{"product_id":"planet-igs-6325-16t4x-ip30-industrial-l3-16-port-101001000t-4-port-10g-sfp-ma","title":"Planet IGS-6325-16T4X IP30 Industrial L3 16-Port 10\/100\/1000T + 4-Port 10G SFP+ Ma","description":"\u003cp\u003e\u003cstrong\u003e10Gbps Fiber Ports and Multiple Dual Speed Ports Deliver High-speed Networking\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003ePLANET IGS-6325-16T4X is a powerhouse in industrial networking designed to optimize performance. This Layer 3 managed switch boasts a high-density combination of copper and fiber optic interfaces, setting the stage for superior connectivity. With\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e16 10\/100\/1000BASE-T RJ45 ports\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e4 10GBASE-SR\/LR SFP+ ports\u003c\/strong\u003e, it's equipped to handle diverse demands. Housed in a rugged IP30 metal case with DIN-rail compatibility, it thrives in extreme environments spanning from\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e-40\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eto\u003cstrong\u003e\u003cspan\u003e \u003c\/span\u003e75 degrees Celsius\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eFeaturing a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e10Gbps uplink\u003c\/strong\u003e, the IGS-6325-16T4X seamlessly manages substantial data loads within a secure topology. Whether connecting to an industrial backbone or high-capacity servers, its prowess is unmatched. Operating flawlessly across an extensive temperature range, it guarantees a non-blocking switch fabric, delivering astonishing wire-speed throughput of up to\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e112Gbps\u003c\/strong\u003e. This transformative capability simplifies the process of industrial LAN upgrades, efficiently catering to escalating bandwidth requirements.\u003c\/p\u003e\n\u003cp\u003eFrom demanding conditions to intensive data streams, the IGS-6325-16T4X emerges as the ultimate choice for enhancing industrial network performance.\u003c\/p\u003e\n\u003cp\u003e\u003cimg class=\"img-fluid\" height=\"400\" width=\"1000\" src=\"https:\/\/planet.com.tw\/storage\/products\/49688\/edm_IGS-6325-16T4X.jpg\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cimg class=\"img-fluid\" height=\"320\" width=\"700\" alt=\"\" src=\"https:\/\/planet.com.tw\/storage\/products\/49688\/IGS-6325-16T4X-6.png\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFlexible and Extendable 10Gb Ethernet Solution\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e10G Ethernet is a big leap in the evolution of Ethernet. Each of the 10G SFP+ slots in the IGS-6325-16T4X supports triple speed and 10GBASE-SR\/LR, 2500BASE-X or 1000BASE-SX\/LX, providing broad bandwidth and powerful processing capacity. With its 2-port, 10G Ethernet link capability, the administrator now can flexibly choose the suitable SFP\/SFP+ transceiver according to the transmission distance or the transmission speed required to extend the network efficiently. \u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIntelligent SFP Diagnosis Mechanism\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe IGS-6325-16T4X supports SFP-DDM (digital diagnostic monitor) function that greatly helps network administrator to easily monitor real-time parameters of the SFP transceivers, such as optical output power, optical input power, temperature, laser bias current, and transceiver supply voltage.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cimg class=\"img-fluid\" height=\"350\" width=\"700\" alt=\"\" src=\"https:\/\/planet.com.tw\/storage\/products\/49688\/Common_Intelligent-SFP_SFP+-Diagnosis-Mechanism.png\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRedundant Ring, Fast Recovery for Critical Network Applications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe IGS-6325-16T4X supports redundant ring technology and features strong, rapid self-recovery capability to prevent interruptions and external intrusions. It incorporates advanced\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eITU-T G.8032 ERPS\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e(Ethernet Ring Protection Switching)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003etechnology,\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSpanning Tree Protocol (802.1s MSTP)\u003c\/strong\u003e, and\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eredundant power\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003einput system into customer’s industrial automation network to enhance system reliability and uptime in harsh factory environments. In a simple Ring network, the recovery time of data link can be as fast as 10ms. \u003c\/p\u003e\n\u003cp\u003e\u003cimg class=\"img-fluid\" height=\"440\" width=\"700\" alt=\"\" src=\"https:\/\/planet.com.tw\/storage\/products\/49688\/Common_Industrial-switch-ERPS_-None-PoE.png\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eEnvironmentally Hardened Design\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWith IP30 aluminum case, the Industrial Managed Switch provides a high level of immunity against electromagnetic interference and heavy electrical surges which are usually found on plant floors or in curb-side traffic control cabinets. It also possesses an integrated power supply source with a wide range of voltages for worldwide high availability applications requiring dual or backup power inputs. Being able to operate under the temperature range from\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e-40 to 75 degrees\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eC, the Industrial Managed Switch can be placed in almost any difficult environment.