{"product_id":"nfn-gw-pc-hnw-2-notifier-fire-alarm-gateway-for-onyxworks-nfn-networks","title":"NFN-GW-PC-HNW-2 | Notifier Fire Alarm Gateway for ONYXWorks NFN Networks","description":"\u003ch4\u003eDescription \u003c\/h4\u003e\n\u003cp data-start=\"144\" data-end=\"396\"\u003eThe Notifier NFN-GW-PC-HNW-2 is an intelligent gateway interface designed for ONYXWorks® fire monitoring workstations. It enables full monitoring and control of Notifier fire alarm control panels across standard or high-speed NOTI•FIRE•NET™ (NFN) networks. This gateway supports advanced network functions such as panel programming, diagnostics, and control operations to ensure seamless system management.\u003c\/p\u003e\n\u003cp data-start=\"284\" data-end=\"574\" class=\"\"\u003e \u003c\/p\u003e\n\u003cp data-start=\"284\" data-end=\"574\" class=\"\"\u003e \u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications \u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNew\/Never Used Surplus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNotifier\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFire Alarm Networking\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNFN-GW-PC-HNW-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSubcategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNetwork Gateways\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCompatibility\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eONYXWorks®, ONYX FirstVision®, ONYX Series, N16 INSPIRE™, BACnet Gateway, NCA-2, NCD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSupported NFN Versions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eVersion 5.0 and higher\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNetwork Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStandard or High-Speed NFN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnection Options\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWire, multimode fiber, singlemode fiber\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eControl Functions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAcknowledge, silence, reset, enable\/disable, activate\/deactivate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePanel Programming\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSupports upload\/download and modifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePC Version Requirements\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRequires ONYXWorks workstation (see DN-7048)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0°C to 49°C (32°F to 120°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEmbedded Version Input\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e19–29 VDC, 450 mA @ 24 VDC (NFPA Class A\/B operation)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting (Embedded)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCHS-4L chassis in CAB-4 Series cabinet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eListings \u0026amp; Approvals\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUL, ULC, FM, CSFM, FDNY Approved\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUnit of Measurement\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEach (EA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduction Status\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eActive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12.5 × 10 × 4 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2–4 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4\u003e\u003cbr\u003e\u003c\/h4\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eInformation About \u003cmeta charset=\"utf-8\"\u003e \u003cspan data-sheets-root=\"1\"\u003eNFN-GW-PC-HNW-2 \u003c\/span\u003e\n\u003c\/h4\u003e\n\u003cp\u003eThe NFN-GW-PC-HNW-2 is part of Notifier’s NOTI•FIRE•NET™ gateway series, built to integrate ONYXWorks® and ONYX FirstVision® systems with fire alarm control panels. The PC version of the gateway serves as the primary network interface for true peer-to-peer NFN networks, supporting both wire and fiber connections in standard or high-speed modes. It provides workstation-level monitoring, acknowledgments, resets, and enable\/disable functions, ensuring complete command capabilities. With support for redundancy and supervised IP connections, this gateway is designed for scalable, mission-critical fire safety networks.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eComplete Monitoring: Supports alarm, pre-alarm, trouble, and disable event tracking across NFN networks.\u003c\/li\u003e\n\u003cli\u003eControl Functions: Enables acknowledge, silence, reset, enable\/disable, and activate\/deactivate operations directly from ONYXWorks.\u003c\/li\u003e\n\u003cli\u003eProgramming Support: Facilitates panel programming uploads, downloads, and modifications.\u003c\/li\u003e\n\u003cli\u003eFlexible Network Options: Compatible with standard (wire\/multimode fiber) and high-speed (wire\/singlemode\/multimode fiber) NFN networks.\u003c\/li\u003e\n\u003cli\u003eGateway Redundancy: Provides network survivability through redundant gateway configurations.\u003c\/li\u003e\n\u003cli\u003eSupervised IP Connections: Ensures secure communication for remote workstations and gateways.\u003c\/li\u003e\n\u003cli\u003eMulti-Workstation Access: Allows simultaneous access from multiple ONYXWorks workstations.\u003c\/li\u003e\n\u003cli\u003eSystem Compatibility: Interfaces with ONYX® Series, N16 INSPIRE™, BACnet Gateway, NCA-2, and NCD devices (NFN v5.0+).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe NFN-GW-PC-HNW-2 delivers the reliability and precision required for secure fire alarm network communication and centralized control.\u003c\/p\u003e","brand":"Notifier","offers":[{"title":"Default Title","offer_id":49105159880960,"sku":"NFN-GW-PC-HNW-2","price":4402.65,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0388\/5331\/2557\/files\/NFN-GW-PC-HNW-2.jpg?v=1785541599","url":"https:\/\/alotechparts.com\/products\/nfn-gw-pc-hnw-2-notifier-fire-alarm-gateway-for-onyxworks-nfn-networks","provider":"Alo Tech Solutions","version":"1.0","type":"link"}