{"product_id":"qgp22200tm-square-d-200a-2-pole-240vac-thermal-magnetic-molded-case-circuit-breaker","title":"QGP22200TM | Square D 200A 2-Pole 240VAC Thermal Magnetic Molded Case Circuit Breaker","description":"\u003ch4\u003eDescription \u003c\/h4\u003e\n\u003cp\u003eThe Square D QGP22200TM is a 2-pole thermal magnetic molded case circuit breaker rated for 200 Amps and 240VAC operation. Designed for high-interrupting performance, it offers a breaking capacity of 65kA, ensuring dependable protection against overloads and short circuits. This breaker is commonly used in Meter-Pak systems, switchboards, and distribution panels for reliable electrical system protection and load management.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications \u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNew\/Never Used Surplus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSquare D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCircuit Protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eQGP22200TM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSubcategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMolded Case Circuit Breaker\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePowerPact QGP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmperage Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e200A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e240VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePoles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePhase\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSingle Phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePlug-On \/ Bolt-On\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInterrupting Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e65kA at 240VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtection Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eThermal Magnetic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Unit Function\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLong-Time and Instantaneous (LI)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaking Capacity Code\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Insulation Voltage (Ui)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e240V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Impulse Withstand Voltage (Uimp)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eContinuous Current Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e80%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eElectrical Connection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTerminal Nut (Line) \/ Lugs (Load)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTorque Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e28 N·m (247.8 lbf·in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStandards Compliance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUL, CSA, NEMA, NOM-003-SCFI-2000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e40°C to 70°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6.47 in (164.34 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWidth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3 in (76.2 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDepth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3.93 in (99.82 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3.28 lb (1.49 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eInformation About \u003cmeta charset=\"utf-8\"\u003e \u003cmeta charset=\"utf-8\"\u003e\n\u003cspan data-sheets-root=\"1\"\u003eQGP22200TM\u003c\/span\u003e\n\u003c\/h4\u003e\n\u003cp data-start=\"590\" data-end=\"1074\" class=\"\"\u003eThe QGP22200TM is part of the Square D PowerPact QGP series, engineered for high-performance protection in commercial and industrial electrical systems. Built with a durable molded case housing, it integrates LI (Long-Time and Instantaneous) trip functions and thermal-magnetic protection technology. This model is designed with a plug-on bolt-on mounting configuration for quick installation in Meter-Pak metering equipment and distribution enclosures. With compliance to UL, CSA, and IEC standards, the breaker provides safe, consistent operation under demanding load conditions.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong data-start=\"1085\" data-end=\"1102\"\u003eKey Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eHigh Interrupting Capacity: 65kA at 240VAC ensures robust fault protection in high-demand systems.\u003c\/li\u003e\n\u003cli\u003eThermal-Magnetic Trip Unit: Combines long-time and instantaneous trip functions for precise overload and short-circuit response.\u003c\/li\u003e\n\u003cli\u003eCompact 2-Pole Design: Efficiently supports 200A current rating in single-phase installations.\u003c\/li\u003e\n\u003cli\u003eDurable Construction: Molded case design ensures long-term mechanical and electrical reliability.\u003c\/li\u003e\n\u003cli\u003eEasy Mounting: Plug-on bolt-on connection simplifies installation and maintenance.\u003c\/li\u003e\n\u003cli\u003eVersatile Application: Suitable for Meter-Pak systems, switchboards, and commercial panelboards.\u003c\/li\u003e\n\u003cli\u003eCertified Safety Compliance: Meets UL, CSA, and NOM standards for international acceptance.\u003c\/li\u003e\n\u003cli\u003eOperating Temperature Range: Reliable performance from 40°C to 70°C.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe QGP22200TM delivers the reliability and precision required for safe and efficient circuit protection in commercial and industrial electrical networks.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":49105082876160,"sku":"QGP22200TM","price":2090.34,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0388\/5331\/2557\/files\/square-d-qgp22200tm-2-pole-200-amp-240v-circuit-breaker-iso-600.jpg?v=1785539726","url":"https:\/\/alotechparts.com\/products\/qgp22200tm-square-d-200a-2-pole-240vac-thermal-magnetic-molded-case-circuit-breaker","provider":"Alo Tech Solutions","version":"1.0","type":"link"}