{"product_id":"pdg23m0030tffl-eaton-3-pole-circuit-breaker","title":"PDG23M0030TFFL | Eaton 3 Pole Circuit Breaker","description":"\u003ch4\u003eDescription \u003c\/h4\u003e\n\u003cp\u003eEaton PDG23M0030TFFL is a 3-pole, 30A molded case circuit breaker from the Power Defense series. It features a thermal-magnetic trip unit (LI), supports up to 600VAC, and offers high interrupting capacity (65kA at 480VAC). UL 489 and IEC compliant, suitable for global applications.\u003c\/p\u003e\n\u003cp data-start=\"284\" data-end=\"574\" class=\"\"\u003e \u003c\/p\u003e\n\u003cp data-start=\"284\" data-end=\"574\" class=\"\"\u003e \u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications \u003c\/h4\u003e\n\u003ctable width=\"100%\" style=\"height: 450.8px; width: 100%;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003cth style=\"width: 32.8533%; text-align: left; height: 19.6px;\" class=\"text-left text-body1 text-bold py-10 pr-10 desktop:pr-[10rem] desktop:text-nowrap\"\u003eCondition\u003c\/th\u003e\n\u003ctd style=\"width: 66.9772%; height: 19.6px;\" class=\"text-left text-body1 py-10 desktop:w-[60%]\"\u003eNew\/Never Used Surplus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003cth style=\"width: 32.8533%; text-align: left; height: 19.6px;\" class=\"text-left text-body1 text-bold py-10 pr-10 desktop:pr-[10rem] desktop:text-nowrap\"\u003eBrand\u003c\/th\u003e\n\u003ctd style=\"width: 66.9772%; height: 19.6px;\" class=\"text-left text-body1 py-10 desktop:w-[60%]\"\u003e\u003cspan data-sheets-root=\"1\"\u003eEaton \u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003cth style=\"width: 32.8533%; text-align: left; height: 19.6px;\"\u003eCategory\u003c\/th\u003e\n\u003ctd style=\"width: 66.9772%; height: 19.6px;\"\u003e\n\u003cdiv class=\"mt-1 md:mt-0 column-left basis-2\/4 divide-y divide-rad-gray-10 border-b-[0.0625rem] border-rad-gray-10 md:border-0\"\u003e\n\u003cdiv class=\"flex gap-[1.75rem] md:gap-x-0 xl:gap-x-[1.875rem]\"\u003e\n\u003cdiv class=\"text-body-4 w-full font-light py-5 pl-4 md:py-6 md:pl-6 text-rad-gray-70\"\u003e\n\u003cdiv class=\"max-w-[8rem] break-words\"\u003e\n\u003cspan\u003e\u003c\/span\u003e\u003cspan\u003eCircuit Breakers\u003c\/span\u003e\u003cbr\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003cth style=\"width: 32.8533%; text-align: left; height: 19.6px;\"\u003e\u003cspan\u003ePart Number\u003c\/span\u003e\u003c\/th\u003e\n\u003ctd style=\"width: 66.9772%; height: 19.6px;\"\u003e\u003cspan data-sheets-root=\"1\"\u003ePDG23M0030TFFL\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003cth style=\"width: 32.8533%; text-align: left; height: 19.6px;\"\u003e\u003cspan\u003eSubcategory\u003c\/span\u003e\u003c\/th\u003e\n\u003ctd style=\"width: 66.9772%; height: 19.6px;\"\u003e\u003cspan data-sheets-root=\"1\"\u003e\u003cspan\u003eMolded Case Circuit Breakers\u003c\/span\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003cth class=\"text-left text-body1 text-bold py-10 pr-10 desktop:pr-[10rem] desktop:text-nowrap\" style=\"width: 32.8533%; height: 19.6px; text-align: left;\"\u003eAmperage Rating\u003c\/th\u003e\n\u003ctd class=\"text-left text-body1 py-10 desktop:w-[60%]\" style=\"width: 66.9772%; height: 19.6px;\"\u003e\n\u003cspan\u003e30 A\u003c\/span\u003e\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.2px;\"\u003e\n\u003cth style=\"width: 32.8533%; text-align: left; height: 39.2px;\"\u003eCircuit Breaker Frame Type\u003c\/th\u003e\n\u003ctd style=\"width: 66.9772%; height: 39.2px;\"\u003e\u003cspan\u003eComplete breaker\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003cth