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNetwork with Cybersecurity Helps Minimize Security Risks\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe IGS-6325-16T4X comes with enhanced cybersecurity to fend off cyberthreats and cyberattacks. It supports SSHv2 and TLS v1.2 protocols to provide strong protection against advanced threats. Served as a key point to transmit data over multiple long distance fiber optical connections to customer's critical equipment in a business network, the cybersecurity feature of the IGS-6325-16T4X protects the switch management and enhances the security of the mission-critical network without any extra deployment cost and effort.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cimg class=\"img-fluid\" height=\"137\" width=\"700\" alt=\"\" src=\"https:\/\/planet.com.tw\/storage\/products\/49688\/Common_Secure-Management.png\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eModbus TCP Provides Flexible Network Connectivity for Factory Automation\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWith the supported\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eModbus TCP\/IP\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eprotocol, the IGS-6325-16T4X can easily integrate with\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSCADA\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003esystems,\u003cstrong\u003e\u003cspan\u003e \u003c\/span\u003eHMI\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003esystems and other data acquisition systems in factory floors. It enables administrators to remotely monitor the industrial Ethernet switch’s\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eoperating information\u003c\/strong\u003e,\u003cstrong\u003e\u003cspan\u003e \u003c\/span\u003eport information\u003c\/strong\u003e, communication status, and DI and DO status, thus easily achieving enhanced monitoring and maintenance of the entire factory.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e1588 Time Protocol for Industrial Computing Networks\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe IGS-6325-16T4X is ideal for telecom and carrier Ethernet applications, supporting MEF service delivery and timing over packet solutions for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIEEE 1588\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand synchronous Ethernet.\u003c\/p\u003e\n\u003cp\u003e\u003cimg class=\"img-fluid\" height=\"451\" width=\"700\" alt=\"\" src=\"https:\/\/planet.com.tw\/storage\/products\/49688\/Common_Time-Synchronization-in-Network_2.png\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRedundant Power to Ensure Continuous Operation\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe IGS-6325-16T4X possesses\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003edual DC 9~48V and AC 24V\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003epower supply utilized as redundant power supply to ensure its continuous operation. Its redundant power system is specifically designed to handle the demands of high-tech facilities requiring the highest power integrity. \u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eEffective Alarm Alert for Better Protection\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe IGS-6325-16T4X supports a Fault Alarm feature which can alert the users when there is something wrong with the switches. With this ideal feature, the users would not have to waste time to find where the problem is. It will help to save time and human resource.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cimg class=\"img-fluid\" height=\"272\" width=\"700\" alt=\"\" src=\"https:\/\/planet.com.tw\/storage\/products\/49688\/IGS-6325-16T4X-1.png\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDigital Input and Digital Output for External Alarm\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe IGS-6325-16T4X supports Digital Input and Digital Output on its front panel. This external alarm enables users to use Digital Input to detect and log external device status (such as door intrusion detector), and send event alarm to the administrators. The Digital Output could be used to alarm the administrators if the IGS-6325-16T4X port shows link down, link up or power failure.\u003c\/p\u003e\n\u003cp\u003e\u003cimg class=\"img-fluid\" height=\"574\" width=\"700\" alt=\"\" src=\"https:\/\/planet.com.tw\/storage\/products\/49688\/IGS-6325-16T4X-2.png\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSolution for IPv6 Networking\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eBy supporting IPv6\/IPv4 dual stack and plenty of management functions with easy and friendly-user interfaces, the Industrial Managed Switch is the best choice for IP surveillance, VoIP and wireless service providers to deploy the IPv6 network. It also helps the SMBs to step in the IPv6 era with the lowest investment but not necessary to replace the network facilities while the ISPs construct the IPv6 FTTx edge network.