{"product_id":"nzm-100-6-notifier-six-zone-conventional-detector-interface-module","title":"NZM-100-6 | Notifier Six-Zone Conventional Detector Interface Module","description":"\u003ch4\u003eDescription \u003c\/h4\u003e\n\u003cp\u003eThe Notifier NZM-100-6 is a six-input zone module that allows integration of conventional two-wire detectors with intelligent fire alarm systems. Designed for flexibility, it supports either six Class B or three Class A circuits, providing seamless communication between conventional detection zones and addressable systems. This compact module ensures reliable supervision, monitoring, and reporting of zone conditions in fire protection networks.\u003c\/p\u003e\n\u003cp data-start=\"284\" data-end=\"574\" class=\"\"\u003e \u003c\/p\u003e\n\u003cp data-start=\"284\" data-end=\"574\" class=\"\"\u003e \u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications \u003c\/h4\u003e\n\u003ctable style=\"width: 100.083%; height: 352.688px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 37.2405%; height: 19.5938px;\"\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 59.6242%; height: 19.5938px;\"\u003eNew\/Never Used Surplus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 37.2405%; height: 19.5938px;\"\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 59.6242%; height: 19.5938px;\"\u003eNotifier\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 37.2405%; height: 19.5938px;\"\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 59.6242%; height: 19.5938px;\"\u003eFire Safety\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 37.2405%; height: 19.5938px;\"\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 59.6242%; height: 19.5938px;\"\u003eNZM-100-6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 37.2405%; height: 19.5938px;\"\u003e\u003cstrong\u003eSubcategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 59.6242%; height: 19.5938px;\"\u003eZone Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 37.2405%; height: 19.5938px;\"\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 59.6242%; height: 19.5938px;\"\u003e6.80 × 5.80 × 1.25 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 37.2405%; height: 19.5938px;\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 59.6242%; height: 19.5938px;\"\u003e1.10 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 37.2405%; height: 19.5938px;\"\u003e\u003cstrong\u003eInputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 59.6242%; height: 19.5938px;\"\u003eSix Class B or three Class A circuits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 37.2405%; height: 19.5938px;\"\u003e\u003cstrong\u003eStandby Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 59.6242%; height: 19.5938px;\"\u003e2.0 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 37.2405%; height: 19.5938px;\"\u003e\u003cstrong\u003eAlarm Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 59.6242%; height: 19.5938px;\"\u003e40 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 37.2405%; height: 19.5938px;\"\u003e\u003cstrong\u003eOperating Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 59.6242%; height: 19.5938px;\"\u003eFrom SLC, system dependent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 37.2405%; height: 19.5938px;\"\u003e\u003cstrong\u003eWire Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 59.6242%; height: 19.5938px;\"\u003e12–18 AWG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 37.2405%; height: 19.5938px;\"\u003e\u003cstrong\u003eIndicators\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 59.6242%; height: 19.5938px;\"\u003ePanel-controlled bi-color LEDs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 37.2405%; height: 19.5938px;\"\u003e\u003cstrong\u003eAddressing\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 59.6242%; height: 19.5938px;\"\u003eRotary switches, 01–159\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 37.2405%; height: 19.5938px;\"\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 59.6242%; height: 19.5938px;\"\u003e32°F to 120°F (0°C to 49°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 37.2405%; height: 19.5938px;\"\u003e\u003cstrong\u003eHumidity Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 59.6242%; height: 19.5938px;\"\u003e10% to 93% non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 37.2405%; height: 19.5938px;\"\u003e\u003cstrong\u003eMounting Options\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 59.6242%; height: 19.5938px;\"\u003eBB-XP, CHS-6 in CAB-3, CAB-4, BB-25\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 37.2405%; height: 19.5938px;\"\u003e\u003cstrong\u003eApprovals\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 59.6242%; height: 19.5938px;\"\u003eUL, ULC, FM, CSFM, MEA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eInformation About NZM-100-6\u003c\/h4\u003e\n\u003cp\u003eThe NZM-100-6 is part of the Notifier FireWarden series of interface modules. It enables fire alarm control panels to connect to conventional two-wire detector circuits while maintaining full supervision and system integrity. Each module uses a common SLC input and supports removable terminal blocks for simplified wiring. Rotary switches provide straightforward addressing, while panel-controlled LED indicators give clear status visibility. With mounting options for multiple cabinets and chassis, the NZM-100-6 adapts to a wide range of installation environments.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eMultiple Circuit Options: Supports six Class B or three Class A initiating device circuits.\u003c\/li\u003e\n\u003cli\u003eEasy Addressing: Rotary address switches simplify configuration and reduce programming errors.\u003c\/li\u003e\n\u003cli\u003eRemovable Terminal Blocks: Accepts 12–18 AWG wiring for straightforward installation.\u003c\/li\u003e\n\u003cli\u003eStatus Indicators: Panel-controlled LEDs display point conditions for clear diagnostics.\u003c\/li\u003e\n\u003cli\u003eFlexible Mounting: Compatible with BB-XP, CHS-6, CAB-3, CAB-4, and BB-25 enclosures.\u003c\/li\u003e\n\u003cli\u003eIndependent Operation: Each circuit functions independently despite sharing common supply and ground.\u003c\/li\u003e\n\u003cli\u003eDisable Unused Addresses: Allows freeing up of unused points for system efficiency.\u003c\/li\u003e\n\u003cli\u003eAgency Approvals: UL, ULC, CSFM, MEA, and FM certified for compliance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe NZM-100-6 delivers the reliability and precision required for professional fire detection system integration.\u003c\/p\u003e","brand":"Notifier","offers":[{"title":"Default Title","offer_id":49105182458112,"sku":"NZM-100-6","price":1542.03,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0388\/5331\/2557\/files\/8c4a736b581547e684e37dfbdd7efc87.jpg?v=1785542032","url":"https:\/\/alotechparts.com\/products\/nzm-100-6-notifier-six-zone-conventional-detector-interface-module","provider":"Alo Tech Solutions","version":"1.0","type":"link"}