style=\"width: 32.8533%; text-align: left; height: 19.6px;\"\u003eFrame\u003c\/th\u003e\n\u003ctd style=\"width: 66.9772%; height: 19.6px;\"\u003e\u003cspan\u003e2\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003cth style=\"width: 32.8533%; text-align: left; height: 19.6px;\"\u003eNumber of Poles\u003c\/th\u003e\n\u003ctd style=\"width: 66.9772%; height: 19.6px;\"\u003e\u003cspan\u003eThree-pole\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003cth style=\"width: 32.8533%; text-align: left; height: 19.6px;\"\u003eCircuit Breaker Type\u003c\/th\u003e\n\u003ctd style=\"width: 66.9772%; height: 19.6px;\"\u003e\u003cspan\u003ePD2 Global\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003cth style=\"width: 32.8533%; text-align: left; height: 19.6px;\"\u003eClass\u003c\/th\u003e\n\u003ctd style=\"width: 66.9772%; height: 19.6px;\"\u003e\u003cspan\u003eClass A\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003cth style=\"width: 32.8533%; text-align: left; height: 19.6px;\"\u003eTrip Type\u003c\/th\u003e\n\u003ctd style=\"width: 66.9772%; height: 19.6px;\"\u003e\u003cspan\u003eT298\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003cth style=\"width: 32.8533%; text-align: left; height: 19.6px;\"\u003eVoltage Rating\u003c\/th\u003e\n\u003ctd class=\"specification-value\" style=\"width: 66.9772%; height: 19.6px;\"\u003e\n\u003cdiv class=\"module-table__value value-type-default\"\u003e\u003cspan class=\"specification-value-secondary\"\u003e600 Vac\u003c\/span\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003cth style=\"width: 32.8533%; text-align: left; height: 19.6px;\"\u003eInterrupt Rating\u003c\/th\u003e\n\u003ctd style=\"width: 66.9772%; height: 19.6px;\"\u003e\u003cspan\u003e65 kAIC at 480 Vac\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003cth style=\"width: 32.8533%; text-align: left; height: 19.6px;\"\u003e\u003cspan\u003eConnection Type\u003c\/span\u003e\u003c\/th\u003e\n\u003ctd style=\"width: 66.9772%; height: 19.6px;\"\u003e\u003cspan\u003eBolt-On\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003cth style=\"width: 32.8533%; text-align: left; height: 19.6px;\"\u003e\u003cspan\u003eProtection\u003c\/span\u003e\u003c\/th\u003e\n\u003ctd style=\"width: 66.9772%; height: 19.6px;\"\u003e\u003cspan\u003eThermal Magnetic\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003cth style=\"width: 32.8533%; text-align: left; height: 19.6px;\"\u003e\u003cspan\u003eTerminal Connection\u003c\/span\u003e\u003c\/th\u003e\n\u003ctd style=\"width: 66.9772%; height: 19.6px;\"\u003e\u003cspan\u003eLoad side lug\u003cbr\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003cth style=\"width: 32.8533%; text-align: left; height: 19.6px;\"\u003e\u003cspan\u003eStandards\u003c\/span\u003e\u003c\/th\u003e\n\u003ctd style=\"width: 66.9772%; height: 19.6px;\"\u003e\u003cspan\u003eRoHS\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003cth style=\"width: 32.8533%; text-align: left; height: 19.6px;\"\u003eLength\/Depth\u003c\/th\u003e\n\u003ctd style=\"width: 66.9772%; height: 19.6px;\"\u003e\u003cspan\u003e88.9 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003cth style=\"width: 32.8533%; text-align: left; height: 19.6px;\"\u003eHeight\u003c\/th\u003e\n\u003ctd style=\"width: 66.9772%; height: 19.6px;\"\u003e\u003cspan\u003e152.4 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003cth style=\"width: 32.8533%; text-align: left; height: 19.6px;\"\u003eWidth\u003c\/th\u003e\n\u003ctd style=\"width: 66.9772%; height: 19.6px;\"\u003e\u003cspan\u003e104.6 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003cth