{"product_id":"nfw-50x-notifier-fire-alarm-control-panel","title":"NFW-50X | Notifier Fire Alarm Control Panel","description":"\u003ch4\u003eDescription \u003c\/h4\u003e\n\u003cp\u003eThe Notifier NFW-50X is a next-generation addressable fire alarm control panel (FACP) designed for small commercial and institutional applications. It supports up to 50 addressable devices and includes a pre-installed IPOTS-COM dual communicator for internet and phone line connectivity, offering enhanced programming, monitoring, and cost-saving communication options.\u003c\/p\u003e\n\u003cp class=\"\" data-end=\"574\" data-start=\"284\"\u003e \u003c\/p\u003e\n\u003cp class=\"\" data-end=\"574\" data-start=\"284\"\u003e \u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications \u003c\/h4\u003e\n\u003ctable style=\"height: 436.547px; width: 100%;\" width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 32.6094px;\"\u003e\n\u003cth class=\"text-left text-body1 text-bold py-10 pr-10 desktop:pr-[10rem] desktop:text-nowrap\" style=\"width: 31.0909%; text-align: left; height: 32.6094px;\"\u003eCondition\u003c\/th\u003e\n\u003ctd class=\"text-left text-body1 py-10 desktop:w-[60%]\" style=\"width: 68.5455%; height: 32.6094px;\"\u003eNew\/Never Used Surplus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 24px;\"\u003e\n\u003cth class=\"text-left text-body1 text-bold py-10 pr-10 desktop:pr-[10rem] desktop:text-nowrap\" style=\"width: 31.0909%; text-align: left; height: 24px;\"\u003eBrand\u003c\/th\u003e\n\u003ctd class=\"text-left text-body1 py-10 desktop:w-[60%]\" style=\"width: 68.5455%; height: 24px;\"\u003e\u003cspan data-sheets-root=\"1\"\u003eNotifier\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 24px;\"\u003e\n\u003cth style=\"width: 31.0909%; text-align: left; height: 24px;\"\u003eCategory\u003c\/th\u003e\n\u003ctd style=\"width: 68.5455%; height: 24px;\"\u003e\n\u003cdiv class=\"mt-1 md:mt-0 column-left basis-2\/4 divide-y divide-rad-gray-10 border-b-[0.0625rem] border-rad-gray-10 md:border-0\"\u003e\n\u003cdiv class=\"flex gap-[1.75rem] md:gap-x-0 xl:gap-x-[1.875rem]\"\u003e\n\u003cdiv class=\"text-body-4 w-full font-light py-5 pl-4 md:py-6 md:pl-6 text-rad-gray-70\"\u003e\n\u003cdiv class=\"max-w-[8rem] break-words\"\u003e\n\u003cspan\u003e\u003c\/span\u003e\u003cspan\u003eFire Safety\u003c\/span\u003e\u003cbr\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 20.875px;\"\u003e\n\u003cth style=\"width: 31.0909%; text-align: left; height: 20.875px;\"\u003ePart Number\u003c\/th\u003e\n\u003ctd style=\"width: 68.5455%; height: 20.875px;\"\u003e\u003cspan data-sheets-root=\"1\"\u003eNFW-50X\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 27.2188px;\"\u003e\n\u003cth style=\"width: 31.0909%; text-align: left; height: 27.2188px;\"\u003e\u003cspan\u003eSubcategory\u003c\/span\u003e\u003c\/th\u003e\n\u003ctd style=\"width: 68.5455%; height: 27.2188px;\"\u003e\u003cspan data-sheets-root=\"1\"\u003e\u003cspan\u003eFire Alarm Control\u003c\/span\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 32.375px;\"\u003e\n\u003cth style=\"width: 31.0909%; text-align: left; height: 32.375px;\"\u003e\u003cspan\u003eSeries\u003c\/span\u003e\u003c\/th\u003e\n\u003ctd style=\"width: 68.5455%; height: 32.375px;\"\u003e\u003cspan data-sheets-root=\"1\"\u003e\u003cspan\u003eNotifier FireWarden\u003c\/span\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 26.8125px;\"\u003e\n\u003cth style=\"width: 31.0909%; text-align: left; height: 26.8125px;\"\u003e\u003cspan\u003eDevice Capacity\u003c\/span\u003e\u003c\/th\u003e\n\u003ctd style=\"width: 68.5455%; height: 26.8125px;\"\u003e\u003cspan data-sheets-root=\"1\"\u003e\u003cspan\u003e50 addressable devices (detectors\/modules)\u003c\/span\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 28.4688px;\"\u003e\n\u003cth style=\"width: 31.0909%; text-align: left; height: 28.4688px;\"\u003eProtocols Supported\u003c\/th\u003e\n\u003ctd style=\"width: 68.5455%; height: 28.4688px;\"\u003eFlashScan and CLIP\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003cth style=\"width: 31.0909%; text-align: left; height: 39.1875px;\" class=\"text-left text-body1 text-bold py-10 pr-10 desktop:pr-[10rem] desktop:text-nowrap\"\u003ePower Input\u003cbr\u003e\n\u003c\/th\u003e\n\u003ctd style=\"width: 68.5455%; height: 39.1875px;\" class=\"text-left text-body1 py-10 desktop:w-[60%]\"\u003e120\/240 VAC (auto-sensing), 50\/60 Hz, 3.25 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 24.25px;\"\u003e\n\u003cth style=\"width: 31.0909%; text-align: left; height: 24.25px;\"\u003eNAC Circuits\u003c\/th\u003e\n\u003ctd style=\"width: 68.5455%; height: 24.25px;\"\u003e\u003cspan\u003e2 Class A\/B, 250 mA each (2.5 A shared capability)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003cth style=\"width: 31.0909%; text-align: left; height: 19.5938px;\"\u003eSystem Output\u003c\/th\u003e\n\u003ctd style=\"width: 