\u003c\/p\u003e\n\u003cp\u003e\u003cimg class=\"img-fluid\" height=\"388\" width=\"701\" alt=\"\" src=\"https:\/\/planet.com.tw\/storage\/products\/49688\/Common_IPv6_IPv4-Dual-Stack-Management.png\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIPv4 and IPv6 VLAN Routing for Secure and Flexible Management\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eTo help customers stay on top of their businesses, the Industrial Managed Switch not only provides ultra high transmission performance and excellent Layer 2 technologies, but also offers IPv4\/IPv6 VLAN routing feature which allows to cross over different VLANs and different IP addresses for the purpose of having a highly-secure, flexible management and simpler networking application.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIPv6\/IPv4 Dual Stack\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eSupporting both IPv6 and IPv4 protocols, the IGS-6325-16T4X helps data centers, campuses, telecoms, and more to experience the IPv6 era with the lowest investment as its network facilities need not be replaced or overhauled if the IPv6 FTTx edge network is set up. \u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eLayer 3 Routing Support\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe IGS-6325-16T4X enables the administrator to conveniently boost network efficiency by configuring Layer 3 IPv4\/IPv6 VLAN static routing manually, and the IPv4\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eOSPFv2\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(Open Shortest Path First) settings automatically. The OSPF is an interior dynamic routing protocol for autonomous system based on link state. The protocol creates a database for link state by exchanging link states among Layer 3 switches, and then uses the Shortest Path First algorithm to generate a route table based on that database.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRobust Layer 2 Features\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe IGS-6325-16T4X can be programmed for advanced Layer 2 switch management functions such as dynamic port link aggregation, 802.1Q tagged VLAN, Q-in-Q VLAN, private VLAN, Multiple Spanning Tree Protocol (MSTP), Layer 2 to Layer 4 QoS, bandwidth control, IGMP snooping and MLD snooping. Via the aggregation of supporting ports, the IGS-6325-16T4X allows the operation of a high-speed trunk group that comes with multiple ports and supports fail-over as well.\u003c\/p\u003e\n\u003cp\u003e\u003cimg class=\"img-fluid\" height=\"217\" width=\"700\" alt=\"\" src=\"https:\/\/planet.com.tw\/storage\/products\/49688\/Common_Robust-Layer-2-Features.png\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eUser-friendly Management Interfaces\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eFor efficient management, the IGS-6325-16T4X is equipped with console, Web and SNMP management interfaces.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eWith the built-in\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eWeb-based\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003emanagement interface, the IGS-6325-16T4X offers an easy-to-use, platform-independent management and configuration facility. \u003c\/li\u003e\n\u003cli\u003eFor\u003cstrong\u003e\u003cspan\u003e \u003c\/span\u003etext-based\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003emanagement, it can be accessed via Telnet and the console port. \u003c\/li\u003e\n\u003cli\u003eFor standard-based monitor and management software, it offers\u003cstrong\u003e\u003cspan\u003e \u003c\/span\u003eSNMPv3\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003econnection which encrypts the packet content at each session for secure remote management.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePowerful Network Security\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe IGS-6325-16T4X offers comprehensive Layer 2 to Layer 4\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAccess Control List (ACL)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor enforcing security to the edge. It can be used to restrict network access by denying packets based on source and destination IP address, TCP\/UDP ports or defined typical network applications. Its protection mechanism also comprises\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e802.1X Port-based\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cstrong\u003e\u003cspan\u003e \u003c\/span\u003eMAC-based\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003euser and device authentication. With the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eprivate VLAN\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efunction, communication between edge ports can be prevented to ensure user privacy. \u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAdvanced IP Network Protection\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe IGS-6325-16T4X also provides\u003cstrong\u003e\u003cspan\u003e \u003c\/span\u003eDHCP Snooping\u003c\/strong\u003e,\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIP Source Guard\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eDynamic ARP Inspection\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efunctions to prevent IP snooping from attack and discard ARP packets with invalid MAC address. The network administrators can now construct highly-secure corporate networks with considerably less time and effort than before.