{"product_id":"oxygen-deficiency-and-enrichment-safety-monitoring-system","title":"Oxygen Deficiency and Enrichment Safety Monitoring System","description":"\u003cp\u003eThe \u003cstrong\u003e\u003cspan style=\"color: rgb(24, 114, 124);\"\u003eOxygen Deficiency and Enrichment Safety Monitoring System\u003c\/span\u003e \u003c\/strong\u003eis a fully integrated O2 safety solution designed to detect hazardous \u003cstrong\u003eoxygen depletion and oxygen enrichment conditions\u003c\/strong\u003e, including risks associated with argon or helium displacement.\u003c\/p\u003e\n\u003cp\u003eThe system provides immediate \u003cstrong\u003eaudible, visual, and power-status alerts\u003c\/strong\u003e to protect personnel in enclosed or oxygen-altered environments.\u003c\/p\u003e\n\u003cp\u003eThis all-in-one monitoring kit supports \u003cstrong\u003ecode compliance and workplace safety\u003c\/strong\u003e by delivering continuous, real-time oxygen detection and multi-layered alarm notifications in the event of dangerous gas levels, oxygen enrichment, or system power failure.\u003c\/p\u003e\n\u003ch4\u003eWhat's Included:\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRAD-0002-ZR-HS2 O2 Safety Alarm - \u003c\/strong\u003eindustry-proven gas detector featuring a clear digital display, depletion and enrichment functionality, multiple alarm setpoints, and relay outputs. Ideal for enclosed spaces with O₂ gas systems.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCM-HS2: Horn\/Strobe Alert Combo - \u003c\/strong\u003eloud 90+ dB horns and high-visibility strobe provide immediate attention-grabbing warnings during elevated O2 conditions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRAD-PMU: Power Monitor Unit - \u003c\/strong\u003econtinuously monitors system power and issues a warning if power is lost ensuring your safety system is never offline unnoticed.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eFeatures\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eProvides 24\/7 protection for you and your staff against oxygen deficiency\u003c\/li\u003e\n\u003cli\u003eAudible and visual alarms on the sensor and horn strobes\u003c\/li\u003e\n\u003cli\u003ePower monitor unit meets IFC codes and alerts in the event of a power loss\u003c\/li\u003e\n\u003cli\u003e3 user-configurable alarms meet \u003ca href=\"\/blogs\/articles\/oxygen-deficiency-monitor\" title=\"osha codes\"\u003eall OSHA codes\u003c\/a\u003e\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eLong-life zirconium oxide sensor, lasts up to 10+ years\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan style=\"color: rgb(0, 0, 0);\"\u003e\u003cstrong\u003e*A surge protector is required for safeguard and longevity of the monitor\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eAdd-On Options\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003ca title=\"Remote CO2 Storage Safety 3 Alarm Add On\" href=\"https:\/\/www.co2meter.com\/products\/remote-co2-storage-safety-add-on\"\u003eRAD-0104\u003c\/a\u003e\u003cspan\u003e \u003c\/span\u003e-\u003c\/strong\u003e Additional Remote Display (Supports up to 3 total)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003ca title=\"central display unit for gas safety alarms\" href=\"https:\/\/www.co2meter.com\/products\/central-display-unit-gas-safety-alarms\"\u003eRAD-CDU-HS1\u003c\/a\u003e\u003cspan\u003e \u003c\/span\u003e- \u003c\/strong\u003eAdditional Centralized Display Unit (Supports 12 sensors)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003ca title=\"Power Monitor Unit for Gas Safety Alarms\" href=\"https:\/\/www.co2meter.com\/products\/power-monitor-gas-safety-alarms\"\u003eRAD-PMU\u003c\/a\u003e \u003c\/strong\u003e- Additional Power Monitor Unit (Alerts if Loss of Power)\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003ca href=\"https:\/\/www.co2meter.com\/collections\/fixed-wall-mount\/products\/remote-co2-storage-safety-alarm-strobe-lights?variant=41757308813510\" title=\"CM-HS2 Horn Strobe Lights\" rel=\"noopener\" target=\"_blank\"\u003eCM-HS2\u003c\/a\u003e\u003ca href=\"https:\/\/www.co2meter.com\/products\/remote-co2-storage-safety-alarm-strobe-lights\" title=\"CM-1027 Strobe Lights\" target=\"_blank\"\u003e\u003c\/a\u003e\u003cspan\u003e \u003c\/span\u003e-\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eadd-on kit includes 2 extension strobe lights and cables\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"specifications\"\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasurement Range:\u003c\/strong\u003e 0-23% display\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDisplay Resolution:\u003c\/strong\u003e 0.1%\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccuracy:\u003c\/strong\u003e Better than 2% FS\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePressure Dependence:\u003c\/strong\u003e Not pressure dependent\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResponse Time:\u003c\/strong\u003e O2: \u0026lt;2min by 90%\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eO2 Deficiency Alarms (default):\u003c\/strong\u003e AL1 19.5%, AL2 16.5%, and AL3 12%.