{"product_id":"rp-2002-notifier-six-zone-agent-releasing-fire-alarm-control-panel","title":"RP-2002 | Notifier Six-Zone Agent Releasing Fire Alarm Control Panel","description":"\u003ch4\u003eDescription \u003c\/h4\u003e\n\u003cp data-start=\"144\" data-end=\"396\"\u003eThe Notifier RP-2002 is a six-zone fire alarm control panel designed for single and dual hazard agent releasing applications. It provides fire detection, signaling, and suppression control for commercial, industrial, and institutional environments.\u003c\/p\u003e\n\u003cp data-start=\"284\" data-end=\"574\" class=\"\"\u003e \u003c\/p\u003e\n\u003cp data-start=\"284\" data-end=\"574\" class=\"\"\u003e \u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications \u003c\/h4\u003e\n\u003ctable style=\"width: 99.964%; height: 411.6px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 22.8842%; height: 19.6px;\"\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 76.9827%; height: 19.6px;\"\u003eNew\/Never Used Surplus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 22.8842%; height: 19.6px;\"\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 76.9827%; height: 19.6px;\"\u003eNotifier\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 22.8842%; height: 19.6px;\"\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 76.9827%; height: 19.6px;\"\u003eFire Alarm Systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 22.8842%; height: 19.6px;\"\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 76.9827%; height: 19.6px;\"\u003eRP-2002\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 22.8842%; height: 19.6px;\"\u003e\u003cstrong\u003eSubcategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 76.9827%; height: 19.6px;\"\u003eAgent Releasing Panels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 22.8842%; height: 19.6px;\"\u003e\u003cstrong\u003eZones\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 76.9827%; height: 19.6px;\"\u003eSix initiating zones\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 22.8842%; height: 19.6px;\"\u003e\u003cstrong\u003eHazard Support\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 76.9827%; height: 19.6px;\"\u003eSingle and dual hazard releasing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.2px;\"\u003e\n\u003ctd style=\"width: 22.8842%; height: 39.2px;\"\u003e\u003cstrong\u003eCompatible Detectors\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 76.9827%; height: 39.2px;\"\u003eSystem Sensor i3 series, two-wire and four-wire detectors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.2px;\"\u003e\n\u003ctd style=\"width: 22.8842%; height: 39.2px;\"\u003e\u003cstrong\u003eInput Devices\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 76.9827%; height: 39.2px;\"\u003eSmoke detectors, pull stations, water flow, tamper switches, NO contacts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 22.8842%; height: 19.6px;\"\u003e\u003cstrong\u003eOutputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 76.9827%; height: 19.6px;\"\u003eFour programmable NACs or releasing circuits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 22.8842%; height: 19.6px;\"\u003e\u003cstrong\u003eRelays\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 76.9827%; height: 19.6px;\"\u003eThree Form-C relays (Alarm, Trouble, Supervisory)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 22.8842%; height: 19.6px;\"\u003e\u003cstrong\u003ePower Outputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 76.9827%; height: 19.6px;\"\u003e24 VDC resettable and non-resettable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 22.8842%; height: 19.6px;\"\u003e\u003cstrong\u003eDisplay\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 76.9827%; height: 19.6px;\"\u003eLED indicators for system status\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 22.8842%; height: 19.6px;\"\u003e\u003cstrong\u003eSeismic Compliance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 76.9827%; height: 19.6px;\"\u003eMeets IBC seismic requirements\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 22.8842%; height: 19.6px;\"\u003e\u003cstrong\u003eProtection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 76.9827%; height: 19.6px;\"\u003eExtensive transient protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 22.8842%; height: 19.6px;\"\u003e\u003cstrong\u003eCertifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 76.9827%; height: 19.6px;\"\u003eUL listed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 22.8842%; height: 19.6px;\"\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 76.9827%; height: 19.6px;\"\u003e8.50 × 22.50 × 20.00 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 22.8842%; height: 19.6px;\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 76.9827%; height: 19.6px;\"\u003e16 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003e\u003cbr\u003e\u003c\/h4\u003e\n\u003ch4\u003eInformation About \u003cspan data-sheets-root=\"1\"\u003eRP-2002\u003c\/span\u003e\n\u003c\/h4\u003e\n\u003cp\u003eThe RP-2002 is a UL-listed fire alarm control and releasing panel that integrates six initiating zones, programmable outputs, and dedicated supervisory relays to provide reliable fire detection and suppression system management. It is fully compatible with System Sensor i3 detectors, which offer advanced functionality including maintenance trouble alerts and low-temperature supervisory signals. Conventional devices such as smoke detectors, pull stations, water flow devices, and tamper switches are also supported, giving the panel broad flexibility. With transient surge protection, seismic compliance, and integrated 24 VDC power outputs, the RP-2002 is designed for dependable operation in safety-critical environments.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSix Initiating Zones: Supports six independent zones for fire detection and releasing control.\u003c\/li\u003e\n\u003cli\u003eDual Hazard Operation: Configurable for both single and dual hazard suppression systems.\u003c\/li\u003e\n\u003cli\u003ei3 Detector Integration: Compatible with System Sensor i3 detectors, supporting trouble and freeze supervisory signals.\u003c\/li\u003e\n\u003cli\u003eBroad Device Compatibility: Accepts two-wire\/four-wire detectors, pull stations, tamper switches, and water flow devices.\u003c\/li\u003e\n\u003cli\u003eProgrammable NACs\/Releasing Circuits: Four outputs configurable for notification or releasing functions.\u003c\/li\u003e\n\u003cli\u003eBuilt-In Relays: Includes three Form-C relays pre-set for Alarm, Trouble, and Supervisory outputs.\u003c\/li\u003e\n\u003cli\u003ePower Distribution: Provides resettable and non-resettable 24 VDC power outputs for auxiliary devices.\u003c\/li\u003e\n\u003cli\u003eSurge and Transient Protection: Ensures stable and reliable operation in demanding electrical conditions.\u003c\/li\u003e\n\u003cli\u003eSeismic-Ready: Complies with International Building Code (IBC) seismic requirements.\u003c\/li\u003e\n\u003cli\u003eUL Certification: Recognized for meeting strict safety and performance standards.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe RP-2002 delivers the reliability and precision required for agent releasing applications across commercial and institutional facilities.\u003c\/p\u003e","brand":"Notifier","offers":[{"title":"Default Title","offer_id":49105181081856,"sku":"RP-2002","price":1652.28,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0388\/5331\/2557\/files\/ScreenShot2022-01-09at6.59.32PM_540x_0336bdeb-9783-429d-86a2-084e442ef251.png?v=1785542013","url":"https:\/\/alotechparts.com\/products\/rp-2002-notifier-six-zone-agent-releasing-fire-alarm-control-panel","provider":"Alo Tech Solutions","version":"1.0","type":"link"}