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eExcellent Traffic Control\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe IGS-6325-16T4X is loaded with powerful traffic management and QoS features to enhance connection services by telecoms and ISPs. The QoS features include wire-speed Layer 4 traffic classifiers and bandwidth limit that are particularly useful for multi-tenant units, multi-business units, Telco and network service providers’ applications. It also empowers the industrial environment to take full advantage of the limited network resources and guarantees the best performance in VoIP and video conferencing transmission.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eModbus TCP Provides Flexible Network Connectivity for Factory Automation\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWith the supported Modbus TCP\/IP protocol, the Industrial Managed Switch can easily integrate with\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSCADA systems\u003c\/strong\u003e,\u003cstrong\u003e\u003cspan\u003e \u003c\/span\u003eHMI systems\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand other data acquisition systems in factory floors. It enables administrators to remotely monitor the industrial Ethernet switch’s operating information, port information and communication status, thus easily achieving enhanced monitoring and maintenance of the entire factory.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRemote Management Solution\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003ePLANET's\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eUniversal Network Management System (UNI-NMS)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCloudViewerPro app\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003esupport IT staff by remotely managing all network devices and monitoring PDs' operational statuses. Thus, they're designed for both the enterprises and industries where deployments of PDs can be as remote as possible, without having to go to the actual location once a bug or faulty condition is found. With the UNI-NMS or CloudViewerPro app, all kinds of businesses can now be speedily and efficiently managed from one platform.\u003c\/p\u003e\n\u003cp\u003e\u003cimg class=\"img-fluid\" height=\"376\" width=\"700\" alt=\"\" src=\"https:\/\/planet.com.tw\/storage\/products\/49688\/IGS-6325-16T4X-4.png\"\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePhysical Port\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e16 10\/100\/1000BASE-T Gigabit Ethernet RJ45 ports \u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e4 10GBASE-SR\/LR SFP+\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eslots, compatible with 1G\/2.5GBASE-X SFP\u003c\/li\u003e\n\u003cli\u003eOne RJ45-to-RS232 console interface for basic management and setup\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIndustrial Protocol\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eModbus TCP for real-time monitoring in the SCADA system\u003c\/li\u003e\n\u003cli\u003eIEEE 1588v2 PTP (Precision Time Protocol) transparent clock mode\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIndustrial Hardened Design \u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eDual power input, redundant power with reverse polarity protection\n\u003cul\u003e\n\u003cli\u003eDC 9 to 48V input or AC 24V input\u003c\/li\u003e\n\u003cli\u003eActive-active redundant power failure protection\u003c\/li\u003e\n\u003cli\u003eBackup of catastrophic power failure on one supply\u003c\/li\u003e\n\u003cli\u003eFault tolerance and resilience\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eDIN-rail and wall-mountable designs\u003c\/li\u003e\n\u003cli\u003eIP30 aluminum case \u003c\/li\u003e\n\u003cli\u003eSupports 6KV DC Ethernet ESD protection\u003c\/li\u003e\n\u003cli\u003e-40 to 75 degrees C operating temperature\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDigital Input and Digital Output \u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e2 Digital Input (DI)\u003c\/li\u003e\n\u003cli\u003e2 Digital Output (DO)\u003c\/li\u003e\n\u003cli\u003eIntegrates sensors into auto alarm system\u003c\/li\u003e\n\u003cli\u003eTransfers alarm to IP network via email and SNMP trap\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eLayer 3 IP Routing Features\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eIP dynamic routing protocol supports RIP, OSPFv2 and OSPFv3\u003c\/li\u003e\n\u003cli\u003eSupports maximum 128 static routes and route summarization\u003c\/li\u003e\n\u003cli\u003eIPv4 dynamic routing protocol supports OSPFv2\u003c\/li\u003e\n\u003cli\u003eIPv4\/IPv6 hardware static routing\u003c\/li\u003e\n\u003cli\u003eRouting interface provides per VLAN routing mode\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eLayer 2 Features\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ePrevents packet loss with back pressure (half-duplex) and IEEE 802.3x pause frame flow control (full-duplex)\u003c\/li\u003e\n\u003cli\u003eHigh performance of Store-and-Forward architecture, and runt\/CRC filtering eliminates erroneous packets to optimize the network bandwidth\u003c\/li\u003e\n\u003cli\u003eStorm control support\n\u003cul\u003e\n\u003cli\u003eBroadcast\/Multicast\/Unknown unicast\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eSupports\u003cstrong\u003e\u003cspan\u003e \u003c\/span\u003eVLAN\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eIEEE 802.1Q tagged VLAN\u003c\/li\u003e\n\u003cli\u003eUp to 4K VLANs groups, out of 4095 VLAN IDs\u003c\/li\u003e\n\u003cli\u003eSupports provider bridging (VLAN Q-in-Q IEEE 802.1ad) \u003c\/li\u003e\n\u003cli\u003ePrivate