{"product_id":"rm7800l1012-honeywell-7800-series-burner-control-relay-module-with-display","title":"RM7800L1012 | Honeywell 7800 Series Burner Control Relay Module With Display","description":"\u003ch4\u003eDescription \u003c\/h4\u003e\n\u003cp data-start=\"97\" data-end=\"397\"\u003eThe Honeywell RM7800L1012 is a microprocessor-based burner control relay module with an integrated keyboard display for monitoring and diagnostics. It manages automatic burner sequencing, flame supervision, and safety shutdown functions in commercial and industrial combustion systems.\u003c\/p\u003e\n\u003cp class=\"\" data-end=\"574\" data-start=\"284\"\u003e \u003c\/p\u003e\n\u003cp class=\"\" data-end=\"574\" data-start=\"284\"\u003e \u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications \u003c\/h4\u003e\n\u003ctable style=\"width: 100%;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 31.0327%;\"\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 68.6037%;\"\u003eNew\/Never Used Surplus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 31.0327%;\"\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 68.6037%;\"\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 31.0327%;\"\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 68.6037%;\"\u003eBurner Controls\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 31.0327%;\"\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 68.6037%;\"\u003eRM7800L1012\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 31.0327%;\"\u003e\u003cstrong\u003eSubcategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 68.6037%;\"\u003eBurner Control Relay Modules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 31.0327%;\"\u003e\u003cstrong\u003eSupply Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 68.6037%;\"\u003e120 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 31.0327%;\"\u003e\u003cstrong\u003eFrequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 68.6037%;\"\u003e50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 31.0327%;\"\u003e\u003cstrong\u003eFlame Establishing Period – Pilot\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 68.6037%;\"\u003e4 sec or 10 sec\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 31.0327%;\"\u003e\u003cstrong\u003eFlame Establishing Period – Main\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 68.6037%;\"\u003e10 sec or 15 sec\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 31.0327%;\"\u003e\u003cstrong\u003eEarly Spark Termination\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 68.6037%;\"\u003eYes, 5 seconds\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 31.0327%;\"\u003e\u003cstrong\u003ePre-Ignition Interlocks\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 68.6037%;\"\u003eLow and High Fire\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 31.0327%;\"\u003e\u003cstrong\u003eDiagnostics\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 68.6037%;\"\u003eSelf and system diagnostics with history files\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 31.0327%;\"\u003e\u003cstrong\u003eMemory Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 68.6037%;\"\u003eNon-volatile\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 31.0327%;\"\u003e\u003cstrong\u003eAmplifier Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 68.6037%;\"\u003eInterchangeable plug-in amplifiers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 31.0327%;\"\u003e\u003cstrong\u003eIndication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 68.6037%;\"\u003eFive LEDs and keyboard display module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 31.0327%;\"\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 68.6037%;\"\u003e-40°F to 140°F (-40°C to 60°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 31.0327%;\"\u003e\u003cstrong\u003eApplication Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 68.6037%;\"\u003eProgramming control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 31.0327%;\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 68.6037%;\"\u003e4.8 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4\u003e\u003cbr\u003e\u003c\/h4\u003e\n\u003ch4\u003e\u003cbr\u003e\u003c\/h4\u003e\n\u003ch4\u003eInformation About\u003cspan data-sheets-root=\"1\"\u003e RM7800L1012\u003c\/span\u003e\n\u003c\/h4\u003e\n\u003cp\u003eThe RM7800L1012 is a Honeywell 7800 Series burner control relay module designed to manage and monitor automatically fired gas or oil burners. It integrates a keyboard display module that provides real-time system status, fault history, and diagnostic information. The controller supports interchangeable plug-in flame amplifiers and maintains lockout and historical data using non-volatile memory after power loss. It is compatible with existing Honeywell flame detectors and supports flexible communication and annunciation options for local or remote monitoring.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eIntegrated Keyboard Display Module: Provides on-site access to system status, diagnostics, and fault history information.\u003c\/li\u003e\n\u003cli\u003eAutomatic Burner Sequencing: Controls pre-ignition, ignition, run, and shutdown sequences for safe burner operation.\u003c\/li\u003e\n\u003cli\u003eFlame Supervision Capability: Continuously monitors flame presence using compatible Honeywell flame detectors.\u003c\/li\u003e\n\u003cli\u003eSelectable Flame Establishing Periods: Supports configurable pilot and main flame establishing times for system flexibility.\u003c\/li\u003e\n\u003cli\u003eAdvanced Diagnostics And Memory: Stores lockout status and history files in non-volatile memory for troubleshooting.\u003c\/li\u003e\n\u003cli\u003eInterchangeable Plug-In Amplifiers: Allows system configuration based on application-specific flame detection needs.\u003c\/li\u003e\n\u003cli\u003eLED Status Indicators: Five onboard LEDs provide clear visual indication of operating sequence and faults.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe RM7800L1012 delivers the reliability and precision required for safe burner management, diagnostics, and flame supervision in industrial combustion control systems.\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":49105019306240,"sku":"RM7800L1012","price":2791.53,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0388\/5331\/2557\/files\/rm7800l1012_2.jpg?v=1785538150","url":"https:\/\/alotechparts.com\/products\/rm7800l1012-honeywell-7800-series-burner-control-relay-module-with-display","provider":"Alo Tech Solutions","version":"1.0","type":"link"}