{"product_id":"ra890g1229-honeywell-120v-flame-safe-guard-protectorelay","title":"RA890G1229 | Honeywell 120V Flame Safe Guard Protectorelay","description":"\u003ch4\u003eDescription \u003c\/h4\u003e\n\u003cp\u003eThe Honeywell RA890G1229 is a 120V flame safeguard Protectorelay designed for interrupted or intermittent ignition on gas and oil burners. It provides rapid 0.8-second flame failure response and 15-second safety lockout, ensuring safe operation of industrial and commercial burner systems.\u003c\/p\u003e\n\u003cp class=\"\" data-end=\"574\" data-start=\"284\"\u003e \u003c\/p\u003e\n\u003cp class=\"\" data-end=\"574\" data-start=\"284\"\u003e \u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications \u003c\/h4\u003e\n\u003ctable style=\"height: 605.016px; width: 100%;\" width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 43.25px;\"\u003e\n\u003cth class=\"text-left text-body1 text-bold py-10 pr-10 desktop:pr-[10rem] desktop:text-nowrap\" style=\"width: 31.0909%; text-align: left; height: 43.25px;\"\u003eCondition\u003c\/th\u003e\n\u003ctd class=\"text-left text-body1 py-10 desktop:w-[60%]\" style=\"width: 68.5455%; height: 43.25px;\"\u003eNew\/Never Used Surplus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 34.1719px;\"\u003e\n\u003cth class=\"text-left text-body1 text-bold py-10 pr-10 desktop:pr-[10rem] desktop:text-nowrap\" style=\"width: 31.0909%; text-align: left; height: 34.1719px;\"\u003eBrand\u003c\/th\u003e\n\u003ctd class=\"text-left text-body1 py-10 desktop:w-[60%]\" style=\"width: 68.5455%; height: 34.1719px;\"\u003e\u003cspan data-sheets-root=\"1\"\u003eHoneywell\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 30.5px;\"\u003e\n\u003cth style=\"width: 31.0909%; text-align: left; height: 30.5px;\"\u003eCategory\u003c\/th\u003e\n\u003ctd style=\"width: 68.5455%; height: 30.5px;\"\u003e\n\u003cdiv class=\"mt-1 md:mt-0 column-left basis-2\/4 divide-y divide-rad-gray-10 border-b-[0.0625rem] border-rad-gray-10 md:border-0\"\u003e\n\u003cdiv class=\"flex gap-[1.75rem] md:gap-x-0 xl:gap-x-[1.875rem]\"\u003e\n\u003cdiv class=\"text-body-4 w-full font-light py-5 pl-4 md:py-6 md:pl-6 text-rad-gray-70\"\u003e\n\u003cdiv class=\"max-w-[8rem] break-words\"\u003e\n\u003cspan\u003e\u003c\/span\u003e\u003cspan\u003eHVAC\u003c\/span\u003e\u003cbr\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 35.2344px;\"\u003e\n\u003cth style=\"width: 31.0909%; text-align: left; height: 35.2344px;\"\u003ePart Number\u003c\/th\u003e\n\u003ctd style=\"width: 68.5455%; height: 35.2344px;\"\u003e\u003cspan data-sheets-root=\"1\"\u003eRA890G1229\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 29.6719px;\"\u003e\n\u003cth style=\"width: 31.0909%; text-align: left; height: 29.6719px;\"\u003e\u003cspan\u003eSubcategory\u003c\/span\u003e\u003c\/th\u003e\n\u003ctd style=\"width: 68.5455%; height: 29.6719px;\"\u003e\u003cspan data-sheets-root=\"1\"\u003e\u003cspan\u003eBoiler Control\u003c\/span\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 28.1875px;\"\u003e\n\u003cth style=\"width: 31.0909%; text-align: left; height: 28.1875px;\"\u003e\u003cspan\u003eVoltage \/ Frequency\u003c\/span\u003e\u003c\/th\u003e\n\u003ctd style=\"width: 68.5455%; height: 28.1875px;\"\u003e120V AC, 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 25.375px;\"\u003e\n\u003cth style=\"width: 31.0909%; text-align: left; height: 25.375px;\"\u003e\u003cspan\u003eSafety Switch Timing\u003c\/span\u003e\u003c\/th\u003e\n\u003ctd style=\"width: 68.5455%; height: 25.375px;\"\u003e15 seconds\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003cth style=\"width: 31.0909%; text-align: left; height: 39.1875px;\"\u003eFlame Failure Response Time\u003c\/th\u003e\n\u003ctd style=\"width: 68.5455%; height: 39.1875px;\"\u003e0.8 seconds (nominal)\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003cth style=\"width: 31.0909%; text-align: left; height: 39.1875px;\"\u003eFlame Establishing Time\u003c\/th\u003e\n\u003ctd style=\"width: 68.5455%; height: 39.1875px;\"\u003eUp to 15 seconds\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003cth style=\"width: 31.0909%; text-align: left; height: 39.1875px;\"\u003eCompatible Flame Detectors\u003c\/th\u003e\n\u003ctd style=\"width: 68.5455%; height: 39.1875px;\"\u003eC7027, C7035, C7044 Ultraviolet Minipeeper (ordered separately)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003cth style=\"width: 31.0909%; text-align: left; height: 39.1875px;\"\u003eCompatible Controllers\u003c\/th\u003e\n\u003ctd style=\"width: 68.5455%; height: 39.1875px;\"\u003eLine or low voltage (non-UL approved low