{"product_id":"r8001n7001-honeywell-annunciator-module","title":"R8001N7001 | Honeywell Annunciator Module","description":"\u003ch4\u003eDescription \u003c\/h4\u003e\n\u003cp\u003eThe R8001N7001 is a Honeywell SLATE annunciator module used for monitoring multiple burner interlock conditions. It enhances system diagnostics by reporting fault and status messages to the burner control system via its integrated inputs and relay output.\u003c\/p\u003e\n\u003cp data-start=\"284\" data-end=\"574\" class=\"\"\u003e \u003c\/p\u003e\n\u003cp data-start=\"284\" data-end=\"574\" class=\"\"\u003e \u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications \u003c\/h4\u003e\n\u003ctable width=\"100%\" style=\"height: 378.219px; width: 100%;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003cth style=\"width: 31.2708%; text-align: left; height: 19.5938px;\" class=\"text-left text-body1 text-bold py-10 pr-10 desktop:pr-[10rem] desktop:text-nowrap\"\u003eCondition\u003c\/th\u003e\n\u003ctd style=\"width: 68.3656%; height: 19.5938px;\" class=\"text-left text-body1 py-10 desktop:w-[60%]\"\u003eNew\/Never Used Surplus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 23.2344px;\"\u003e\n\u003cth style=\"width: 31.2708%; text-align: left; height: 23.2344px;\" class=\"text-left text-body1 text-bold py-10 pr-10 desktop:pr-[10rem] desktop:text-nowrap\"\u003eBrand\u003c\/th\u003e\n\u003ctd style=\"width: 68.3656%; height: 23.2344px;\" class=\"text-left text-body1 py-10 desktop:w-[60%]\"\u003e\u003cspan data-sheets-root=\"1\"\u003eHoneywell\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 25.625px;\"\u003e\n\u003cth style=\"width: 31.2708%; text-align: left; height: 25.625px;\"\u003eCategory\u003c\/th\u003e\n\u003ctd style=\"width: 68.3656%; height: 25.625px;\"\u003e\n\u003cdiv class=\"mt-1 md:mt-0 column-left basis-2\/4 divide-y divide-rad-gray-10 border-b-[0.0625rem] border-rad-gray-10 md:border-0\"\u003e\n\u003cdiv class=\"flex gap-[1.75rem] md:gap-x-0 xl:gap-x-[1.875rem]\"\u003e\n\u003cdiv class=\"text-body-4 w-full font-light py-5 pl-4 md:py-6 md:pl-6 text-rad-gray-70\"\u003e\n\u003cdiv class=\"max-w-[8rem] break-words\"\u003e\n\u003cspan\u003e\u003c\/span\u003e\u003cspan\u003eHVAC\u003c\/span\u003e\u003cbr\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 25.125px;\"\u003e\n\u003cth style=\"width: 31.2708%; text-align: left; height: 25.125px;\"\u003e\u003cspan\u003ePart Number\u003c\/span\u003e\u003c\/th\u003e\n\u003ctd style=\"width: 68.3656%; height: 25.125px;\"\u003e\u003cspan data-sheets-root=\"1\"\u003eR8001N7001\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.625px;\"\u003e\n\u003cth style=\"width: 31.2708%; text-align: left; height: 19.625px;\"\u003e\u003cspan\u003eSubcategory\u003c\/span\u003e\u003c\/th\u003e\n\u003ctd style=\"width: 68.3656%; height: 19.625px;\"\u003e\u003cspan data-sheets-root=\"1\"\u003e\u003cspan\u003eBurner Control\u003c\/span\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 23.75px;\"\u003e\n\u003cth style=\"width: 31.2708%; text-align: left; height: 23.75px;\"\u003e\u003cspan\u003eVoltage Input Range\u003c\/span\u003e\u003c\/th\u003e\n\u003ctd style=\"width: 68.3656%; height: 23.75px;\"\u003e24 VDC (±15%), 24 VAC (±15%), or 85–264 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 32.3125px;\"\u003e\n\u003cth style=\"width: 31.2708%; text-align: left; height: 32.3125px;\"\u003e\u003cspan\u003eFrequency\u003c\/span\u003e\u003c\/th\u003e\n\u003ctd style=\"width: 68.3656%; height: 32.3125px;\"\u003e50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 29.6094px;\"\u003e\n\u003cth style=\"width: 31.2708%; text-align: left; height: 29.6094px;\"\u003eRelay Outputs\u003c\/th\u003e\n\u003ctd style=\"width: 68.3656%; height: 29.6094px;\"\u003e1 Output\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003cth style=\"width: 31.2708%; text-align: left; height: 19.5938px;\"\u003eInput Points\u003c\/th\u003e\n\u003ctd style=\"width: 68.3656%; height: 19.5938px;\"\u003e14 Opto-Isolated Inputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003cth style=\"width: 31.2708%; text-align: left; height: 39.1875px;\"\u003eMaximum Connected Load\u003c\/th\u003e\n\u003ctd style=\"width: 68.3656%; height: 39.1875px;\"\u003e2000 VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003cth style=\"width: 