{"product_id":"s89e1058-honeywell-24v-direct-spark-ignition-control-module-two-rod-system","title":"S89E1058 | Honeywell 24V Direct Spark Ignition Control Module Two-Rod System","description":"\u003ch4\u003eDescription \u003c\/h4\u003e\n\u003cp data-start=\"144\" data-end=\"396\"\u003eThe Honeywell S89E1058 is a 24V direct spark ignition control module designed to manage gas valve operation and ignition sequence in direct spark systems. It operates with a separate 120V spark generator, features a two-rod sensing system, and includes a 4-second ignition trial with automatic lockout protection for safe and reliable burner ignition control.\u003c\/p\u003e\n\u003cp data-start=\"284\" data-end=\"574\" class=\"\"\u003e \u003c\/p\u003e\n\u003cp data-start=\"284\" data-end=\"574\" class=\"\"\u003e \u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications \u003c\/h4\u003e\n\u003ctable style=\"width: 99.964%; height: 588px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 28.7016%; height: 19.6px;\"\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 70.9837%; height: 19.6px;\"\u003eNew\/Never Used Surplus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 28.7016%; height: 19.6px;\"\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 70.9837%; height: 19.6px;\"\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 28.7016%; height: 19.6px;\"\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 70.9837%; height: 19.6px;\"\u003eHeating Controls\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 28.7016%; height: 19.6px;\"\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 70.9837%; height: 19.6px;\"\u003eS89E1058\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 28.7016%; height: 19.6px;\"\u003e\u003cstrong\u003eSubcategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 70.9837%; height: 19.6px;\"\u003eDirect Spark Ignition Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 28.7016%; height: 19.6px;\"\u003e\u003cstrong\u003eControl Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 70.9837%; height: 19.6px;\"\u003e24 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 28.7016%; height: 19.6px;\"\u003e\u003cstrong\u003eFrequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 70.9837%; height: 19.6px;\"\u003e60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 28.7016%; height: 19.6px;\"\u003e\u003cstrong\u003eIgnition Source\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 70.9837%; height: 19.6px;\"\u003eExternal 120 VAC high-voltage spark generator\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 28.7016%; height: 19.6px;\"\u003e\u003cstrong\u003eIgnition Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 70.9837%; height: 19.6px;\"\u003eDirect spark ignition\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 28.7016%; height: 19.6px;\"\u003e\u003cstrong\u003eIgniter-Sensor Rods\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 70.9837%; height: 19.6px;\"\u003eDual rod configuration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 28.7016%; height: 19.6px;\"\u003e\u003cstrong\u003eIgnition Trial Time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 70.9837%; height: 19.6px;\"\u003e4 seconds\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 28.7016%; height: 19.6px;\"\u003e\u003cstrong\u003eLockout Timing\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 70.9837%; height: 19.6px;\"\u003e4 seconds\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.2px;\"\u003e\n\u003ctd style=\"width: 28.7016%; height: 39.2px;\"\u003e\u003cstrong\u003eIgnition Trials to Lockout\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 70.9837%; height: 39.2px;\"\u003e1 trial before lockout occurs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 28.7016%; height: 19.6px;\"\u003e\u003cstrong\u003eReset Method\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 70.9837%; height: 19.6px;\"\u003eManual reset from thermostat after lockout\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 28.7016%; height: 19.6px;\"\u003e\u003cstrong\u003ePre-Purge Delay\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 70.9837%; height: 19.6px;\"\u003eUp to 10 seconds maximum timing delay\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.2px;\"\u003e\n\u003ctd style=\"width: 28.7016%; height: 39.2px;\"\u003e\u003cstrong\u003eFlame Failure Response Time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 70.9837%; height: 39.2px;\"\u003e2.0 seconds @ 2.5 microamps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.2px;\"\u003e\n\u003ctd style=\"width: 28.7016%; height: 39.2px;\"\u003e\u003cstrong\u003eThermostat Anticipator Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 70.9837%; height: 39.2px;\"\u003e0.2A plus gas control current\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 28.7016%; height: 