\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eO2 Enrichment Alarms (default): \u003c\/strong\u003eAL1 22%, AL2 24%, and AL3 25%.\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSound Alarm:\u003c\/strong\u003e 90db @ 10cm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAlarm Response Time:\u003c\/strong\u003e \u0026lt; 60 seconds\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarm-Up Time:\u003c\/strong\u003e 600 seconds (10 min) for full operating temperature range\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e -58°F to 122°F (-50°C to 50°C)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSensor Life Expectancy:\u003c\/strong\u003e 10+ years\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 1.5lbs (Monitor only)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions: \u003c\/strong\u003e6.5 x 5.0 x 2.5 in\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eElectrical\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Supply: Output:\u003c\/strong\u003e 12VDC, 2000mA.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Input:\u003c\/strong\u003e 100~240 VAC, 50\/60Hz, 0.6A (25 ft. Ethernet cable - included)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Consumption:\u003c\/strong\u003e 3 Watts\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e6 VDC battery backup connections\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRelays:\u003c\/strong\u003e Peak Current \u0026lt; 2A @ 30 VDC or 250 VAC, SPDT\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e4-20mA output\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWarranty\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 year on the device - \u003ca title=\"CO2Meter Terms and Conditions\" href=\"\/pages\/terms-conditions\"\u003eSee CO2Meter Terms + Conditions.\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"documents\"\u003e\n\u003ch2\u003eDocuments\u003c\/h2\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/Data_Sheet_RAD-0002-ZR-Oxygen_Deficiency_Depletion_Safety_Alarm-powermonitorunit-hornstrobes-KIT_2.pdf?v=1748537458\" title=\"data sheet for the complete o2 deficiency safety monitoring kit\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1094\" alt=\"Datasheet Oxygen Safety Alarm\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/Data_Sheet_RAD-0002-ZR-KIT_Complete_O2_Deficiency_Safety_Monitoring_Kit.pdf?v=1782224650\" title=\"Data Sheet_RAD-0002-ZR-KIT_Complete O2 Deficiency Safety Monitoring Kit - co2meter.com\"\u003e\u003cspan style=\"color: rgb(255, 42, 0);\"\u003e\u003cstrong\u003e RAD-0002-ZR-KIT: Data Sheet (pdf)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/MAN-RAD-0002-ZR-Oxygen-O2-Deficiency-Safety-Alarm-CO2Meter-Rev01.05.pdf\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1094\" alt=\"Manual Oxygen Deficiency Safety Alarm\"\u003e\u003c\/a\u003e\u003ca title=\"Oxygen Deficiency Depletion Safety Alarm Manual\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/MAN-RAD-0002-ZR-Oxygen-O2-Deficiency-Safety-Alarm-CO2Meter-Rev01.05.pdf?v=1768407332\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\"\u003e Manual (pdf)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/RAD-0002-ZR-Installation-Guide_Revised-2025.pdf?v=1742842075\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1094\" alt=\"Installation Guide Oxygen Deficiency Safety Alarm\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\"\u003e Installation Guide (pdf)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/Resetting-Your-RAD-0002-ZR.pdf?v=1683747050\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1094\" alt=\"How to Hard Reset the RAD-0002-ZR\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\"\u003e How to Hard Reset the RAD-0002-ZR (pdf)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/RAD-0002_ZR_FAQs_11_2022.pdf\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1094\" alt=\"Datasheet Oxygen Deficiency Safety Alarm for Low Temperature\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/RAD-0002_ZR_FAQs_REV0726.pdf?v=1784044962\" title=\"FAQs for O2 