VLAN Edge (PVE)\u003c\/li\u003e\n\u003cli\u003eProtocol-based VLAN\u003c\/li\u003e\n\u003cli\u003eMAC-based VLAN\u003c\/li\u003e\n\u003cli\u003eVoice VLAN\u003c\/li\u003e\n\u003cli\u003eGVRP (GARP VLAN Registration Protocol)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eSupports\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSpanning Tree Protocol\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eIEEE 802.1D Spanning Tree Protocol (STP)\u003c\/li\u003e\n\u003cli\u003eIEEE 802.1w Rapid Spanning Tree Protocol (RSTP)\u003c\/li\u003e\n\u003cli\u003eIEEE 802.1s Multiple Spanning Tree Protocol (MSTP), spanning tree by VLAN\u003c\/li\u003e\n\u003cli\u003eBPDU Guard\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eSupports\u003cstrong\u003e\u003cspan\u003e \u003c\/span\u003eLink Aggregation\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003e802.3ad Link Aggregation Control Protocol (LACP)\u003c\/li\u003e\n\u003cli\u003eCisco ether-channel (static trunk)\u003c\/li\u003e\n\u003cli\u003eMaximum 10 trunk groups, with 16 ports for each trunk \u003c\/li\u003e\n\u003cli\u003eUp to 80Gbps bandwidth (full duplex mode)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eProvides port mirror (many-to-1)\u003c\/li\u003e\n\u003cli\u003ePort mirroring to monitor the incoming or outgoing traffic on a particular port \u003c\/li\u003e\n\u003cli\u003eLoop protection to avoid broadcast loops\u003c\/li\u003e\n\u003cli\u003eLink Layer Discovery Protocol (LLDP)\u003c\/li\u003e\n\u003cli\u003eCompatible with Cisco uni-directional link detection(UDLD) that monitors a link between two switches and blocks the ports on both ends of the link if the link fails at any point between the two devices\u003c\/li\u003e\n\u003cli\u003eSupports G.8032 ERPS (Ethernet Ring Protection Switching)\u003c\/li\u003e\n\u003cli\u003eIEEE 1588 and Synchronous Ethernet network timing\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQuality of Service\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eIngress shaper and egress rate limit per port bandwidth control\u003c\/li\u003e\n\u003cli\u003e8 priority queues on all switch ports\u003c\/li\u003e\n\u003cli\u003eTraffic classification\n\u003cul\u003e\n\u003cli\u003eIEEE 802.1p CoS\u003c\/li\u003e\n\u003cli\u003eToS\/DSCP\/IP Precedence of IPv4\/IPv6 packets\u003c\/li\u003e\n\u003cli\u003eIP TCP\/UDP port number\u003c\/li\u003e\n\u003cli\u003eTypical network application\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eStrict priority and Weighted Round Robin (WRR) CoS policies\u003c\/li\u003e\n\u003cli\u003eTraffic-policing  on the switch port\u003c\/li\u003e\n\u003cli\u003eDSCP remarking \u003c\/li\u003e\n\u003cli\u003eVoice VLAN\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMulticast\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSupports IPv4 IGMP snooping v1, v2 and v3\u003c\/li\u003e\n\u003cli\u003eSupports IPv6 MLD snooping v1 and v2\u003c\/li\u003e\n\u003cli\u003eQuerier mode support\u003c\/li\u003e\n\u003cli\u003eIPv4 IGMP snooping port filtering\u003c\/li\u003e\n\u003cli\u003eIPv6 MLD snooping port filtering\u003c\/li\u003e\n\u003cli\u003eMVR (Multicast VLAN Registration)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSecurity\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eAuthentication\n\u003cul\u003e\n\u003cli\u003eIEEE 802.1x port-based\/MAC-based network access authentication\u003c\/li\u003e\n\u003cli\u003eIEEE 802.1x authentication with guest VLAN\u003c\/li\u003e\n\u003cli\u003eBuilt-in RADIUS client to cooperate with the RADIUS servers\u003c\/li\u003e\n\u003cli\u003eRADIUS\/TACACS+ users access authentication\u003c\/li\u003e\n\u003cli\u003eGuest VLAN assigns clients to a restricted VLAN with limited services\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eAccess Control List\n\u003cul\u003e\n\u003cli\u003eIP-based Access Control List (ACL)\u003c\/li\u003e\n\u003cli\u003eMAC-based Access Control List (ACL)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eSource MAC\/IP address binding\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDHCP Snooping\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eto filter distrusted DHCP messages\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDynamic ARP Inspection\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ediscards ARP packets with invalid MAC address to IP address binding\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIP Source Guard\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eprevents IP spoofing attacks\u003c\/li\u003e\n\u003cli\u003eIP address access management to prevent unauthorized intruder\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eManagement\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eIPv4 and IPv6 dual stack management\u003c\/li\u003e\n\u003cli\u003eSwitch Management Interfaces\n\u003cul\u003e\n\u003cli\u003eConsole and Telnet Command Line Interface \u003c\/li\u003e\n\u003cli\u003eHTTP web switch management\u003c\/li\u003e\n\u003cli\u003eSNMP v1 and v2c switch management\u003c\/li\u003e\n\u003cli\u003eSSHv2, TLSv1.2 and SNMP v3 secure access\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eSNMP Management\n\u003cul\u003e\n\u003cli\u003eFour RMON groups (history, statistics, alarms, and events) \u003c\/li\u003e\n\u003cli\u003eSNMP trap for interface Link Up and Link Down notification\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIPv6\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIP