{"product_id":"mps-24af-notifier-main-power-supply","title":"MPS-24AF | Notifier Main Power Supply","description":"\u003ch4\u003eDescription \u003c\/h4\u003e\n\u003cp\u003eThe Fire-Lite MPS-24AF is a regulated power supply unit designed for fire alarm applications, supporting system modules, notification appliances, and four-wire detectors. It features an integrated battery charger and delivers consistent 24 VDC output for reliable system performance.\u003c\/p\u003e\n\u003cp data-start=\"284\" data-end=\"574\" class=\"\"\u003e \u003c\/p\u003e\n\u003cp data-start=\"284\" data-end=\"574\" class=\"\"\u003e \u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications \u003c\/h4\u003e\n\u003ctable width=\"100%\" style=\"height: 383.86px; width: 100%;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 33.4844px;\"\u003e\n\u003cth style=\"width: 33.2492%; text-align: left; height: 33.4844px;\" class=\"text-left text-body1 text-bold py-10 pr-10 desktop:pr-[10rem] desktop:text-nowrap\"\u003eCondition\u003c\/th\u003e\n\u003ctd style=\"width: 66.3872%; height: 33.4844px;\" class=\"text-left text-body1 py-10 desktop:w-[60%]\"\u003eNew\/Never Used Surplus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003cth style=\"width: 33.2492%; text-align: left; height: 19.5938px;\" class=\"text-left text-body1 text-bold py-10 pr-10 desktop:pr-[10rem] desktop:text-nowrap\"\u003eBrand\u003c\/th\u003e\n\u003ctd style=\"width: 66.3872%; height: 19.5938px;\" class=\"text-left text-body1 py-10 desktop:w-[60%]\"\u003e\u003cspan data-sheets-root=\"1\"\u003eNotifier\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 23.6875px;\"\u003e\n\u003cth style=\"width: 33.2492%; text-align: left; height: 23.6875px;\"\u003eCategory\u003c\/th\u003e\n\u003ctd style=\"width: 66.3872%; height: 23.6875px;\"\u003e\n\u003cdiv class=\"mt-1 md:mt-0 column-left basis-2\/4 divide-y divide-rad-gray-10 border-b-[0.0625rem] border-rad-gray-10 md:border-0\"\u003e\n\u003cdiv class=\"flex gap-[1.75rem] md:gap-x-0 xl:gap-x-[1.875rem]\"\u003e\n\u003cdiv class=\"text-body-4 w-full font-light py-5 pl-4 md:py-6 md:pl-6 text-rad-gray-70\"\u003e\n\u003cdiv class=\"max-w-[8rem] break-words\"\u003e\n\u003cspan\u003e\u003c\/span\u003eFire Protection\u003cbr\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003cth style=\"width: 33.2492%; text-align: left; height: 19.5938px;\"\u003ePart Number\u003c\/th\u003e\n\u003ctd style=\"width: 66.3872%; height: 19.5938px;\"\u003e\n\u003cdiv class=\"mt-1 md:mt-0 column-left basis-2\/4 divide-y divide-rad-gray-10 border-b-[0.0625rem] border-rad-gray-10 md:border-0\"\u003e\n\u003cdiv class=\"flex gap-[1.75rem] md:gap-x-0 xl:gap-x-[1.875rem]\"\u003e\n\u003cdiv class=\"text-body-4 w-full font-light py-5 pl-4 md:py-6 md:pl-6 text-rad-gray-70\"\u003e\n\u003cdiv class=\"max-w-[8rem] break-words\"\u003e\u003cspan\u003e\u003cspan data-sheets-root=\"1\"\u003eMPS-24AF\u003c\/span\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 35.625px;\"\u003e\n\u003cth style=\"width: 33.2492%; text-align: left; height: 35.625px;\"\u003e\u003cspan\u003eSubcategory\u003c\/span\u003e\u003c\/th\u003e\n\u003ctd style=\"width: 66.3872%; height: 35.625px;\"\u003e\u003cspan data-sheets-root=\"1\"\u003e\u003cspan\u003ePower Supply Modules\u003c\/span\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003cth style=\"width: 33.2492%; text-align: left; height: 19.5938px;\"\u003e\u003cspan\u003ePower Output (Regulated)\u003c\/span\u003e\u003c\/th\u003e\n\u003ctd style=\"width: 66.3872%; height: 19.5938px;\"\u003e\u003cspan data-sheets-root=\"1\"\u003e\u003cspan\u003e24 VDC at 3.0 A (continuous)\u003c\/span\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003cth style=\"width: 33.2492%; text-align: left; height: 39.1875px;\"\u003e\u003cspan\u003eMaximum Combined Output\u003c\/span\u003e\u003c\/th\u003e\n\u003ctd style=\"width: 66.3872%; height: 39.1875px;\"\u003e\u003cspan data-sheets-root=\"1\"\u003e\u003cspan\u003e6.0 A at 24 VDC\u003c\/span\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003cth style=\"width: 33.2492%; text-align: left; height: 39.1875px;\"\u003e\u003cspan\u003eResettable Output\u003c\/span\u003e\u003c\/th\u003e\n\u003ctd style=\"width: 66.3872%; height: 39.1875px;\"\u003e\u003cspan data-sheets-root=\"1\"\u003e\u003cspan\u003e1.0 A for four-wire smoke detectors\u003c\/span\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 27.875px;\"\u003e\n\u003cth style=\"width: 33.2492%; text-align: left; height: 27.875px;\"\u003eBattery Charger Range\u003c\/th\u003e\n\u003ctd style=\"width: 66.3872%; height: 27.875px;\"\u003e9.5 AH to 55 AH\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003cth style=\"width: 33.2492%; text-align: left; height: 19.5938px;\"\u003eApplication\u003c\/th\u003e\n\u003ctd style=\"width: 66.3872%; height: 19.5938px;\"\u003eFire alarm systems and control modules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 30.4688px;\"\u003e\n\u003cth style=\"width: 33.2492%; text-align: left; height: 30.4688px;\"\u003ePrimary Power Input\u003c\/th\u003e\n\u003ctd style=\"width: 66.3872%; height: 30.4688px;\"\u003eVia TB1 terminal block (ground, neutral, hot)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003cth style=\"width: 33.2492%; text-align: left; height: 19.5938px;\"\u003eChassis Grounding\u003c\/th\u003e\n\u003ctd style=\"width: 66.3872%; height: 19.5938px;\"\u003eTB1 Terminal 1, via 71073 cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 17.1875px;\"\u003e\n\u003cth style=\"width: 33.2492%; text-align: left; height: 17.1875px;\"\u003ePanel Compatibility\u003c\/th\u003e\n\u003ctd style=\"width: 66.3872%; height: 17.1875px;\"\u003eFull-size Sensiscan 2000 and related systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003cth style=\"width: 33.2492%; text-align: left; height: 19.5938px;\"\u003eDimensions (HxWxD)\u003c\/th\u003e\n\u003ctd style=\"width: 66.3872%; height: 19.5938px;\"\u003e14 × 12 × 3 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003cth style=\"width: 33.2492%; text-align: left; height: 19.5938px;\"\u003eWeight\u003c\/th\u003e\n\u003ctd style=\"width: 66.3872%; height: 19.5938px;\"\u003e\u003cspan\u003e3 lbs\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003cspan style=\"font-size: 0.875rem;\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eInformation About \u003cspan data-sheets-root=\"1\"\u003e\u003cspan\u003eMPS-24AF\u003c\/span\u003e\u003c\/span\u003e\n\u003c\/h4\u003e\n\u003cp\u003eThe MPS-24AF provides up to 3 amps of continuous, regulated power output at 24 VDC, making it ideal for powering full-sized Sensiscan 2000 systems or other control panels and modules in fire alarm installations. It supports both system operation and notification appliance power, with up to 1 amp of resettable output available for powering four-wire smoke detectors. The unit includes an integral battery charger capable of maintaining batteries ranging from 9.5 to 55 amp-hours, ensuring uninterrupted performance during extended standby and alarm periods.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e3.0 Amp Regulated Output: Provides steady 24 VDC power to fire alarm modules and notification appliances.\u003c\/li\u003e\n\u003cli\u003eIntegral Battery Charger: Supports 9.5 AH to 55 AH battery configurations for backup power.\u003c\/li\u003e\n\u003cli\u003eResettable Power Output: Offers up to 1 amp of resettable 24 VDC power for four-wire smoke detectors.\u003c\/li\u003e\n\u003cli\u003eUL-Listed Notification Support: Compatible with a wide range of UL-listed 24 VDC notification appliances.\u003c\/li\u003e\n\u003cli\u003eFull System Support: Capable of continuously powering full-size control panels like the Sensiscan 2000.\u003c\/li\u003e\n\u003cli\u003eScrew Terminal Connections: Clearly labeled TB1 terminal block allows straightforward AC power input wiring.\u003c\/li\u003e\n\u003cli\u003eChassis Grounding Provision: Includes grounding terminal and cable for safe cabinet mounting.\u003c\/li\u003e\n\u003cli\u003eCompact and Lightweight: Measures 14\" × 12\" × 3\" and weighs only 3 lbs for convenient integration.\u003c\/li\u003e\n\u003cli\u003eField Replaceable Components: Designed for easy service and maintenance access.\u003c\/li\u003e\n\u003cli\u003eDual Mode Operation: Maintains system power during both standby and alarm conditions.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe MPS-24AF ensures reliable, uninterrupted power distribution to fire safety systems while simplifying integration and maintenance.\u003c\/p\u003e","brand":"Notifier","offers":[{"title":"Default Title","offer_id":49105316020480,"sku":"MPS-24AF","price":1615.53,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0388\/5331\/2557\/files\/b13cc9ab5b5c4ff391981ae9e76a4a3a.jpg?v=1785544812","url":"https:\/\/alotechparts.com\/products\/mps-24af-notifier-main-power-supply","provider":"Alo Tech Solutions","version":"1.0","type":"link"}