e\n\u003cli\u003eQuick Installation: Rotary address switches simplify addressing and configuration.\u003c\/li\u003e\n\u003cli\u003eLED Indicators: Provides individual status indication for each input zone.\u003c\/li\u003e\n\u003cli\u003eDisable Option: Up to two unused inputs can be disabled when not required.\u003c\/li\u003e\n\u003cli\u003eCompact Mounting: Fits two modules per IDP-ACB cabinet with included hardware.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe SK-ZONE-6 delivers the reliability and precision required for seamless integration of conventional detection zones into addressable fire alarm systems.\u003c\/p\u003e","brand":"Silent Knight","offers":[{"title":"Default Title","offer_id":49105153720576,"sku":"SK-ZONE-6","price":833.49,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0388\/5331\/2557\/files\/HBT-Fire-SK-ZONE-6-STRAIGHT-HiRes.jpg?v=1785541440","url":"https:\/\/alotechparts.com\/products\/sk-zone-6-honeywell-silent-knight-6-zone-addressable-interface-module-for-facps","provider":"Alo Tech Solutions","version":"1.0","type":"link"}