address\/NTP\/DNS management\u003c\/li\u003e\n\u003cli\u003eBuilt-in Trivial File Transfer Protocol (TFTP) client\u003c\/li\u003e\n\u003cli\u003eBOOTP and DHCP for IP address assignment\u003c\/li\u003e\n\u003cli\u003eSystem Maintenance\n\u003cul\u003e\n\u003cli\u003eFirmware upload\/download via HTTP\u003c\/li\u003e\n\u003cli\u003eReset button for system reboot or reset to factory default\u003c\/li\u003e\n\u003cli\u003eDual images\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eDHCP Relay\u003c\/li\u003e\n\u003cli\u003eDHCP Option 82\u003c\/li\u003e\n\u003cli\u003eDHCP Server\u003c\/li\u003e\n\u003cli\u003eUser Privilege levels control\u003c\/li\u003e\n\u003cli\u003eNetwork Time Protocol (NTP)\u003c\/li\u003e\n\u003cli\u003eNetwork Diagnostic\n\u003cul\u003e\n\u003cli\u003eSFP-DDM (Digital Diagnostic Monitor)\u003c\/li\u003e\n\u003cli\u003eCable diagnostic technology provides the mechanism to detect and report potential cabling issues\u003c\/li\u003e\n\u003cli\u003eICMPv6\/ICMPv4 remote ping\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eSMTP\/Syslog remote alarm\u003c\/li\u003e\n\u003cli\u003eSystem Log\u003c\/li\u003e\n\u003cli\u003ePLANET Smart Discovery Utility for deployment management\u003c\/li\u003e\n\u003cli\u003ePLANET UNI-NMS (Universal Network Management) and CloudViewerPro app for deployment management\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ctable class=\"table table-sm table-bordered-bone table-striped-blue table-header-theme-blue table-header-no-border\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\"\u003eHardware Specifications\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eCopper Ports\u003c\/td\u003e\n\u003ctd\u003e16 10\/100\/1000BASE-T RJ45 auto-MDI\/MDI-X ports\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eSFP Ports\u003c\/td\u003e\n\u003ctd\u003e-\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eSFP+ Ports\u003c\/td\u003e\n\u003ctd\u003e4 10GBASE-SR\/LR SFP+ slot interfaces (Port-17 to Port-20)\u003cbr\u003eCompatible with 1000BASE-SX\/LX\/BX and 2500BASE-X SFP transceiver\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eConsole\u003c\/td\u003e\n\u003ctd\u003e1 x RJ45-to-RS232 serial port (115200, 8, N, 1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eSDRAM\u003c\/td\u003e\n\u003ctd\u003e512Mbytes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eFlash Memory\u003c\/td\u003e\n\u003ctd\u003e64Mbytes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eReset Button\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 5 sec: System reboot\u003cbr\u003e\u0026gt; 5 sec: Factory default\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eConnector\u003c\/td\u003e\n\u003ctd\u003eRemovable 6-pin terminal block for power input\u003cbr\u003ePin 1\/2 for Power 1, Pin 3\/4 for fault alarm, Pin 5\/6 for Power 2\u003cbr\u003eRemovable 6-pin terminal block for DI\/DO interface\u003cbr\u003ePin 1\/2 for DI 1 \u0026amp; 2, Pin 3\/4 for DO 1 \u0026amp; 2, Pin 5\/6 for GND\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eAlarm\u003c\/td\u003e\n\u003ctd\u003eOne relay output for power failure. Alarm relay current carry ability: 1A @ 24V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eDigital Input (DI)\u003c\/td\u003e\n\u003ctd\u003e2 digital input:\u003cbr\u003e　Level 0: -24~2.1V (±0.1V)\u003cbr\u003e　Level 1: 2.1~24V (±0.1V)\u003cbr\u003e　Input load to 24V DC, 10mA max.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eDigital Output (DO)\u003c\/td\u003e\n\u003ctd\u003e2 digital output:\u003cbr\u003e　Open collector to 24VDC, 100mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eInstallation\u003c\/td\u003e\n\u003ctd\u003eDIN-rail or wall mounting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eEnclosure\u003c\/td\u003e\n\u003ctd\u003eIP30 aluminum case\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eDimensions (W x D x H)\u003c\/td\u003e\n\u003ctd\u003e96 x 107 x 152 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1,503 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003ePower Requirements\u003c\/td\u003e\n\u003ctd\u003eDC 9~48V, 3.3A max.\u003cbr\u003eAC 24V, 2A max.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eDC input:\u003cbr\u003e　Max. 14.4 watts\/49.13 BTU (system on)\u003cbr\u003e　Max. 24 watts\/81.89 BTU (Full loading)\u003cbr\u003eAC 24V input:\u003cbr\u003e　Max. 13.5 watts\/46.06 BTU (system on)\u003cbr\u003e　Max. 23 watts\/78.48 BTU (Full loading)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eESD Protection\u003c\/td\u003e\n\u003ctd\u003e6KV DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eSurge Protection\u003c\/td\u003e\n\u003ctd\u003e4KV DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eLED Indicators\u003c\/td\u003e\n\u003ctd\u003e\n\u003cb\u003eSystem:\u003c\/b\u003e\u003cbr\u003e　Power 1 (\u003cspan style=\"color: green;\"\u003e\u003cb\u003eGreen\u003c\/b\u003e\u003c\/span\u003e), Power 2 (\u003cspan style=\"color: green;\"\u003e\u003cb\u003eGreen\u003c\/b\u003e\u003c\/span\u003e)\u003cbr\u003e　Fault Alarm (\u003cspan style=\"color: red;\"\u003e\u003cb\u003eRed\u003c\/b\u003e\u003c\/span\u003e)\u003cbr\u003e　Ring (\u003cspan style=\"color: green;\"\u003e\u003cb\u003eGreen\u003c\/b\u003e\u003c\/span\u003e), Ring Owner (\u003cspan style=\"color: green;\"\u003e\u003cb\u003eGreen\u003c\/b\u003e\u003c\/span\u003e)\u003cbr\u003e　DIDO (\u003cspan style=\"color: red;\"\u003e\u003cb\u003eRed\u003c\/b\u003e\u003c\/span\u003e)\u003cbr\u003e\u003cb\u003ePer 