style=\"width: 32.8533%; text-align: left; height: 19.6px;\"\u003eWeight\u003c\/th\u003e\n\u003ctd style=\"width: 66.9772%; height: 19.6px;\"\u003e\u003cspan\u003e1.82 kgs\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003cspan style=\"font-size: 0.875rem;\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eInformation About PDG23M0030TFFL\u003c\/h4\u003e\n\u003cp\u003eThe PDG23M0030TFFL is part of Eaton’s Power Defense molded case circuit breaker line—robust, globally certified breakers engineered for reliable circuit protection in industrial and commercial electrical systems. This 3-pole, bolt-on model features a fixed thermal-magnetic (LI) trip unit and delivers exceptional performance with interrupting capacities up to 65 kA at 480 VAC. Designed for panelboard or switchgear integration, it operates at voltages up to 600 VAC, offering a compact solution for overcurrent protection in demanding applications.\u003c\/p\u003e\n\u003ch4\u003eKey Features:\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e3-Pole Protection: Supports three-phase electrical systems, making it ideal for industrial motor loads, HVAC, and lighting circuits.\u003c\/li\u003e\n\u003cli\u003eFixed Thermal-Magnetic Trip Unit: Provides dependable long-time (overload) and instantaneous (short-circuit) protection without adjustments—ensuring consistent, maintenance-free operation.\u003c\/li\u003e\n\u003cli\u003eHigh Interrupting Capacity: Rated for up to 65 kA at 480 VAC, allowing safe interruption of high fault currents in mission-critical environments.\u003c\/li\u003e\n\u003cli\u003eBolt-On Mounting: Designed for secure, panel-mounted installation with standard line\/load lug terminals for quick field wiring.\u003c\/li\u003e\n\u003cli\u003eGlobal Standards Compliance: UL 489 listed, IEC 60947-2 compliant, and certified for CSA, CCC, and RoHS—ensuring compatibility with international projects.\u003c\/li\u003e\n\u003cli\u003eCompact Frame: Eaton’s Frame 2 design fits in limited-space enclosures while supporting rugged duty cycles and high-performance demands.\u003c\/li\u003e\n\u003cli\u003eDurable Construction: Built with industrial-grade materials and thermal tolerance suitable for switchgear rooms, MCCs, and harsh facility conditions.\u003c\/li\u003e\n\u003cli\u003eVoltage Versatility: Operates at up to 600 VAC, supporting standard low-voltage power distribution across North American and global sites.\u003c\/li\u003e\n\u003cli\u003eEase of Integration: Compatible with Power Defense accessories, metering, and diagnostic modules for system-level monitoring and control.\u003c\/li\u003e\n\u003cli\u003eApplication Flexibility: Ideal for panelboards, switchboards, motor control centers, and OEM equipment requiring compact, high-performance circuit protection.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe Eaton PDG23M0030TFFL molded case breaker delivers compact protection with high fault interruption, thermal-magnetic reliability, and global certification—making it an excellent choice for panel builders, OEMs, and electrical contractors working across a wide range of industrial and commercial environments.\u003c\/p\u003e","brand":"Eaton","offers":[{"title":"Default Title","offer_id":49105284399360,"sku":"PDG23M0030TFFL","price":1080.45,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0388\/5331\/2557\/files\/PDG23M0030TFFJ-All-New-1_adce1bac-583c-4d5d-a2a7-5229c4a3f071.jpg?v=1785544076","url":"https:\/\/alotechparts.com\/products\/pdg23m0030tffl-eaton-3-pole-circuit-breaker","provider":"Alo Tech Solutions","version":"1.0","type":"link"}