Monitor\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\"\u003eFAQs (pdf)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/RAD-0002-ZR-Safety-Monitor-AC-DC-Transformer-2023.pdf?v=1683748311\"\u003e\u003cimg alt=\"24VDC Hard wiring instructions\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1094\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\"\u003e Hard Wiring Your Oxygen Deficiency Safety Alarm (pdf)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/RAD-0002-ZR-Exhaust-Fan-Relay-2023.pdf?v=1683748482\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1094\" alt=\"Safety Alarm fan circuit\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\"\u003e Exhaust Fan Relay Wiring Diagram (pdf)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/Relay_Wiring_Diagram_for_SV_REV2.pdf?v=1765227289\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1094\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/Relay_Wiring_Diagram_for_SV-1029-W.pdf\" title=\"SV-1029 Solenoid Valve Wiring Diagram\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\"\u003e SV-1029, SV-1030 Wiring Diagram (pdf)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/Oxygen_OSHA_Warning_Signage.zip?v=1671110540\"\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/assets\/zip.gif\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\"\u003e Oxygen Safety Signage (Included with Purchase) (zip)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/RAD-0002-ZR-O2-Deficiency-Testing-Procedure.pdf?v=1683747735\"\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1094\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\"\u003e RAD-0002-ZR Testing Procedures\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/www.youtube.com\/playlist?list=PLrSaPBRnDkbKPRNE9Mc1cniLOdN-w5nON\" target=\"_blank\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/assets\/youtube.gif\" alt=\"RAD-0002-ZR Oxygen Deficiency Safety Alarm Playlist\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\"\u003e RAD-0002-ZR Playlist: Unboxing, Installation\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/Oxygen_Concentration_Levels_and_Effects.jpg\" title=\"Oxygen Concentration Levels \u0026amp; Effects Chart\" target=\"_blank\"\u003e\u003cstrong\u003e\u003cspan style=\"color: red;\"\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"accessories\"\u003e\n\u003ch2\u003eAccessories\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003ca title=\"Central Display Unit\" href=\"https:\/\/www.co2meter.com\/products\/central-display-unit-gas-safety-alarms\"\u003eRAD-CDU - Central Display Unit.\u003c\/a\u003e \u003c\/strong\u003eA central display that consolidates visual and audible alerts from up to twelve remote CO2 sensors for easy, centralized monitoring.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003ca title=\"Power Monitor Unit\" href=\"https:\/\/www.co2meter.com\/products\/power-monitor-gas-safety-alarms\"\u003eRAD-PMU - Power Monitor Unit.\u003c\/a\u003e \u003c\/strong\u003eA power monitor unit that indicates system status and alarms when the main CO2 safety device loses power\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003ca title=\"Remote CO2 Storage Safety Add-On Display\" href=\"https:\/\/www.co2meter.com\/products\/remote-co2-storage-safety-add-on\"\u003e\u003cstrong\u003eRAD-0104 - Additional Remote Display.\u003c\/strong\u003e\u003c\/a\u003eThe Sensor display unit comes with one remote display that can be placed up to 300ft. away using CAT5 or greater Ethernet cable (28ft. included in the box). Purchase one or two additional remote displays, then daisy-chain them so long as the total run is less than 300 ft.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSV-1029 Solenoid Safety Shut Off Valve 3\/8 inch\u003c\/strong\u003e- designed to be utilized with any of our remote storage safety alarms, and can be directly wired to the SV-1029 24\/DC safety shut-off valve. - \u003cstrong\u003e\u003ca href=\"https:\/\/www.co2meter.com\/pages\/contact\" title=\"Contact Us - co2meter.com\"\u003eContact Us to Order\u003c\/a\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"CO2Meter","offers":[{"title":"RAD-0002-ZR-KIT: Oxygen Deficiency and Enrichment Safety Monitoring System","offer_id":49030513688832,"sku":"RAD-0002-ZR-KIT","price":3017.85,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0388\/5331\/2557\/files\/RAD-0002-ZR-KIT_68a7a073-19d7-47ec-b937-80daefa14728.jpg?v=1784471154","url":"https:\/\/alotechparts.com\/products\/oxygen-deficiency-and-enrichment-safety-monitoring-system","provider":"Alo Tech Solutions","version":"1.0","type":"link"}