10\/100\/1000T RJ45 Port:\u003c\/b\u003e\u003cbr\u003e　1000Mbps LNK\/ACT (\u003cspan style=\"color: green;\"\u003e\u003cb\u003eGreen\u003c\/b\u003e\u003c\/span\u003e)\u003cbr\u003e　10\/100Mbps LNK\/ACT (\u003cspan style=\"color: orange;\"\u003e\u003cb\u003eAmber\u003c\/b\u003e\u003c\/span\u003e)\u003cbr\u003e\u003cb\u003ePer SFP+ Port:\u003c\/b\u003e\u003cbr\u003e　1G\/2.5G LNK\/ACT (\u003cspan style=\"color: green;\"\u003e\u003cb\u003eGreen\u003c\/b\u003e\u003c\/span\u003e)\u003cbr\u003e　10Gbps LNK\/ACT (\u003cspan style=\"color: orange;\"\u003e\u003cb\u003eAmber\u003c\/b\u003e\u003c\/span\u003e)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\"\u003eSwitching Specifications\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eSwitch Architecture\u003c\/td\u003e\n\u003ctd\u003eStore-and-Forward\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eSwitch Fabric\u003c\/td\u003e\n\u003ctd\u003e112Gbps\/non-blocking\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eThroughput\u003c\/td\u003e\n\u003ctd\u003e83.3Mbps@64Bytes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eAddress Table\u003c\/td\u003e\n\u003ctd\u003e32K entries, automatic source address learning and aging\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eShared Data Buffer\u003c\/td\u003e\n\u003ctd\u003e32Mbits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eFlow Control\u003c\/td\u003e\n\u003ctd\u003eIEEE 802.3x pause frame for full duplex\u003cbr\u003eBack pressure for half duplex\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eJumbo Frame\u003c\/td\u003e\n\u003ctd\u003e10K bytes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\"\u003eLayer 3 Functions\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eIP Interfaces\u003c\/td\u003e\n\u003ctd\u003eMax. 128 VLAN interfaces\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eRouting Table\u003c\/td\u003e\n\u003ctd\u003eMax. 128 routing entries\u003cbr\u003eMax. 4K H\/W routing table entries\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eRouting Protocols\u003c\/td\u003e\n\u003ctd\u003eIPv4 RIPv1\/v2 for dynamic routing\u003cbr\u003eIPv4 OSPFv2 for dynamic routing\u003cbr\u003eIPv4 hardware static routing\u003cbr\u003eIPv6 OSPFv3 for dynamic routing\u003cbr\u003eIPv6 hardware static routing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\"\u003eLayer 2 Functions\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003ePort Configuration\u003c\/td\u003e\n\u003ctd\u003ePort disable\/enable\u003cbr\u003eAuto-negotiation 10\/100\/1000Mbps full and half duplex mode selection\u003cbr\u003eFlow control disable\/enable\u003cbr\u003ePort link capability control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003ePort Status\u003c\/td\u003e\n\u003ctd\u003eDisplay each port’s speed duplex mode, link status, flow control status, auto-negotiation status, trunk status\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003ePort Mirroring\u003c\/td\u003e\n\u003ctd\u003eTX\/RX\/Both\u003cbr\u003eMany-to-1 monitor\u003cbr\u003eRMirror – Remote Switched Port Analyzer (Cisco RSPAN)\u003cbr\u003eSupports up to 5 sessions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eVLAN\u003c\/td\u003e\n\u003ctd\u003eIEEE 802.1Q tagged VLAN\u003cbr\u003eIEEE 802.1ad Q-in-Q tunneling\u003cbr\u003ePrivate VLAN Edge (PVE)\u003cbr\u003eMAC-based VLAN\u003cbr\u003eProtocol-based VLAN\u003cbr\u003eVoice VLAN\u003cbr\u003eMVR (Multicast VLAN registration)\u003cbr\u003eGVRP (GARP VLAN Registration Protocol)\u003cbr\u003eUp to 4K VLAN groups, out of 4096 VLAN IDs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eSpanning Tree Protocol\u003c\/td\u003e\n\u003ctd\u003eIEEE 802.1D Spanning Tree Protocol\u003cbr\u003eIEEE 802.1w Rapid Spanning Tree Protocol\u003cbr\u003eIEEE 802.1s Multiple Spanning Tree Protocol\u003cbr\u003eBPDU Guard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eLink Aggregation\u003c\/td\u003e\n\u003ctd\u003eIEEE 802.3ad LACP\/static trunk\u003cbr\u003e10 trunk groups with 16 ports per trunk group\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eIGMP Snooping\u003c\/td\u003e\n\u003ctd\u003eIPv4 IGMP (v1\/v2\/v3) snooping\u003cbr\u003eIPv4 IGMP querier mode support\u003cbr\u003eSupports 255 IGMP groups\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eMLD Snooping\u003c\/td\u003e\n\u003ctd\u003eIPv6 MLD (v1\/v2) snooping,\u003cbr\u003eIPv6 MLD querier mode support\u003cbr\u003eSupports 255 MLD groups\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eRing\u003c\/td\u003e\n\u003ctd\u003eSupports ERPS, and complies with ITU-T G.8032\u003cbr\u003eSupports major ring and sub-ring\u003cbr\u003eRecovery time \u0026lt; 10ms @ 3 units\u003cbr\u003eRecovery time \u0026lt; 50ms @ 16 units\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eSynchronization\u003c\/td\u003e\n\u003ctd\u003eIEEE 1588v2 PTP(Precision Time Protocol)\u003cbr\u003e　Peer-to-peer transparent clock\u003cbr\u003e　End-to-end transparent clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eQoS\u003c\/td\u003e\n\u003ctd\u003eTraffic classification based, strict priority and WRR\u003cbr\u003e8-level priority for switching:\u003cbr\u003e　Port number\u003cbr\u003e　802.1p priority\u003cbr\u003e　802.1Q VLAN tag\u003cbr\u003e　DSCP\/ToS field in IP packet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eBandwidth Control\u003c\/td\u003e\n\u003ctd\u003ePer port bandwidth control\u003cbr\u003eIngress: 100Kbps~1000Mbps\u003cbr\u003eEgress: 