{"product_id":"ms-5024ud-fire-lite-replacement-board-for-5-zone-facp-with-dact","title":"MS-5024UD | Fire-Lite Replacement Board for 5-Zone FACP with DACT","description":"\u003ch4\u003eDescription \u003c\/h4\u003e\n\u003cp data-end=\"396\" data-start=\"144\"\u003eThe Fire-Lite MS-5024UD Old Style Replacement Board is designed for the 5-zone MS-5024UD fire alarm control panel with built-in digital communicator. It restores full functionality of conventional detection, zone supervision, and remote upload\/download capability.\u003c\/p\u003e\n\u003cp class=\"\" data-end=\"574\" data-start=\"284\"\u003e \u003c\/p\u003e\n\u003cp class=\"\" data-end=\"574\" data-start=\"284\"\u003e \u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications \u003c\/h4\u003e\n\u003ctable style=\"width: 100%; height: 293.907px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 22.7155%; height: 19.5938px;\"\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 76.9209%; height: 19.5938px;\"\u003eNew\/Never Used Surplus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 22.7155%; height: 19.5938px;\"\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 76.9209%; height: 19.5938px;\"\u003eFire-Lite\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 22.7155%; height: 19.5938px;\"\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 76.9209%; height: 19.5938px;\"\u003eFire Alarm Systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 22.7155%; height: 19.5938px;\"\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 76.9209%; height: 19.5938px;\"\u003eMS-5024UD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 22.7155%; height: 19.5938px;\"\u003e\u003cstrong\u003eSubcategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 76.9209%; height: 19.5938px;\"\u003eReplacement Board\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 22.7155%; height: 19.5938px;\"\u003e\u003cstrong\u003eCompatibility\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 76.9209%; height: 19.5938px;\"\u003eFire-Lite MS-5024UD (Old Style)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 22.7155%; height: 19.5938px;\"\u003e\u003cstrong\u003eZones Supported\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 76.9209%; height: 19.5938px;\"\u003e5 conventional Class B zones (convertible to Class A with CAC-5F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 22.7155%; height: 19.5938px;\"\u003e\u003cstrong\u003eCommunicator\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 76.9209%; height: 19.5938px;\"\u003eDigital communicator (no Contact ID support in Old Style)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 22.7155%; height: 19.5938px;\"\u003e\u003cstrong\u003eUpload\/Download\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 76.9209%; height: 19.5938px;\"\u003eRemote programming capability\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003ctd style=\"width: 22.7155%; height: 39.1875px;\"\u003e\u003cstrong\u003eOptional Modules\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 76.9209%; height: 39.1875px;\"\u003eADM-24 (Annunciator Driver), RM-5F (Five-zone Relay), CAC-5F (Class A Converter), PRT-24 (Printer Interface)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 22.7155%; height: 19.5938px;\"\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 76.9209%; height: 19.5938px;\"\u003eFire alarm panel repair and maintenance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 22.7155%; height: 19.5938px;\"\u003e\u003cstrong\u003eInstallation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 76.9209%; height: 19.5938px;\"\u003eDirect replacement into existing MS-5024UD panel enclosure\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 22.7155%; height: 19.5938px;\"\u003e\u003cstrong\u003eConstruction\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 76.9209%; height: 19.5938px;\"\u003eFactory-assembled PCB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 22.7155%; height: 19.5938px;\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 76.9209%; height: 19.5938px;\"\u003e2.00 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003e\u003cbr\u003e\u003c\/h4\u003e\n\u003ch4\u003eInformation About \u003cspan data-sheets-root=\"1\"\u003eMS-5024UD\u003c\/span\u003e\n\u003c\/h4\u003e\n\u003cp\u003eThe MS-5024UD Old Style Replacement Board is a factory-built replacement designed to restore Fire-Lite’s MS-5024UD five-zone conventional fire alarm control panel with digital communicator. This board supports five initiating device circuits, providing Class B detection capability with optional conversion to Class A using the CAC-5F module. It also maintains remote upload\/download programming and supports expansion modules including annunciators, relays, and printer interfaces. Unlike the New Style version, the Old Style board does not support Contact ID communication, making it essential for maintaining compatibility with older systems still in service.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eDirect Replacement: Designed specifically for the Fire-Lite MS-5024UD Old Style panel.\u003c\/li\u003e\n\u003cli\u003eFive-Zone Operation: Supports five Class B initiating device circuits with optional Class A conversion.\u003c\/li\u003e\n\u003cli\u003eBuilt-In Communicator: Includes a digital communicator for remote reporting (no Contact ID in Old Style).\u003c\/li\u003e\n\u003cli\u003eRemote Programming: Supports upload\/download of panel settings for service efficiency.\u003c\/li\u003e\n\u003cli\u003eExpansion Compatibility: Works with ADM-24, RM-5F, CAC-5F, and PRT-24 modules for system flexibility.\u003c\/li\u003e\n\u003cli\u003eSimple Installation: Direct-fit replacement for damaged or failed boards in existing panels.\u003c\/li\u003e\n\u003cli\u003eFactory-Built PCB: Ensures reliable performance consistent with Fire-Lite specifications.\u003c\/li\u003e\n\u003cli\u003eLegacy System Support: Maintains functionality in older fire alarm installations without requiring panel replacement.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe MS-5024UD delivers the reliability and precision required for restoring conventional zone fire alarm control with digital communication.\u003c\/p\u003e","brand":"Fire-Lite","offers":[{"title":"Default Title","offer_id":49105188454656,"sku":"MS-5024UD","price":1933.05,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0388\/5331\/2557\/files\/dscn1929_1_1.png?v=1785542190","url":"https:\/\/alotechparts.com\/products\/ms-5024ud-fire-lite-replacement-board-for-5-zone-facp-with-dact","provider":"Alo Tech Solutions","version":"1.0","type":"link"}