{"product_id":"pfc-6075-potter-75-point-analogaddressable-fire-alarm-control-panel-with-ethernet-and-ip-communication","title":"PFC-6075 | Potter 75-Point Analog\/Addressable Fire Alarm Control Panel with Ethernet and IP Communication","description":"\u003ch4\u003eDescription \u003c\/h4\u003e\n\u003cp data-start=\"144\" data-end=\"396\"\u003eThe Potter PFC-6075 is a 75-point analog\/addressable fire alarm control panel designed to manage a wide range of fire detection and notification devices. It supports flexible wiring configurations without the need for twisted or shielded cables, offering simplified installation and dependable system performance. Engineered for commercial and institutional applications, the PFC-6075 provides advanced fire protection monitoring and control in a compact, user-friendly design.\u003c\/p\u003e\n\u003cp data-start=\"284\" data-end=\"574\" class=\"\"\u003e \u003c\/p\u003e\n\u003cp data-start=\"284\" data-end=\"574\" class=\"\"\u003e \u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications \u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNew\/Never Used Surplus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePotter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFire Safety\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePFC-6075\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSubcategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFire Alarm Control Panels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSystem Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAnalog\/Addressable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Points\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e75 Addressable Points\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Supply\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5 Amps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNAC Circuits\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4 Total (2 Regulated 3A, 2 I\/O 1A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNetwork Connectivity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEthernet Port\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEvent History Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1,000 Events\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSupported Devices\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePotter\/Nohmi Protocol Modules and Detectors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStrobe Synchronization\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCompatible with Potter\/AMSECO®, Gentex®, Cooper Wheelock®, and System Sensor®\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCompliance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNFPA 72 Compliant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCommunication Options\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP Communicator and Optional 2-Line DACT (UD-1000)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e120 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWall-Mount, Surface Enclosure\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCabinet Size (W x H x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16″ x 17″ x 3 ⅞″\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e32°F to 120°F (0°C to 49°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaterial\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMetal Cabinet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUnited States\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eInformation About \u003cmeta charset=\"utf-8\"\u003e \u003cmeta charset=\"utf-8\"\u003e \u003cspan data-sheets-root=\"1\"\u003ePFC-6075\u003c\/span\u003e\n\u003c\/h4\u003e\n\u003cp\u003eThe PFC-6075 is part of Potter’s addressable fire alarm control panel series, utilizing the Potter\/Nohmi device protocol for seamless integration with a complete line of detectors and modules. This panel supports up to seventy-five addressable points, allowing for any mix of smoke sensors, heat detectors, or input\/output modules. Featuring an integrated 5-amp power supply and four NAC circuits, it ensures reliable power delivery to notification appliances. The PFC-6075 also includes advanced networking capabilities, such as an Ethernet port for programming and system communication, along with built-in IP and DACT communication options for remote monitoring.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e75 Addressable Points: Supports any combination of analog detectors, modules, and sensors for flexible system design.\u003c\/li\u003e\n\u003cli\u003eIntegrated 5-Amp Power Supply: Provides ample power for notification appliances and system accessories.\u003c\/li\u003e\n\u003cli\u003eFour NAC Circuits: Includes two regulated 3A circuits and two 1A input\/output circuits for versatile device connections.\u003c\/li\u003e\n\u003cli\u003eComprehensive Strobe Synchronization: Compatible with Potter\/AMSECO®, Gentex®, Cooper Wheelock®, and System Sensor® devices.\u003c\/li\u003e\n\u003cli\u003eBuilt-In Diagnostics: Includes smoke drift compensation, maintenance alerts, and NFPA 72-compliant sensitivity testing.\u003c\/li\u003e\n\u003cli\u003eNetwork and Email Communication: Ethernet port supports programming, event reporting, and email notifications.\u003c\/li\u003e\n\u003cli\u003eEvent History Buffer: Stores up to 1,000 system events for easy tracking and review.\u003c\/li\u003e\n\u003cli\u003eExpandable Cabinet Design: Accommodates up to 18 AH batteries for extended backup operation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe PFC-6075 delivers the reliability and precision required for advanced fire alarm management in commercial and industrial environments.\u003c\/p\u003e","brand":"Potter","offers":[{"title":"Default Title","offer_id":49105144414464,"sku":"PFC-6075","price":2072.7,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0388\/5331\/2557\/files\/PFC-6075.png?v=1785541237","url":"https:\/\/alotechparts.com\/products\/pfc-6075-potter-75-point-analogaddressable-fire-alarm-control-panel-with-ethernet-and-ip-communication","provider":"Alo Tech Solutions","version":"1.0","type":"link"}