19.6px;\"\u003e\u003cstrong\u003eMaximum Valve Load\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 70.9837%; height: 19.6px;\"\u003e2A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 28.7016%; height: 19.6px;\"\u003e\u003cstrong\u003eFuel Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 70.9837%; height: 19.6px;\"\u003eNatural Gas or LPG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 28.7016%; height: 19.6px;\"\u003e\u003cstrong\u003eTypical Gas Controls\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 70.9837%; height: 19.6px;\"\u003eCompatible with Honeywell VR8205, VR8305 valves\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 28.7016%; height: 19.6px;\"\u003e\u003cstrong\u003eMounting Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 70.9837%; height: 19.6px;\"\u003eUniversal (any orientation)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 28.7016%; height: 19.6px;\"\u003e\u003cstrong\u003eProduct Depth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 70.9837%; height: 19.6px;\"\u003e1.94 in (49 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 28.7016%; height: 19.6px;\"\u003e\u003cstrong\u003eEnclosure Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 70.9837%; height: 19.6px;\"\u003eUL recognized, CSA certified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.2px;\"\u003e\n\u003ctd style=\"width: 28.7016%; height: 39.2px;\"\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 70.9837%; height: 39.2px;\"\u003eDirect spark ignition systems for furnaces and heating appliances\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 28.7016%; height: 19.6px;\"\u003e\u003cstrong\u003eApprovals\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 70.9837%; height: 19.6px;\"\u003eUL File No. MP268; CSA Certified 158158-1047805\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 28.7016%; height: 19.6px;\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 70.9837%; height: 19.6px;\"\u003e1.00 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003e\u003cbr\u003e\u003c\/h4\u003e\n\u003ch4\u003eInformation About \u003cspan data-sheets-root=\"1\"\u003eS89E1058\u003c\/span\u003e\n\u003c\/h4\u003e\n\u003cp\u003eThe S89E1058 is part of Honeywell’s S89 Series of direct spark ignition control modules, designed to provide safe, reliable ignition and flame monitoring for gas-fired heating systems. It uses a 24V control circuit to regulate gas valve and ignition timing, while a separate 120V spark generator delivers the high-voltage energy required for main burner ignition. The module conducts a single 4-second trial for ignition and enters a lockout mode if flame is not detected, ensuring enhanced system safety. The thermostat reset feature allows quick recovery from lockout conditions. Compatible with Honeywell VR8205 and VR8305 gas controls, the S89E1058 is ideal for furnaces and power burners operating on natural gas or LPG.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eTwo-Rod Ignition Design: Separate ignition and flame-sensing rods enhance reliability and flame detection accuracy.\u003c\/li\u003e\n\u003cli\u003eIntegrated Lockout Protection: Automatically locks out the system after one failed ignition attempt, preventing unsafe gas accumulation.\u003c\/li\u003e\n\u003cli\u003eFast Ignition and Response: Features a 4-second ignition trial and 2-second flame failure response for quick startup and safety assurance.\u003c\/li\u003e\n\u003cli\u003eThermostat Reset Capability: Allows lockout reset directly from the thermostat without manual intervention at the control.\u003c\/li\u003e\n\u003cli\u003eCompatible Gas Valves: Designed to operate with Honeywell VR8205 and VR8305 series gas controls rated up to 2A.\u003c\/li\u003e\n\u003cli\u003eUniversal Mounting: Compact design enables mounting in any position within the appliance for installation flexibility.\u003c\/li\u003e\n\u003cli\u003eDurable and Certified: UL and CSA approved for use in residential and commercial heating systems using natural gas or LPG.\u003c\/li\u003e\n\u003cli\u003eExternal Spark Source: Uses a 120V high-voltage spark generator for dependable ignition performance in direct spark applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe S89E1058 delivers the reliability and precision required for safe burner ignition control in furnaces, boilers, and heating appliances using direct spark ignition technology.\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":49105154507008,"sku":"S89E1058","price":877.59,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0388\/5331\/2557\/files\/Honeywell-S89E1058-Direct-Spark-Ignition-Control.png?v=1785541460","url":"https:\/\/alotechparts.com\/products\/s89e1058-honeywell-24v-direct-spark-ignition-control-module-two-rod-system","provider":"Alo Tech Solutions","version":"1.0","type":"link"}