voltage)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003cth style=\"width: 31.0909%; text-align: left; height: 39.1875px;\"\u003eElectrical Load Ratings\u003c\/th\u003e\n\u003ctd style=\"width: 68.5455%; height: 39.1875px;\"\u003eBurner Motor: 5.2A @ 120V (Locked Rotor: 31.2A), Ignition: 3.0A, Pilot Valve: 25VA, Main Valve: 125VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003cth style=\"width: 31.0909%; text-align: left; height: 39.1875px;\"\u003eTest Jack\u003c\/th\u003e\n\u003ctd style=\"width: 68.5455%; height: 39.1875px;\"\u003eYes, for flame signal verification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003cth style=\"width: 31.0909%; text-align: left; height: 39.1875px;\"\u003eAmbient Operating Temp\u003c\/th\u003e\n\u003ctd style=\"width: 68.5455%; height: 39.1875px;\"\u003e-20°F to 115°F (-29°C to 46°C); -40°F model available\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003cth style=\"width: 31.0909%; text-align: left; height: 39.1875px;\"\u003eAlarm Contacts (Optional)\u003c\/th\u003e\n\u003ctd style=\"width: 68.5455%; height: 39.1875px;\"\u003e3.0A @ 24VDC or 75VA @ 120V (field-installable SPDT)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003cth style=\"width: 31.0909%; text-align: left; height: 19.5938px;\"\u003eEnclosure Dimensions\u003c\/th\u003e\n\u003ctd style=\"width: 68.5455%; height: 19.5938px;\"\u003eApprox. 5\" x 5\" (127 mm x 127 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003cth style=\"width: 31.0909%; text-align: left; height: 19.5938px;\"\u003eEnclosure Type\u003c\/th\u003e\n\u003ctd style=\"width: 68.5455%; height: 19.5938px;\"\u003eDust-resistant thermoplastic with push-to-reset button\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 25.9375px;\"\u003e\n\u003cth style=\"width: 31.0909%; text-align: left; height: 25.9375px;\"\u003eWeight\u003c\/th\u003e\n\u003ctd style=\"width: 68.5455%; height: 25.9375px;\"\u003e\u003cspan\u003e3.00 lbs\u003cbr\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003cspan style=\"font-size: 0.875rem;\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eInformation About \u003cspan data-sheets-root=\"1\"\u003eRA890G1229\u003c\/span\u003e\n\u003c\/h4\u003e\n\u003cp\u003eThe RA890G1229 is part of Honeywell’s RA890G series of Protectorelay primary controls, offering solid-state electronic protection for single or dual burner applications. It works with C7027, C7035, or C7044 Minipeeper Ultraviolet Flame Detectors and supports both line voltage and low-voltage controllers. Designed for use in environments that demand fast flame failure detection, this unit ensures burner safety through its automatic lockout functionality and a flame establishment period of up to 15 seconds.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eFast Flame Failure Response: 0.8-second response time with 15-second safety switch lockout.\u003c\/li\u003e\n\u003cli\u003eUniversal Flame Detector Support: Compatible with C7027, C7035, or C7044 UV flame detectors.\u003c\/li\u003e\n\u003cli\u003eInterrupt or Intermittent Ignition: Works with both oil and gas burners in safety-critical applications.\u003c\/li\u003e\n\u003cli\u003eSafe-Start Logic: Prevents burner start if flame or flame simulation fault is present.\u003c\/li\u003e\n\u003cli\u003ePush-to-Reset Safety Lockout: Dust-resistant enclosure with manual reset for fault clearing.\u003c\/li\u003e\n\u003cli\u003eAutomatic Shutoff on Flame Loss: Securely de-energizes fuel valves if flame fails post-ignition.\u003c\/li\u003e\n\u003cli\u003eLED\/Signal Testing: Built-in test jack allows flame signal measurements during service.\u003c\/li\u003e\n\u003cli\u003eExtreme Temperature Ready: Operates from -20°F standard, optional model available for -40°F.\u003c\/li\u003e\n\u003cli\u003eEasy Mounting: Captive screws and thermoplastic base simplify installation and removal.\u003c\/li\u003e\n\u003cli\u003eSolid-State Reliability: Withstands vibration and eliminates warm-up delay using advanced circuitry.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe RA890G1229 offers rapid flame detection, automatic safety lockout, and compatibility with UV flame sensors—making it ideal for demanding burner applications requiring fast response and high reliability.\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":49105313267968,"sku":"RA890G1229","price":2468.13,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0388\/5331\/2557\/files\/RA890G1229-U.webp?v=1785544743","url":"https:\/\/alotechparts.com\/products\/ra890g1229-honeywell-120v-flame-safe-guard-protectorelay","provider":"Alo Tech Solutions","version":"1.0","type":"link"}