68.5455%; height: 19.5938px;\"\u003e\u003cspan\u003e2.7 A (NACs + ANN-BUS shared)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003cth style=\"width: 31.0909%; text-align: left; height: 19.5938px;\"\u003eCommunication\u003c\/th\u003e\n\u003ctd style=\"width: 68.5455%; height: 19.5938px;\"\u003e\u003cspan\u003eBuilt-in IPOTS-COM (IP + POTS), optional cellular\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003cth style=\"width: 31.0909%; text-align: left; height: 19.5938px;\"\u003eRelays\u003c\/th\u003e\n\u003ctd style=\"width: 68.5455%; height: 19.5938px;\"\u003e\u003cspan\u003e2 programmable Form-C, 1 fixed trouble relay\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003cth style=\"width: 31.0909%; text-align: left; height: 19.5938px;\"\u003eBattery Support\u003c\/th\u003e\n\u003ctd style=\"width: 68.5455%; height: 19.5938px;\"\u003e\u003cspan\u003e(2) 12 V, 7–18 AH lead-acid batteries\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003cth style=\"width: 31.0909%; text-align: left; height: 19.5938px;\"\u003eProgramming Access\u003c\/th\u003e\n\u003ctd style=\"width: 68.5455%; height: 19.5938px;\"\u003e\u003cspan\u003eUSB port, Ethernet (via IPOTS-COM)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003cth style=\"width: 31.0909%; text-align: left; height: 19.5938px;\"\u003eTools\u003c\/th\u003e\n\u003ctd style=\"width: 68.5455%; height: 19.5938px;\"\u003e\u003cspan\u003eFS-Tools Upload\/Download Utility\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003cth style=\"width: 31.0909%; text-align: left; height: 19.5938px;\"\u003eDimensions (W×H×D)\u003c\/th\u003e\n\u003ctd style=\"width: 68.5455%; height: 19.5938px;\"\u003e\u003cspan\u003e23 × 20 × 7 in\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003cth style=\"width: 31.0909%; text-align: left; height: 19.5938px;\"\u003eWeight\u003c\/th\u003e\n\u003ctd style=\"width: 68.5455%; height: 19.5938px;\"\u003e\u003cspan\u003e28 lbs\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003cspan style=\"font-size: 0.875rem;\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eInformation About \u003cspan data-sheets-root=\"1\"\u003eNFW-50X\u003c\/span\u003e\n\u003c\/h4\u003e\n\u003cp\u003eThe NFW-50X replaces the earlier NFW-50 model in the FireWarden Series and supports both FlashScan and CLIP protocols for flexibility with Notifier devices. It features two Class A\/B NAC circuits, providing 250 mA per circuit (2.5 A shared for special applications) and 2.7 A total system output across NACs and ANN-BUS. The panel accepts 120\/240 VAC auto-sensing input, and can house two 18 AH batteries internally for backup power. The included IPOTS-COM communicator supports POTS and IP alarm signaling, reducing reliance on costly dedicated phone lines while providing optional cellular communication. The panel offers two programmable Form-C relays and one fixed trouble relay, with USB and Ethernet connectivity for remote\/local programming via FS-Tools software.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSupports 50 Addressable Devices: Accepts any combination of detectors and modules on a single SLC loop.\u003c\/li\u003e\n\u003cli\u003eDual Communication Protocols: FlashScan and CLIP support for broad Notifier device compatibility.\u003c\/li\u003e\n\u003cli\u003ePre-Installed IPOTS-COM: Built-in dual communicator (IP + POTS) with optional cellular via CLSS Pathway.\u003c\/li\u003e\n\u003cli\u003eFlexible Power Input: Accepts 120\/240 VAC auto-sensing at 50\/60 Hz, 3.25 A max.\u003c\/li\u003e\n\u003cli\u003eTwo Class A\/B NAC Circuits: Each rated at 250 mA; total shared output 2.7 A for NACs and ANN-BUS.\u003c\/li\u003e\n\u003cli\u003eBattery Backup Support: Holds two 12 V, 18 AH batteries for 24 V backup (7–18 AH supported).\u003c\/li\u003e\n\u003cli\u003eProgramming and Diagnostics: USB and Ethernet access for full programming and system diagnostics via FS-Tools.\u003c\/li\u003e\n\u003cli\u003eIntegrated Relays: Two programmable Form-C relays for custom logic and one fixed trouble relay.\u003c\/li\u003e\n\u003cli\u003eEvent History Storage: USB port enables history export, status review, and walk-test data access.\u003c\/li\u003e\n\u003cli\u003eUL and NFPA Compliant: Listed for use in commercial fire detection applications across the U.S. and internationally.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe NFW-50X delivers enhanced control, programming flexibility, and modern connectivity in a compact, intelligent FACP designed for advanced fire system performance.\u003c\/p\u003e","brand":"Notifier","offers":[{"title":"Default Title","offer_id":49105357373696,"sku":"NFW-50X","price":2038.89,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0388\/5331\/2557\/files\/CC-TDOR11_7.png?v=1785545558","url":"https:\/\/alotechparts.com\/products\/nfw-50x-notifier-fire-alarm-control-panel","provider":"Alo Tech Solutions","version":"1.0","type":"link"}