31.2708%; text-align: left; height: 19.5938px;\"\u003eFusing Requirement\u003c\/th\u003e\n\u003ctd style=\"width: 68.3656%; height: 19.5938px;\"\u003e15A Fast Blow Fuse (Type SC or equivalent)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003cth style=\"width: 31.2708%; text-align: left; height: 19.5938px;\"\u003eMounting Method\u003c\/th\u003e\n\u003ctd style=\"width: 68.3656%; height: 19.5938px;\"\u003eDIN Rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22.5938px;\"\u003e\n\u003cth style=\"width: 31.2708%; text-align: left; height: 22.5938px;\"\u003eTemperature Range\u003c\/th\u003e\n\u003ctd style=\"width: 68.3656%; height: 22.5938px;\"\u003e-20°F to 150°F (-29°C to 66°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003cth style=\"width: 31.2708%; text-align: left; height: 19.5938px;\"\u003eSystem Use\u003c\/th\u003e\n\u003ctd style=\"width: 68.3656%; height: 19.5938px;\"\u003eWorks with R8001B2001, R8001S9001\/U, R8001A1001\/U\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003cth style=\"width: 31.2708%; text-align: left; height: 19.5938px;\"\u003eCertifications\u003c\/th\u003e\n\u003ctd style=\"width: 68.3656%; height: 19.5938px;\"\u003eFCC Part 15, Class A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003cth style=\"width: 31.2708%; text-align: left; height: 19.5938px;\"\u003eWeight\u003c\/th\u003e\n\u003ctd style=\"width: 68.3656%; height: 19.5938px;\"\u003e\u003cspan\u003e2 lb 1 oz (0.94 Kg)\u003cbr\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003cspan style=\"font-size: 0.875rem;\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eInformation About \u003cspan data-sheets-root=\"1\"\u003eR8001N7001\u003c\/span\u003e\n\u003c\/h4\u003e\n\u003cp\u003eThe R8001N7001 is part of the Honeywell SLATE system, specifically designed to work with the R8001B2001 Burner Control Module and R8001A1001\/U SLATE Base Module. It features 14 opto-isolated inputs that detect the status of various burner safety interlocks, helping identify faults quickly and supporting efficient troubleshooting. A single relay output provides a means of communicating aggregate status or alerts to other components in the control system.\u003c\/p\u003e\n\u003cp\u003eThis annunciator module automatically adapts to input voltages ranging from 24 VDC to 240 VAC, enabling wide installation flexibility in both low- and high-voltage environments. The R8001N7001 supports dual-fuel burner applications, making it ideal for industrial environments where fuel redundancy and safety are priorities. It is DIN rail mountable and designed for integration within electrical enclosures, meeting FCC Part 15, Class A emission standards.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eMulti-Voltage Support: Operates from 24 VDC or 24–240 VAC for maximum installation versatility.\u003c\/li\u003e\n\u003cli\u003eHigh Input Capacity: Includes 14 opto-isolated inputs for monitoring interlocks and control logic strings.\u003c\/li\u003e\n\u003cli\u003eRelay Output Function: Provides a relay signal output for alarm or system indication.\u003c\/li\u003e\n\u003cli\u003eDiagnostics Support: Indicates fault locations by monitoring a daisy-chained input configuration.\u003c\/li\u003e\n\u003cli\u003eDual-Fuel Capable: Compatible with burners that support both primary and secondary fuels.\u003c\/li\u003e\n\u003cli\u003eDIN Rail Mounting: Designed for quick installation inside control panels or standard enclosures.\u003c\/li\u003e\n\u003cli\u003eEnvironmental Durability: Operational across a wide temperature range from -20°F to 150°F (-29°C to 66°C).\u003c\/li\u003e\n\u003cli\u003eSystem Integration: Works with SLATE Subbase R8001S9001\/U and integrates seamlessly into Honeywell’s modular combustion management system.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe R8001N7001 provides a reliable annunciation solution that improves safety, diagnostics, and control system integration in demanding burner environments.\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":49105312710912,"sku":"R8001N7001","price":1468.53,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0388\/5331\/2557\/files\/r8001n7001.png?v=1785544725","url":"https:\/\/alotechparts.com\/products\/r8001n7001-honeywell-annunciator-module","provider":"Alo Tech Solutions","version":"1.0","type":"link"}