100Kbps~1000Mbps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\"\u003eSecurity Functions\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eAccess Control List\u003c\/td\u003e\n\u003ctd\u003eIP-based ACL\/MAC-based ACL\u003cbr\u003eACL based on:\u003cbr\u003e　MAC Address\u003cbr\u003e　IP Address\u003cbr\u003e　Ethertype\u003cbr\u003e　Protocol Type\u003cbr\u003e　VLAN ID\u003cbr\u003e　DSCP\u003cbr\u003e　802.1p Priority\u003cbr\u003eUp to 512 entries\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eSecurity\u003c\/td\u003e\n\u003ctd\u003ePort security\u003cbr\u003eIP source guard, up to 512 entries\u003cbr\u003eDynamic ARP inspection, up to 1K entries\u003cbr\u003eCommand line authority control based on user level\u003cbr\u003eStatic MAC address, up to 64 entries\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eAAA\u003c\/td\u003e\n\u003ctd\u003eRADIUS client\u003cbr\u003eTACACS+ client\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eNetwork Access Control\u003c\/td\u003e\n\u003ctd\u003eIEEE 802.1x port-based network access control\u003cbr\u003eMAC-based authentication\u003cbr\u003eLocal\/RADIUS authentication\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\"\u003eManagement\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eBasic Management Interfaces\u003c\/td\u003e\n\u003ctd\u003eConsole; Telnet; Web browser; SNMP v1, v2c\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eSecure Management Interfaces\u003c\/td\u003e\n\u003ctd\u003eSSHv2, TLS v1.2, SNMPv3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eSystem Management\u003c\/td\u003e\n\u003ctd\u003eFirmware upgrade by HTTP protocol through Ethernet network\u003cbr\u003eConfiguration upload\/download through HTTP\u003cbr\u003eRemote Syslog\u003cbr\u003eSystem log\u003cbr\u003eLLDP protocol\u003cbr\u003eNTP\u003cbr\u003ePLANET Smart Discovery Utility\u003cbr\u003ePLANET CloudViewerPro app\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eEvent Management\u003c\/td\u003e\n\u003ctd\u003eRemote syslog\u003cbr\u003eSystem log\u003cbr\u003eSMTP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eSNMP MIBs\u003c\/td\u003e\n\u003ctd\u003eRFC 1213 MIB-II\u003cbr\u003eRFC 1493 Bridge MIB\u003cbr\u003eRFC 1643 Ethernet MIB\u003cbr\u003eRFC 2863 Interface MIB\u003cbr\u003eRFC 2665 Ether-Like MIB\u003cbr\u003eRFC 2819 RMON MIB (Group 1, 2, 3 and 9)\u003cbr\u003eRFC 2737 Entity MIB\u003cbr\u003eRFC 2618 RADIUS Client MIB\u003cbr\u003eRFC 2863 IF-MIB\u003cbr\u003eRFC 2933 IGMP-STD-MIB\u003cbr\u003eRFC 3411 SNMP-Frameworks-MIB\u003cbr\u003eRFC 4292 IP Forward MIB\u003cbr\u003eRFC 4293 IP MIB\u003cbr\u003eRFC 4836 MAU-MIB\u003cbr\u003eIEEE 802.1X PAE\u003cbr\u003eLLDP\u003cbr\u003eMAU-MIB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\"\u003eStandards Conformance\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eRegulatory Compliance\u003c\/td\u003e\n\u003ctd\u003eFCC Part 15 Class A, CE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eStability Testing\u003c\/td\u003e\n\u003ctd\u003eIEC60068-2-32 (free fall)\u003cbr\u003eIEC60068-2-27 (shock)\u003cbr\u003eIEC60068-2-6 (vibration)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eStandards Compliance\u003c\/td\u003e\n\u003ctd\u003eIEEE 802.3 10BASE-T\u003cbr\u003eIEEE 802.3u 100BASE-TX\/100BASE-FX\u003cbr\u003eIEEE 802.3z Gigabit SX\/LX\u003cbr\u003eIEEE 802.3ab Gigabit 1000T\u003cbr\u003eIEEE 802.3ae 10Gb\/s Ethernet\u003cbr\u003eIEEE 802.3x flow control and back pressure\u003cbr\u003eIEEE 802.3ad port trunk with LACP\u003cbr\u003eIEEE 802.1D Spanning Tree Protocol\u003cbr\u003eIEEE 802.1w Rapid Spanning Tree Protocol\u003cbr\u003eIEEE 802.1s Multiple Spanning Tree Protocol\u003cbr\u003eIEEE 802.1p Class of Service\u003cbr\u003eIEEE 802.1Q VLAN tagging\u003cbr\u003eIEEE 802.1ad Q-in-Q VLAN stacking\u003cbr\u003eIEEE 802.1X Port Authentication Network Control\u003cbr\u003eIEEE 802.1ab LLDP\u003cbr\u003eIEEE 802.3ah OAM\u003cbr\u003eIEEE 802.1ag Connectivity Fault Management (CFM)\u003cbr\u003eIEEE 802.3az Energy Efficient Ethernet (EEE)\u003cbr\u003eIEEE 1588 PTPv2\u003cbr\u003eRFC 768 UDP\u003cbr\u003eRFC 1350 TFTP\u003cbr\u003eRFC 791 IP\u003cbr\u003eRFC 792 ICMP\u003cbr\u003eRFC 2068 HTTP\u003cbr\u003eRFC 1058 RIP v1\u003cbr\u003eRFC 2453 RIP v2\u003cbr\u003eRFC 1112 IGMP v1\u003cbr\u003eRFC 2236 IGMP v2\u003cbr\u003eRFC 3376 IGMP v3\u003cbr\u003eRFC 2710 MLD v1\u003cbr\u003eRFC 3810 MLD v2\u003cbr\u003eRFC 2328 OSPF v2\u003cbr\u003eRFC 2740 OSPF v3\u003cbr\u003eITU-T G.8032 ERPS Ring\u003cbr\u003eITU-T Y.1731 Performance Monitoring\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\"\u003eEnvironment\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eOperating\u003c\/td\u003e\n\u003ctd\u003eTemperature: -40 ~ 75 degrees C\u003cbr\u003eRelative Humidity: 5 ~ 95% (non-condensing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"align-middle\"\u003eStorage\u003c\/td\u003e\n\u003ctd\u003eTemperature: -40 ~ 85 degrees C\u003cbr\u003eRelative Humidity: 5 ~ 95% (non-condensing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Planet","offers":[{"title":"Default Title","offer_id":48892939895040,"sku":"IGS-6325-16T4X","price":1743.28,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0388\/5331\/2557\/files\/box_IGS-6325-16T4X.jpg?v=1782490923","url":"https:\/\/alotechparts.com\/products\/planet-igs-6325-16t4x-ip30-industrial-l3-16-port-101001000t-4-port-10g-sfp-ma","provider":"Alo Tech Solutions","version":"1.0","type":"link"}